Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

A machine-learning inverse model framework for rapid forecasting and history matching in unconventional reservoirs

Model-based optimization for real-time forecasting in unconventional reser-voirs requires novel methods and work?ows since the strategies and work?ows used in conventional reservoirs are either inapplicable, or prohibitively expen-sive and time-consuming. Insu?cient site data and computational expense of high-?delity simulations mean that work?ows with high-?delity simulations are not ideal for usage in comprehensive uncertainty quanti?cation stud-ies that require 1000s of forward model runs. We present an alternative, novel work?ow for unconventional reservoirs, based on the interplay between reduced-order models and machine-learning. Our physics-informed machine-learning (PIML) work?ow addresses the challenges to real-time reservoir management in uncoventionals, namely lack of data (the time-frame for which the wells have been producing), and computational expense of high-?delity modeling. We use the machine-learning paradigm of transfer-learning to bind together fast but less accurate reduced-order models with slow, but accurate high-?delity models and circumvent the di?culties inherent in the current state-of-the-art for unconventionals. Such a PIML work?ow, grounded in physics, is a viable candidate for real-time history matching and production forecasting in a fractured shale gas reservoir. The signi?cance of our approach is that while it is developed for a particu-lar well and site in the Marcelus Shale gas reservoir of the Appalachian basin (MSEEL), it is not wedded to it. We expect the same work?ow can be ap-plied to other shale formations (e.g., Woodford, Barnett, Utica, EagleFord) should site-data become available, using the same set of machine-learning techniques from transfer learning. Some ?ne-tuning (or minimal retraining of the neural networks) will be required to transfer knowledge across shale gas sites/formations but it is a clearly superior alternative to developing a new machine-learning model altogether when considering a di?erent site.

Srinivasan, Shriram↗

Twin-pulse seeding enables pump-probe capabilities in the EUV to soft X-ray spectrum at synchrotron light sources

Having previously reported that separating the two stages of echo-enabled harmonic generation (EEHG) with one or more bending magnet (BM) sections allows the BMs to serve as the desired source of momentum compaction, here we demonstrate that this arrangement can greatly reduce the total energy modulation required by any 4th generation synchrotron light source, leading to higher repetition rates as well as stronger coherent radiation output power, with significant benefits. Since the EEHG beamline performance is mainly determined by the momentum compaction, beam emittances and beta functions of a storage ring lattice, allowing for different separations between the two stages is a straightforward way to increase the momentum compaction of chicane 1. This also enables pump-probe capabilities in a novel context, where twin-pulse seeding on the same electron bunch would allow two distinct radiation pulses with an adjustable delay in the range of 0.1 to 10 ps. In the twin-pulse seeding scheme, the same electron bunch could undergo modulation from two distinct laser pulses. Later stages would produce independent harmonics in subsequent straight sections. There are two variations of this twin-pulse seeding scheme, supporting different scientific applications. With a common modulation in stage 1, the first option allows simultaneously two independent radiation sources, with a full coverage of the EUV (2.5 to 50 nm) to soft X-ray (1.25 to 2.5 nm) spectrum; for the second option, the same stage 2 undulator could generate two coherent pulses both fitting within the FEL bandwidth, or at distinct harmonics. We present particle tracking simulation studies based on the APS-U lattice, including quantum excitation and radiation damping. These simulations indicate that there is no degradation of the modulated longitudinal phase space even when the two stages are separated by as many as 10 BM sections.

36 MATERIALS SCIENCE↗

Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

Time-integrated radiography using MeV Bremsstrahlung X-ray sources is the norm for imaging during system-level testing of components and structures under dynamic condition. One source of error in the analysis of the time-integrated radiography data sets stems from motion blur which smears out sharp interfaces to a greater degree with longer exposure times, which become necessary to provide sufficient signal-to-noise with low X-ray penetration of objects of interest. To quantify motion blur, a 1D shock wave through PMMA was investigated experimentally at The Dynamic Compression Sector at The Advanced Photon Source (DCS@APS) with tapered broadband and 25.46 ± 1.06 keV narrowband X-rays. Four cameras with different exposure times were used for each experiment to compare the effect that exposure time has on motion blur. In addition, our methodology to accurately simulate motion blur in terms of transmission and shape is presented and compared to our experimental results and quantified. There is a high level of agreement between the experimental and simulation results across the range of data sets investigated in this study with a percent difference range of 0.29–1.31% for the four shots. The methodology of this work serves as a steppingstone towards a physically validated model that could be used in conjunction with experimental results to deconvolve physical parameters, densities, and interfaces of interest in a way that would not be possible with experimental results alone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spallation nucleosynthesis by accelerated charged-particles

Recent observations have suggested the presence of radioactive elements, such as Pm and 84{<=}Z{<=}99 elements) at the surface of the magnetic star HD101065, also known as Przybylski's star. This star is know to be a chemically peculiar star and its anomalous 38<Z{<=}92 abundance pattern has been so far explained by diffusion processes in the stellar envelope. However, such processes cannot be called for to explain the origin of short-lived radioelements. The large magnetic field observed in Ap stars could be at the origin of a significant acceleration of charged-particles, mainly protons and {alpha}-particles, that in turn can by interaction with the stellar material modify the surface content.The present contribution explores to what extent the spallation processes resulting from the interaction of the stellar material with stellar energetic particle can by themselves only explain the abundances determined by observation at the surface of HD101065. We show that specific parametric simulations can explain many different observational aspects, and in particular that a significant production of Z>30 heavy elements can be achieved. In this nucleosynthesis process, the secondary-neutron captures play a crucial role. The most attractive feature of the spallation process is the systematic production of Pm and Tc and the possible synthesis of actinides and sub-actinides.Based on such a parametric model, it is also shown that intense fluences of accelerated charged-particles interacting with surrounding material can efficiently produce elements heavier than iron. Different regimes are investigated and shown to be at the origin of p- and s-nuclei in the case of high-fluence low-flux events and r-nuclei for high-fluence high-flux irradiations. The possible existence of such irradiation events need to be confirmed by hydrodynamics simulations, but most of all by spectroscopic observations through the detection of short-lived radio-elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fluence-to-Absorbed Dose Conversion Coefficients for Use in Radiological Protection of Embryo and Foetus Against External Exposure to Muons from 20MeV to 50GeV

This study used the Monte-Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to external muon fields. Monoenergetic muons ranging from 20 MeV to 50 GeV were considered. The irradiation geometries include anteroposterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT), isotropic (ISO), and top-down (TOP). At each of these irradiation geometries, absorbed doses to the foetal body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months, respectively. Muon fluence-to-absorbed-dose conversion coefficients were derived for the four prenatal ages. Since such conversion coefficients are yet unknown, the results presented here fill a data gap.

54 ENVIRONMENTAL SCIENCES↗

On-site Real-Time Inspection System for Pump-impeller using X-band Linac X-ray Source

The methods of nondestructive testing (NDT) are generally ultrasonic, neutron, eddy-current and X-rays, NDT by using X-rays, in particular, is the most useful inspection technique having high resolution. We can especially evaluate corroded pipes of petrochemical complex, nuclear and thermal-power plants by the high energy X-ray NDT system. We develop a portable X-ray NDT system with X-band linac and magnetron. This system can generate a 950 keV electron beam. We are able to get X-ray images of samples with 1 mm spatial resolution. This system has application to real time impeller inspection because linac based X-ray sources are able to generate pulsed X-rays. So, we can inspect the rotating impeller if the X-ray pulse rate is synchronized with the impeller rotation rate. This system has application in condition based maintenance (CBM) of nuclear plants, for example. However, 950 keV X-ray source can only be used for thin tubes with 20 mm thickness. We have started design of a 3.95 MeV X-band linac for broader X-ray NDT application. We think that this X-ray NDT system will be useful for corrosion wastage and cracking in thicker tubes at nuclear plants and impeller of larger pumps. This system consists of X-band linac, thermionic cathode electron gun, magnetron and waveguide components. For achieving higher electric fields the 3.95 MeV X-band linac structure has the side-coupled acceleration structure. This structure has more efficient acceleration than the 950 keV linac with alternating periodic structure (APS). We adopt a 1.3 MW magnetron for the RF source. This accelerator system is about 30 cm long. The beam current is about 150 mA, and X-ray dose rate is 10 Gy at 1 m/500 pps. In this paper, the detail of the whole system concept and the electromagnetic field of designed linac structure will be reported.

43 PARTICLE ACCELERATORS↗

Thermal Fatigue Life of Glidcop Al-15 High-Heat-Load Components

Shanghai Synchrotron Radiation Facility (SSRF) is a third-generation of synchrotron radiation light source and is presently under construction as a large scale national scientific project in China. Depending on the outstanding thermal and mechanical performance, Glidcop Al-15, a dispersion strengthened copper alloy, is chosen to serve for the high-heat-load components at beam line front end in SSRF. Present study is to investigate the thermal fatigue lives of critical SSRF components. A nonlinear finite element method (FEM) is used to simulate the nonlinear three dimensional stress-strain fields of the critical component-Mask2 at SSRF beam line. The method consists of transient temperature analyses followed by elastic-plastic stress analyses. Then, a critical plane approach is used to predict the thermal fatigue life of mask2. The critical plane approach is appropriate for estimating service life of critical SSRF components since the results are in good consistent with the experimental ones taken at the Advanced Photon Source (APS).

36 MATERIALS SCIENCE↗

Study of precision weak-link stage systems with large travel range and sub-nanometer-scale resolution

To use x-ray optics with nanometer resolution limit, scanning x-ray nanoprobes with corresponding mechanical positioning capability need to be designed. In particular, positioning stages with both sub-nanometer resolution and a positioning/scanning range of several millimeters are required. Based on our design of precision weak-link stages with interferometric encoders for the Center for Nanoscale Materials (CNM) hard x-ray nanoprobe at the Advanced Photon Source (APS) Sector 26, we have developed a new two-dimensional (2-D) weak-link stage system for nanopositioning of a specimen holder. This system provides sub-nanometer resolution, coupled with sub-nanometer metrology at a travel range of several millimeters. The 2-D weak-link stage system is designed with high structure stiffness using laminar overconstrained weak-link mechanisms [4-6]. In this paper we present the study of a linear precision weak-link stage system with sub-centimeter travel range and sub-nanometer positioning resolution. Design of a rotary weak-link stage system with 10-nrad resolution and 10-degree-level travel range is also discussed in this paper.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Confocal Microscope Alignment of Nanocrystals for Coherent Diffraction Imaging

We have installed and tested an Olympus LEXT confocal microscope at the 34-ID-C beamline of the Advanced Photon Source (APS). The beamline is for Coherent X-ray Diffraction (CXD) experiments in which a nanometre-sized crystal is aligned inside a focussed X-ray beam. The microscope was required for three-dimensional (3D) sample alignment to get around sphere-of-confusion issues when locating Bragg peaks in reciprocal space. In this way, and by use of strategic sample preparations, we have succeeded in measuring six Bragg peaks from a single 200 nm gold crystal and obtained six projections of its internal displacement field. This enables the clear identification of stacking-fault bands within the crystal. The confocal alignment method will allow a full determination of the strain tensor provided three or more Bragg reflections from the same crystal are found.

43 PARTICLE ACCELERATORS↗

Study of the Thermal Behavior of Syndiotactic and Atactic Polystyrene By Raman Spectroscopy

The glass properties and semi crystalline properties of polymers are observable by X-ray diffraction. Some previous works 1, 2, 3 were about determination of degree of crystallinity of sPS by various technologies, like for example DSC, XRD and Raman spectroscopy. The purpose of this paper is to show importance of Raman spectroscopy as analytical tool for the study of amorphous and semi-crystalline phase. The polymers on which our research is achieved, is amorphous polystyrene, shortened aPS, and semi crystalline polystyrene, sPS.

36 MATERIALS SCIENCE↗

Development of grating-based x-ray Talbot interferometry at the advanced photon source

We report on the ongoing effort to develop hard x-ray Talbot interferometry at the Advanced Photon Source (APS), Argonne National Laboratory, USA. We describe the design of the interferometer and preliminary results obtained at 25 keV using a feather and a phantom sample lithographically fabricated of gold. We mention the future developmental goals and applications of this technique as a metrology tool for x-ray optics and beam wavefront characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric evaluation of PLATO and Oncentra treatment planning systems for High Dose Rate (HDR) brachytherapy gynecological treatments

This study compares the dosimetric differences in HDR brachytherapy treatment plans calculated with Nucletron's PLATO and Oncentra MasterPlan treatment planning systems (TPS). Ten patients (1 T1b, 1 T2a, 6 T2b, 2 T4) having cervical carcinoma, median age of 43.5 years (range, 34-79 years) treated with tandem and ring applicator in our institution were selected retrospectively for this study. For both Plato and Oncentra TPS, the same orthogonal films anterior-posterior (AP) and lateral were used to manually draw the prescription and anatomical points using definitions from the Manchester system and recommendations from the ICRU report 38. Data input for PLATO was done using a digitizer and Epson Expression 10000XL scanner was used for Oncentra where the points were selected on the images in the screen. The prescription doses for these patients were 30 Gy to points right A (RA) and left A (LA) delivered in 5 fractions with Ir-192 HDR source. Two arrangements: one dwell position and two dwell positions on the tandem were used for dose calculation. The doses to the patient points right B (RB) and left B (LB), and to the organs at risk (OAR), bladder and rectum for each patient were calculated. The mean dose and the mean percentage difference in dose calculated by the two treatment planning systems were compared. Paired t-tests were used for statistical analysis. No significant differences in mean RB, LB, bladder and rectum doses were found with p-values > 0.14. The mean percent difference of doses in RB, LB, bladder and rectum are found to be less than 2.2%, 1.8%, 1.3% and 2.2%, respectively. Dose calculations based on the two different treatment planning systems were found to be consistent and the treatment plans can be made with either system in our department without any concern.

61 RADIATION PROTECTION AND DOSIMETRY↗

Variable length adjacent partitioning for PTS based PAPR reduction of OFDM signal

Peak-to-Average power ratio (PAPR) is a major drawback in OFDM communication. It leads the power amplifier into nonlinear region operation resulting into loss of data integrity. As such, there is a strong motivation to find techniques to reduce PAPR. Partial Transmit Sequence (PTS) is an attractive scheme for this purpose. Judicious partitioning the OFDM data frame into disjoint subsets is a pivotal component of any PTS scheme. Out of the existing partitioning techniques, adjacent partitioning is characterized by an attractive trade-off between cost and performance. With an aim of determining effects of length variability of adjacent partitions, we performed an investigation into the performances of a variable length adjacent partitioning (VL-AP) and fixed length adjacent partitioning in comparison with other partitioning schemes such as pseudorandom partitioning. Simulation results with different modulation and partitioning scenarios showed that fixed length adjacent partition had better performance compared to variable length adjacent partitioning. As expected, simulation results showed a slightly better performance of pseudorandom partitioning technique compared to fixed and variable adjacent partitioning schemes. However, as the pseudorandom technique incurs high computational complexities, adjacent partitioning schemes were still seen as favorable candidates for PAPR reduction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density of hydrophobically confined deeply cooled water investigated by small angle X-ray scattering

Water’s behavior near hydrophobic surfaces has attracted great attention due to chemical and geological applications. Here, we report small angle X-ray scattering (SAXS) studies of water confined in the hydrophobic nanoporous carbon material, CMK-1-14, from ambient to deeply cooled temperatures. By monitoring the scattering intensity of the first Bragg peak, which is directly related to the scattering length density contrast between the carbon matrix and the confined water, the average density of the hydrophobically confined water was determined from 300 K to 150 K at ambient pressure. Furthermore, differential scanning calorimetry and X-ray diffraction measurements showed that the majority of such hydrophobically confined water did not crystallize in the investigated temperature range. By exploiting the fast speed of SAXS measurements and the continuous temperature ramping, the average density profile and the deduced thermal expansion coefficient (α{sub p}) were obtained. We found that the well-known density maximum of water at 277 K downshifted to 260 K, and the density minimum which has been observed in hydrophilic confinement disappeared. In addition, the previously measured large density decreasing of 18% at low temperature was recalibrated to a more reasonable 10% instead. Consequently, the recalculated α{sub p} peak was found to be quite similar to that of the water confined in hydrophilic MCM-41-S-15 suggesting an intrinsic property of water, which does not sensitively depend on the confinement surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tunability of multichannel optical filter based on magnetized one-dimensional plasma photonic crystal

A one dimensional plasma photonic crystal (1DPPC) structure was proposed to design a tunable compressing/broadening multi-channel optical filter with external controllability. The 1DPPC with arrangement of (AP){sup n}D(PA){sup n}, where A and D are the dielectric materials, P is a magnetized plasma layer and n is the number of the periodicity, was proposed. The well-known transfer matrix method was employed for analysis. In linear transmittance spectrum, n − 1 defect modes were appeared inside the photonic band gap. The results were shown that by increasing the applied magnetic field intensity and its direction, a red-shift and blue-shift were, respectively, observed in defect mode frequencies. On the other hand, the modes were compressed and broadened with increasing the intensity and the direction of the applied magnetic field, respectively. Externally controllable defect modes can be useful in designing a multichannel tunable optical filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗