Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANGLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Electronic angle focusing for neutron time-of-flight powder diffractometers

A neutron time-of-flight (TOF) powder diffractometer with a continuous wide-angle array of detectors can be electronically focused to make a single pseudo-constant wavelength diffraction pattern, thus facilitating angle-dependent intensity corrections. The resulting powder diffraction peak profiles are affected by the neutron source emission profile and resemble the function currently used for TOF diffraction.

electronic focusing↗

Correlation-aware binning for small-angle neutron scattering via Gaussian-process inference

Binning in small-angle neutron scattering (SANS) is typically performed empirically, with fixed parameters chosen for convenience rather than statistical optimality. Such practices often fail to balance statistical precision and spatial resolution, leading to inconsistencies across instruments and datasets. Here we establish a correlation-aware framework that determines the optimal bin width from first principles by extending the classical Freedman–Diaconis (FD) rule to account for inter-bin correlations with a Gaussian process. In this formulation, the scattering intensity is treated as a smooth stochastic field whose statistical coherence is described by a covariance matrix. Analytical expressions of errors derived from this model yield closed-form criteria that separate the total deviation into contributions from counting noise, aliasing distortion and curvature-dependent correlation effects. Expressed in reduced variables, the resulting dimensionless error surface reveals a continuous transition from the uncorrelated FD regime to the correlation-dominated limit, providing a unified description of noise suppression and resolution control. Because the formulation depends only on the profile characteristics of scattering intensity I(Q), specifically its average intensity and first- and second-order derivatives, it applies generally to any SANS measurement regardless of sample, instrument or geometry. Experimental validation using small- and ultra-small-angle neutron scattering data confirms the predicted scaling behavior, demonstrating that correlation-aware inference systematically reduces mean-squared error and enables information-efficient reproducible data reduction across materials and instruments.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Analytical desmearing of Bonse–Hart ultra-small-angle neutron scattering data via truncated Abel inversion

A non-iterative analytical framework based on the truncated Abel inversion is developed for desmearing Bonse–Hart ultra-small-angle neutron scattering (USANS) data. The method directly inverts the slit-averaged intensity without empirical extrapolation or iterative regularization, establishing a closed-form relationship between the measured and intrinsic scattering profiles. Numerical benchmarks on representative models, including a rigid-line form factor, a Lorentzian function and a fractal structural model, demonstrate quantitative recovery of the ground-truth intensity across the full Q range. Application to a deuterated polystyrene/poly(2-vinylpyridine) blend further confirms that the approach yields smooth continuous profiles consistent with companion small-angle neutron scattering data. The truncated Abel inversion thus provides a stable, model-independent and physically transparent route for accurate desmearing of Bonse–Hart USANS measurements.

Huang, Guan-Rong [National Tsing Hua University, T↗

Feasibility of Correlation-Aware Inference and Universal Precision Scaling in Bonse–Hart Ultra-Small-Angle Neutron Scattering

Bonse–Hart ultra-small-angle neutron scattering (USANS) provides access to micrometre-scale structure, but useful measurements often require long counting times. In this work, we test whether the expected smoothness of the scattering profile can be exploited to improve data quality at lower counting statistics. We apply a Gaussian-process-based method to Bonse–Hart USANS data and evaluate its performance on pseudo-measurements generated from high-statistics experiments under Poisson statistics. This provides a stringent test of how well the underlying I(Q) profile can be reconstructed when the available counts are substantially reduced. We further show that, in the counting-limited regime, the reconstruction error follows a universal scaling behaviour that differs from the usual independent-counting expectation. At higher counts, the improvement crosses over to a resolution-limited regime set by analyser-angle discretization and rocking-curve width. These results clarify when correlation-aware inference is useful in USANS and provide a practical basis for improving measurement efficiency and beam-time usage.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Angle Droop Design for Grid-Forming Inverters Considering Impacts of Virtual Impedance Control

Grid-forming inverters (GFMs) based on active power-frequency droop control and reactive power-voltage droop control have been developed in recent years, which can generate voltage and frequency references for islanded power systems or microgrids to improve system-wide synchronization and power-sharing capability. It is known that the control delays in GFMs may cause system harmonic instability. To eliminate this issue, virtual impedance techniques are normally adopted. This paper gives a comprehensive examination of the impacts of virtual impedance control block Z v in GFMs on system stability. It is revealed that although Z v is effective in eliminating system harmonic stability, it may ruin system synchronization stability as a side effect. To compensate for the negative impacts caused by Z v , an active power-angle control block is added into the conventional droop control. Design criteria are also proposed accordingly to ensure system stability over the entire frequency range. Simulations and experimental testing are conducted to validate the analysis and the proposed design guidelines. It can be concluded that the Z v control-caused grid-synchronization instability issues can be eliminated with an appropriate active power-angle droop design.

Kong, Le↗

Reducing Conservativeness of Polytopic Linear-Parameter-Varying Robust Vehicle Sideslip Angle Observer Through Minimum-Area Convex Quadrilateral Design

The polytopic linear-parameter-varying (LPV) method has become increasingly popular for designing intelligent control and estimation systems for ground vehicles, particularly for the vehicle sideslip angle observer. In vehicle lateral dynamics, the vehicle longitudinal velocity-induced nonlinearities are conventionally outer-approximated with polytopes such as rectangles or triangles to obtain a polytopic LPV system. Yet, such polytopic approximations tend to be conservative and may lead to inadequate observer performance. To address this issue, a minimum-area convex quadrilateral construction is proposed in this paper to reduce design conservatism. The suggested design is demonstrated through the synthesis of an LPV H ∞ robust vehicle sideslip angle observer. Furthermore, a dSPACE-ASM simulation study is conducted to demonstrate the effectiveness and the advantage of the proposed polytopic construction over a baseline approach.

Zhou, Xingyu↗

Irradiation Experiments on High Efficiency Nanowire Solar Cells Including Tilted Incidence Angle

Nanowire based solar cells have promising potential to become the next generation of space solar cells. In this study we corroborate their high radiation tolerance by irradiating high efficiency GaAs (efficiency > 15 %) nanowire solar cells with 1 MeV electrons at a fluence of 10 16 e - /cm 2 . Additionally, we theoretically show that the damage in nanowire solar cells is expected to be slightly dependent on the incidence angle and the geometry of the nanowire array. However, experimentally, two sets of GaAs nanowire solar cells have been irradiated with 1 MeV electrons at normal incidence and with a 25° tilted angle exhibiting a similar degradation.

high specific power↗

Controllability Study of Propagating Mode Content by an Angle-Adjustable Mirror of a Miter-Bend in EC H&CD Transmission Line

A miter-bend-type mode converter, which has an angle-adjustable mirror, is proposed to control the transmission mode content in the electron cyclotron heating and current drive transmission line. This component excites the higher order mode by injecting a tilted radio frequency beam into a waveguide using the angle-adjustable mirror. A mock-up model of the converter was developed to evaluate the principle of the mode conversion.The experimental result of the mock-up representing the ratio of LP 01 mode and LP 11 mode was successfully controlled by 10% as the theoretical prediction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature effect on the glancing angle deposition of Si sculptured thin films

Si sculptured thin films consisting of spiral-, screw-, and columnlike-shaped nanostructures were grown by ion beam-induced glancing angle deposition of Si on rotating bare Si[001] substrates at different substrate rotational speeds and substrate temperatures ranging from room temperature to (360{+-}10) deg. C. For rotational speeds leading to the growth of nanoscrews at room temperature, morphology changes are observed with increasing temperature, such as an increase of the critical height at which single spiral fibers start merging to screws, thus giving the possibility to grow separated nanospirals with diameters of about 30 nm over a large thickness range. A decrease of the overall film thickness, indicating a change in the film density, is also observed with increasing the substrate temperature. For deposition conditions leading to the growth of vertical columns at room temperature, the substrate temperature influences the total number of columns, the column diameter, and the total structure height. The temperature-related changes in structure morphology show that surface diffusion effects play an important role in the morphological evolution of sculptured thin films consisting of helicoidal and columnlike structures during their growth by glancing angle deposition.

36 MATERIALS SCIENCE↗

Metal oxide morphology in argon-assisted glancing angle deposition

Glancing angle deposition (GLAD) is a thin film deposition technique capable of fabricating columnar architectures such as posts, helices, and chevrons with control over nanoscale film features. Argon bombardment during deposition modifies the GLAD process, producing films with new morphologies which have shown promise for sensing and photonic devices. The authors report modification of column tilt angle, film density, and specific surface area for 12 different metal oxide and fluoride film materials deposited using Ar-assisted GLAD. For the vapor flux/ion beam geometry and materials studied here, with increasing argon flux, the column tilt increases, film density increases, and specific surface area decreases. With a better understanding of the nature of property modification and the mechanisms responsible, the Ar-assisted deposition process can be more effectively targeted towards specific applications, including birefringent thin films or photonic crystal square spirals.

36 MATERIALS SCIENCE↗

Fixed-Angle Reflectance from Uranium Compounds and U-Bearing Minerals: Experimental Challenges to Determine the Optical Constants n and k

Fixed-angle reflectance spectroscopy using a commercial Fourier transform infrared (FTIR) spectrometer was employed to derive the optical constants n and k of several uranium compounds. This technique relies upon measurement of the quantitative reflectance R(?) spectra from a polished surface across a broad spectral range (in this case, the mid- and far-IR covering ca. 7500 to 50 cm-1) followed by application of the Kramers-Kronig transformation (KKT). Near-normal fixed-angle measurements as used in this technique require continuous reflectance spectra to as low a wavenumber value as possible. Here, we discuss some of the many challenges in measuring the far-IR and very far-IR (terahertz) spectra using an interferometric instrument, particularly those stemming from small sample sizes, typically just millimeters on a face for crystalline samples, as well as limitations due to optical components and diffraction. We apply this method to single-crystal UO2 and its mineralogical form uraninite, as well as other U-bearing minerals such as autunite [Ca(UO2)2(PO4)2·8-12H2O] and the dehydrated form of autunite, meta-autunite. In addition to the specular reflectance spectra, x-ray diffractometry was used as a confirmatory technique to analyze the surface composition of the species. Deriving the infrared optical constants for such U-bearing species (as well as other solids) will enable nondestructive detection under a variety of environmental and compositional conditions.

Uranium Minerals, infrared spectroscopy, optical c↗

Performance of the first mechanically-coupled twisting heliostat: encircled energy vs angle of incidence, and closed loop tracking

The first automatic twisting heliostat, with 8 m2 reflector, was completed and tested on-sun in January 2024. It was set up on a target-oriented dual-axis mount, with the target-axis aimed at a target 113 m to the west. The shape-twisting is purely automatic, made by a mechanical cam coupling to the cross-axis, which turns as the angle of incidence of the sun’s rays on the reflector. Three unsaturated images taken at different times of day were recorded of the sun on the target, reflected at angles of incidence of 5°, 49° and 68°. The measured FWHM of three images is very similar, about 1.09 m or 9.5 mrad, only slightly larger than an ideal solar disc, indicating that the different twisted reflector shapes are close to the ideal biconics needed to image the sun. The encircled energy measured for all three images was similar, 87% within approximately 1.30 m diameter. We report here also on a novel, tracking camera that employs a semitransparent beamsplitter fixed perpendicular to the mirror surface and to the plane of incidence. Over 2.5 hours of measurement of closed loop tracking, errors were ≤ 0.36 mrad rms, in both tracking axes.

14 SOLAR ENERGY↗

Angle-resolved scattering spectroscopy of explosives using an external cavity quantum cascade laser

Investigation of angle-resolved scattering from solid explosives residues on a car door for non-contact sensing geometries. Illumination with a mid-infrared external cavity quantum cascade laser tuning between 7 and 8 microns was detected both with a sensitive single point detector and a hyperspectral imaging camera. Spectral scattering phenomena were discussed and possibilities for hyperspectral imaging at large scattering angles were outlined.

(110.4234) Multispectral and hyperspectral imaging↗

Maximum dose angle for oblique incidence on primary beam protective barriers in the design of medical radiation therapy facilities

Primary barrier determinations for the shielding of medical radiation therapy facilities are generally made assuming normal beam incidence on the barrier, since this is geometrically the most unfavorable condition for that shielding barrier whenever the occupation line is allowed to run along the barrier. However, when the occupation line (for example, the wall of an adjacent building) runs perpendicular to the barrier (especially roof barrier), then two opposing factors come in to play: increasing obliquity angle with respect to the barrier increases the attenuation, while the distance to the calculation point decreases, hence, increasing the dose. As a result, there exists an angle ({alpha}{sub max}) for which the equivalent dose results in a maximum, constituting the most unfavorable geometric condition for that shielding barrier. Based on the usual NCRP Report No. 151 model, this article presents a simple formula for obtaining {alpha}{sub max}, which is a function of the thickness of the barrier (t{sub E}) and the equilibrium tenth-value layer (TVL{sub e}) of the shielding material for the nominal energy of the beam. It can be seen that {alpha}{sub max} increases for increasing TVL{sub e} (hence, beam energy) and decreases for increasing t{sub E}, with a range of variation that goes from 13 to 40 deg for concrete barriers thicknesses in the range of 50-300 cm and most commercially available teletherapy machines. This parameter has not been calculated in the existing literature for radiotherapy facilities design and has practical applications, as in calculating the required unoccupied roof shielding for the protection of a nearby building located in the plane of the primary beam rotation.

61 RADIATION PROTECTION AND DOSIMETRY↗

A novel solid-angle tomosynthesis (SAT) scanning scheme

Purpose: Digital tomosynthesis (DTS) recently gained extensive research interests in both diagnostic and radiation therapy fields. Conventional DTS images are generated by scanning an x-ray source and flat-panel detector pair on opposite sides of an object, with the scanning trajectory on a one-dimensional curve. A novel tomosynthesis method named solid-angle tomosynthesis (SAT) is proposed, where the x-ray source scans on an arbitrary shaped two-dimensional surface. Methods: An iterative algorithm in the form of total variation regulated expectation maximization is developed for SAT image reconstruction. The feasibility and effectiveness of SAT is corroborated by computer simulation studies using three-dimensional (3D) numerical phantoms including a 3D Shepp-Logan phantom and a volumetric CT image set of a human breast. Results: SAT is able to cover more space in Fourier domain more uniformly than conventional DTS. Greater coverage and more isotropy in the frequency domain translate to fewer artifacts and more accurately restored features in the in-plane reconstruction. Conclusions: Comparing with conventional DTS, SAT allows cone-shaped x-ray beams to project from more solid angles, thus provides more coverage in the spatial-frequency domain, resulting in better quality of reconstructed image.

60 APPLIED LIFE SCIENCES↗

An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements

Purpose: Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors propose an angle-dependent estimation technique, where the incident spectra across a wide range of angular trajectories can be estimated accurately with only a single phantom and a single axial scan in the absence of the knowledge of the bowtie filter. Methods: The proposed technique uses a uniform cylindrical phantom, made of ultra-high-molecular-weight polyethylene and positioned in an off-centered geometry. The projection data acquired with an axial scan have a twofold purpose. First, they serve as a reflection of the transmission measurements across different angular trajectories. Second, they are used to reconstruct the cross sectional image of the phantom, which is then utilized to compute the intersection length of each transmission measurement. With each CT detector element recording a range of transmission measurements for a single angular trajectory, the spectrum is estimated for that trajectory. A data conditioning procedure is used to combine information from hundreds of collected transmission measurements to accelerate the estimation speed, to reduce noise, and to improve estimation stability. The proposed spectral estimation technique was validated experimentally using a clinical scanner (Somatom Definition Flash, Siemens Healthcare, Germany) with spectra provided by the manufacturer serving as the comparison standard. Results obtained with the proposed technique were compared against those obtained from a second conventional transmission measurement technique with two materials (i.e., Cu and Al). After validation, the proposed technique was applied to measure spectra from the clinical system across a range of angular trajectories [−15°, 15°] and spectrum settings (80, 100, 120, 140 kVp). Results: At 140 kVp, the proposed technique was comparable to the conventional technique in terms of the mean energy difference (MED, −0.29 keV) and the normalized root mean square difference (NRMSD, 0.84%) from the comparison standard compared to 0.64 keV and 1.56%, respectively, with the conventional technique. The average absolute MEDs and NRMSDs across kVp settings and angular trajectories were less than 0.61 keV and 3.41%, respectively, which indicates a high level of estimation accuracy and stability. Conclusions: An angle-dependent estimation technique of CT x-ray spectra from rotational transmission measurements was proposed. Compared with the conventional technique, the proposed method simplifies the measurement procedures and enables incident spectral estimation for a wide range of angular trajectories. The proposed technique is suitable for rigorous research objectives as well as routine clinical quality control procedures.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-49: Automatic Beam Angle Determination for Lung IMRT Planning Using a Beam Configuration Atlas

Purpose: To present a technique to automatically determine beam angle configurations for lung IMRT planning based on the patient-specific anatomy and tumor geometry. Methods: The relationship between individual patient anatomy and proper beam configurations was learned from high quality clinical plans in three steps. First, a beam configuration atlas was obtained by classifying 60 lung IMRT plans into 6 beam configuration clusters based on a dissimilarity measure defined between different beam configurations. A beam configuration template was extracted from each cluster to form an atlas. Second, a beam efficiency index map (EI map) was constructed to characterize the geometry of the tumor relative to the lungs, the body and other OARs along each candidate beam direction. Finally, the EI maps of the clinical cases and the cluster assignments of their beam configurations were paired to train a Bayesian classification model. This technique was validated by leave-one-out cross validation with 16 cases randomly selected from the original dataset. An IMRT plan (autobeam plan) for each test case was generated using the beam configuration template according to the cluster assignment given by the model and was compared with the corresponding clinical plan. Results: The dosimetric parameters (mean±S.D. in percentage of prescription dose) in the auto-beam plans and in the clinical plans, respectively, and the p-values by a paired ttest (in parenthesis) are: lung Dmean: 16.3±9.3, 18.6±7.4 (0.48), esophagus Dmean: 28.4±18, 30.7±19.3 (0.02), Heart Dmean: 21.5±17.5,21.1±17.2 (0.76), Spinal Cord D2%: 48±23, 51.2±21.8 (0.01), PTV dose homogeneity (D2%–D99%): 22±27.4, 20.4±12.8 (0.10).The dose reductions by the autobeam plans in esophagus Dmean and cord D02 are statistically significant but the differences (<4%) may not be clinically significant. The other dosimetric parameters are not statistically different. Conclusion: Plans generated by the automatic beam angle determination method can achieve dosimetric quality equivalent to that of clinical plans. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

60 APPLIED LIFE SCIENCES↗