Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases

ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism

There are many treatment options in high-flow priapism. Those mentioned most often are watchful waiting, Doppler-guided compression, endovascular highly selective embolization, and surgery. We present a case of high-flow priapism in a 57-year-old man treated by percutaneous direct puncture embolization of a post-traumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate. Erectile function was preserved during a 12-month follow-up. No patients with percutaneous direct puncture embolization for high-flow priapism have been reported previously. Percutaneous direct puncture embolization is a potentially useful and safe method for management of high-flow priapism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT Perfusion for Early Response Evaluation of Radiofrequency Ablation of Focal Liver Lesions: First Experience

PurposeTo investigate the value of perfusion CT (P-CT) for early assessment of treatment response in patients undergoing radiofrequency ablation (RFA) of focal liver lesions.Methods and Materials20 consecutive patients (14 men; mean age 64 ± 14) undergoing P-CT within 24 h after RFA of liver metastases (n = 10) or HCC (n = 10) were retrospectively included. Two readers determined arterial liver perfusion (ALP, mL/min/100 mL), portal liver perfusion (PLP, mL/min/100 mL), and hepatic perfusion index (HPI, %) in all post-RFA lesions by placing a volume of interest in the necrotic central (CZ), the transition (TZ), and the surrounding parenchymal (PZ) zone. Patients were classified into complete responders (no residual tumor) and incomplete responders (residual/progressive tumor) using imaging follow-up with contrast-enhanced CT or MRI after a mean of 57 ± 30 days. Prediction of treatment response was evaluated using the area under the curve (AUC) from receiver operating characteristic analysis.ResultsMean ALP/PLP/HPI of both readers were 4.8/15.4/61.2 for the CZ, 9.9/16.8/66.3 for the TZ and 20.7/29.0/61.8 for the PZ. Interreader agreement of HPI was fair for the CZ (intraclass coefficient 0.713), good for the TZ (0.813), and excellent for the PZ (0.920). For both readers, there were significant differences in HPI of the CZ and TZ between responders and nonresponders (both, P < 0.05). HPI of the TZ showed the highest AUC (0.911) for prediction of residual tumor, suggesting a cut-off value of 76 %.ConclusionIncreased HPI of the transition zone assessed with P-CT after RFA might serve as an early quantitative biomarker for residual tumor in patients with focal liver lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolotherapy for Neuroendocrine Tumor Liver Metastases: Prognostic Factors for Hepatic Progression-Free Survival and Overall Survival

PurposeThe purpose of the study was to evaluate prognostic factors for survival outcomes following embolotherapy for neuroendocrine tumor (NET) liver metastases.Materials and MethodsThis was a multicenter retrospective study of 155 patients (60 years mean age, 57 % male) with NET liver metastases from pancreas (n = 71), gut (n = 68), lung (n = 8), or other/unknown (n = 8) primary sites treated with conventional transarterial chemoembolization (TACE, n = 50), transarterial radioembolization (TARE, n = 64), or transarterial embolization (TAE, n = 41) between 2004 and 2015. Patient-, tumor-, and treatment-related factors were evaluated for prognostic effect on hepatic progression-free survival (HPFS) and overall survival (OS) using unadjusted and propensity score-weighted univariate and multivariate Cox proportional hazards models.ResultsMedian HPFS and OS were 18.5 and 125.1 months for G1 (n = 75), 12.2 and 33.9 months for G2 (n = 60), and 4.9 and 9.3 months for G3 tumors (n = 20), respectively (p < 0.05). Tumor burden >50 % hepatic volume demonstrated 5.5- and 26.8-month shorter median HPFS and OS, respectively, versus burden ≤50 % (p < 0.05). There were no significant differences in HPFS or OS between gut or pancreas primaries. In multivariate HPFS analysis, there were no significant differences among embolotherapy modalities. In multivariate OS analysis, TARE had a higher hazard ratio than TACE (unadjusted Cox model: HR 2.1, p = 0.02; propensity score adjusted model: HR 1.8, p = 0.11), while TAE did not differ significantly from TACE.ConclusionHigher tumor grade and tumor burden prognosticated shorter HPFS and OS. TARE had a higher hazard ratio for OS than TACE. There were no significant differences in HPFS among embolotherapy modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Revascularization of Hemodialysis Thrombosed Grafts with the Hydrodynamic Thrombectomy Catheter. Our 7-Year Experience

PurposeTo evaluate the efficacy and safety of the hydrodynamic thrombectomy catheter (AngioJet DVX) in the salvage of thrombosed hemodialysis vascular grafts.Materials and MethodsA retrospective study was designed, including all patients with occluded arteriovenous grafts treated with the AngioJet system between 2007 and 2014 in our institution. Outcomes included technical success, clinical success, complications, and primary and secondary patencies. Procedural success was defined as angiographic confirmation of flow restoration, the presence of a pulsatile thrill along the graft, and successful resumption of at least one hemodialysis session. Primary and secondary patencies after first AVG thrombectomy were calculated with Kaplan–Meier curves. Cox regression was used to determine prognostic factors of primary patency after every thrombectomy episode.ResultsA total of 149 thrombectomies were performed in 68 grafts. After thrombectomy, endovascular treatment of one or more stenosis was performed in all cases. Technical success was 93% and clinical success was 86%. Complications occurred in 7 thrombectomies, most of them were minor except for one anastomosis rupture requiring surgery. Primary and secondary patencies were 52, 41, and 23 and 76, 68, and 57% at 3, 6 and 12 months, respectively. Independent prognostic factors of poor patency after every thrombectomy episode were the presence of residual thrombus (OR 1.831, P = 0.008) and time from last thrombosis (less than 1 month; and OR 7.116, P < 0.001).ConclusionPercutaneous mechanical thrombectomy with AngioJet is a safe technique with a high-clinical success rate. The presence of residual thrombus after thrombectomy and early re-occlusions are related to poorer results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Primary Postpartum Hemorrhage: Predictive Factors of Need for Embolic Material Conversion of Gelatin Sponge Particles to N-Butyl Cyanoacrylate

PurposeTo identify predictive factors for embolic material conversion to N-butyl cyanoacrylate (NBCA) for the treatment of primary postpartum hemorrhage (PPH) after failed transcatheter arterial embolization (TAE) using gelatin sponge (GS).Materials and MethodsInstitutional review board approval was obtained. We retrospectively studied 62 consecutive women with primary PPH who underwent TAE between January 2006 and March 2015. Five of them were excluded for the following: cardiopulmonary arrest at arrival (n = 1), uterine inversion (n = 1), and hysterectomy after TAE (n = 3). Remaining 57 women (age range, 21–43 years; mean, 32.6 years) comprised study population. TAE was initially performed using GS in all cases and then converted to NBCA after two embolizations using GS with persistent hemodynamic instability or vaginal bleeding. The patients’ background, uterine height, vital signs, laboratory tests, disseminated intravascular coagulation score, and details of procedure were reviewed. Univariate and multivariate analyses were performed to determine factors related to embolic material conversion.ResultsTechnical success rate was 100%. Fourteen patients (25%) needed embolic material conversion to NBCA. Univariate analysis showed that uterine height, systolic blood pressure (sBP), and hemoglobin level were significantly related to embolic material conversion to NBCA (P = 0.029, 0.030, and 0.042). Logistic regression analysis showed that uterine height (odds ratio, 1.37; P = 0.025) and sBP (odds ratio, 0.96; P = 0.003) were associated with embolic material conversion to NBCA.ConclusionUterine height and sBP can be predictive factors for embolic material conversion to NBCA for the treatment of PPH.Level of EvidenceLevel 4, Case Control Study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring

PurposeRadiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions.Materials and MethodsMedical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1–5th months: Staff did not receive feedback (n = 701) and (2) 6–8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose.ResultsPersonalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04–0.50) µSv/Gy cm{sup 2} versus (phase 2) 0.08 (0.02–0.24) µSv/Gy cm{sup 2}, p = 0.002].ConclusionPersonalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Survival Analysis of Advanced HCC Treated with Radioembolization: Comparing Impact of Clinical Performance Status Versus Vascular Invasion/Metastases

PurposeIn this study, we aim to compare the effects of prognostic indicators on survival analysis for Barcelona Clinic Liver Cancer (BCLC) C patients undergoing yttrium-90 radioembolization (Y-90).MethodsA prospectively acquired database (2003–2017) for BCLC C hepatocellular carcinoma (HCC) patients that underwent radioembolization with Y-90 was searched. The criteria for BCLC C status (Eastern Cooperative Oncology Group (ECOG) performance status (PS) of 1 or 2, metastases, and/or portal vein thrombosis (PVT)) were recorded. Kaplan–Meier survival analyses were performed from the date of the first radioembolization with Y-90, censored to curative treatment, to determine median overall survival (OS). Cox regression hazards model was used for multivariate analyses. Significance was set at P < 0.05.Results547 BCLC C patients treated with radioembolization with Y-90 had a median OS of 10.7 months (range: 9.5–12.9). 43% (233 of 547) patients classified as BCLC C solely by their ECOG PS had a median OS of 19.4 months (14.7–23.7); 57% (314 of 547) patients with PVT/metastases had a median OS of 7.7 months (6.7–8.7). On multivariate analysis, ECOG PS was not found to be a statistically significant prognostic indicator of OS in BCLC C whereas metastases and PVT exhibited hazards ratios (95%CI) of 0.51 (0.38–0.69) and 0.49 (0.38–0.63), respectively (P < 0.0001).ConclusionPatients classified as BCLC C due to ECOG PS 1 demonstrated longer survival when compared to those presenting with PVT, metastases and/or ECOG PS 2. Hence, ECOG PS 1, as an isolated variable, may not be a true indicator of advanced disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multipath Curved Planar Reformations of Peripheral CT Angiography: Diagnostic Accuracy and Time Efficiency

ObjectivesTo compare diagnostic performance and time efficiency between 3D multipath curved planar reformations (mpCPRs) and axial images of CT angiography for the pre-interventional assessment of peripheral arterial disease (PAD), with digital subtraction angiography as the standard of reference.MethodsForty patients (10 females, mean age 72 years), referred to CTA prior to endovascular treatment of PAD, were prospectively included and underwent peripheral CT angiography. A semiautomated toolbox was used to render mpCPRs. Twenty-one arterial segments were defined in each leg; for each segment, the presence of stenosis > 70% was assessed on mpCPRs and axial images by two readers, independently, with digital subtraction angiography as gold standard.ResultsBoth readers reached lower sensitivity (Reader 1: 91 vs. 94%, p = 0.08; Reader 2: 89 vs. 93%, p = 0.03) but significantly higher specificity (Reader 1: 94 vs. 89%, p < 0.01; Reader 2: 96 vs. 95%, p = 0.01) with mpCPRs than with axial images. Reader 1 achieved significantly higher accuracy with mpCPRs (93 vs. 91%, p = 0.02), and Reader 2 had similar overall accuracy in both evaluations (94 vs. 94%, p = 0.96). Both readers read mpCPRs significantly faster than axial images (Reader 1: 5′45″ based on mpCPRs vs. 7′40″ based on axial images; Reader 2: 4′41″ based on mpCPRs vs. 6′57″ based on axial images; p < 0.01).ConclusionsmpCPRs are a promising 3D reformation technique that facilitates a fast assessment of PAD with high diagnostic accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transfemoral Venous Access Facilitates Upper Extremity Dialysis Interventions: Procedural Success and Clinical Outcomes

Purpose: To report technical success and clinical outcomes of transfemoral venous access for upper extremity dialysis interventions. Materials and Methods: A total of 15 patients underwent a transfemoral venous approach for fistulography (n = 4; 27%) or thrombectomy (n = 11; 73%) over a 14-month period. Access characteristics, sheath size, thrombectomy method, angioplasty site, fluoroscopy time, radiation dose, technical and clinical success, complications, and post-intervention primary and secondary patency rates were recorded. Results: Access type included arteriovenous fistulas (n = 10; 67%) and grafts (n = 5; 33%). The most common configuration was brachio-brachial (n = 6; 38%). Mean age of access was 37 months. Mean prior interventions were 4. Right CFV access was used in all patients using 6–8-French (most common: 7-French [n = 10; 67%]) sheaths. Most thrombectomies (n = 11; 73%) required both pharmacologic and mechanical maceration (n = 9; 82%). All accesses required angioplasty to treat underlying stenosis at the outflow vein (n = 12; 80%) or arteriovenous anastomosis (n = 9; 90%). Mean fluoroscopy time was 26.43 min. Air kerma and dose area product were 178.06 ± 225.77 mGy and 57,768.83 ± 87,553.29 μGym{sup 2}, respectively. Procedural and clinical success rates were 93% and 80%, respectively. Technical failure was due to persistent stenosis in one patient. Clinical failure was due to unsuccessful dialysis immediately following intervention in three patients. Mean post-intervention primary patency and secondary patency durations were 2.8 and 4.8 months, respectively. Primary patency rates at 1 and 3 months were 50% and 35%, respectively. Secondary patency rates at 1 and 3 months were 58% and 30%, respectively. Conclusion: A transfemoral venous approach for intervention of upper extremity dialysis accesses may be a valuable adjunct to traditional approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of Automated Supplying Artery Tracking Software Using Multidetector-Row Computed Tomography Images for Emergent Transcatheter Arterial Embolization

PurposeTo assess the reliability of a prototype automated supplying artery tracking software (ASATS) using multidetector-row CT (MDCT) images in emergent TAE.Materials and MethodsConsecutive 53 patients underwent 57 sessions of emergent TAE during 7 months. Twenty-one cases were excluded due to a lack of CT data (n = 12) or negative angiographic findings (n = 9). Remaining 34 sessions of TAE and MDCT images in 32 patients (mean age 62.9 years; age range 37–92 years) were enrolled. ASATS was retrospectively conducted for the identification of supplying arteries which were confirmed with angiography (automated method). Manual modification was added as needed (semi-automated method). Two observers independently reviewed the MDCT images to detect supplying arteries (manual method). Detectability of supplying artery and time to analysis were compared among the automated, semi-automated, and manual methods by both observers.ResultsA total of 64 bleeding sites were demonstrated on angiography. The detectability was 28 (43.8%) for automated method, 53 (82.8%) for semi-automated method, 55 (85.9%) for observer 1, and 58 (90.6%) for observer 2. Detectability of semi-automated method was significantly better than of automated method (P = 0.000) and comparable with manual method by both observers (P = 0.193 and 0.081). Average time to analysis was 185.4 s for automated method, 297.2 s for semi-automated method, 186.2 s for observer 1, and 243.7 s for observer 2.ConclusionASATS has a sufficient ability to identify supplying arteries of bleeding by adding manual modification as needed and can be used for emergent TAE. Level of Evidence: Level 4, Case Control Study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotically Assisted CBCT-Guided Needle Insertions: Preliminary Results in a Phantom Model

Aim: To compare robotic-assisted needle insertions performed under CBCT guidance to standard manual needle insertions. Materials and Methods: A homemade robotic prototype was used by two operators to perform robotic and manual needle insertions on a custom-made phantom. Both the operators had no experience with the prototype before starting the trial. The primary endpoint was accuracy (i.e., the minimal distance between the needle tip and the center of the target) between robotic and manual insertions. Secondary endpoints included total procedure time and operators’ radiation exposure. The Wilcoxon test was used. A p value less than 0.05 was considered statistically significant. Results: Thirty-three (17 manual, 16 robotic) needle insertions were performed. Mean accuracy for robotic insertion was 2.3 ± 0.9 mm (median 2.1; range 0.8–4.2) versus 2.3 ± 1 mm (median 2.1; range 0.7–4.4) for manual insertion (p = 0.84). Mean procedure time was 683 ± 57 s (median 670; range 611–849) for the robotic group versus 552 ± 40 s (median 548; range 486–621) for the manual group (p = 0.0002). Mean radiation exposure was 3.25 times less for the robotic insertion on comparison to manual insertion for the operator 1 (0.4 vs 1.3 µGy); and 4.15 times less for the operator 2 (1.9 vs 7.9 µGy). Conclusion: The tested robotic prototype showed accuracy comparable to that achieved with manual punctures coupled to a significant reduction of operators’ radiation exposure. Further, in vivo studies are necessary to confirm the efficiency of the system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjuvant Transjugular Variceal Occlusion at Creation of a Transjugular Intrahepatic Portosystemic Shunt (TIPS): Efficacy and Risks of Bucrylate Embolization

Adjuvant embolization of varices may reduce rebleeding in patients with a transjugular intrahepatic portosystemic shunt (TIPS). The aim of this study was to investigate the efficacy and the risks of adjuvant variceal embolization at TIPS implantation using bucrylate. Patients and Methods: The retrospective study evaluated 104 of 237 cirrhotic patients with TIPS for variceal bleeding who received adjuvant bucrylate embolization. For TIPS creation, bare stents were used in 35 patients (33.7%) and covered stents in 69 patients (66.3%) patients. Isolated gastric varices were seen in 10 patients (9.6%). Results: Six patients (5.8%) rebled during a median follow-up time of 26 months (1–57 months). Rebleeding occurred in 14% (5/35) of patients with a bare stent but only in 1.4% (1/69) of patients with a covered stent. The 1- and 2-year rebleeding rates of all patients were 0.9 and 2.9% and of patients receiving a bare stent were 2.9 and 8.6%, respectively. Bucrylate migration was seen in 13 patients (12.5%). In 9 of these patients (8.7%), asymptomatic lung embolization occurred. This was rare in patients with esophageal varices (3.1%) but frequent (60%) in patients with isolated gastric varices and a spontaneous splenorenal shunt. Conclusions: Our results suggest that adjuvant embolization using bucrylate is effective and delays variceal rebleeding. The general use of covered stents, however, alleviates the utility of adjuvant bucrylate embolization which may be restricted to patients with a high risk of rebleeding indicated by large varices, active, acute or recent variceal bleeding and advanced cirrhosis. Bucrylate should not be used in isolated gastric varices because it bears a high risk of migration into the lungs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion Guidance for In Situ Laser Fenestration of Aortic Stent graft for Endovascular Repair of Complex Aortic Aneurysm: Feasibility, Efficacy and Overall Functional Success

Objective: To evaluate feasibility, efficacy and overall functional success of image fusion guidance during laser-assisted in situ fenestration of aortic stent graft (LISFAS) for endovascular repair of complex aortic aneurysm (complex-EVAR) in a prospective study. Methods: Between September 2016 and July 2018, 20 patients were included and treated with LISFAS for complex-EVAR. Aortic aneurysms were either para-renal (n = 15) or thoraco-abdominal (n = 5) with 57 mm [first quartile: 54; third quartile: 68] median aneurysm diameter in 69 years [68;78] patients. All interventions were performed using the same angiographic system and 3D image fusion software for overlying pre-intervention CTA on per-intervention 2D fluoroscopy with cone-beam CT images to display target vessels ostia. Results: LISFAS for complex-EVAR with image fusion was performed in all patients, and no endovascular intervention required conversion to an open aortic repair. LISFAS of all target vessels was feasible in 18 patients (90%); 48 fenestrations out of 50 were performed successfully. Two fenestrations failed for renal arteries in two patients. Median ischemic times were as follows: 34 min [25;43] for superior mesenteric artery; 69 min [56;83] for left renal artery; 73 min [36;102] for right renal artery; and 93 min [89;96] for the celiac trunk. Median intervention and fluoroscopy times, iodinated contrast volume and X-ray exposure were 180 min [150;180], 74 min [64;87], 80 mL [59;113] and 338 Gy.cm{sup 2} [259;495], respectively. Efficacy was found in 17 patients (85%) on one-week follow-up CTA: Two patients had type 1 and 3 endoleaks, respectively, that were successfully embolized. Overall functional success was 90%. Median hospitalization stay was 9 days [8, 17]. The 30-day safety analysis was 90% (n = 2 deaths) owing to an undetermined cause and to bowel ischemia after low flow in intensive care unit. Conclusions: LISFAS using image fusion was feasible, efficient and overall functionally successful for complex-EVAR in this preliminary study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of the Vertebral Body Stenting System for the Restoration of Vertebral Height in Acute Traumatic Compression Fractures in a Non-osteoporotic Population

Introduction: To evaluate the effectiveness of percutaneous image-guided vertebral body stenting (VBS) at restoring vertebral height in acute, stable, traumatic thoracolumbar fractures in a young, non-osteoporotic population. Materials and Methods: A single-centre retrospective review of all traumatic non-osteoporotic fractures treated with VBS between 2010 and 2017 was performed. Inclusion criteria included patients with recent (< 10 days), symptomatic and stable thoracolumbar compression fractures. Patients with low-energy fractures, osteoporosis and age > 60/50 years (male/female) were excluded. Primary outcomes included: correction of vertebral height, correction of kyphosis angle and Beck Index on reconstructed pre- and post-procedural CBCT images. Secondary outcomes included intra-procedural stent recoil, complications, cement leakage and factors predicting height restoration. Results: Thirty-nine patients (26 men, 13 women; mean age 33.6 years, range 15–57 years) underwent VBS 5 days post-trauma on average (range 1–10), for stable compression fractures located between T5 and L5. Mean vertebral height gain, vertebral kyphosis angle correction and Beck index improvement were 3.8 mm (95% CI 3.36–4.50; P(> 3 mm) = 99.9%), 4.3° (95% CI 3.50–5.20; P(> 3°) = 99.9%) and 0.07 [95% CI 0.053–0.11], respectively (all statistically significant). Technical success was 92%, with 3 “major” stent recoils resulting in loss of vertebral height correction. No symptomatic complications were observed. No predictive factors for procedural success were identified. Conclusion: VBS can significantly restore vertebral height in young patients with traumatic vertebral compression fractures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Exposure During Transarterial Chemoembolization: Angio-CT Versus Cone-Beam CT

Introduction: Cone-beam computed tomography (CBCT) has been developed to improve reliability of many interventional radiology (IR) procedures performed with Angio system, such as transarterial chemoembolization (TACE). Angio-CT has emerged as a new imaging technology that combines a CT scanner with an Angio system in the same IR suite. The purpose of our study was to compare Angio system with CBCT capability and Angio-CT in terms of patient radiation exposure during TACE procedures. Materials and Methods: Consecutive TACE procedures performed between January 2016 and September 2017 with the two imaging modalities (Artis Zeego defining the CBCT group and Infinix-i 4D-CT defining the Angio-CT group) were reviewed. TACE and patient’s characteristics and patient radiation exposure parameters were collected. Dose-area products (DAP) and dose-length products (DLP) were converted into effective doses (ED) using conversion factors. Accuracy of tumor targeting and response was retrospectively assessed. Results: A total of 114 TACE procedures in 96 patients were included with 57 procedures in each group. The total ED in the Angio-CT group was 2.5 times lower than that in the CBCT group (median 15.4 vs. 39.2 mSv, p < 0.001). Both 2D ED and 3D ED were lower in the Angio-CT group than in the CBCT group (5.1 vs. 20 mSv, p < 0.001, and 7.4 vs. 17.9 mSv, p < 0.001, respectively). There was no significant difference neither in terms of classes of tumor targeting (p = 0.509) nor in terms of classes of tumor response (p = 0.070) between both groups. Conclusion: Angio-CT provides significant decrease in patient effective dose during TACE procedures compared to Angio system with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transjugular Liver Biopsy Following Left Lobe or Lateral Segment Transplantation in Pediatric Patients

Purpose: To evaluate the efficacy and safety of transjugular liver biopsy in pediatric patients with left lobe or lateral segment liver transplant. Materials and Methods: This was a retrospective study of data from 104 transjugular liver biopsies (57 children) using an 18- or 19-G biopsy needle. Transjugular liver biopsy was selected due to coagulopathy and/or ascites in 56 (54%) procedures. The median patient age, body weight, and interval from liver transplantation were 56 months, 16 kg, and 2 months, respectively. Technical success was defined as adequate liver specimens yield determined by the operator at the time of procedure. Complications, the longest length of obtained liver specimens according to needle type, and adequacy for histological diagnosis were analyzed. Result: Biopsy using a biopsy needle was successfully achieved in 103 procedures (99%). In one procedure, liver samples were obtained using biopsy forceps following unsuccessful attempts with a biopsy needle. Major complication occurred in one procedure following biopsies using both a biopsy needle and biopsy forceps. The patient received transfusion to manage decreased blood pressure and hemoglobin levels although post-biopsy venography did not show extravasation. The median longest length of liver specimens using 18-G (n = 63) and 19-G (n = 40) needles were 10 mm (range, 5–20) and 10 mm (range, 5–20), respectively (p = 0.704). Liver specimens were adequate for histological diagnosis in all procedures. Conclusion: Transjugular liver biopsy using a biopsy needle appears to be a safe and effective method to obtain liver specimens for histological diagnosis in pediatric patients with left lobe or lateral segment liver transplant. Level of Evidence: Level 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aerosols and their influence on radiation partitioning and savanna productivity in northern Australia

We investigated the effect of aerosols and clouds on the Net Ecosystem Productivity (NEP) of savannas in northern Australia using aerosol optical depth, clouds and radiation data from the Atmospheric Radiation Measurement (ARM) site in Darwin and carbon flux data measured from eddy covariance techniques from a site at Howard Springs, 35km southeast of Darwin. Generally we found that the concentration of aerosols in this region was relatively low than observed at other sites, therefore the proportion of diffuse radiation reaching the earths surface was only ~ 30%. As a result, we observed only a modest change in carbon uptake under aerosol laden skies and there was no significant difference for dry season Radiation Use Efficiency (RUE) between clear sky, aerosols or thin clouds. On the other hand thick clouds in the wet season produce much more diffuse radiation than aerosols or thin clouds and therefore the initial canopy quantum efficiency was seen to increase 45 and 2.5 times more than under thin clouds and aerosols respectively. The normalized carbon uptake under thick clouds is 57% and 50% higher than under aerosols and thin clouds respectively even though the total irradiance received under thick clouds was reduced 59% and 50% than under aerosols and thin clouds respectively. However, reduction in total irradiance decreases the mean absolute carbon uptake as much as 22% under heavy cloud cover compared to thin clouds or aerosols. Thus, any increase in aerosol concentration or cloud cover that can enhance the diffuse component may have large impacts on productivity in this region.

54 ENVIRONMENTAL SCIENCES↗