Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

High Performance Mars Liquid Cooling and Ventilation Garment Project

EVA space suit mobility in micro-gravity is enough of a challenge and in the gravity of Mars, improvements in mobility will enable the suited crew member to efficiently complete EVA objectives. The idea proposed is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area in order to free up the arms and legs by removing the liquid tubes currently used in the ISS EVA suit in the limbs. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased to provide the entire liquid cooling requirement and increase mobility by freeing up the arms and legs. Additional potential benefits of this approach include reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development.

Terrier, Douglas↗

Development of a Testbed for Pipeline Flushing - 20425

Pipelines which carry high-level waste within the DOE complex should be properly flushed in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water (flush volume) and flush velocity values used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to find optimal operating velocity modes/values in order to minimizing the flush volume and consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental test loop was recently developed for study of non-Newtonian slurry flushing at the Florida International University (FIU). This loop was designed to create sediment beds of various materials and bed heights and investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. A 165 ft experimental test loop made of 3-inch carbon steel pipes was constructed and used in initial testing campaigns. This pipe loop was equipped with real-time monitoring instruments to record variation of pressure, density, mass flow rate, and temperature during testing. Post-flush in-situ no-flow evaluations were performed using ultrasonic, endoscopy, and visual inspection. Additional post-flush evaluations were conducted using filtration and density monitoring of residuals within a designated circulations loop. These provisions enable comparison of pipeline cleanness before the start and after termination of flushing operations for efficiency evaluation. This paper presents efforts associated with flushing of kaolin-water mixtures at different concentrations and with various flush volume and flush velocity values/modes. In initial testing, efforts focused on creating repeatable sediment beds inside the pipeline in both fully-flooded (no pre-flush drainage) and gravity-drained (pre-flush drained) systems. Bed characterization (i.e., measurement of sediment height and solids concentration) was conducted to ensure about consistency of initial conditions between tests. Preliminary results for flushing study of 10% vol. kaolin-water mixtures starting from a fully-flooded initial condition showed that flushing with 1-line volume (65 gallons) could remove up to 72 percent of solids from the pipeline. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Active Reservoir Management Engineering and Evaluation Summary – Brine Extraction and Storage Test Phase II Final Report – Volumes 1-3

The Energy & Environmental Research Center (EERC) conducted a multiyear program over two phases to perform a field study of the potential efficacy of formation water extraction during carbon dioxide (CO 2 ) injection for CO 2 storage as a means of improving efficiency and/or effectiveness. Phase I was a 2-year study on potential methodologies for a field study of pressure management, culminating in site selection and experimental and site design. Phase II was a 7-year effort that involved constructing site facilities, conducting experiments, and evaluating collected field data. The experimental portion was split into two collaborative components, one for the active reservoir management (ARM) experiment and a second component to host and demonstrate potential water treatment technologies appropriate for high-saline brine at the project site. The results of the overall project are expected to benefit future saline storage projects through validation of techniques that may reduce stress on sealing formations, increase storage capacity, and reduce area of review. The following report focuses on the Phase II ARM experimental implementation and results. A second companion report summarizes the results of the high-saline brine demonstrations.

54 ENVIRONMENTAL SCIENCES↗

Fission Surface Power Technology Demonstration Unit Test Results

The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.

Facility Cooling System↗

Catalytic Interconversion of Ammonia and Dinitrogen at Base Metals

Best known as a fertilizer, ammonia is also a carbon-free fuel that produces only benign byproducts, nitrogen and water. Moreover, the synthesis of ammonia from water and nitrogen in the air can be used to store energy from renewable, yet intermittent power sources such as solar and wind. This work develops new molecular electrocatalysts to efficiently extract electrical energy from ammonia, a process which currently is underdeveloped. These studies inspire complementary electrochemical approaches for the synthesis of ammonia from nitrogen by coupling it with the protons ultimately to be derived from acidified water. Careful mechanistic studies that outline the molecular steps involved in these chemical transformations will inform the design of new classes efficient catalysts that interconvert ammonia and nitrogen. Importantly, this study targets molecular electrocatalysts with inexpensive, Earth abundant metals such as iron and copper, consistent with the sustainable use and synthesis of ammonia.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RAFT: Reconfigurable Array of High-Efficiency Ducted Turbines for Hydrokinetic Energy Harvesting

Diversifying the energy harvesting portfolio is crucial to achieving the ambitious goal of transitioning to clean energy by 2030. Marine hydrokinetic energy has garnered renewed interest due to its high harvesting potential in the U.S., and the resource's reliability and predictability—remaining relatively constant on a daily basis and available 24/7. However, there are currently few commercial devices capable of harnessing the energy from flowing water. This project aims to bridge that gap by designing and evaluating a novel hydrokinetic turbine concept that can efficiently harvest energy from both rivers and tidal streams. The RAFT (Reconfigurable Array of High-Efficiency Ducted Turbines) concept introduces a duct surrounding the turbine rotor and creates an array of small 5-kW units. The duct serves two primary purposes: (1) it enhances hydrodynamic efficiency by accelerating flow to the rotor, and (2) it functions as a structural component, facilitating the formation of modular arrays that lower costs. This project focuses on demonstrating this concept and validating these benefits through simulations and scaled prototype testing. The project team includes 8 faculty members and over 20 students from 3 universities, organized into three core areas: hydrodynamics, electrical systems, and structural analysis, with additional teams dedicated to system integration, environmental assessment and risk management, and tech-to-market strategy. The team successfully demonstrated the increased hydrodynamic efficiency of a ducted turbine compared to an unducted version using high-fidelity simulations and prototype tests. Moreover, design optimization efforts led to surpassing the SHARKS program's goal of 60% reduction of the levelized cost of energy with a significant margin.

13 HYDRO ENERGY↗

Studies of thermochemical water-splitting cycles

Higher temperatures and more isothermal heat profiles of solar heat sources are developed. The metal oxide metal sulfate class of cycles were suited for solar heat sources. Electrochemical oxidation of SO2 and thermochemical reactions are presented. Electrolytic oxidation of sulfur dioxide in dilute sulfuric acid solutions were appropriate for metal oxide metal sulfate cycles. The cell voltage at workable current densities required for the oxidation of SO2 was critical to the efficient operation of any metal oxide metal sulfate cycle. A sulfur dioxide depolarized electrolysis cell for the splitting of water via optimization of the anode reaction is discussed. Sulfuric acid concentrations of 30 to 35 weight percent are preferred. Platinized platinum or smooth platinum gave the best anode kinetics at a given potential of the five materials examined.

Remick, R. J.↗

Continuous electrocoagulation-membrane distillation unit for treating hydraulic fracturing produced water

Hydraulic fracturing oil and gas produced water is frequently highly impaired. While it is often deep well injected, there is great interest in treating this water for beneficial uses. Given the complexity of these produced waters, multiple unit operations are necessary. Electrocoagulation has been considered as a promising pretreatment technology. Here electrocoagulation is considered as a pretreatment prior to membrane distillation. The focus of this work is on understanding the electrocoagulation process in order to design an integrated unit operation. Electrocoagulation is used to remove organic compounds that will foul the membrane leading to membrane failure during membrane distillation. Using aluminum or iron electrodes, half-cell reactions in the electrocoagulation cell and electrode potentials have been calculated. Electrocoagulation was conducted using a continuous electrocoagulation reactor with actual produced water using aluminum, iron or mixed aluminum and iron electrodes. Here, the results obtained here indicate that electrocoagulation can obtain good removal efficiency of total organic carbon (TOC) by using different reaction conditions. Removal of organic compounds is essential to minimize fouling during membrane distillation. Further the performance of the electrocoagulation process depends strongly on the quality of the feed water. Insoluble species were more effectively coagulated than dissolved organic species. Continuous electrocoagulation shows great potential as a scalable unit operation for pretreating hydraulic fracturing produced water.

42 ENGINEERING↗

Sulfur Loading and Speciation Control the Hydrophobicity, Electron Transfer, Reactivity, and Selectivity of Sulfidized Nanoscale Zerovalent Iron

Sulfidized nanoscale zerovalent iron (SNZVI) is a promising material for groundwater remediation. However, the relationships between sulfur content and speciation and the properties of SNZVI materials are unknown, preventing rational design. Here, the effects of sulfur on the crystalline structure, hydrophobicity, sulfur speciation, corrosion potential, and electron transfer resistance are determined. Sulfur incorporation extended the nano-Fe 0 BCC lattice parameter, reduced the Fe local vacancies, and lowered the resistance to electron transfer. Impacts of the main sulfur species (FeS and FeS 2 ) on hydrophobicity (water contact angles) are consistent with density functional theory calculations for these FeS x phases. These properties well explain the reactivity and selectivity of SNZVI during the reductive dechlorination of trichloroethylene (TCE), a hydrophobic groundwater contaminant. Controlling the amount and speciation of sulfur in the SNZVI made it highly reactive (up to 0.41 L m -2 d -1 ) and selective for TCE degradation over water (up to 240 moles TCE per mole H 2 O), with an electron efficiency of up to 70%, and these values are 54-fold, 98-fold, and 160-fold higher than for NZVI, respectively. These findings can guide the rational design of robust SNZVI with properties tailored for specific application scenarios.

36 MATERIALS SCIENCE↗

Embolism resistance explains mortality and recovery of five subtropical evergreen broadleaf trees to persistent drought

Subtropical evergreen broadleaf forest (SEBF) is experiencing and expected to suffer more frequent and severe drought events. However, how the hydraulic traits directly link to the mortality and recovery of SEBF trees remains unclear. In this study, we conducted a drought-rewatering experiment on tree seedlings of five dominant species to investigate how the hydraulic traits were related to tree mortality and the resistance and recovery of photosynthesis (A) and transpiration (E) under different drought severities. Species with greater embolism resistance (P 50 ) survived longer than those with the weaker P 50 . However, there was no general hydraulic threshold associated with tree mortality, with the lethal hydraulic failure varying from 64% to 93% loss of conductance. Further, the photosynthesis and transpiration of tree species with greater P 50 were more resistant to and recovered faster from drought than those with lower P 50 . Other plant traits could not explain the interspecific variation in tree mortality and drought resistance and recovery. These results highlight the unique importance of embolism resistance in driving carbon and water process under persistent drought across different trees in SEBF. The absence of multiple efficient drought strategies in SEBF seedlings implies the difficulty of natural seedling regeneration under future droughts, which often occurs after destructive disturbances (e.g., extreme drought events and typhoon), suggesting that this biome may be highly vulnerable to co-occurring climate extremes.

54 ENVIRONMENTAL SCIENCES↗

Cu-Doped Iron Oxide for the Efficient Electrocatalytic Nitrate Reduction Reaction

The electrochemical nitrate reduction reaction (NO 3 RR) is a promising alternative synthetic route for sustainable ammonia (NH 3 ) production, because it not only eliminates nitrate (NO 3 – ) from water but also produces NH 3 under mild operating conditions. However, owing to the complicated eight-electron reaction and the competition from the hydrogen evolution reaction, developing catalysts with high activities and Faradaic efficiencies (FEs) is highly imperative to improve the reaction performance. In this study, Cu-doped Fe 3 O 4 flakes are fabricated and demonstrated to be excellent catalysts for electrochemical conversion of NO 3 – to NH 3 , with a maximum FE of ~100% and an NH 3 yield of 179.55 ± 16.37 mg h –1 mg cat –1 at –0.6 V vs RHE. Here, theoretical calculations reveal that doping the catalyst surface with Cu results in a more thermodynamically facile reaction. These results highlight the feasibility of promoting the NO 3 RR activity using heteroatom doping strategies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined Meteorological and Hydrologic Uncertainties Shape Projections of Future Soil Moisture in the Eastern United States

Physical hazards pose risks to many critical systems. Designing adaptive measures to mitigate these risks is challenging due to large uncertainties in modeling future hazards and the associated sectoral responses. Here, we help address this challenge in a hydrologic context by examining the combined role of meteorological forcing and hydrologic parameter uncertainties in shaping projections of future soil moisture. By encoding a simple conceptual water balance model in a differentiable programming framework, we facilitate fast runtimes and an efficient calibration, enabling an improved uncertainty analysis. We characterize uncertainty in model parameters by calibrating against different target data sets and by using several loss functions. We then convolve the resulting parameter ensemble with a set of Earth system model projections to produce a large ensemble (2,340 members) of daily soil moisture simulations. Focusing on the eastern United States, we find that most ensemble members project a drying of soils across the region, although some simulate wetter conditions throughout this century. Our ensemble shows an increase in the frequency and intensity of dry extremes while there is less agreement for wet extremes. We conduct sensitivity analyses on several soil moisture signatures to measure the relative influence of meteorological and hydrologic uncertainties across space and time. Both meteorological and hydrologic factors contribute consistently to uncertainty surrounding long-term trends, while changes to both wet and dry soil extremes are typically more sensitive to hydrologic parameter uncertainty. Our results underscore the need to account for varied sources of uncertainty when developing long-term hydrometeorological projections.

Lafferty, David C. [University of Illinois Urbana‐↗

Partially reduced Ru/RuO 2 composites as efficient and pH-universal electrocatalysts for hydrogen evolution

Efficient and long-term stable electrocatalysts for the hydrogen evolution reaction (HER) via water splitting are urgently desired to ease the energy crisis and develop the sustainability of human society. However, the HER performance of state-of-the-art Pt in non-acidic solutions is unsatisfactory due to the severely sluggish kinetics. In this work, DFT theoretical calculations reveal that the Ru/RuO 2 composites enable high HER activity to be pursued under non-acidic conditions because of the distinctive Ru and RuO 2 interface, which possess not only a strong capability to adsorb and dissociate water but also appropriate binding energies of H and OH. Therefore, we employ a simple strategy, including heating under an oxygen-poor environment and/or in situ electrochemical reduction, to partially reduce RuO 2 . The formed Ru/RuO 2 interfaces demonstrate superior HER activities (e.g. η 10 = 17 mV, 35 mV dec –1 in 1 M KOH) than Pt/C (e.g. η 10 = 27 mV, 58 mV dec –1 in 1 M KOH) at both small (10–100 mA cm –2 ) and large (1 A cm –2 ) current densities in alkaline solution and even real seawater. Comprehensive experiments were conducted to investigate the structure-HER performance relationships. Moreover, benefiting from the bifunctional character of RuO2, a two-electrode system based on Ru/RuO 2 composites and RuO 2 exhibits the lowest cell voltage for water splitting in both 1 M KOH and 0.5 M H 2 SO 4 , respectively. A 300 h-stability test at 10 mA cm –2 without an obvious decay demonstrates the industrial prospects of the Ru/RuO 2 composites to generate green energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D Printed Carbon Aerogels for Polymer-Electrolyte Fuel Cells

Carbon aerogels (CA) are known for ultra-low density, very high surface area, fine porous structure, and excellent electrical conductivity. Recent advances in high resolution 3D printing at LLNL enable the manufacturing of complex structured CA electrodes which have been demonstrated in electrolysis, flow battery, and supercapacitor applications. Polymer-electrolyte fuel cells (PEFC) may be an excellent candidate for these materials/methods as designers seek to optimize membrane-electrode assemblies to achieve higher efficiencies. A major challenge to PEFC design is two-phase flow due to water production which causes pore flooding and leads to cell instability and degradation. To mitigate these effects, groups have investigated the creation of liquid specific pathways in the porous layers to alleviate liquid buildup and enhance gas diffusion. While some progress has been made, traditionally manufactured GDLs, which consist of randomly distributed carbon fibers, are limiting. 3D printed CAs are a promising solution as complex macroporous electrode structures can be manufactured out of micro and nano porous filaments with a high level of control. Additionally, the process may allow for the consolidation of multiple layers (MPL, GDL, & flow channels) into a single printed architecture. In this work various CA lattice structures were printed using a direct ink write (DIW) method and liquid breakthrough pressures were measured to demonstrate the ability to tune the water pathways to achieve specific pressure thresholds. Furthermore, a discussion of the prospects for printed CA electrodes in PEFC will focus on material properties, synthesis techniques, and current challenges.

36 MATERIALS SCIENCE↗

Combined Thermal-Water Microgrid Model

SAND2022-3874 O The Combined Thermal-Water Microgrid Model is a set of three models combined with controls algorithms for a Water Thermal Storage (WTS), Ground Source Heat Pump (GSHP), and Thermal Bridge Loop (TBL) that serves a residential neighborhood. The model allows a parametric investigation of volume of water storage versus number of ground heat exchanger bore-holes versus seasonal energy efficiency measures. The code is being released as open source so that the entire study can be replicated per an open access journal publication. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Villa, Daniel↗

Alaska Liquid Natural Gas Pipeline Front-End Engineering & Design (Final Technical Report)

The Alaska Gasline Development Corporation (AGDC) is Alaska’s natural gas infrastructure development corporation established in 2013. AGDC’s mission is to maximize the benefit of Alaska’s vast North Slope natural gas resources for Alaskans through the development of infrastructure necessary to move the gas into local and international markets. AGDC was identified for a Congressionally Directed Spending (CDS) project for funding in the Energy and Water Development and Related Agencies Appropriations Act, 2023 under the heading: “Congressionally Directed Energy Efficiency and Renewable Energy Projects.” The CDS included $\$$4,000,000 of direct funding, with required match funds, to move the project forward. Alaska’s North Slope holds America’s largest proven and conventional natural gas supply. The integrated Alaska LNG Project will deliver 3.5 billion cubic feet of natural gas per day from Alaska’s North Slope gas fields to Alaskans as well as to a marine terminal located at tidewater in Cook Inlet. Alaska LNG is an integrated gas infrastructure project with three major components: a gas treatment plant (GTP) located at Prudhoe Bay, an 807-mile (1,287 km) gas pipeline (Mainline Pipeline) to Southcentral Alaska with interconnections for in-state gas use, and a natural gas liquefaction facility (LNG Facility) in Nikiski, Alaska. The integrated Alaska LNG Project has several strategic advantages including proven gas resources, existing upstream infrastructure, an advantageous arctic climate for LNG production, proximity to LNG markets, a track record of reliability from a state that first began exporting LNG to Japan in 1969, and broad support from Alaskans. North Slope natural gas is a conventional resource and can be produced with minimal drilling at a fraction of the carbon dioxide emissions of shale gas from the Lower 48 states. Through the development of the Alaska LNG Project, Alaska can provide energy security to Alaskans and a stable source of LNG to the Asia-Pacific region for generations. The Alaska LNG Project has been progressed through Pre-Front-End Engineering Design (Pre-FEED) and has obtained all major federal and State of Alaska permits and authorizations to construct the project, including the Federal Energy Regulatory Commission (FERC) Order Granting Authorization Under Section 3 of the Natural Gas Act. On September 5, 2024, the U.S. Department of Energy (DOE), National Energy Technology Laboratory (NETL) awarded Project No. DE-FE0032307 to AGDC with the objective to progress the project to Front-End Engineering Design (FEED) entry for the Alaska LNG Project Phase 1 Pipeline. The award Start Date was made effective July 1, 2023, with a Period of Performance through June 30, 2025. On March 27, 2025, AGDC announced the execution of definitive commercial agreements with Glenfarne Alaska LNG, LLC, an affiliate of Glenfarne Group, LLC, (together as “Glenfarne”), to lead the development of the Alaska LNG Project and enter FEED for the Phase 1 Pipeline. Project activities are now funded and directed by this private sector partner who holds a 75% interest in 8 Star Alaska, LLC (8 Star). 8 Star holds the assets of the Alaska LNG Project. As planned, AGDC continues to hold 25% minority interest in 8 Star and will play a governance role moving forward with Alaska LNG. This definitive commercial agreement milestone led to the successful completion of AGDC’s Statement of Project Objectives (SOPO) for FEED entry and led to the completion of DOE Project No. DE-FE0032307. At conclusion of the SOPO, AGDC also reached the award’s maximum federal cost share of $\$$4,000,000. AGDC is, therefore, providing Final Technical Report to close out DOE Project No. DE-FE0032307.

02 PETROLEUM↗

Advanced Data Management for the Wastewater Industry

This information sheet discusses the technology pillar Advanced Data Management as a pathway toward improving wastewater infrastructure sustainability and resiliency. To supplement existing literature on current technologies and policies for improving resiliency at wastewater treatment plants (WWTPs), this document aims to accomplish the following: • Summarize key technologies such as Supervisory Control and Data Acquisition (SCADA), digital twins, and smart sensors • Summarize relevant cybersecurity measures and data management tools available for WW utilities • Summarize advances in sensing and monitoring technologies • Serve as a comprehensive (though not exhaustive) repository for data management for wastewater utilities The Advanced Management Technical Information Sheet should be viewed as a general guide to established best practices for the water and wastewater sector when considering implementing energy capture and energy- or process-efficient technologies. Further details are presented in the SWIFt Technology Information Sheet Series for accompanying Technology Pillars.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗