Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Retrieval of Precipitation Profiles from Multiresolution, Multifrequency, Active and Passive Microwave Observations

In this study, a technique for estimating vertical profiles of precipitation from multifrequency, multiresolution active and passive microwave observations is investigated using both simulated and airborne data. The technique is applicable to the Tropical Rainfall Measuring Mission (TRMM) satellite multi-frequency active and passive observations. These observations are characterized by various spatial and sampling resolutions. This makes the retrieval problem mathematically more difficult and ill-determined because the quality of information decreases with decreasing resolution. A model that, given reflectivity profiles and a small set of parameters (including the cloud water content, the intercept drop size distribution, and a variable describing the frozen hydrometeor properties), simulates high-resolution brightness temperatures is used. The high-resolution simulated brightness temperatures are convolved at the real sensor resolution. An optimal estimation procedure is used to minimize the differences between simulated and observed brightness temperatures. The retrieval technique is investigated using cloud model synthetic and airborne data from the Fourth Convection And Moisture Experiment. Simulated high-resolution brightness temperatures and reflectivities and airborne observation strong are convolved at the resolution of the TRMM instruments and retrievals are performed and analyzed relative to the reference data used in observations synthesis. An illustration of the possible use of the technique in satellite rainfall estimation is presented through an application to TRMM data. The study suggests improvements in combined active and passive retrievals even when the instruments resolutions are significantly different. Future work needs to better quantify the retrievals performance, especially in connection with satellite applications, and the uncertainty of the models used in retrieval.

Grecu, Mircea↗

EGS Collab Experiment 2: Continuous Broadband Seismic Waveform Data

Two broadband seismometers were installed on the 4100 level and recorded for the duration of EGS Collab Experiment #2. Inspired by published data from similar instruments installed in the Aspo Hard Rock Lab, these long-period instruments aimed to measure the tilting of the drift in response to the injection of fluid into the testbed. One instrument was installed underneath the wellheads in Site A (aka the "battery" alcove) and the other was installed along the east wall of the drift, south of Site B. Due to the feet of gravel (ballast) laid along the floor of the drift, we were unable to anchor the sensors directly to the rock. As a result, the coupling of the sensors to the experiment rock volume is likely poor. In addition, there are a number of noise sources that complicate the interpretation of the data. For example, sensor BBB is installed adjacent (within 3 ft) to the rail line that runs towards the Ross shaft. Trains (motors) run along this line almost daily and produce a large signal in these data. Careful extraction of periods of interest, as well as filtering for specific signals, is necessary. The sensors are Nanometrics Trillium Compact Posthole seismometers, sensitive down to 120 seconds period. They were installed as close to the drift wall and as deep as we could manually excavate (only about 1 ft or so). The holes were leveled with sand and the sensors were placed on a paver before backfilling with sand. The hole was then covered by a bucket filled with insulation to improve the sensor's isolation from daily temperature variations, which are minor but present due to drift ventilation from the surface. Data were recorded on Nanometrics Centaur digitizers at 100 Hz. The full response information is available in the StationXML file provided here, or by querying the sensors through the IRIS DMC (see links below). These instruments were provided free of charge through the IRIS PASSCAL instrument center. The network code is XP and the station codes are BBA and BBB. The waveform data can be queried through the IRIS FDSN server using any method the user likes. One convenient option is to use the Obspy python package: https://docs.obspy.org/packages/obspy.clients.fdsn.html

15 GEOTHERMAL ENERGY↗

Thermocouples of tantalum and rhenium alloys for more stable vacuum-high temperature performance

Thermocouples of the present invention provide stability and performance reliability in systems involving high temperatures and vacuums by employing a bimetallic thermocouple sensor wherein each metal of the sensor is selected from a group of metals comprising tantalum and rhenium and alloys containing only those two metals. The tantalum, rhenium thermocouple sensor alloys provide bare metal thermocouple sensors having advantageous vapor pressure compatibilities and performance characteristics. The compatibility and physical characteristics of the thermocouple sensor alloys of the present invention result in improved emf, temperature properties and thermocouple hot junction performance. The thermocouples formed of the tantalum, rhenium alloys exhibit reliability and performance stability in systems involving high temperatures and vacuums and are adaptable to space propulsion and power systems and nuclear environments.

Morris, J. F.↗

Fiber Optic Sensors for Smart Materials and Structures

In this paper we describe recently developed fiber sensors which are capable of monitoring the health of smart-structures. The unobstrusive geometry of these sensors make them an excellent choice for embedding the sensor in composite materials to measure internal states of strain in structures and materials. Some of these sensors have gage lengths that can be tailored from tens of microns to many meters. We will describe various demodulation schemes (Pseudo-Heterodyne, Synthetic-Heterodyne, Homodyne, Differential-Cross Multiplier, and Single Channel Phase-Tracker) to obtain high bandwidth measurements, enabling measurement of static to high frequency impact generated strains with a dynamic response exceeding tens of thousands of microstrains. In addition, we will show that we can tailor the fiber sensor to either measure only strain and reject temperature response or measure only the temperature, or measure both temperature and strain simultaneously. We will also demonstrate the ability to measure multiple strain components inside a host simultaneously using a single fiber sensor embedded in the host using a certain sensor type and transverse strain immunity using another sensor type. Additionally we will show the ability to measure temperature up to 100 C using fiber optic sensors.

Singh, H.↗

Design for high-temperature /1800 deg F/ liquid metal pressure transducer

Thermionic diode sensor is used as a pressure transducer in advanced space power systems using liquid metals as working and heat transfer media at temperatures up to 1800 deg F. The sensor converts the motion of a pressure actuated refractory alloy capsule into a suitable electrical output.

Engdahl, R. E.↗

High Temperature Electronics for Venus Surface Applications: A Summary of Recent Technical Advances

This white paper has a technical focus meant to provide background to those unfamiliar with the challenges of high temperature electronics, and an understanding of why new surface mission concepts are now viable for Venus and other applications. It describes that, for the first time, high temperature electronics have been developed to enable a paradigm change in extended duration Venus surface exploration. This white paper concentrates on the advances made in Silicon Carbide (SiC) integrated circuit (IC) electronics that have matured to a state where a simple long-life scientific probe is feasible for Venus surface operations. These electronics have been demonstrated for more than a year at 500˚C, 60 days in high-fidelity simulated Venus surface conditions chamber, and have been integrated and demonstrated with prototype long-lived scientific observation sensor technology. Continued maturation of these needed high temperature electronics and sensors is ongoing in the Long-Lived In-Situ Solar System Explorer (LLISSE) project to provide an operational system including sensor control and operation, signal processing, power management, and communications in the early part of the 2020’s. A key focus of this work includes increasing the complexity and decreasing the power consumption of the ICs which will pave the way to enhanced capabilities, such as long-duration Venus seismic measurements. Other IC development efforts include high temperature memory, terrestrial based characterization of volcanic magma, and development of a simple microprocessor. This electronics has also shown to have exceptionally high radiation tolerance, and thus have relevance for a broad range of solar system exploration. Although presently at the level of complexity of 1970-1980 silicon-based electronics, such electronics can enable breakthroughs in Venus planetary exploration akin to 1970s-launched planetary exploration successes (such as Viking and Voyager).

High temperature Electronics↗

Overview of Quantum Sensing Materials and Techniques for Energy Sector Applications

The energy sector is dependent upon highly sensitive sensing devices for a wide range of applications. Variables such as temperature, pH, electromagnetic fields, and pressure must be measured with high precision, often in harsh conditions (e.g. high temperature, pressure and humidity). These sensors are deployed in infrastructure such as transformers, pipelines, mines, nuclear power plants, and other areas to ensure safe operating conditions and uninterrupted, optimized service. Moreover, new opportunities for sensors have emerged due to the expansion of smart grids/meters, driverless vehicles, and the discovery of new oil/gas deposits. The continued maturation of quantum sensors offers exciting opportunities for quantum-enhanced measurements to improve sensitivity beyond the classical limit. Here, an overview of established and emerging quantum materials and methods for sensing applications will be provided. Opportunities within the energy sector for quantum sensors will then be analyzed, including oil/gas discovery, greenhouse gas emission monitoring, pH and ion sensing, current measurements, and quantum-enhanced spectroscopy, along with barriers such as quantum sensor platform miniaturization and ruggedization. A specific project at the National Energy Technology Laboratory involving the functionalization of qubits using metal-organic frameworks for enhanced quantum sensing will then be highlighted. Here, nitrogen vacancy centers (NV) in nanodiamonds, a commercially available qubit with long coherence times and utilizable quantum properties at room temperature, are encapsulated using the metal-organic framework ZIF-8. Significantly, the ZIF-8 coating increases the longitudinal spin relaxation lifetime of the NV centers, an important parameter for spin relaxometry-based quantum sensing experiments. These results demonstrate the importance of qubit functionalization as a crucial step for rationally designing high performance quantum sensors.

Crawford, Scott↗

A Multilayered Thin Film Insulator for Harsh Environments

The status of work to develop a reliable high temperature dielectric thin film for use with thin film sensors is presented. The use of thin films to electrically insulate thin film sensors on engine components minimizes the intrusiveness of the sensor and allows a more accurate measurement of the environment. A variety of insulating films were investigated for preventing electrical shorting caused by insulator failure between the sensor and the component. By alternating layers of sputtered high temperature ceramics, a sequence of insulating layers was devised that prevents pinholes from forming completely through the insulator and maintains high electrical resistivity at high temperatures. The major technical challenge remaining is to optimize the fabrication of the insulator with respect to composition to achieve a reliable high temperature insulating film. Data from the testing of various potentially insulating thin film systems is presented and their application to thin film sensors is also discussed.

Wrbanek, John D.↗

Structural analysis of molten materials by a remote fiber optic Raman sensor

This study presents a novel in situ high-temperature fiber optic Raman probe that enables the study of the physical properties and structure of molten samples at temperatures up to 1400 °C. To demonstrate the functionality of the high-temperature fiber optic Raman probe, different composition mold fluxes were evaluated in this report. The Raman spectra at flux molten temperature were successfully collected and analyzed. A deconvolution algorithm was employed to identify peaks in the spectra associated with the molecular structure of the components in each sample. Here, the experimental results demonstrate that the composition-dependent Raman signal shift can be detected at high temperatures, indicating that molten materials analysis using a high-temperature Raman system shows significant promise. This flexible and reliable high-temperature Raman measurement method has great potential for various applications, such as materials development, composition and structure monitoring during high-temperature processing, chemical identification, and process monitoring in industrial production.

47 OTHER INSTRUMENTATION↗

Acoustic MEMS Sensor Array for Quench Detection of CICC Superconducting Cables

Here, a novel quench detection method using micro-electro-mechanical system (MEMS) sensor technology has been investigated in use for high temperature superconducting (HTS) conductors such REBCO tape cables. The sensor array along a superconducting cable, such as a cable-in-conduit-conductor (CICC), is installed in a cooling channel. It will allow sensitive and quick detection for a local quench of a superconducting cable. This work has confirmed that a quench of a single REBCO tape can be detected in liquid nitrogen by a MEMS piezoelectric microphone sensor. The quench detection design utilizing a MEMS sensor array method is discussed for the case of a toroidal field (TF) magnets of a fusion Tokamak device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Acoustic MEMS Sensor Array for Quench Detection of CICC Superconducting Cables

A novel quench detection method using microelectro- mechanical system (MEMS) sensor technology has been investigated in use for high temperature superconducting (HTS) conductors such REBCO tape cables. The sensor array along a superconducting cable, such as a cable-in-conduit-conductor (CICC), is installed in a cooling channel. It will allow sensitive and quick detection for a local quench of a superconducting cable. This work has confirmed that a quench of a single REBCO tape can be detected in liquid nitrogen by a MEMS piezoelectric microphone sensor. The quench detection design utilizing a MEMS sensor array method is discussed for the case of a toroidal field (TF) magnets of a fusion Tokamak device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Overview of High-Resolution, Non-Dispersive, Imaging Spectrometers for High-Energy Photons

High-resolution x-ray spectroscopy has become a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites initiated a new era in x-ray astronomy. Despite their successes, there is still need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band and for extended sources. What is needed is a non-dispersive imaging spectrometer - essentially a 14-bit x-ray color camera. And a requirement for a nondispersive spectrometer designed to provide eV-scale spectral resolution is a temperature below 0.1 K. The required spectral resolution and the constraints of thermodynamics and engineering dictate the temperature regime nearly independently of the details of the sensor or the read-out technology. Low-temperature spectrometers can be divided into two classes - - equilibrium and non-equilibrium. In the equilibrium devices, or calorimeters, the energy is deposited in an isolated thermal mass and the resulting increase in temperature is measured. In the non-equilibrium devices, the absorbed energy produces quantized excitations that are counted to determine the energy. The two approaches have different strong points, and within each class a variety of optimizations have been pursued. I will present the basic fundamentals of operation and the details of the most successful device designs to date. I will also discuss how the measurement priorities (resolution, energy band, count rate) influence the optimal choice of detector technology.

Kilbourne, Caroline↗

Geostationary Satellite Observations Over Global Environmental Monitoring Sites

Globally, there are now hundreds of ground-based environmental monitoring stations routinely collecting data on a variety of earth-atmosphere interactions. Such observations are also being augmented with data from orbiting satellites. With the beginning of the EOS-era, the MODIS subset around flux towers has been frequently used for validating ecosystem models developed at flux towers and upscaling the observed flux data to regional scales. However, MODIS on the polar-orbiting satellites can observe target regions only once a day, while the Fluxnet eddy- covariance data are compiled as sub-hourly. Therefore, summarizing the sub-hourly flux data into daily statistics is necessary for the comparison between MODIS and Flux data. The new generation geostationary satellite sensors (GOES-16/17 ABI and Himawari-8/9 AHI) have capabilities similar to MODIS but collect data at 5-15 minute intervals. These high-frequency observations allow us to understand and scale diurnal fluxes. Some studies have already shown the effective utilization of time series of geostationary satellite data for ecosystem modeling. We are producing NEX Level-1G products, which are gridded Top-of-Atmosphere reflectance and brightness temperature data from geostationary satellite sensors. We cut out the NEX Level-1G data using the same file format with the MODIS subset except for the projection. The other data products (e.g., surface reflectance, land surface temperature, vegetation indices, and climate data) will be added upon their availability. Currently included networks are Fluxnet, PhenoCam, and AERONET. The NEX subset data will be provided through NASA NEX data portal.

Geostationary Satellites↗

An initialization procedure for assimilating geostationary satellite data into numerical weather prediction models

An attempt was made to offset the limitations of GEO satellites for supplying timely initialization data for numerical weather prediction models (NWP). The NWP considered combined an isentropic representation of the free atmosphere with a sigma-coordinate model for the lower 200 mb. A flux form of the predictive equations described vertical transport interactions at the boundary of the two model domains, thereby accounting for the poor vertical temperature and wind field resolution of GEO satellite data. A variational analysis approach was employed to insert low resolution satellite-sensed temperature data at varying rates. The model vertical resolution was limited to that available from the satellite. Test simulations demonstrated that accuracy increases with the frequency of data updates, e.g., every 0.5-1 hr. The tests also showed that extensive cloud cover negates the capabilities of IR sensors and that microwave sensors will be needed for temperature estimations for 500-1000 mb levels.

Gal-Chen, T.↗

High temperature strain measurement with a resistance strain gage

A PdCr based electrical resistance strain gage was demonstrated in the laboratory to be a viable sensor candidate for static strain measurement at high temperatures. However, difficulties were encountered while transferring the sensor to field applications. This paper is therefore prepared for recognition and resolution of the problems likely to be encountered with PdCr strain gages in field applications. Errors caused by the measurement system, installation technique and lead wire attachment are discussed. The limitations and some considerations related to the temperature compensation technique used for this gage are also addressed.

Lei, Jih-Fen↗