Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Wavelength calibration of x-ray imaging crystal spectrometer on Joint Texas Experimental Tokamak

The wavelength calibration of x-ray imaging crystal spectrometer is a key issue for the measurements of plasma rotation. For the lack of available standard radiation source near 3.95 Å and there is no other diagnostics to measure the core rotation for inter-calibration, an indirect method by using tokamak plasma itself has been applied on joint Texas experimental tokamak. It is found that the core toroidal rotation velocity is not zero during locked mode phase. This is consistent with the observation of small oscillations on soft x-ray signals and electron cyclotron emission during locked-mode phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the radiation shielding for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak

A radiation shielding has been designed to reduce scattered neutrons and background gamma-rays for the new double-ring Time Of Flight Enhanced Diagnostics (TOFED). The shielding was designed based on simulation with the Monte Carlo code MCNP5. Dedicated model of the EAST tokamak has been developed together with the emission neutron source profile and spectrum; the latter were simulated with the Nubeam and GENESIS codes. Significant reduction of background radiation at the detector can be achieved and this satisfies the requirement of TOFED. The intensities of the scattered and direct neutrons in the line of sight of the TOFED neutron spectrometer at EAST are studied for future data interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of a Bonner sphere spectrometer for application to the determination of neutron field in the Experimental Advanced Superconducting Tokamak experimental hall

To assess the neutron energy spectra and the neutron dose for different positions around the Experimental Advanced Superconducting Tokamak (EAST) device, a Bonner Sphere Spectrometer (BSS) was developed at Peking University, with totally nine polyethylene spheres and a SP9 {sup 3}He counter. The response functions of the BSS were calculated by the Monte Carlo codes MCNP and GEANT4 with dedicated models, and good agreement was found between these two codes. A feasibility study was carried out with a simulated neutron energy spectrum around EAST, and the simulated “experimental” result of each sphere was obtained by calculating the response with MCNP, which used the simulated neutron energy spectrum as the input spectrum. With the deconvolution of the “experimental” measurement, the neutron energy spectrum was retrieved and compared with the preset one. Good consistence was found which offers confidence for the application of the BSS system for dose and spectrum measurements around a fusion device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in development of neutron energy spectrometer for deuterium plasma operation in KSTAR

Two types of DD neutron energy spectrometer (NES) are under development for deuterium plasma operation in KSTAR to understand behavior of beam ions in the plasma. One is based on the state-of-the-art nuclear emulsion technique. The other is based on a coincidence detection of a recoiled proton and a scattered neutron caused by an elastic scattering of an incident DD neutron, which is called an associated particle coincidence counting-NES. The prototype NES systems were installed at J-port in KSTAR in 2012. During the 2012 and 2013 experimental campaigns, multiple shots-integrated neutron spectra were preliminarily obtained by the nuclear emulsion-based NES system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combination of grazing incidence x-ray fluorescence with x-ray reflectivity in one table-top spectrometer for improved characterization of thin layer and implants on/in silicon wafers

As Grazing Incidence X-ray Fluorescence (GIXRF) analysis does not provide unambiguous results for the characterization of nanometre layers as well as nanometre depth profiles of implants in silicon wafers by its own, the approach of providing additional information using the signal from X-ray Reflectivity (XRR) was tested. As GIXRF already uses an X-ray beam impinging under grazing incidence and the variation of the angle of incidence, a GIXRF spectrometer was adapted with an XRR unit to obtain data from the angle dependent fluorescence radiation as well as data from the reflected beam. A θ-2θ goniometer was simulated by combining a translation and tilt movement of a Silicon Drift detector, which allows detecting the reflected beam over 5 orders of magnitude. HfO{sub 2} layers as well as As implants in Silicon wafers in the nanometre range were characterized using this new setup. A just recently published combined evaluation approach was used for data evaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a backscatter 14-MeV neutron time-of-flight spectrometer for experiments at ITER

Neutron energy spectrometry diagnostics play an important role in present-day experiments related to fusion energy research. Measurements and thorough analysis of the neutron emission from the fusion plasma give information on a number of basic fusion performance quantities, on the condition of the neutron source and plasma behavior. Here we discuss the backscatter Time-of-Flight (bTOF) spectrometer concept as a possible instrument for performing high resolution measurements of 14 MeV neutrons. The instrument is based on two sets of scintillators, a first scatterer exposed to a collimated neutron beam and a second detector set placed in the backward direction. The scintillators of the first set are enriched in deuterium to achieve neutron backscattering. The energy resolution and efficiency of a bTOF instrument have been determined for various geometrical configurations. A preliminary design of optimal geometry for the two scintillator sets has been obtained by Monte Carlo simulations based on the MCNPX code.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5 m × 2.5 m × 3 m, disturbances of the magnetic field are attenuated by factors of 5–50 at a bandwidth from 10{sup −3} Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the neutron electric dipole moment measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Invited Article: Characterization of background sources in space-based time-of-flight mass spectrometers

For instruments that use time-of-flight techniques to measure space plasma, there are common sources of background signals that evidence themselves in the data. The background from these sources may increase the complexity of data analysis and reduce the signal-to-noise response of the instrument, thereby diminishing the science value or usefulness of the data. This paper reviews several sources of background commonly found in time-of-flight mass spectrometers and illustrates their effect in actual data using examples from ACE-SWICS and MESSENGER-FIPS. Sources include penetrating particles and radiation, UV photons, energy straggling and angular scattering, electron stimulated desorption of ions, ion-induced electron emission, accidental coincidence events, and noise signatures from instrument electronics. Data signatures of these sources are shown, as well as mitigation strategies and design considerations for future instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared absorption of gaseous CH{sub 2}BrOO detected with a step-scan Fourier-transform absorption spectrometer

CH{sub 2}BrOO radicals were produced upon irradiation, with an excimer laser at 248 nm, of a flowing mixture of CH{sub 2}Br{sub 2} and O{sub 2}. A step-scan Fourier-transform spectrometer coupled with a multipass absorption cell was employed to record temporally resolved infrared (IR) absorption spectra of reaction intermediates. Transient absorption with origins at 1276.1, 1088.3, 961.0, and 884.9 cm{sup −1} are assigned to ν{sub 4} (CH{sub 2}-wagging), ν{sub 6} (O–O stretching), ν{sub 7} (CH{sub 2}-rocking mixed with C–O stretching), and ν{sub 8} (C–O stretching mixed with CH{sub 2}-rocking) modes of syn-CH{sub 2}BrOO, respectively. The assignments were made according to the expected photochemistry and a comparison of observed vibrational wavenumbers, relative IR intensities, and rotational contours with those predicted with the B3LYP/aug-cc-pVTZ method. The rotational contours of ν{sub 7} and ν{sub 8} indicate that hot bands involving the torsional (ν{sub 12}) mode are also present, with transitions 7{sub 0}{sup 1}12{sub v}{sup v} and 8{sub 0}{sup 1}12{sub v}{sup v}, v = 1–10. The most intense band (ν{sub 4}) of anti-CH{sub 2}BrOO near 1277 cm{sup −1} might have a small contribution to the observed spectra. Our work provides information for directly probing gaseous CH{sub 2}BrOO with IR spectroscopy, in either the atmosphere or laboratory experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A conceptual design of an electron spectrometer for ELI-NP

We present the geometry and field parameters of an Electron Spectrometer (ES) with two dipole magnets, considered for electron energy measurements at the High Fields QED experimental area at ELI-NP. The first magnet is a 2 meter long permanent magnet, placed inside the Interaction Chamber (IC). The second magnet is a 1.5 meters long electromagnet, placed outside IC. The pulsed electron beam will be produced by the 10 PW pulsed Laser, ‘pump-beam’, focused into one meter long capillary low density plasma cell. A second 10 PW pulsed Laser, ‘probe-beam’, will interact with the relativistic electron bunch providing the strong electromagnetic field. The ES will measure the subtle changes in the electron energy spectrum as a result of the electron beam interaction with the probe-beam field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the analysis of inhomogeneous magnetic field spectrometer for laser-driven ion acceleration

We present a detailed study of the use of a non-parallel, inhomogeneous magnetic field spectrometer for the investigation of laser-accelerated ion beams. Employing a wedged yoke design, we demonstrate the feasibility of an in-situ self-calibration technique of the non-uniform magnetic field and show that high-precision measurements of ion energies are possible in a wide-angle configuration. We also discuss the implications of a stacked detector system for unambiguous identification of different ion species present in the ion beam and explore the feasibility of detection of high energy particles beyond 100 MeV/amu in radiation harsh environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a tunable Fabry-Perot etalon-based near-infrared interference spectrometer for measurement of the HeI 2{sup 3}S-2{sup 3}P spectral line shape in magnetically confined torus plasmas

In magnetically confined torus plasmas, the local emission intensity, temperature, and flow velocity of atoms in the inboard and outboard scrape-off layers can be separately measured by a passive emission spectroscopy assisted by observation of the Zeeman splitting in their spectral line shape. To utilize this technique, a near-infrared interference spectrometer optimized for the observation of the helium 2{sup 3}S–2{sup 3}P transition spectral line (wavelength 1083 nm) has been developed. The applicability of the technique to actual torus devices is elucidated by calculating the spectral line shapes expected to be observed in LHD and QUEST (Q-shu University Experiment with Steady State Spherical Tokamak). In addition, the Zeeman effect on the spectral line shape is measured using a glow-discharge tube installed in a superconducting magnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of phonon backscattering due to confinement of ballistic phonon pathways in silicon as studied with a microfabricated phonon spectrometer

In this work, the mechanism for enhanced phonon backscattering in silicon is investigated. An understanding of phonon propagation through substrates has implications for engineering heat flow at the nanoscale, for understanding sources of decoherence in quantum systems, and for realizing efficient phonon-mediated particle detectors. In these systems, phonons that backscatter from the bottom of substrates, within the crystal or from interfaces, often contribute to the overall detector signal. We utilize a microscale phonon spectrometer, comprising superconducting tunnel junction emitters and detectors, to specifically probe phonon backscattering in silicon substrates (∼500 μm thick). By etching phonon “enhancers” or deep trenches (∼90 μm) around the detectors, we show that the backscattered signal level increases by a factor of ∼2 for two enhancers versus one enhancer. Using a geometric analysis of the phonon pathways, we show that the mechanism of the backscattered phonon enhancement is due to confinement of the ballistic phonon pathways and increased scattering off the enhancer walls. Our result is applicable to the geometric design and patterning of substrates that are employed in phonon-mediated detection devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Spectrometer with multichannel photon-counting detector for beam emission spectroscopy in magnetic fusion devices

A spectrometer based on a linear array photomultiplier tube (PMT) has been developed and calibrated. A 0.635 m focal length Czerny-Turner monochromator combined with a coupling optics provides an image of a narrow 0.5 nm spectral range with a resolution of 0.015 nm/channel on a 32-anode PMT. The system aims at spectroscopy of D{sub α} or H{sub α} lines emitted by a diagnostic atomic beam in a plasma (primarily a motional Stark effect diagnostics). To record a low photon flux of ∼10{sup 6} s{sup −1} per channel with the time resolution of 100 μs, a pulse counting approach has been used. Wideband amplifiers scale single-electron pulses and transmit them to a digital data processing core hardwired in a programmable logic matrix. Calibrations have shown that the aberration-limited instrument function fits to a single detector channel of 1 mm width. Pilot results of passive measurements of D{sub α} light emission from the plasma confined in a magnetic trap are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heating system of pellet samples integrated with terahertz spectrometer

This article describes automation of temperature-dependent terahertz spectroscopic experiments. The proposed dual-heater temperature controller based on a cascade proportional-integral-derivative algorithm provides smooth temperature changes in the polyethylene-based pharmaceutical pellet samples. The device has been integrated with a terahertz time-domain spectrometer. Thermodynamic experiments can now be performed without any probe inserted into the measured sample. Selected results of temperature-induced evolution in terahertz spectra are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Convenient determination of luminescence quantum yield using a combined electronic absorption and emission spectrometer

It is possible to measure luminescence quantum yield in a facile way, by designing an optical spectrometer capable of obtaining electronic absorption as well as luminescence spectra, with a setup that uses the same light source and detector for both the spectral measurements. Employment of a single light source and single detector enables use of the same correction factor profile for spectral corrections. A suitable instrumental scaling factor is used for adjusting spectral losses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass separation of deuterium and helium with conventional quadrupole mass spectrometer by using varied ionization energy

Deuterium pressure in deuterium-helium mixture gas is successfully measured by a common quadrupole mass spectrometer (model: RGA200) with a resolution of ∼0.5 atomic mass unit (AMU), by using varied ionization energy together with new developed software and dedicated calibration for RGA200. The new software is developed by using MATLAB with the new functions: electron energy (EE) scanning, deuterium partial pressure measurement, and automatic data saving. RGA200 with new software is calibrated in pure deuterium and pure helium 1.0 × 10{sup −6}–5.0 × 10{sup −2} Pa, and the relation between pressure and ion current of AMU4 under EE = 25 eV and EE = 70 eV is obtained. From the calibration result and RGA200 scanning with varied ionization energy in deuterium and helium mixture gas, both deuterium partial pressures (P{sub D{sub 2}}) and helium partial pressure (P{sub He}) could be obtained. The result shows that deuterium partial pressure could be measured if P{sub D{sub 2}} > 10{sup −6} Pa (limited by ultimate pressure of calibration vessel), and helium pressure could be measured only if P{sub He}/P{sub D{sub 2}} > 0.45, and the measurement error is evaluated as 15%. This method is successfully employed in EAST 2015 summer campaign to monitor deuterium outgassing/desorption during helium discharge cleaning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Indigenous design and development of multiPSD array for time of flight neutron spectrometer

Time of Flight neutron Spectrometer for inelastic neutron scattering studies is being commissioned at Dhruva reactor. Neutron pulse tagging is carried out using the Fermi chopper. Scattered neutrons at maximum possible scattered solid angle are needed to be detected along with the time information at detector. Precise and efficient detection system is essential for measurement of spatial and temporal distribution. Detection area is optimized to cover an angle of 70° in horizontal direction and 23° in vertical direction. Position sensitive detectors (PSDs) are designed with judicial use of precious {sup 3}He gas and a few PSDs with BF{sub 3} gas as suitable alternative for {sup 3}He gas. An array of vertically arranged 1 m long, 50 PSDs, covers the arc length of 2.5 m and detection area 2.5 m{sup 2}. The design of the BF{sub 3} PSDs is supported by investigations on the gas purity, fill gas pressure, drift region, drift field and neutron absorption in cathode wall. Design details and performance of the PSDs are presented in the paper.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗