Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Effect of plasma density scale length on the properties of bremsstrahlung x-ray sources created by picosecond laser pulses

Results of an experimental study of multi-MeV bremsstrahlung x-ray sources created by picosecond laser pulses are presented. The x-ray source is created by focusing the short pulse in an expanding plasma obtained by heating a solid target with a time-delayed nanosecond laser beam. The high-energy part of the x-ray spectrum and emission lobe are inferred from photonuclear activation techniques. The x-ray dose is measured with silicon diodes. Two-dimensional images of the source are reconstructed from a penumbral imaging technique. These results indicate the creation of a relatively small source, below 200 {mu}m diameter, delivering doses up to 12 mrad in air at 1 m with x-ray temperature up to 2.8 MeV. The diagnostics used give access to a whole set of coherent experimental results on the x-ray source properties which are compared to extensive numerical simulations. X-ray intensity and temperature are found to increase with the size of the preplasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed plasma electron sources

There is a continuous interest in research of electron sources which can be used for generation of uniform electron beams produced at E{<=}10{sup 5} V/cm and duration {<=}10{sup -5} s. In this review, several types of plasma electron sources will be considered, namely, passive (metal ceramic, velvet and carbon fiber with and without CsI coating, and multicapillary and multislot cathodes) and active (ferroelectric and hollow anodes) plasma sources. The operation of passive sources is governed by the formation of flashover plasma whose parameters depend on the amplitude and rise time of the accelerating electric field. In the case of ferroelectric and hollow-anode plasma sources the plasma parameters are controlled by the driving pulse and discharge current, respectively. Using different time- and space-resolved electrical, optical, spectroscopical, Thomson scattering and x-ray diagnostics, the parameters of the plasma and generated electron beam were characterized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 {mu}m spot of {approx}5x10{sup 9} photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 {mu}m are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution ({approx}0.2 {mu}m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10{sup -5} strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution ({approx}150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments on the Detection of Negative Hydrogen Ions in a Small-size Tandem Plasma Source

A small-size inductively-driven tandem (two-chamber) plasma source, with a magnetic filter for electron cooling located in the second chamber of the source, is studied experimentally. The results are for the concentration of the negative hydrogen ions in the expanding plasma region of the source and its correlation with the axial variation of the electron density and temperature. The position of the magnetic filter has been varied in the measurements. The obtained spatial distribution of the electron temperature and density is in agreement with theoretical predictions for the operation of the filter. The results suggest that although the detected negative ions are locally produced, the locations of the regions of their effective production in the source--positions of the lowest electron temperature and/or of the highest electron density-are nonlocally formed, not only by the plasma expansion through the magnetic filter but also by plasma expansion from the driver into the second bigger-size chamber of the source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Proposal for a Novel H{sup -} Ion Source Based on Electron Cyclotron Resonance Plasma Heating and Surface Ionization

A design for a novel H{sup -} ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE{sub 111} eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H{sup -} ion beam is further ''self-extracted'' through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H{sup -} ion current, beam emittance and duty factor of the novel source are estimated.

43 PARTICLE ACCELERATORS↗

Measurement of radial and axial high energy x-ray spectra in electron cyclotron resonance ion source plasmas

Radial and axial x-ray measurements of electron cyclotron resonance ion sources operating at microwave frequencies of 6.4 and 14 GHz are presented. Results indicate a greater detected photon energy in the radial direction than the axial direction for both the 6.4 GHz source and the 14 GHz source. It is also seen that the 14 GHz source produces x-rays with higher energies, when compared to the 6.4 GHz source, in both radial and axial directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study for 15-20 mA dc H{sup -} multicusp source

Recently, a new H- source and test stand was developed at CIAE. The design of this new source is based on the experience on our previous 10-15 mA H{sup -} ion source and the source at TRIUMF. Major efforts include the study of the virtual filter magnetic field, confining magnetic field, filament shape and location, the vacuum improvement on the extracting area, the extraction optics, new control and interlock system of the power supplies. More than 15 mA of H-beam was obtained for 36 h with stability of {+-}0.5%. The normalized emittance of 0.48{pi} mm mrad (4 rms normalized emittance) were measured with {approx}8 mA dc beam. Further experimental studies are proceeding in an effort to reach 20 mA with reasonable emittance at this moment. More study plans are conducted, e.g., building a longer source body and using cesium injection to get better emittance, which will be presented as a separate paper at this conference.

43 PARTICLE ACCELERATORS↗

Emittance improvement efforts on the 15-20 mA dc H{sup -} multicusp source

A 15 mA beam from the 15-20 mA dc H{sup -} multicusp source has been obtained at China Institute of Atomic Energy. In order to improve the emittance of extracted beam from this new multicusp source, some measures have been taken, i.e., increasing the length of the ion source body, improving the vacuum in the extraction area, injecting cesium vapor into the ion source, etc. The hardware, including the lengthened source body, the improved back cover and cesium heating system, and the extraction vacuum box, will be described. Initial results for these efforts aimed at emittance improvement will also be given in the paper.

43 PARTICLE ACCELERATORS↗

Design of a compact, permanent magnet electron cyclotron resonance ion source for proton and H{sub 2}{sup +} beam production

A 2.45 GHz microwave ion source was developed at China Institute of Atomic Energy (CIAE) for proton beam production of over 60 mA [B.-Q. Cui, Y.-W. Bao, L.-Q. Li, W.-S. Jiang, and R.-W. Wang, Proceedings of the High Current Electron Cyclotron Resonance (ECR) Ion Source for Proton Accelerator, APAC-2001, 2001 (unpublished)]. For various proton beam applications, another 2.45 GHz microwave ion source with a compact structure is designed and will be built at CIAE as well for high current proton beam production. It is also considered to be used for the test of H{sub 2}{sup +} beam, which could be injected into the central region model cyclotron at CIAE, and accelerated to 5 MeV before extraction by stripping. The required ECR magnetic field is supplied by all the permanent magnets rather than electrical solenoids and six poles. The magnetic field distribution provided by this permanent magnets configuration is a large and uniformly volume of ECR zone, with central magnetic field of a magnitude of {approx}875 Gs[T. Taylor and J. S. C. Wills, Nucl. Instrum. Methods Phys. Res. A 309, 37 (1991)]. The field adjustment at the extraction end can be implemented by moving the position of the magnet blocks. The results of plasma, coupling with 2.45 GHz microwave in the ECR zone inside the ion source are simulated by particle-in-cell code to optimize the density by adjusting the magnetic field distribution. The design configuration of the ion source will be summarized in the paper.

43 PARTICLE ACCELERATORS↗

First operation of the charge-breeder electron-cyclotron-resonance ion source at the Texas A and M Cyclotron Institute

The 14.5 GHz electron-cyclotron-resonance ion source (ECRIS) designed and fabricated specifically for charge breeding has been installed at the Texas A and M University Cyclotron Institute for use in the institute's ongoing radioactive-ion-beam upgrade. The initial testing of the source has just begun with magnetic analysis of the ECRIS beam. The source has only been conditioning for a brief time at low microwave power, and it is continuing to improve. After the source has been conditioned and characterized, charge-breeding trials with stable beams from a singly ionizing source will begin.

43 PARTICLE ACCELERATORS↗

Generation of whistler waves by a rotating magnetic field source

The paper discusses the generation of polarized whistler waves radiated from a rotating magnetic field source created via a novel phased orthogonal two loop antenna. The results of linear three-dimensional electron magnetohydrodynamics simulations along with experiments on the generation whistler waves by the rotating magnetic field source performed in the large plasma device are presented. Comparison of the experimental results with the simulations and linear wave properties shows good agreement. The whistler wave dispersion relation with nonzero transverse wave number and the wave structure generated by the rotating magnetic field source are also discussed. The phase velocity of the whistler waves was found to be in good agreement with the theoretical dispersion relation. The exponential decay rate of the whistler wave propagating along the ambient magnetic field is determined by Coulomb collisions. In collisionless case the rotating magnetic field source was found to be a very efficient radiation source for transferring energy along the ambient magnetic field lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion sources for MedAustron

The MedAustron Ion therapy center will be constructed in Wiener Neustadt (Austria) in the vicinity of Vienna. Its accelerator complex consists of four ion sources, a linear accelerator, a synchrotron, and a beam delivery system to the three medical treatment rooms and to the research irradiation room. The ion sources shall deliver beams of H{sub 3}{sup 1+}, C{sup 4+}, and light ions with utmost reliability and stability. This paper describes the features of the ion sources presently planned for the MedAustron facility, such as ion source main parameters, gas injection, temperature control, and cooling systems. A dedicated beam diagnostics technique is proposed in order to characterize electron cyclotron resonance (ECR) ion beams; in the first drift region after the ion source, a fraction of the mixed beam is selected via moveable aperture. With standard beam diagnostics, we then aim to produce position-dependant observables such as ion-current density, beam energy distribution, and emittance for each charge states to be compared to simulations of ECR e-heating, plasma simulation, beam formation, and transport.

43 PARTICLE ACCELERATORS↗

Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

43 PARTICLE ACCELERATORS↗

Modeling of the rf discharge initiation in a negative ion source

The maintenance free rf ion source is expected to be one of the most promising candidates for the negative ion sources of plasma heating for future fusion reactors. As an alternative to the arc-discharge sources, the rf negative ion sources have been developed for H{sup -} production. In order to make clear the condition for the discharge initiation of the rf source, we are developing a numerical model using the finite difference time domain Monte Carlo method to analyze the electron energy distribution function in rf field. The numerical result shows that the discharge is not successfully initiated due to the wall loss unless the wall potential is considered. More self-consistent model including ion dynamics to evaluate the wall potential and the electron loss at the wall will be needed in the future.

43 PARTICLE ACCELERATORS↗

High homogeneity 25 cm low-energy rf ion source with inherent electron compensation

A 25 cm single-grid low-energy rf ion source with inherent electron compensation is described and characterized. Measurements were carried out using Ar and CF{sub 4} filling gas. The dependence of the ion beam current to the target as well as the current partition between the beam fast and slow ions on the rf discharge pressure for both filling gases is discussed. The unique ability of generation of coinciding ion and electron flows is demonstrated and the measured ion and electron energy distribution functions are presented as well. The developed broad ion beam source is able of providing 0.5-5 mA/cm{sup 2} current density in the low ion energy range of 50-250 eV, with possibility of independent current density and energy control. It is shown that complementing the rf plasma source with a profiling electrode allows for CF{sub 4} ion source operation attaining {+-}5% ion beam uniformity over 250 mm in diameter. The presented CF{sub 4} etching test results exhibit the possibility of highly directional anisotropic Si and SiO{sub 2} etching utilizing the developed single grid rf ion source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An ultra-low energy (30-200 eV) ion-atomic beam source for ion-beam-assisted deposition in ultrahigh vacuum

The paper describes the design and construction of an ion-atomic beam source with an optimized generation of ions for ion-beam-assisted deposition under ultrahigh vacuum (UHV) conditions. The source combines an effusion cell and an electron impact ion source and produces ion beams with ultra-low energies in the range from 30 eV to 200 eV. Decreasing ion beam energy to hyperthermal values ({approx_equal}10{sup 1} eV) without loosing optimum ionization conditions has been mainly achieved by the incorporation of an ionization chamber with a grid transparent enough for electron and ion beams. In this way the energy and current density of nitrogen ion beams in the order of 10{sup 1} eV and 10{sup 1} nA/cm{sup 2}, respectively, have been achieved. The source is capable of growing ultrathin layers or nanostructures at ultra-low energies with a growth rate of several MLs/h. The ion-atomic beam source will be preferentially applied for the synthesis of GaN under UHV conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification Of Cesium In Negative Hydrogen Ion Sources By Laser Absorption Spectroscopy

The use of cesium in negative hydrogen ion sources and the resulting cesium dynamics caused by the evaporation and redistribution in the vacuum and plasma phase makes a reliable and on-line monitoring of the cesium amount in the source highly desirable. For that purpose, a robust and compact laser absorption setup suitable for the ion source environment has been developed utilizing the Cs D{sub 2} resonance line at 852.1 nm. First measurements are taken in a small laboratory plasma chamber with cesium evaporation. A detection limit of {approx_equal}5x10{sup 13} m{sup -3} at a typical path length of 15 cm has been obtained with a dynamic range of more than three orders of magnitude, limited by line saturation at high densities. For on-line monitoring an automatic data analysis is established achieving a temporal resolution of 100 ms. The setup has then been applied to the ITER prototype ion sources developed at IPP. It is been shown that the method is well suited for routine measurements revealing a new insight into the cesium dynamics during source operation and cesium conditioning.

43 PARTICLE ACCELERATORS↗

Recent progress on the superconducting ion source VENUS

The 28 GHz Ion Source VENUS (versatile ECR for nuclear science) is back in operation after the superconducting sextupole leads were repaired and a fourth cryocooler was added. VENUS serves as an R and D device to explore the limits of electron cyclotron resonance source performance at 28 GHz with its 10 kW gryotron and optimum magnetic fields and as an ion source to increase the capabilities of the 88-Inch Cyclotron both for nuclear physics research and applications. The development and testing of ovens and sputtering techniques cover a wide range of applications. Recent experiments on bismuth demonstrated stable operation at 300 e{mu}A of Bi{sup 31+}, which is in the intensity range of interest for high performance heavy-ion drivers such as FRIB (Facility for Rare Isotope Beams). In addition, the space radiation effects testing program at the cyclotron relies on the production of a cocktail beam with many species produced simultaneously in the ion source and this can be done with a combination of gases, sputter probes, and an oven. These capabilities are being developed with VENUS by adding a low temperature oven, sputter probes, as well as studying the RF coupling into the source.

43 PARTICLE ACCELERATORS↗