Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Computational Analysis of the Transonic Dynamics Tunnel Using FUN3D

This paper presents results from an explanatory two-year effort of applying Computational Fluid Dynamics (CFD) to analyze the empty-tunnel flow in the NASA Langley Research Center Transonic Dynamics Tunnel (TDT). The TDT is a continuous-flow, closed circuit, 16- x 16-foot slotted-test-section wind tunnel, with capabilities to use air or heavy gas as a working fluid. In this study, experimental data acquired in the empty tunnel using the R-134a test medium was used to calibrate the computational data. The experimental calibration data includes wall pressures, boundary-layer profiles, and the tunnel centerline Mach number profiles. Subsonic and supersonic flow regimes were considered, focusing on Mach 0.5, 0.7 and Mach 1.1 in the TDT test section. This study discusses the computational domain, boundary conditions, and initial conditions selected in the resulting steady-state analyses using NASA's FUN3D CFD software.

97 MATHEMATICS AND COMPUTING↗

Performance Evaluation of Distributed Energy Resource Management Algorithm in Large Distribution Networks

This paper presents performance evaluation of hierarchical optimization and control for distributed energy resource management system (DERMS) in large distribution networks via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory envi-ronment, including the accurate modeling of a full-scale dis-tribution system of 11,000 nodes, the DERMS software con-troller, and 90 power hardware photovoltaics (PVs) and bat-tery inverters. The applied DERMS algorithm is designed based on a real-time optimal power flow algorithm and im-plemented with acceleration design that performs fast dis-patch of simulated PVs and real physical hardware DER devices every 4 seconds.

distributed energy management system (DERMS)↗

ViBRANT Applied as a Closed Loop Flux and Thermal Surrogate

Surrogate testing platforms provide a means to develop a target aspect of a larger system. Some systems target single aspects while others are more wholistic. ViBRANT (Visual Benign Reactor as Analog for Nuclear Testing) aims to be a wholistic system by representing the primary reactor behaviors through an accessible LED driven reactor core, photodiodes, thermocouples, and high-performance software interfaces being developed to the standards required for actual microreactor deployment such as MARVEL. With the ability to drive control drums enabled with full reactor capability (e.g. speed/angle/torque capability/limits for operation and clutch/spring scram capability), drive ViBRANT’s high fidelity 36 pin hexagon core to represent phenomena via LEDs, and capture the analog response of distributed photodiodes/thermocouples, this paper will show the system’s ability to operate in a closed-loop fashion and do well at matching reactor power/temperature distribution in an accessible reactor surrogate environment.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 3d Raw Data

XPS of Si/GaN photocathode after 1 hour chronoamperometry (CA) testing. Surface chemical composition and valence band structure of GaN were obtained by X-ray photoemission spectroscopy (XPS) on a Kratos Axis Ultra DLD system at a takeoff angle of 0° relative to the surface normal. An Al Kα source (hν = 1486.6 eV) was used to excite the core level electrons. Pass energy of 20 eV was used for the narrow scan of core levels and valence band spectra, and step size of 0.05 eV and 0.025 eV, respectively. The Spectral fitting was conducted using CasaXPS analysis software. The binding energy scales of all core levels were corrected to the N 1s of Ga – N bond at 397.8 eV. X-ray photoemission spectroscopy (XPS) O1s core level spectra from 1 hour chronoamperometry (CA) tested Si/GaN sample, and deconvolution shows O - Ga bond, O - N - Ga bond, and OH - H2O bond.

photocathode↗

SU-E-I-52: Validation of Multi-Frequency Electrical Impedance Tomography Using Computed Tomography

Purpose: Multi-frequency EIT has been reported to be a potential tool in distinguishing a tissue anomaly from background. In this study, we investigate the feasibility of acquiring functional information by comparing multi-frequency EIT images in reference to the structural information from the CT image through fusion. Methods: EIT data was acquired from a slice of winter melon using sixteen electrodes around the phantom, injecting a current of 0.4mA at 100, 66, 24.8 and 9.9 kHz. Differential EIT images were generated by considering different combinations of pair frequencies, one serving as reference data and the other as test data. The experiment was repeated after creating an anomaly in the form of an off-centered cavity of diameter 4.5 cm inside the melon. All EIT images were reconstructed using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) package in 2-D differential imaging mode using one-step Gaussian Newton minimization solver. CT image of the melon was obtained using a Phillips CT Scanner. A segmented binary mask image was generated based on the reference electrode position and the CT image to define the regions of interest. The region selected by the user was fused with the CT image through logical indexing. Results: Differential images based on the reference and test signal frequencies were reconstructed from EIT data. Result illustrated distinct structural inhomogeneity in seeded region compared to fruit flesh. The seeded region was seen as a higherimpedance region if the test frequency was lower than the base frequency in the differential EIT reconstruction. When the test frequency was higher than the base frequency, the signal experienced less electrical impedance in the seeded region during the EIT data acquisition. Conclusion: Frequency-based differential EIT imaging can be explored to provide additional functional information along with structural information from CT for identifying different tissues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Joint Development of SAS4A Code in Application to Oxide-fueled LFR Severe Accident Analysis

The scope of this project was to pursue specific SAS4A liquid-metal cooled reactor (LMR) safety analysis software extensions to simulate postulated accidents with fuel failures for oxide-fueled Lead-cooled Fast Reactors (LFRs). Since most U.S. LMR experience is on sodium-cooled fast reactor options based on past testing and operation experience with EBR-II and FFTF, the DOE’s legacy fast reactor safety analysis capabilities were focused on metal-fueled pool-type concepts with sodium coolant. In recent years, Westinghouse Electric Company (WEC) has decided to pursue an LFR design as one of their next generation nuclear technology options because of its favorable safety and economics attributes. Oxide fuel is considered among other fuel options due to previous WEC experience with this fuel form. Development of this new technology requires the availability of adequately accurate computational tools, some of which can be adapted from versions of similar software used for analysis of other LMRs. Although Argonne National Laboratory’s (ANL) SAS4A/SASSYS-1 safety analysis software suite (shortened as SAS4A code hereafter for brevity) has the basic capabilities to model LFR system designs, the SAS4A code modules used in the analysis of accidents with fuel/cladding failures lack appropriate models for the unique phenomena that govern as-irradiated oxide-fuel damage mechanisms in lead coolant. Therefore, the objective of this project was to extend the capabilities of SAS4A with mechanistic oxide-fuel failure models in lead coolant for margin to failure assessments, analysis of failure modes, location and timing of failures under different accident scenarios consistent with the whole-plant dynamic response including the reactivity feedback, and assessment of the potential for fuel damage propagation due to potential fission gas jet and fuel-fragment/molten fuel impingement to neighboring fuel pins in an assembly. This report provides mainly a summary of Argonne’s technical contributions in the joint project, but the reports and publications by the Participant team are included as references at the end of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Proposed Test Stand Selection Criteria

The Consortium for Advanced Simulation of Light Water Reactors (CASL) is developing modeling and simulation capabilities to provide predictive performance of reactors with a specific focus on several challenge problems to support power uprates, life extension, and use of higher burnup fuels. A critical element of the success of the CASL M&S hub will be the ability to transfer the technology (both methods and software) developed by CASL to external stakeholders (including the industry, regulatory and research communities) and for these stakeholders to apply these methods and tools to address critical issues related to the long-term efficient and safe operation of commercial NPPs. An important element to enable the achievement of this objective is the development and deployment of industry Test Stands, which are intended to serve as a primary mechanism for initial deployment of CASL developed technology to these stakeholders.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Empirical Validation of Building Energy Modeling using Flexible Research Platform

Recently, efforts have been made to provide reliable empirical data for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, to enable improved accuracy of building energy model (BEM) engines and improved characterization of their accuracy. The motivation for this effort is that the use of reliable empirical validation data sets in the evaluation of building energy modeling tools will lead to more consistent and validated simulation engines across all software vendors. This would expedite the use of building energy modeling in designing new buildings and retrofitting existing buildings, which delivers more energy efficient buildings.As part of a three-year multi-lab empirical validation project sponsored by U.S. DOE, this research project generated cooling season test plans by reviewing ASHRAE Standard 140, and the tests were performed based on the test plan. Finally, the experimental data sets were compared with the EnergyPlus model to demonstrate the validation procedure.

Im, Piljae↗

Experiments and Simulation of a Borehole in Salt to Understand Heat, Brine, and Vapor Migration - 19192

Disposition of heat-generating nuclear waste (HGNW) remains a continuing technical and sociopolitical challenge. Numerous concepts for HGNW management have been proposed and examined internationally, including an extensive focus on geologic disposal. One proposed geologic material is salt because of its low permeability and viscoplastic deformation that causes self-repair of damage done to the salt by waste emplacement activities. Evaluating the safety and technical challenges of storing HGNW in a salt repository is an ongoing process involving experiments and supporting numerical simulation. Currently an experiment is underway at the Waste Isolation Pilot Plant (WIPP) to explore how the presence of a heat generating source affects phenomena such as brine migration, vapor transport, and mechanical changes to the bedded salt. A sub-horizontal heated borehole test is in progress in the underground at the WIPP that includes a centrally located 10.2 cm diameter borehole with an adjustable heater surrounded with smaller diameter boreholes instrumented with thermocouples. The central borehole contains an inflatable packer, heating block, brine sampler, and constantly flowing nitrogen gas circulation system. Air-injection tests performed in the central borehole provide pressure measurements that are used to constrain permeability of the system. The steady-state temperatures, as well as the rise and fall of temperature when the heater is cycled on and off, have been measured for up to 60 days. In the borehole, dry nitrogen gas circulation evaporates water and outflows to a desiccant container where water mass is measured daily during the experiment to quantify vapor removal. Although this test is a 'shake-down' for a planned second round of fresh borehole testing, we have gathered a rich dataset. These data allow us to build simulations using the Finite Element Heat and Mass transfer code (FEHM) to evaluate the experimental results, determine field-scale parameters, and identify code improvements to reproduce important physical processes that may not be accounted for at present. A 3-D numerical mesh, built using LaGrit software (lagrit.lanl.gov; Miller et al., 2007), includes increasing resolution around the central borehole. Modeling of the experiment allows for determining the local thermal conductivity and permeability of any damaged bedded salt around the borehole, where damage from drilling may change the permeability, porosity and saturation conditions, by parameter testing and inverse methods. Additionally, assumptions about brine and vapor flow and transport are being tested by comparing measured and simulated results. The combination of experimental data and model results provide additional data to help support the safety case for safe and effective HGNW disposition in bedded salt formations. Initial results from this experiment show that water flow into the borehole is within previous experimental results. Further, we have found that the design of the heater block is restricting energy to flow into the rock salt. Thus, this test has proven useful in design of the next generation experiment where infrared heating may be used to bypass issues caused by air gaps located around the current stainless steel block heater. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Liquid argon scintillation light studies in LArIAT

The LArIAT experiment is using its Liquid Argon Time Projection Chamber (LArTPC) in the second run of data-taking at the Fermilab Test Beam Facility. The goal of the experiment is to study the response of LArTPCs to charged particles of energies relevant for planned neutrino experiments. In addition, it will help to develop and evaluate the performance of the simulation, analysis, and reconstruction software used in other LAr neutrino experiments. Particles from a tertiary beam detected by LArIAT (mainly protons, pions and muons) are identified using a set of beamline detectors, including Wire Chambers, Time of Flight counters and Cherenkov counters, as well as a simplified sampling detector used to detect muons. In its effort towards augmenting LArTPC technology for other neutrino experiments, LArIAT also takes advantage of the scintillating capabilities of LAr and is testing the possibility of using the light signal to help reconstruct calorimetric information and particle ID. In this study, we present results from these studies of the scintillation light signal to evaluate detector performance and calorimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Weapon Physicist Declassifies Rescued Nuclear Test Films

The U.S. conducted 210 atmospheric nuclear tests between 1945 and 1962, with multiple cameras capturing each event at around 2,400 frames per second. But in the decades since, around 10,000 of these films sat idle, scattered across the country in high-security vaults. Not only were they gathering dust, the film material itself was slowly decomposing, bringing the data they contained to the brink of being lost forever. For the past five years, Lawrence Livermore National Laboratory (LLNL) weapon physicist Greg Spriggs and a crack team of film experts, archivists and software developers have been on a mission to hunt down, scan, reanalyze and declassify these decomposing films. The goals are to preserve the films’ content before it’s lost forever, and provide better data to the post-testing-era scientists who use computer codes to help certify that the aging U.S. nuclear deterrent remains safe, secure and effective.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-361: Energy Dependent Radiation/light-Field Misalignment On Truebeam Linear Accelerator

Purpose: Verifying the co-incidence of the radiation and light field is recommended by TG-142 for monthly and annual checks. On a digital accelerator, it is simple to verify that beam steering settings are consistent with accepted and commissioned values. This fact should allow for physicists to verify radiation-light-field co-incidence for a single energy and accept that Result for all energies. We present a case where the radiation isocenter deviated for a single energy without any apparent modification to the beam steering parameters. Methods: The radiation isocenter was determined using multiple Methods: Gafchromic film, a BB test, and radiation profiles measured with a diode. Light-field borders were marked on Gafchromic film and then irradiated for all photon energies. Images of acceptance films were compared with films taken four months later. A phantom with a radio-opaque BB was aligned to isocenter using the light-field and imaged using the EPID for all photon energies. An unshielded diode was aligned using the crosshairs and then beam profiles of multiple field sizes were obtained. Field centers were determined using Omni-Pro v7.4 software, and compared to similar scans taken during commissioning. Beam steering parameter files were checked against backups to determine that the steering parameters were unchanged. Results: There were no differences between the configuration files from acceptance. All three tests demonstrated that a single energy had deviated from accepted values by 0.8 mm in the inline direction. The other two energies remained consistent with previous measurements. The deviated energy was re-steered to be within our clinical tolerance. Conclusions: Our study demonstrates that radiation-light-field coincidence is an energy dependent effect for modern linacs. We recommend that radiation-light-field coincidence be verified for all energies on a monthly basis, particularly for modes used to treat small fields, as these may drift without influencing results from other tests.

60 APPLIED LIFE SCIENCES↗

Electrical design analysis and breakdown voltage test aspects of indigenously developed electrical breaks at Cryo temperatures

Electrical insulation breaks are very critical component of large-scale fusion devices employing superconducting magnets and are used to insulate electrically the coil and the cryogenic supply line (kept at ground potential). The electrical insulation of breaks consists of the composites insulations, G-10 GFRP (Glass fiber reinforced plastic), cryogenic compatible epoxy and S-glass boron free fiber in air and helium environment under vacuum. To optimize the design parameters, the detailed electrical analysis have been carried out using the electrostatic solid axi-symmetric model by COMSOL 4.1 multiphysics software for electrodes separation, electrical field strength as well as flashover phenomenon between two electrodes with composite insulator material have been analyzed at different surfaces and contours along with by varying gaps between SS electrodes. We have carried out the high voltage breakdown test (0-35) kV, insulation resistance measurement at 0-5 kV test voltage in Paschen condition of (10{sup 3} -10{sup -5}) mbar in helium gas and air environment at 300 K and 77 K experimentally on in-house developed insulation breaks. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

OSIRIS User's Manual, v. 1.0

The On-Site Inspection RadioIsotopic Spectroscopy (OSIRIS) system is a gamma-ray spectroscopy instrument for on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). [1] OSIRIS identifies fission-product isotopes with a high-resolution gamma-ray spectrometer. The spectrometer is controlled by a ruggedized notebook computer running data acquisition and data analysis software customized for CTBT on-site inspections. This manual explains OSIRIS preparation and setup for operation; startup procedures, including energy-calibration of the spectrometer; spectral measurements and spectral analyses; and shutdown procedures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗