Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Separation of a Set of Peptide Sequence Isomers Using Differential Ion Mobility Spectrometry

Protein identification in bottom-up proteomics requires disentangling isomers of proteolytic peptides, a major class of which are sequence inversions. Separation of sequence isomers using ion mobility spectrometry (IMS) has been reported, but limited to pairs of species. Here we demonstrate baseline separation of all seven sequences for a tryptic peptide with eight residues using differential IMS or FAIMS. Evaluations of peak capacity of the method indicate that even larger libraries should generally be separated for heavier peptides with higher charge states.

59 BASIC BIOLOGICAL SCIENCES↗

Automated Radioanalytical System Incorporating Microwave-Assisted Sample Preparation, Chemical Separation, and Online Radiometric Detection for the Monitoring of Total 99Tc in Nuclear Waste Processing Streams

An automated fluidic instrument is described that rapidly determines the total 99Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the 99Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of 99Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of 99Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward ‘Omic Scale Metabolite Profiling: A Dual Separation–Mass Spectrometry Approach for Coverage of Lipid and Central Carbon Metabolism

Although the objective of any ‘omic science is broad measurement of its constituents, such coverage has been challenging in metabolomics because the metabolome is comprised of a chemically diverse set of small molecules with variable physical properties. While extensive studies have been performed to identify metabolite isolation and separation methods, these strategies introduce bias toward lipophilic or water-soluble metabolites depending on whether reversed-phase (RP) or hydrophilic interaction liquid chromatography (HILIC) is used, respectively. Here we extend our consideration of metabolome isolation and separation procedures to integrate RPLC/MS and HILIC/MS profiling. An aminopropyl-based HILIC/MS method was optimized on the basis of mobile-phase additives and pH, followed by evaluation of reproducibility. When applied to the untargeted study of perturbed bacterial metabolomes, the HILIC method enabled the accurate assessment of key, dysregulated metabolites in central carbon pathways (e.g., amino acids, organic acids, phosphorylated sugars, energy currency metabolites), which could not be retained by RPLC. To demonstrate the value of the integrative approach, bacterial cells, human plasma, and cancer cells were analyzed by combined RPLC/HILIC separation coupled to ESI positive/negative MS detection. In this work, the combined approach resulted in the observation of metabolites associated with lipid and central carbon metabolism from a single biological extract, using 80% organic solvent (ACN:MeOH:H2O 2:2:1). It enabled the detection of more than 30,000 features from each sample type, with the highest number of uniquely detected features by RPLC in ESI positive mode and by HILIC in ESI negative mode. Therefore, we conclude that when time and sample are limited, the maximum amount of biological information related to lipid and central carbon metabolism can be acquired by combining RPLC ESI positive and HILIC ESI negative mode analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of Protein Conformers by Differential Ion Mobility in Hydrogen-Rich Gases

Proteins in solution or the gas phase tend to exhibit multiple conformational families, each comprising distinct structures. Separation methods have generally failed to resolve these, with their convolution producing wide peaks. Here we report full separation of >10 conformers for most ubiquitin charge states by the new approach of differential ion mobility spectrometry (FAIMS) employing H 2 /N 2 gas mixtures with up to 85% H 2 . The resolving power (up to 400) is five times the highest previously achieved (using He/N 2 buffers), greatly increasing the separation specificity. The peak widths match the narrowest obtained by FAIMS for any species under same conditions and scale with the protein charge state (z) and ion residence time (t) as z-1/2 and t-1/2, as prescribed for instrumental (diffusional) broadening. This suggests resolution of specific geometries rather than broader ensembles.

08 HYDROGEN↗

Ultrahigh-Resolution Differential Ion Mobility Separations of Conformers for Proteins above 10 kDa: Onset of Dipole Alignment?

Biomacromolecules tend to assume numerous structures in solution or the gas phase. It has been possible to resolve disparate conformational families but not unique geometries within each, and drastic peak broadening has been the bane of protein analyses by chromatography, electrophoresis, and ion mobility spectrometry (IMS). The new differential IMS (FAIMS) approach using hydrogen-rich gases was recently found to separate conformers of a small protein ubiquitin with same peak width and resolving power up to ~400 as for peptides. Present work explores the reach of this approach for larger proteins, exemplified by cytochrome c and myoglobin. Resolution similar to that for ubiquitin was largely achieved with longer separations, while the onset of peak broadening and coalescence with shorter separations suggests the limitation of present technique to proteins under ~20 kDa. This capability may enable distinguishing whole proteins with differing residue sequences or localizations of posttranslational modifications. Small features at negative compensation voltages that markedly grow from cytochrome c to myoglobin indicate the dipole alignment of rare conformers in accord with theory, further supporting the concept of pendular macroions in FAIMS.

Environmental Molecular Sciences Laboratory↗

Aerosol Optical Tweezers Elucidate the Chemistry, Acidity, Phase Separations, and Morphology of Atmospheric Microdroplets

Aerosol particles represent unique chemical environments because of their high surface area-to-volume ratio that promotes the effects of interfacial chemistry in confined environments. Properties such as viscosity, diffusivity, water content, pH, and morphology—following liquid–liquid phase separation—can strongly alter how a particle interacts with condensable vapors and reactive trace gases, thus modifying its continual evolution and environmental effects. Our understanding of this chemical evolution of atmospheric particulate matter and its environmental impacts is largely limited by our ability to directly observe how these critical particle properties respond to the addition or reactive uptake of new chemical components. Aerosol optical tweezers (AOT) stably trap particles in focused laser beams, providing positional control and the retrieval of many of these critical properties required to understand and predict the chemistry of aerosolized microdroplets. The analytical power of the AOT stems from the retrieval of the cavity-enhanced Raman spectrum induced by the trapping laser. Analysis of the whispering gallery modes (WGMs) that resonate as a standing wave around the droplet’s interface, provide high accuracy measurements of the droplet’s size, refractive index (and thus a measurement of composition), and can distinguish between core–shell, partially engulfed, and homogeneous morphologies. In this study, we have advanced the ability to determine the properties of the core and shell phases in biphasic droplets, including obtaining high-accuracy pH measurements. These capabilities were applied to perform AOT physical chemistry experiments on authentic secondary organic aerosol (SOA) produced directly in the AOT chamber by ozonolysis of terpene vapors. The propensity of the SOA to phase separate as a shell from a wide range of nonpolar to polar core phases was observed, along with the discovery of a stable emulsified state of SOA particles in an aqueous salt droplet. Micron-thick SOA shells did not impede the gain or loss of water or squalane from the core to the surrounding air, indicating no significant diffusional limitations to condensational growth or partitioning even under dry conditions. These experiments formed the foundation of a new framework that predicts how the phase-separated morphology of complex aerosols containing organic carbon evolves during continual atmospheric oxidation processes. Increases in oxidation state will quickly drive conversion from a partially engulfed to core–shell morphology that has dramatically different chemical reactivity since the core phase is completely concealed by the shell. The recent advances in the experimental capabilities of the AOT technique such as presented here enable novel experimental methodologies that provide insights into the chemistry and multidimensional properties of aerosol microdroplets, and how these coevolve and respond to continual chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using a Chromatographic Pseudophase Model To Elucidate the Mechanism of Olefin Separation by Silver(I) Ions in Ionic Liquids

Silver(I) ions undergo selective olefin complexation and have been utilized in various olefin/paraffin separation techniques such as argentation chromatography and facilitated transport membranes. Ionic liquids (ILs) are solvents known for their low vapor pressure, high thermal stability, low melting points, and ability to promote a favorable solvation environment for silver(I) ion–olefin interactions. To develop highly selective separation systems, a fundamental understanding of analyte partitioning to the stationary phase and the thermodynamic driving forces behind solvation is required. In this study, a chromatographic model treating silver(I) ions as a pseudophase is constructed and employed for the first time to investigate the olefin separation mechanism in silver(I) salt/IL mixtures. Stationary phases containing varying amounts of noncoordinated silver(I) salt ([Ag + ][NTf 2 – ]) dissolved in the 1-decyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 10 MIM + ][NTf 2 – ]) IL are utilized to determine the partition coefficients of various analytes including alkanes, alkenes, alkynes, aromatics, aldehyde, esters, and ketones. As ligand coordination to silver(I) ions is known to lower its olefin complexation capability, this study also examines two different types of coordinated silver(I) ion pseudophases, namely, monocoordinated silver(I) salt ([Ag + (1-decyl-2-methylimidazole, DMIM)][NTf 2 – ]) and dicoordinated silver(I) salt ([Ag + (1-methylimidazole, MIM)(DMIM)][NTf 2 – ]). The extent of olefin partitioning to the coordinated silver(I) ion pseudophases over the carrier gas and IL decreased by up to two orders of magnitude. Values for enthalpy, entropy, and free energy of solvation were determined for the three silver(I) ion-containing systems. Olefin retention was observed to be enthalpically dominated, while ligand coordination to the silver(I) ion pseudophase resulted in variations for both enthalpic and entropic contributions to the free energy of solvation. Furthermore, the developed model can be used to study chemical changes that occur in silver(I) ions over time as well as identify optimal silver(I) salt/IL mixtures that yield high olefin selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Traveling Wave Ion Mobility Separations in Structures for Lossless Ion Manipulations

We report on the development and characterization of a new traveling wave-based Structure for Lossless Ion Manipulations (TW-SLIM) for ion mobility separations (IMS). The TW-SLIM module uses parallel arrays of rf electrodes on two closely spaced surfaces for ion confinement, where the rf electrodes are separated by arrays of short electrodes, and using these TWs can be created to drive ion motion. In this initial work, TWs are created by the dynamic application of dc potentials. The capabilities of the TW-SLIM module for efficient ion confinement, lossless ion transport, and ion mobility separations at different rf and TW parameters are reported. The TW-SLIM module is shown to transmit a wide mass range of ions (m/z 200–2500) utilizing a confining rf waveform (~1 MHz and ~300 V p-p ) and low TW amplitudes (<20 V). Additionally, the short TW-SLIM module achieved resolutions comparable to existing commercially available low pressure IMS platforms and an ion mobility peak capacity of ~32 for TW speeds of <210 m/s. TW-SLIM performance was characterized over a wide range of rf and TW parameters and demonstrated robust performance. In conclusion, the combined attributes of the flexible design and low voltage requirements for the TW-SLIM module provide a basis for devices capable of much higher resolution and more complex ion manipulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Achieving High Resolution Ion Mobility Separations Using Traveling Waves in Compact Multiturn Structures for Lossless Ion Manipulations

We report on ion mobility separations (IMS) achievable using traveling waves in a Structures for Lossless Ion Manipulations (TW-SLIM) module having a 44-cm path length and sixteen 90º turns. The performance of the TW-SLIM module was evaluated for ion transmission, and ion mobility separations with different RF, TW parameters and SLIM surface gaps in conjunction with mass spectrometry. In this work TWs were created by the transient and dynamic application of DC potentials. The TW-SLIM module demonstrated highly robust performance and the ion mobility resolution achieved even with sixteen close spaced turns was comparable to a similar straight path TW-SLIM module. We found an ion mobility peak capacity of ~ 31 and peak generation rate of 780 s-1 for TW speeds of <210 m/s using the current multi-turn TW-SLIM module. The separations achieved for isomers of peptides and tetrasaccharides were found to be comparable to those from a ~ 0.9-m drift tube-based IMS-MS platform operated at the same pressure (4 torr). The combined attributes of flexible design, low voltage requirements and lossless ion transmission through multiple turns for the present TW-SLIM module provides a basis for SLIM devices capable of achieving much greater ion mobility resolutions via greatly extended ion path lengths and compact serpentine designs that do not significantly impact the instrumentation profile, a direction described in a companion manuscript.

Environmental Molecular Sciences Laboratory↗

Rapid Ion Mobility Separations of Bile Acid Isomers Using Cyclodextrin Adducts and Structures for Lossless Ion Manipulations

Bile acids (BAs) constitute an important class of steroid metabolites with changes implicated in disease states and other health conditions. Current analyses for these structurally similar compounds are limited by a lack of sensitivity, and long separation times with often poor isomeric resolution. To overcome these challenges and provide rapid analyses for the BA isomers, we utilized cyclodextrin adducts and ion mobility (IM) separations in structures for lossless ion manipulations (SLIM). Cyclodextrin was found to interact with both the tauro- and glyco-conjugated BA isomers studied, forming rigid noncovalent host-guest inclusion complexes. SLIM capabilities for the accumulation of large ion populations and peak compression, enabled both the sensitive detection and high-resolution separation of all the isomers studied.

Chouinard, Christopher D.↗

Exploiting the Dynamic Relationship between Peptide Separation Quality and Peptide Coisolation in a Multiple-Peptide Matches-per-Spectrum Approach Offers a Strategy To Optimize Bottom-Up Proteomics Throughput and Depth

We present that peptide cofragmentation leads to chimeric MS/MS spectra that negatively impact traditional single-peptide match-per-spectrum (sPSM) search strategies in proteomics. The collection of chimeric spectra is influenced by peptide coelution and the width of precursor isolation windows. Although peptide cofragmentation can be reduced by advanced chromatography, such as UHPLC and 2D-HPLC separation schemes, and narrower isolation windows, chimeric spectra can still be as high as 30–50% of the total MS/MS spectra collected. Alternatively, cofragmented peptides in chimeric spectra and the use of wider isolation windows benefit multiple-peptide matches-per-spectrum (mPSM) algorithms, such as CharmeRT, which facilitate the identification of several cofragmented peptides. Considering recent advancements in LC and mPSM methodologies, we present a comprehensive examination of the levels of chimeric spectra collected in the analysis of a HeLa digest measured using different LC modes of separation and isolation windows and compare the depth of identifications obtained when these data are annotated using a sPSM or a mPSM approach. Our results demonstrate that MS/MS data derived from 1D-HPLC strategies under different gradient schemes and searched with CharmeRT yielded higher average numbers of PSMs (11%–49%), peptide analytes (10%–16%), and peptide sequences (3%–10%) compared to data derived from 1D-UHPLC runs but searched with a sPSM strategy. Interestingly, data from a 2D-HPLC separation strategy benefits more from the application of CharmeRT results when compared to a 50 cm 1D-UHPLC column employing a 500 min gradient. In conclusion, these results provide new insights into how to better configure LC-MS/MS measurements for improved throughput and peptide identification in complex proteomes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functionalization of Electrodes with Tunable [EMIM] x [Cl] x +1 – Ionic Liquid Clusters for Electrochemical Separations

Functionalization of electrodes with clusters of hydrophobic molecules may improve the energy efficiency and selectivity of electrochemical separations by modulating the desolvation process occurring at the interface. Ionic liquids (IL), which have a broad range of compositions and properties, are potential candidates for controlling the transport, desolvation, and adsorption of target ions at electrochemical interfaces. We report a joint experimental and theoretical investigation of the structure, stability, and selective adsorption properties of the IL clusters 1-ethyl-3-methylimidazolium chloride [EMIM] x [Cl] x+1 - (x = 1 – 10) and demonstrate their ability to adsorb and separate ions from solution. The structure and stability of the IL clusters are determined experimentally using high-mass-resolution electrospray ionization mass spectrometry, collision-induced dissociation, and negative ion photoelectron spectroscopy. Global optimization theory and ab initio molecular dynamics simulations provide molecular-level insight into the bonding and structural fluxionality of these species. Ion soft landing is used to selectively functionalize the surface of highly oriented pyrolytic graphite (HOPG) working electrodes with [EMIM] 1 [Cl] 2 - , [EMIM] 3 [Cl] 4 - , and [EMIM] 5 [Cl] 6 - clusters. Kelvin probe microscopy provides insight into the relative stability of the clusters on HOPG and their effect on the work function of IL-functionalized electrodes. Cyclic voltammetry measurements reveal irreversible adsorption of Fe(CN) 6 4-/3- anions during redox cycling, while electrochemical impedance spectroscopy indicates a substantial decrease in the electron transfer resistance of the IL-functionalized electrodes due to adsorption of Fe(CN) 6 4-/3- . Overall, our findings demonstrate that IL clusters with different size and stoichiometry may be used to increase the efficiency of electrochemical separations, opening new horizons in selective electrode functionalization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and Characterization of Macrocyclic Ionic Liquids for CO 2 Separation

In this work, a series of ionic liquids with symmetric, macrocyclic cations composed of N-heterocycles connected by alkyl or ether linkages coupled with bis(trifluoromethylsulfonyl)imide or bis(pentafluoroethanesulfonyl)amide anions were synthesized to explore their application in CO 2 separation. These novel ionic liquids showed selective physical absorption of CO 2 compared to N 2 making them potential candidates for carbon capture. We examined the effect of cation structure on the physicochemical and separations properties of the ionic liquid and showed that these ionic liquids exhibit an inverse relationship between molar volume and CO 2 sorption capacity following the trend predicted by models based on regular solution theory. The fractional free volumes of the ionic liquids were lower than typical alkyl-imidazolium ionic liquids despite the cyclic structure of the cations which could be related to the flexibility of the alkyl and ether linkages. These results provide added insight into our understanding of structure–property relationships in CO 2 solubility in ionic liquids and afford a path toward enhancing the separations properties based on structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Designs of Hydrogen Isotope Separation Columns by Numerical Modeling

Mixtures of gas-phase hydrogen isotopologues (diatomic combinations of protium, deuterium, and tritium) can be separated using columns containing a solid such as palladium that reversibly absorbs hydrogen. A temperature-swing process can transport hydrogen into or out of a column by inducing temperature-dependent absorption or desorption reactions. Here, we consider two designs: a thermal cycling absorption process, which moves hydrogen back and forth between two columns, and a simulated moving bed (SMB), where columns are in a circular arrangement. We present a numerical mass and heat transport model of absorption columns for hydrogen isotope separation. It includes a detailed treatment of the absorption–desorption reaction for palladium. By comparing the isotope concentrations within the columns as a function of position and time, we observe that SMB can lead to sharper separations for a given number of thermal cycles by avoiding the remixing of isotopes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrically Powered High-Salinity Brine Separation Using Dimethyl Ether

Dewatering highly saline aqueous streams, from mining and geothermal leachates to industrial wastewater, is essential for effective resource recovery and safe disposal. Membraneless water extraction (MWE) uses a low-polarity solvent to separate water from concentrated aqueous solutions. In this study, we design a new MWE that uses dimethyl ether (DME) to selectively extract water from high-salinity brines, leveraging the volatility of DME to achieve rapid solvent recovery. By separating water and dissolved salts at a liquid–liquid interface, MWE minimizes the deleterious effects of scaling on vulnerable membrane and heat exchanger surfaces, reducing the need for extensive pretreatment and expensive materials. We begin by developing a computational framework for a multistage counterflow liquid–liquid contactor, which extracts water into DME, coupled with a multistage solvent regenerator that uses vapor compression to efficiently separate the desalinated water from the DME extractant. Excess Gibbs free energy and equation of state frameworks are used to model fluid phase equilibria in water–DME–sodium chloride (NaCl) mixtures, with interaction parameters estimated from experimental data. Incorporating equilibrium calculations into a system-scale computational model, we examine the performance of MWE using DME for the first time. Our analysis demonstrates that MWE can concentrate seawater desalination brine (>1.0 mol NaCl kg –1 ) to zero-liquid discharge salinities, with an energy consumption of under 50 kW h per m 3 of water extracted with a solvent recovery ratio greater than 99.9%. We highlight the importance of staging the vapor compression process to simultaneously minimize energy consumption while enabling brine concentration and product water solvent contamination. Finally, the thermodynamic framework developed here allows for the robust evaluation of new MWE solvents and systems for critical brine concentration and fractional precipitation applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗