Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pv module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,538 records · Page 86

Tracking the Sun: Installed Price Trends for Distributed Photovoltaic Systems in the United States - 2018 Edition

Berkeley Lab’s Tracking the Sun report series is dedicated to summarizing installed prices and other trends among grid-connected, distributed solar photovoltaic (PV) systems in the United States. The present report, the 11th edition in the series, focuses on systems installed through year-end 2017, with preliminary trends for the first half of 2018. As in years past, the primary emphasis is on describing changes in installed prices over time and variation in pricing across projects based on location, project ownership, system design, and other attributes. New to this year, however, is an expanded discussion of other project characteristics in the large underlying data sample. Future editions will include more of such material, beyond the report’s traditional focus on installed pricing. The trends described in this report derive primarily from project-level data reported to state agencies and utilities that administer PV incentive programs, solar renewable energy credit (SREC) registration systems, or interconnection processes. In total, data were collected and cleaned for more than 1.3 million individual PV systems, representing 81% of U.S. residential and non-residential PV systems installed through 2017. The analysis of installed pricing trends is based on a subset of roughly 770,000 systems with available installed price data. Key findings from this year’s report include the following: -Installed Prices Continued to Fall through 2017 and into 2018. National median installed prices in 2017 were $3.7 per watt (W) for residential systems (a $0.2/W or 6% decline from the prior year), $3.1/W for small non-residential systems (a $0.4/W or 11% decline), and $2.2/W (a $0.1/W or 5% decline) for large non-residential systems. Data for the first half of 2018 show an additional drop of $0.1/W for residential and small non-residential systems, and effectively no change for large non-residential systems. These recent trends are generally consistent with the pace of price declines since 2014, and mark a slowing from the years immediately preceding (2009-2013) when prices fell by roughly $1/W per year. -Installed Prices Vary Widely Across Individual Projects. Among residential systems installed in 2017, 20% were priced below $3.0/W (the 20th percentile value) while another 20% were above the 80th percentile at $4.5/W. Non-residential systems also exhibit wide spreads, albeit shifted downward, from $2.4/W to $4.1/W for small non-residential and from $1.8/W to $2.8/W for large non-residential projects. These pricing spreads have persisted over time and are both reflective of the heterogeneity in PV systems and markets, as well as suggestive of the potential for further price declines. -Pronounced Pricing Disparities Exist Across States. State-level median installed prices in 2017 ranged from $2.6/W to $4.5/W for residential systems, from $2.2/W to $4.0/W for small non-residential systems, and from $2.1/W to $2.4/W for large non-residential systems. Three of the largest state markets (California, Massachusetts, and New York) are relatively high-priced, pulling overall U.S. median prices upward. These cross-state pricing differences reflect both idiosyncratic features of particular states as well as more-fundamental differences related to market and policy conditions. -Installed Pricing Variation Also Reflects Differences in System Design, Installer, and Customer Characteristics (among other factors). Significant pricing differences were also observed across system sizes within each customer segment (with median prices ranging from $3.2/W to $4.5/W across residential systems of varying size, and from $2.1/W to $3.7/W across non-residential systems), between third-party owned (TPO) and host-owned residential systems ($3.3/W vs. $3.8/W), across residential installers ($2.1/W to $9.6/W for host-owned systems and $1.1/W to $5.1/W for TPO systems), between residential new construction and retrofit systems in California ($2.3/W vs. $3.9/W), between large non-residential systems at commercial sites and tax-exempt customer sites ($2.1/W vs. $2.6/W), and between systems with standard vs. premium efficiency modules ($3.6/W vs. $4.2/W among residential systems). A public version of the underlying dataset can be downloaded at https://emp.lbl.gov/tracking-the-sun.

14 SOLAR ENERGY↗

Atomic structure of light-induced efficiency-degrading defects in boron-doped Czochralski silicon solar cells

Boron-doped Czochralski (Cz) Si is the most commonly used semiconductor in the fabrication of solar cells. The minority carrier lifetime of boron-doped Cz Si decreases upon exposure to light due to B–O-related defects, which reduce the performance of ~10 9 solar modules worldwide. Using electron paramagnetic resonance (EPR), we have identified the spin-active paramagnetic signatures of this phenomenon and gained insights into its microscopic mechanism. We found a distinct defect signature, which diminished when the degraded sample was annealed. The second signature, a broad magnetic field spectrum, due to the unionized B acceptors, was present in the annealed state but vanished upon light exposure. These observations show that, on degradation, nearly all the ~10 16 cm –3 B atoms in Cz Si complexed with interstitial O atoms, whereas only ~10 12 cm –3 of these complexes created defects that were recombination-active. The formation rate of these recombination-active defects correlated with the decay of the minority carrier lifetime. Furthermore, the line shape parameters linked these defects to both B and O impurities in Cz Si.

14 SOLAR ENERGY↗

Encapsulant Adhesion to Surface Metallization on Photovoltaic Cells

Delamination of encapsulant materials from PV cell surfaces often appears to originate at regions with metallization. Using a fracture mechanics based metrology, the adhesion of EVA encapsulant to screen printed silver metallization was evaluated. At room temperature, the fracture energy, G c [J/m 2 ], of the EVA/silver interface (952 J/m 2 ) was ~70% lower than that of the EVA/AR coating (>2900 J/m 2 ) and ~60% lower than that of the EVA to the surface of cell (2265 J/m 2 ). After only 300 hours of damp heat aging, the adhesion energy of the silver interface dropped to and plateaued at ~50-60 J/m 2 , while that of the EVA/AR coating and EVA/cell remained mostly unchanged. Elemental surface analysis showed that the EVA separates from the silver in a purely adhesive manner, indicating that bonds at the interface were likely displaced in the presence of humidity and chemical byproducts at elevated temperature, which in part accounts for the propensity of metallized surfaces to delaminate in the field.

14 SOLAR ENERGY↗

Temperature-Dependent Measurements of an Inverted Metamorphic Multijunction (IMM) Solar Cell: Preprint

The inverted metamorphic multijunction (IMM) solar cell has demonstrated efficiencies as high as 40.8% at 25 degrees C and 326 suns concentration. The actual operating temperature in a commercial module, however, is likely to be as much as 50-70 degrees C hotter, reaching as high as 100 degrees C. In order to be able to evaluate the cell performance under these real-world operating conditions, wehave measured the open-circuit voltage, short-circuit current density and efficiency at temperatures up to 125 degrees C and concentrations up to 1000 suns, as well as the temperature coefficients of these parameters. Spectral response and one-sun current-voltage characteristics were measured by carefully adjusting the incident spectrum to selectively current-limit the different subcells.Concentrator measurements were taken on a pulsed solar simulator to minimize any additional heating due to the high intensity illumination. We compare our measured values to predictions based on detailed models of various triple junction solar cells. By choosing the optimum bandgaps for high temperature operation, the IMM can potentially result in greater energy production and lower temperaturesensitivity under real operating conditions than a Ge-based solar cell.

14 SOLAR ENERGY↗

Large-Area Material and Junction Damage in c-Si Solar Cells by Potential-Induced Degradation

A new potential-induced degradation (PID) mechanism for c-Si is reported. Multiple characterization techniques in various aspects of a material's chemical, structural, electrical, and optoelectrical nature, as well as in atomic, nanometer, micrometer, millimeter, and cell and module scales, are combined. All results point consistently to a new discovery: substantial large-area deterioration of materials and junctions plays a major role.

14 SOLAR ENERGY↗

Characterization of dangling bond defects at the crystalline Si/SiO x interface in a polycrystalline Si passivating contact solar cell at room temperature with electrically detected magnetic resonance spectroscopy

Monocrystalline silicon solar cells can achieve photoconversion efficiencies exceeding 26%; however, performance-limiting defects that trap carriers continue to be a challenge. In this work, we have characterized Si solar cells with tunneling SiO x /polycrystalline-Si (poly-Si) passivating contacts (TOPCon) on As-doped Czochralski Si wafers with electrically detected magnetic resonance (EDMR) spectroscopy. We fabricated 2 × 20 mm 2 TOPCon-like mini solar cells with edge passivation alongside larger 4 cm 2 sister cells and obtained similar device characteristics. We performed EDMR spectroscopy at 300 K on two minicells with different degrees of surface passivation based on the recombination parameter, J o , values of 40 and 310 fA/cm2. We optimized the resolution and the signal-to-noise ratio of the EDMR response of the minicells by varying the forward bias voltage and the magnetic field modulation amplitude. We detect two distinct signals with EDMR spectroscopy, an axial-like signal at g = 2.009, 2.0087, and 2.0015, and an isotropic signal at g = 2.0024, which we attribute to Si dangling bonds (P b0 and P b centers) and boron–oxygen related defects, respectively, at or near the c-Si/SiO x interface. The EDMR signals were lower for the cell with a lower value of J o , while the ratio of the two defect populations was very similar. The EDMR signal increases with forward bias but drops to zero at bias voltages >0.5 V, consistent with interface defects within or near the boron-doped emitter depletion region. Our study demonstrates a method to fabricate minicells that can be characterized with EDMR spectroscopy to detect industrially relevant defects in TOPCon cells.

14 SOLAR ENERGY↗

Understanding the Mechanism of Light and Elevated Temperature Induced Degradation of p-type Silicon Solar Cells (Final Report)

Light- and elevated-temperature-induced degradation (LeTID) was first discovered in multicrystalline Si (mc-Si) solar cells and was initially attributed to metal impurities. Later, LeTID was reported in Czochralski (Cz) and float-zone (FZ) Si, and is considered as an important efficiency loss mechanism in p-type passivated emitter rear contact (p-PERC) Cz Si solar cells. LeTID causes ~10% relative and permeant efficiency losses in these cells in warmer climate regions where the module temperature is > 50 °C. Unlike light-induced degradation (LID), which is also observed in p-PERC cells, LeTID is slower and takes weeks to months in the field to saturate. Another difference compared to LID is that regeneration in LeTID proceeds very slowly, and field regeneration could take > 25 years — essentially the life of the module. Unlike B-O defects that are responsible for LID, neither B nor O impurities are directly involved in LeTID. LeTID appears to be unique to p-type Si, and is also observed in Ga-doped Si. Currently, most experimental evidence relates LeTID to the injection of hydrogen present in the dielectric surface passivation layers, such as SiN x and Al 2 O 3 , into the monocrystalline Si (c-Si) bulk during the fast-firing step. The involvement of hydrogen is further strengthened by controlled studies that show that increasing the amount of hydrogen in the dielectric during fast-firing increases the degree of LeTID. Similar to LID, a regeneration process has been discovered for LeTID. Regeneration of LeTID defects occurs when samples are exposed to 2–4 Suns illumination at elevated temperatures of 140–220 °C for 2–15 hr. Given the slower kinetics of LeTID and sample regeneration compared to LID, this poses a challenge for the manufacturing and field reliability of p-PERC cells, which will be the leading photovoltaic technologies over the next decade. Therefore, there is a need to understand LeTID and develop strategies to mitigate this effect. The defect responsible for LeTID has been extensively studied with over 100 publications, but direct spectroscopic evidence of this defect’s structure is lacking. Without an atomistic understanding of the LeTID defect, it is difficult to assess the long-term efficacy of the current industrial mitigation strategies. This, in turn, has implications on energy production for tens of gigawatts of these cells that will be deployed yearly worldwide. Using electron paramagnetic resonance, we identified a defect associated with LeTID with a g-value of 2.006, which we attribute to an Si dangling bond in an extended defect such as a vacancy agglomerate with H possibly within or in close vicinity. These vacancy agglomerates are likely created during the firing process, during which time H atoms are also injected into the bulk from the hydrogenated SiN x dielectric layer. Our atomistic-level insight shows that the LeTID defect can be mitigated by targeted intrinsic defect engineering of the c-Si material through a slower pull rate of the Cz ingot or 1000 °C oxygen ambient processing of the Si wafer to reduce the vacancy concentration. This project was a collaborative effort between the Colorado School of Mines and the National Renewable Energy Laboratory.

14 SOLAR ENERGY↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗