Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plastic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

SU-C-BRD-06: Results From a 5 Patient in Vivo Rectal Wall Dosimetry Study Using Plastic Scintillation Detectors

Purpose: To evaluate the performance characteristics of plastic scintillation detectors (PSDs) in an in vivo environment for external beam radiation, and to establish the usefulness and ease of implementation of a PSD based in vivo dosimetry system for routine clinical use. Methods: A five patient IRB approved in vivo dosimetry study was performed. Five patients with prostate cancer were enrolled and PSDs were used to monitor rectal wall dose and verify the delivered dose for approximately two fractions each week over the course of their treatment (approximately fourteen fractions), resulting in a total of 142 in vivo measurements. A set of two PSDs was fabricated for each patient. At each monitored fraction the PSDs were attached to the anterior surface of an endorectal balloon used to immobilize the patient's prostate during treatment. A CT scan was acquired with a CTon- rails linear accelerator to localize the detectors and to calculate the dose expected to be delivered to the detectors. Each PSD acquired data in 10 second intervals for the duration of the treatment. The deviation between expected and measured cumulative dose was calculated for each detector for each fraction, and averaged over each patient and the patient population as a whole. Results: The average difference between expected dose and measured dose ranged from -3.3% to 3.3% for individual patients, with standard deviations between 5.6% and 7.1% for four of the patients. The average difference for the entire population was -0.4% with a standard deviation of 2.8%. The detectors were well tolerated by the patients and the system did not interrupt the clinical workflow. Conclusion: PSDs perform well as in vivo dosimeters, exhibiting good accuracy and precision. This, combined with the practicability of using such a system, positions the PSD as a strong candidate for clinical in vivo dosimetry in the future. This work supported in part by the National Cancer Institute through an R01 grant (CA120198-01A2) and by the American Legion Auxiliary through the American Auxiliary Fellowship in Cancer Research.

60 APPLIED LIFE SCIENCES↗

Sci—Sat AM: Stereo — 07: Suitability of a plastic scintillator dosimeter for composite clinical fields delivered using the Cyberknife robotic radiosurgery system

Plastic scintillation dosimeters (PSDs) have favourable characteristics for small and composite field dosimetry in radiosurgery, however, imperfect corrections for the Cerenkov radiation contamination could limit their accuracy for complex deliveries. In this work, we characterize the dose and dose-rate linearity, directional dependence, and compare output factors with other stereotactic detectors for a new commercially available PSD (Exradin W1). We provide some preliminary comparisons of planned and measured dose for composite fields delivered clinically by a Cyberknife radiosurgery system. The W1 detector shows good linearity with dose (<0.5%) and dose rate (<0.8%) relative to the signal obtained using an ion chamber under the same conditions. A maximum difference of 2% was observed depending on the detector's angular orientation. Output factors for all detectors agree within a range of ±3.2% and ±1.5% for the 5 and 7.5 mm collimators, respectively, provided Monte-Carlo corrections for detector effects are applied to diode and ion chambers (without corrections the range is ±5.5% and ±3.1% for these two collimators). For clinical beam deliveries using 5 and 7.5 mm collimators, four of the six patients showed better agreement with planned dose for the PSD detector compared to a micro ion chamber. Two of the six patients investigated, however, showed 5% differences between PSD and planned dose, film measurements and the ratio of PSD and micro ion chamber signal suggest that further investigation is warranted for these plans. The W1 detector is a promising tool for stereotactic plan verification under the challenging dosimetric conditions of stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP1-04: Novel 3D Printed Plastic Cutouts Filled with Aluminum Oxide for Same Day Electron Radiotherapy

Purpose: Clinics that outsource electron cutout manufacturing may be unable to simulate and treat patients on the same day. To enable same day treatment, we investigate the use of 3D printed hollow cutouts filled with 30 grit Al{sub 2}O{sub 3} powder. We verified the dosimetric equivalence of such a cutout relative to an outsourced Copper cutout. Methods: Printing was performed using a Ultibots Kossel 250 V-Slot 3D printer and polylactic acid filament. Printing files were derived from an in-house 3D model designed to mate with a Varian 6 cm electron cone. Relative to conventional cutouts (Copper or Cerrobend), the height of the hollow plastic cutout was extended by 1.0 cm to increase attenuation. Measurements were performed for 6 MeV in solid water at dmax (1.4 cm) with Gafchromic™ EBT3 film; the cutout was kidney-shaped with a long and short axis of approximately 5 and 2 cm, respectively. The Copper cutout was based on an outline of the 3D printed cutout.A calibration film was exposed immediately after the electron irradiations. All films, including an un-irradiated one, were from the same batch. Films were scanned on an Epson 10000XL flatbed scanner. Film analysis was performed in DoseLab (MOBIUS Medical Systems, Houston, Tx). Results: Visual comparison of the physical cutouts revealed that the Copper cutout had a slightly smaller opening than the printed cutout. Line profiles through the registered films indicated agreement within 5% in the open section. 99.9% of pixels passed gamma analysis with 2% local percent difference, 2 mm DTA, and a 25% threshold. Conclusion: Same day simulation and treatment with electrons is feasible with 3D printing of a hollow cutout filled with Al{sub 2}O{sub 3}. Future work will include evaluations of additional cutout shapes at different depths for higher energies. Other printing materials, such as bismuth, are being tested.

60 APPLIED LIFE SCIENCES↗

Yield stress and plasticity of nanostructured titanium of different purity at 300, 77, and 4.2 K

Specimens of nanostructured titanium with different dopant concentrations were prepared by intense plastic deformation via equal-channel-angular pressing. The low-temperature mechanical characteristics of the specimens subjected to active deformation under uniaxial tension and compression were studied. The yield stress and the limit uniform deformation of nanostructured and coarse-grained polycrystalline titanium were compared.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MD simulation of plastic deformation nucleation in stressed crystallites under irradiation

The investigation of plastic deformation nucleation in metals and alloys under irradiation and mechanical loading is one of the topical issues of materials science. Specific features of nucleation and evolution of the defect system in stressed and irradiated iron, vanadium, and copper crystallites were studied by molecular dynamics simulation. Mechanical loading was performed in such a way that the modeled crystallite volume remained unchanged. The energy of the primary knock-on atom initiating a cascade of atomic displacements in a stressed crystallite was varied from 0.05 to 50 keV. It was found that atomic displacement cascades might cause global structural transformations in a region far larger than the radiation-damaged area. These changes are similar to the ones occurring in the process of mechanical loading of samples. They are implemented by twinning (in iron and vanadium) or through the formation of partial dislocation loops (in copper).

36 MATERIALS SCIENCE↗

Radiation Hardness of Scintillation Detectors Based on Organic Plastic Scintillators and Optical Fibers

Scintillation detectors (SD) based on organic plastic scintillators and optical fibers are basic detectors at all modern accelerators and in astrophysics and neutrino physics experiments. In recent years, interest in SD has significantly increased due to the upcoming major upgrade of the LHC and the construction of new accelerators NICA, FAIR, FCC, etc. At the same time, requirements on the stability and reliability of SD operation under new conditions have become stricter, and their fulfillment largely depends on radiation hardness of scintillators, optical fibers, and photodetectors. The review presents the results of the radiation hardness investigations of various scintillators, optical fibers (scintillating, as well as wavelength-shifting and clear), and optical glues used to increase light collection from scintillators by fibers. The influence of various factors (dose, dose rate, type of radiation, scintillator materials, and fluors) on light output, light collection, and transmittance of the irradiated materials and their recovery is considered. Aging of scintillators caused by environmental effects (temperature, humidity) irrespective of radiation is also briefly considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of plastic deformation on the magnetic properties and dislocation luminescence of isotopically enriched silicon {sup 29}Si:B

A correlation between the temperature dependences of the D1-line intensity of dislocation luminescence and the magnetic moment of plastically deformed isotopically enriched crystals {sup 29}Si:B is found. It is established that the magnetic susceptibility of the deformed crystals obtained by integration of the spectra of electron spin resonance and the D1-line intensity undergo similar nonmonotonic variations with temperature varying in the range of 20–32 K.

36 MATERIALS SCIENCE↗

Dynamic Model of Elastoplastic Normal Collision of Spherical Particles under Nonlocal Plasticity

The problem of normal collision of a spherical particle with a half-space is considered with allowance for nonlocal plastic deformation in the case where the strength limit depends on the contact radius, as well as for the strengthening effect in the deformed material. The dimensionless coefficient of normal velocity restitution has been calculated numerically as a function of the initial velocity of the spherical particle. The obtained data coincide well with experimental results available in the literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anomaly of Microwave Absorption of Ice near –45°C under Plastic Deformation

The microwave absorption of fresh ice subjected to plastic deformation when changing temperature from 0 to –60°C has been measured. A decrease in the losses of radiation transmission through ice at frequencies of 32 and 125 GHz with extremum at a temperature of –45°C was found. This temperature corresponds to the point at atmospheric pressure at the Widom line, which starts from a hypothetic second critical point in pressure–temperature phase space. The used measuring technique makes it possible to obtain layers of deeply supercooled water into ice and study the position of the Widom line and second critical point in phase space.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shaped silicon wafers obtained by hot plastic deformation: performance evaluation for future astronomical x-ray telescopes

In order to develop lightweight and high angular resolution x-ray mirrors, we have investigated hot plastic deformation of 4 in. silicon (111) wafers. A sample wafer was deformed using hemispherical dies with a curvature radius of 1000 mm. The measured radius of the deformed wafer was 1030 mm, suggesting that further conditioning is indispensable for better shaping. For the first time to our knowledge, x-ray reflection on a deformed wafer was detected at Al K{alpha} 1.49 keV. An estimated surface roughness of <1 nm from the x-ray reflection profile was comparable to that of a bare silicon wafer without deformation. Hence, no significant degradation of the microroughness was seen.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Localized Plasticity in the Streamlined Genomes of Vinyl Chloride Respiring Dehalococcoides

Vinyl chloride (VC) is a human carcinogen and widespread priority pollutant. Here we report the first, to our knowledge, complete genome sequences of microorganisms able to respire VC, Dehalococcoides sp. strains VS and BAV1. Notably, the respective VC reductase encoding genes, vcrAB and bvcAB, were found embedded in distinct genomic islands (GEIs) with different predicted integration sites, suggesting that these genes were acquired horizontally and independently by distinct mechanisms. A comparative analysis that included two previously sequenced Dehalococcoides genomes revealed a contextually conserved core that is interrupted by two high plasticity regions (HPRs) near the Ori. These HPRs contain the majority of GEIs and strain-specific genes identified in the four Dehalococcoides genomes, an elevated number of repeated elements including insertion sequences (IS), as well as 91 of 96 rdhAB, genes that putatively encode terminal reductases in organohalide respiration. Only three core rdhA orthologous groups were identified, and only one of these groups is supported by synteny. The low number of core rdhAB, contrasted with the high rdhAB numbers per genome (up to 36 in strain VS), as well as their colocalization with GEIs and other signatures for horizontal transfer, suggests that niche adaptation via organohalide respiration is a fundamental ecological strategy in Dehalococccoides. This adaptation has been exacted through multiple mechanisms of recombination that are mainly confined within HPRs of an otherwise remarkably stable, syntenic, streamlined genome among the smallest of any free-living microorganism.

59 BASIC BIOLOGICAL SCIENCES↗

The ion-ion correlations in organic ionic plastic crystal

Organic ionic plastic crystals (OIPCs) are emerging as promising electrolyte materials for solid-state batteries. However, despite the fast ionic diffusion, OIPCs exhibit relatively low DC conductivity in solid phases caused by strong ion-ion correlations that suppress charge transport. To understand the origin of this suppression, we performed a study of ion dynamics in the OIPC 1-Ethyl-1-methylpyrrolidinium bis (trifluoromethyl sulfonyl) imide [P 12 ][TFSI] utilizing dielectric spectroscopy, light scattering, and Nuclear Magnetic Resonance diffusometry. Comparison of the results obtained in this study with the published earlier results on an OIPC with a completely different structure (Diethyl(methyl)(isobutyl)phosphonium Hexafluorophosphate [P 1,2,2,4 ][PF 6 ]) revealed strong similarities in ion dynamics in both systems. Unlike DC conductivity, which may drop more than ten times between melted and solid phases, diffusion of anions and cations remains high and does not show strong changes at phase transition. The conductivity spectra in the broad frequency range demonstrate unusual shapes in solid phases with an additional step separating fast local ion motions from suppressed long-range charge diffusion controlling DC conductivity. We suggested that in solid phases, anions and cations can jump only between the specific ion sites defined by the crystalline structure. These constraints lead to strong cation-cation and anion-anion correlations strongly suppressing long-range charge transport.

36 MATERIALS SCIENCE↗

Development of High Speed Multispectral Imaging for Sorting Automotive Plastics, Phase II Final Report

The objective of this Small Business Innovation Research Phase II project is to develop an infrared (IR) hyperspectral imaging system suitable for recycling end-of-life automotive plastics due to rapid, concurrent identification of multiple samples according to their polymer types. This Phase II research has contributed greatly to the development of a prototype sorting unit. Techniques developed from this technology are already in use in multiple installations worldwide. RT investigated various approaches to identification and sorting of the polymers. Some approaches were determined to be unsuitable for the current application. Multiple approaches were determined to be suitable, however a hyperspectral imaging system utilizing a single high speed camera with full spectral capability looking over the entire waste stream width has been selected.

47 OTHER INSTRUMENTATION↗

Comprehensive Report For Proposed Elevated Temperature Elastic Perfectly Plastic (EPP) Code Cases Representative Example Problems

Background: The current rules in the nuclear section of the ASME Boiler and Pressure Vessel (B&PV) Code , Section III, Subsection NH for the evaluation of strain limits and creep-fatigue damage using simplified methods based on elastic analysis have been deemed inappropriate for Alloy 617 at temperatures above 1200F (650C)1. To address this issue, proposed code rules have been developed which are based on the use of elastic-perfectly plastic (E-PP) analysis methods and which are expected to be applicable to very high temperatures. The proposed rules for strain limits and creep-fatigue evaluation were initially documented in the technical literature 2, 3, and have been recently revised to incorporate comments and simplify their application. The revised code cases have been developed. Task Objectives: The goal of the Sample Problem task is to exercise these code cases through example problems to demonstrate their feasibility and, also, to identify potential corrections and improvements should problems be encountered. This will provide input to the development of technical background documents for consideration by the applicable B&PV committees considering these code cases for approval. This task has been performed by Hollinger and Pease of Becht Engineering Co., Inc., Nuclear Services Division and a report detailing the results of the E-PP analyses conducted on example problems per the procedures of the E-PP strain limits and creep-fatigue draft code cases is enclosed as Enclosure 1. Conclusions: The feasibility of the application of the E-PP code cases has been demonstrated through example problems that consist of realistic geometry (a nozzle attached to a semi-hemispheric shell with a circumferential weld) and load (pressure; pipe reaction load applied at the end of the nozzle, including axial and shear forces, bending and torsional moments; through-wall transient temperature gradient) and design and operating conditions (Levels A, B and C).

36 MATERIALS SCIENCE↗

Quantifying Damage Accumulation During Ductile Plastic Deformation Using Synchrotron Radiation

Under this grant, we have developed and demonstrated the ability of near-field High Energy Diffraction Microscopy (nf-HEDM) to map crystal orientation fields over three dimensions in deformed polycrystalline materials. Experimental work was performed at the Advanced Photon Source (APS) at beamline 1-ID. Applications of this new capability to ductile deformation of copper and zirconium samples were demonstrated as was the comparison of the experimental observations to computational plasticity models using a fast Fourier transform based algorithm that is able to handle the large experimental data sets. No such spatially resolved, direct comparison between measured and computed microstructure evolutions had previously been possible. The impact of this work is reflected in numerous publications and presentations as well as in the investments by DOE and DOD laboratories of millions of dollars in applying the technique, developing sophisticated new hardware that allows the technique to be applied to a wide variety of materials and materials problems, and in the use of the technique by other researchers. In essence, the grant facilitated the development of a new form of three dimensional microscopy and its application to technologically critical states of polycrystalline materials that are used throughout the U.S. and world economies. On-going collaborative work is further optimizing experimental and computational facilities at the APS and is pursuing expanded facilities.

36 MATERIALS SCIENCE↗

A High-Rate, Single-Crystal Model including Phase Transformations, Plastic Slip, and Twinning

An anisotropic, rate-­dependent, single-­crystal approach for modeling materials under the conditions of high strain rates and pressures is provided. The model includes the effects of large deformations, nonlinear elasticity, phase transformations, and plastic slip and twinning. It is envisioned that the model may be used to examine these coupled effects on the local deformation of materials that are subjected to ballistic impact or explosive loading. The model is formulated using a multiplicative decomposition of the deformation gradient. A plate impact experiment on a multi-­crystal sample of titanium was conducted. The particle velocities at the back surface of three crystal orientations relative to the direction of impact were measured. Molecular dynamics simulations were conducted to investigate the details of the high-­rate deformation and pursue issues related to the phase transformation for titanium. Simulations using the single crystal model were conducted and compared to the high-­rate experimental data for the impact loaded single crystals. The model was found to capture the features of the experiments.

36 MATERIALS SCIENCE↗

The Effect of Process History on Grain Boundaries and Dislocation Substructures on Functional Properties of Nb for SRF Cavities: Plastic Formability and Microstructural Evolution. Final report

While much progress has been made in improving the performance of cavities in the past decade, reproducible performance remains elusive. This renewal of “The cost of grain boundaries on the performance of superconducting cavities” examines in further depth the interactions between forming and annealing processes and functional performance at the scale of dislocation substructure and grain boundaries. There are five tasks identified in the renewal, which are: Characterization / analysis of current cavity technology: Effect of deformation, heat treatment, surface treatments, and residual damage on cavity function (Lee and Bieler) Characterization of dislocation mechanisms in single and bicrystals (Bieler) Quantifying effects of impurities and deformation mechanisms in Nb using density functional theory calculations (Solanki) Crystal plasticity constitutive model development (Pourboghrat and Eisenlohr) Modeling and measuring thermal conductivity in thin layers (Wright)

36 MATERIALS SCIENCE↗