Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

A study of the Io-associated plasma and neutral sodium cloud

Narrow-band interference filter images were obtained for the Io torus at the S II wavelengths of 6716, 6731 and at the wavelenght of the S III, 9532 spectrum. The purpose of these observations is to study the short term temporal behavior of the torus and to gain a better understanding of the systematic morphology of the torus. From these images, estimates were obtained for the electron and ion densities and ion temperatures as a function of longitude, latitude, radius from Jupiter, and time. From the analysis of images taken in 1983 and 1984, extremely sharp longitudinal variations in plasma density were detected, subcorotational velocities were measures in the torus plasma, the presence of an optical east-west brightness asymmetry was confirmed in the ion emissions, and longitudinal variations were detected in torus ion temperatures.

Pilcher, Carl B.↗

Optimizing Lunar Map Partitioning for Multipath Fade Loss Analyses

A methodology is presented pertaining to the run-time optimization of quasi-optical ray-tracing simulations. These shooting-and-bouncing ray methods are used for assessing multipath fade loss in cislunar communication links. Our approach employs partitioning lunar terrain maps in shapes that approximate two-dimensional projections of Fresnel zone cross-sections. This technique drastically reduces computational run-time without causing significant loss of simulation accuracy.

Digital elevation models↗

Effect of a Silicone Contaminant Film on the Transmittance Properties of AR-coated Fused Silica

We present the results of a laboratory test to determine the effects of bulk deposited, DC-704 silicone contaminant film on the transmittance properties of an anti-reflective (AR) coated fused silica optical substrate. Testing and optical measurements were performed in vacuum in the Boeing Combined Effects Test Facility (CETF). The test and measurement procedures are described herein. Measurement results are presented showing the change in transmittance characteristics as a function of contaminant deposit thickness and vacuum ultra-violet (vuv) exposure levels. Measurement results show an initial degradation in the transmittance of the contaminated sample. This is followed by a partial recovery in sample transmittance as the sample is exposed to additional VUV radiation. Transmittance results also show a loss of transmission in the ultraviolet portion of the spectrum and an increase in transmission in the infrared portion of the spectrum. These transmittance results are characteristic of thin-film interference effects. Thin-film analyses indicate that some of the observed transmittance results can be successfully modeled, but only if the contaminant film is assumed to be SiO2 rather than DC-704 silicone. Post-test Scanning Electron Microscope (SEM) scans of the test sample indicate the formation of contaminant islands and the presence of a thin uniform coating of contaminant deposit on the sample

Boeder, Paul A.↗

Continuous monitoring of prostate position using stereoscopic and monoscopic kV image guidance

Purpose: To demonstrate continuous kV x-ray monitoring of prostate motion using both stereoscopic and monoscopic localizations, assess the spatial accuracy of these techniques, and evaluate the dose delivered from the added image guidance. Methods: The authors implemented both stereoscopic and monoscopic fiducial localizations using a room-mounted dual oblique x-ray system. Recently developed monoscopic 3D position estimation techniques potentially overcome the issue of treatment head interference with stereoscopic imaging at certain gantry angles. To demonstrate continuous position monitoring, a gold fiducial marker was placed in an anthropomorphic phantom and placed on the Linac couch. The couch was used as a programmable translation stage. The couch was programmed with a series of patient prostate motion trajectories exemplifying five distinct categories: stable prostate, slow drift, persistent excursion, transient excursion, and high frequency excursions. The phantom and fiducial were imaged using 140 kVp, 0.63 mAs per image at 1 Hz for a 60 s monitoring period. Both stereoscopic and monoscopic 3D localization accuracies were assessed by comparison to the ground-truth obtained from the Linac log file. Imaging dose was also assessed, using optically stimulated luminescence dosimeter inserts in the phantom. Results: Stereoscopic localization accuracy varied between 0.13 ± 0.05 and 0.33 ± 0.30 mm, depending on the motion trajectory. Monoscopic localization accuracy varied from 0.2 ± 0.1 to 1.1 ± 0.7 mm. The largest localization errors were typically observed in the left–right direction. There were significant differences in accuracy between the two monoscopic views, but which view was better varied from trajectory to trajectory. The imaging dose was measured to be between 2 and 15 μGy/mAs, depending on location in the phantom. Conclusions: The authors have demonstrated the first use of monoscopic localization for a room-mounted dual x-ray system. Three-dimensional position estimation from monoscopic imaging permits continuous, uninterrupted intrafraction motion monitoring even in the presence of gantry rotation, which may block kV sources or imagers. This potentially allows for more accurate treatment delivery, by ensuring that the prostate does not deviate substantially from the initial setup position.

60 APPLIED LIFE SCIENCES↗

Single Molecule and Nanoparticle Imaging in Biophysical, Surface, and Photocatalysis Studies

A differential interference contrast (DIC) polarization anisotropy is reported that was successfully used for rotational tracking of gold nanorods attached onto a kinesin-driven microtubule. A dual-wavelength detection of single gold nanorods rotating on a live cell membrane is described. Both transverse and longitudinal surface plasmon resonance (SPR) modes were used for tracking the rotational motions during a fast dynamic process under a DIC microscope. A novel method is presented to determine the full three-dimensional (3D) orientation of single plasmonic gold nanorods rotating on live cell membranes by combining DIC polarization anisotropy with an image pattern recognition technique. Polarization- and wavelength-sensitive DIC microscopy imaging of 2- m long gold nanowires as optical probes in biological studies is reported. A new method is demonstrated to track 3D orientation of single gold nanorods supported on a gold film without angular degeneracy. The idea is to use the interaction (or coupling) of gold nanorods with gold film, yielding characteristic scattering patterns such as a doughnut shape. Imaging of photocatalytic activity, polarity and selectivity on single Au-CdS hybrid nanocatalysts using a high-resolution superlocalization fluorescence imaging technique is described.

36 MATERIALS SCIENCE↗

Light scattering by ultracold atoms in an optical lattice

We investigate theoretically light scattering of photons by ultracold atoms in an optical lattice in the linear regime. A full quantum theory for the atom-photon interactions is developed as a function of the atomic state in the lattice along the Mott-insulator-superfluid phase transition, and the photonic-scattering cross section is evaluated as a function of the energy and of the direction of emission. The predictions of this theory are compared with the theoretical results of a recent work on Bragg scattering in time-of-flight measurements [A.M. Rey et al., Phys. Rev. A 72, 023407 (2005)]. We show that, when performing Bragg spectroscopy with light scattering, the photon recoil gives rise to an additional atomic site-to-site hopping, which can interfere with ordinary tunneling of matter waves and can significantly affect the photonic-scattering cross section.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Drift in interference filters. II - Radiation effects

Studies of peak transmission drift in narrow-band interference filters have shown that there exist two mechanisms that cause drift toward shorter wavelengths. One is dependent on the thermal history of the filter and is discussed in Part 1 of this paper. The other is dependent on the exposure of the filter to radiation. For ZnS-cryolite filters of particular design, it is experimentally demonstrated that the filters are most sensitive to radiation in a 100-A band centered at approximately 3900 A. The drift rate in the focal plane of an f/20 solar image is approximately 3 A/100 hr of exposure. Further, it is also shown by model calculations that the observed radiation-induced drift is consistent with the hypothesis that the optical thickness of ZnS decreases in proportion to the radiant energy absorbed.

Title, A. M.↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space

Measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution are needed to quantify processes that regulate CO2 storage by the land and oceans. The Orbiting Carbon Observatory (OCO) is the first space mission focused on atmospheric CO2 for measuring total column CO, and O2 by detecting the spectral absorption in reflected sunlight. The OCO mission is an essential step, and will yield important new information about atmospheric CO2 distributions. However there are unavoidable limitations imposed by its measurement approach. These include best accuracy only during daytime at moderate to high sun angles, interference by cloud and aerosol scattering, and limited signal from CO2 variability in the lower tropospheric CO2 column. We have been developing a new laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our initial goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to develop a space instrument and mission approach for active measurements of the CO2 mixing ratio at the 1-2 ppmv level. Our technique is much less sensitive to cloud and atmospheric scattering conditions and would allow continuous measurements of CO2 mixing ratio in the lower troposphere from orbit over land and ocean surfaces during day and night. Our approach is to use the 1570nm CO2 band and a 3-channel laser absorption spectrometer (i.e. lidar used an altimeter mode), which continuously measures at nadir from a near polar circular orbit. The approach directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses several tunable fiber laser transmitters which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band. This band is free from interference from other gases and has temperature insensitive absorption lines. During the measurement the lasers are tuned on- and off- a selected CO2 line near 1572 nm and a selected O2 line near 768 nm in the Oxygen A band at kHz rates. The lasers use tunable diode seed lasers followed by fiber amplifiers, and have spectral widths much narrower than the gas absorption lines. The receiver uses a 1-m diameter telescope and photon counting detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and offline surface echo via the differential optical absorption technique. Our technique rapidly alternates between several on-line wavelengths set to the sides of the selected gas absorption lines. It exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. This maximizes sensitivity to CO2 in the boundary layer, where variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column will use an identical approach with an O2 line. Thee laser frequencies are tunable and have narrow (MHz) line widths. In combination with sensitive photon counting detectors these enables much higher spectral resolution and precision than is possible with passive spectrometer. 1aser backscatter profiles are also measured, which permits identifying measurements made to cloud tops and through aerosol layers. The measurement approach using lasers in common-nadir-zenith path allows retrieving CO2 column mixing ratios in the lower troposphere irrespective of sun angle. Pulsed laser signals, time gated receiver and a narrow receiver field-of-view are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. Nonetheless, the optical absorption change due to a change of a few ppO2 is small, <1 % which makes achieving the needed measurement sensitivities and stabilities quite challenging. Measurement SNRs and stabilities of >600:1 are needed to estimate CO2 mixing ratio at the 1-2 ppm level. We have calculated characteristics of the technique and have demonstrated aspects of the laser, detector and receiver approaches in th e laboratory We have also measured O2 in an absorption cell, and made C02 measurements over a 400 m long (one way) horizontal path using a sensor breadboard. We will describe these and more details of our approach in the paper.

Abshire, James B.↗

Entanglement of excitons by acoustic guiding

A system is described that exhibits the functionality of a beam-splitter, typically an optical device that splits a beam of light in two. In this case, the beams are acoustic pulses and can lead to the creation of a Wannier-Mott exciton: a bound state of an electron and an electron hole whose attraction to each other is maintained by the electrostatic Coulomb force. This exciton beam-splitter is lossy (i.e., involves the dissipation of electrical or electromagnetic energy). Half of the time the exciton is radiated away. Nevertheless, if the exciton is not lost, the exciton is now in a superposition of two states that can be well separated in position. Four such beam-splitters can be used to make an exciton interferometer that uses the interference patterns from the interacting acoustic pulses to extract information.

Yurke, Bernard↗

Revisiting an airgap split-optics mitigation for beam filamentation in high power lasers

We extend the split-optic approach for mitigating filamentation in a thick optical component previously proposed for small beams to conditions relevant to high-power lasers. The split-optic approach divides a thick optic into two thinner optics separated by an airgap to reduce filamentation through diffraction management. Our numerical study focuses on filamentation of a flat-top beam with intensity modulation noise sources passing through a split-optic system. The improvement in the distance to collapse in glass is shown to be potentially substantial (>30%), yet has limited increase with the airgap size, unlike the common understanding when considering a collapse of a whole beam or a sole perturbation on a beam. The improvement in the collapse distance in glass asymptotes to an upper bound value that depends mainly on the beam mean intensity and its contrast for any airgap size above some value that depends mainly on the shortest spatial periods comprising the excitation noise source. Examining the difference in the simulation results for a periodic versus a randomly generated perturbation source-term suggests that the observed effect is governed by the statistical interference dynamics of the beam while propagating through the airgap

47 OTHER INSTRUMENTATION↗

Quantification of phosphorus in single cells using synchrotron X-ray fluorescence

Phosphorus is required for numerous cellular compounds and as a result can serve as a useful proxy for total cell biomass in studies of cell elemental composition. Single-cell analysis by synchrotron X-ray fluorescence (SXRF) enables quantitative and qualitative analyses of cell elemental composition with high elemental sensitivity. Element standards are required to convert measured X-ray fluorescence intensities into element concentrations, but few appropriate standards are available, particularly for the biologically important element P. Empirical P conversion factors derived from other elements contained in certified thin-film standards were used to quantify P in the model diatom Thalassiosira pseudonana, and the measured cell quotas were compared with those measured in bulk by spectrophotometry. The mean cellular P quotas quantified with SXRF for cells on Au, Ni and nylon grids using this approach were not significantly different from each other or from those measured spectrophotometrically. Inter-cell variability typical of cell populations was observed. Additionally, the grid substrates were compared for their suitability to P quantification based on the potential for spectral interferences with P. Nylon grids were found to have the lowest background concentrations and limits of detection for P, while background concentrations in Ni and Au grids were 1.8- and 6.3-fold higher. The advantages and disadvantages of each grid type for elemental analysis of individual phytoplankton cells are discussed.

54 ENVIRONMENTAL SCIENCES↗

Electron interference in atomic ionization by two crossing polarized ultrashort pulses

Formation of geometrically regular interference patterns in the photoelectron momentum distributions (PMDs) corresponding to the photoionization of atoms by two single-color, crossing ultrashort pulses is investigated both analytically and numerically. It is shown that, in contrast to the photoionization by monochromatic pulses, PMDs for the ionization by crossing and co-propagating broadband pulses are essentially different (unless both pulses are linearly polarized), namely, when one pulse is linearly polarized along the propagation direction, ˆk, of the circularly polarized (CP) pulse, then interference maxima (minima) of the ionization probability have the form of three-dimensional single-arm regular spirals which are wound along ˆk. Next, the interference maxima (minima) of the ionization probability by a pair of crossing elliptically polarized pulses have the form of either Newton's rings or two-arm Fermat's spirals, depending on the position of a detection plane. Remarkably, these regular patterns occur only for certain values of the pulse ellipticities, and they become distorted for CP pulses. For both above-mentioned pulse configurations, the features of interference patterns depend on the time delay between pulses, their relative electric field amplitude, and relative carrier-envelope phase. Our predictions, illustrated by the numerical results for the ionization of H and He atoms by two orthogonal pulses, are quite general and we expect them to be valid for the ionization of any randomly oriented atomic or molecular target.

74 ATOMIC AND MOLECULAR PHYSICS↗

Modeling of transient interference phenomena in colinear laser spectroscopy

Colinear laser spectroscopy of fast atomic beams has been established as one of the main tools to perform precision experiments with atoms containing short-lived nuclei. Although highly sensitive, the spectral resolution of these techniques is typically limited to several MHz. Here, we study the use of transient interference phenomena to potentially improve the experimental resolution. Previous attempts to implement Ramsey-type measurements with fast beams were limited by the lack of understanding of the observed line shapes. Additionally, by using a simple model, we provide a satisfactory description of the previously observed line shapes and propose alternative experimental schemes to improve the resolution in fast ion-beam experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Raman Gas Species Measurements in Hydrocarbon-Fueled Rocket Engine Injector Flows

Propellent injector development at MSFC (Marshall Space Flight Center) includes experimental analysis using optical techniques, such as Raman, fluorescence, or Mie scattering. For the application of spontaneous Raman scattering to hydrocarbon-fueled flows a technique needs to be developed to remove the interfering polycyclic aromatic hydrocarbon fluorescence from the relatively weak Raman signals. A current application of such a technique is to the analysis of the mixing and combustion performance of multijet, impinging-jet candidate fuel injectors for the baseline Mars ascent engine, which will burn methane and liquid oxygen produced in-situ on Mars to reduce the propellent mass transported to Mars for future manned Mars missions. The present technique takes advantage of the strongly polarized nature of Raman scattering. It is shown to be discernable from unpolarized fluorescence interference by subtracting one polarized image from another. Both of these polarized images are obtained from a single laser pulse by using a polarization-separating calcite rhomb mounted in the imaging spectrograph. A demonstration in a propane-air flame is presented.

Wehrmeyer, Joseph A.↗

Raman Gas Species Measurements in Hydrocarbon-Fueled Rocket Engine Injector Flows

Rocket engine propellent injector development at NASA-Marshall includes experimental analysis using optical techniques, such as Raman, fluorescence, or Mie scattering. For the application of spontaneous Raman scattering to hydrocarbon-fueled flows a technique needs to be developed to remove the interfering polycyclic aromatic hydrocarbon fluorescence from the relatively weak Raman signals. A current application of such a technique is to the analysis of the mixing and combustion performance of multijet, impinging-jet candidate fuel injectors for the baseline Mars ascent engine, which will burn methane and liquid oxygen produced in-situ on Mars to reduce the propellent mass transported to Mars for future manned Mars missions. The Raman technique takes advantage of the strongly polarized nature of Raman scattering. It is shown to be discernable from unpolarized fluorescence interference by subtracting one polarized image from another. Both of these polarized images are obtained from a single laser pulse by using a polarization-separating calcite rhomb mounted in the imaging spectrograph. A demonstration in a propane-air flame is presented, as well as a high pressure demonstration in the NASA-Marshall Modular Combustion Test Artice, using the liquid methane-liquid oxygen propellant system

Wehrmeyer, Joseph↗

Raman Spectroscopy for Instantaneous Multipoint, Multispecies Gas Concentration and Temperature Measurements in Rocket Engine Propellant Injector Flows

Propellent injector development at MSFC includes experimental analysis using optical techniques, such as Raman, fluorescence, or Mie scattering. For the application of spontaneous Raman scattering to hydrocarbon-fueled flows a technique needs to be developed to remove the interfering polycyclic aromatic hydrocarbon fluorescence from the relatively weak Raman signals. A current application of such a technique is to the analysis of the mixing and combustion performance of multijet, impinging-jet candidate fuel injectors for the baseline Mars ascent engine, which will bum methane and liquid oxygen produced in-situ on Mars to reduce the propellent mass transported to Mars for future manned Mars missions. The present technique takes advantage of the strongly polarized nature of Raman scattering. It is shown to be discernable from unpolarized fluorescence interference by subtracting one polarized image from another. Both of these polarized images are obtained from a single laser pulse by using a polarization-separating calcite rhomb mounted in the imaging spectrograph. A demonstration in a propane-air flame is presented.

Wehrmeyer, Joseph A.↗

Raman Spectroscopy for Instantaneous Multipoint, Multispecies Gas Concentration and Temperature Measurements in Rocket Engine Propellant Injector Flows

Propellant injector development at MSFC includes experimental analysis using optical techniques, such as Raman, fluorescence, or Mie scattering. For the application of spontaneous Raman scattering to hydrocarbon-fueled flows a technique needs to be developed to remove the interfering polycyclic aromatic hydrocarbon fluorescence from the relatively weak Raman signals. A current application of such a technique is to the analysis of the mixing and combustion performance of multijet, impinging-jet candidate fuel injectors for the baseline Mars ascent engine, which will burn methane and liquid oxygen produced in-situ on Mars to reduce the propellant mass transported to Mars for future manned Mars missions. The present technique takes advantage of the strongly polarized nature of Raman scattering. It is shown to be discernable from unpolarized fluorescence interference by subtracting one polarized image from another. Both of these polarized images are obtained from a single laser pulse by using a polarization-separating calcite rhomb mounted in the imaging spectrograph. A demonstration in a propane-air flame is presented.

Wehrmeyer, Joseph A.↗

Polarimetric observations of Comet Kohoutek (1973f)

Radio, optical, and visual observations were made of Comet Kohoutek (1973f) using facilities of the National Radio Astronomy Observatory (NRAO) and of the Hawaii Night Sky Observatory, State University of New York at Albany (SUNYA). Transit observations were made using the NRAO 300 ft radio telescope on six consecutive days beginning November 24, 1973. Observations were carried out in the continuum at 11 cm using the 4-feed system at different position angles. The data were recorded on magnetic tape and were computer reduced. Results were negative, with an rms error of 62 milli flux units, giving an upper limit of 180 mfu for the 11 cm continuum emission from the Comet. This relatively high detection limit resulted from a combination of interference and bad weather that affected these pre-perihelion observations. No observations could be scheduled near or after perihelion.

Weinberg, J. L.↗