Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Estimations of ABL fluxes and other turbulence parameters from Doppler lidar data

Techniques for extraction boundary layer parameters from measurements of a short-pulse CO2 Doppler lidar are described. The measurements are those collected during the First International Satellites Land Surface Climatology Project (ISLSCP) Field Experiment (FIFE). By continuously operating the lidar for about an hour, stable statistics of the radial velocities can be extracted. Assuming that the turbulence is horizontally homogeneous, the mean wind, its standard deviations, and the momentum fluxes were estimated. Spectral analysis of the radial velocities is also performed from which, by examining the amplitude of the power spectrum at the inertial range, the kinetic energy dissipation was deduced. Finally, using the statistical form of the Navier-Stokes equations, the surface heat flux is derived as the residual balance between the vertical gradient of the third moment of the vertical velocity and the kinetic energy dissipation. Combining many measurements would normally reduce the error provided that, it is unbiased and uncorrelated. The nature of some of the algorithms however, is such that, biased and correlated errors may be generated even though the raw measurements are not. Data processing procedures were developed that eliminate bias and minimize error correlation. Once bias and error correlations are accounted for, the large sample size is shown to reduce the errors substantially. The principal features of the derived turbulence statistics for two case studied are presented.

Gal-Chen, Tzvi↗

Analysis of the inter-species power balance in JET plasmas

Most auxiliary heating methods provide heating to more than one particle species (electrons, ions, impurities) in a fusion plasma. This can lead to substantial temperature differences between species, depending on conditions such as heating power to the different species and collisionality, with temperature differences between species limited by inter-species thermal equipartition and transport. The analysis of the steady-state electron-ion and impurity-ion power balances presented in this paper are used for consistency-checking experimental ion and electron temperature measurements and for inferring the main ion temperature from measured impurity temperatures. As ion temperature measurements by charge exchange spectroscopy (CXS) based on impurity ions have become more difficult and time-consuming since the installation of the ITER-like wall (ILW) with Be and W PFC's, knowing the maximum sustainable temperature difference between ions and electrons, |T i -T e | allows rejecting erroneous measurements. It also obviates the need for an ion temperature measurement, if an electron temperature measurement is available and |T i - T e | cannot be larger than the combined errors of the underlying measurements. A power balance analysis is also required for estimating the errors of the ion and electron heat fluxes prior to any species-resolved transport analysis. The ion-impurity temperature differences are usually found to be small due to strong thermal equipartition between ion species. However, they can approach 10% in JET-ILW low density, high power discharges, such the ones under development for a future JET deuterium–tritium campaign (Joffrin et al 2019 Nucl. Fusion). This has a generally small, but not always negligible effect on the calculation of fusion reaction rates, which depend on main ion temperatures. An important outcome of this analysis is that temperature differences between impurity species are always much smaller than between the impurities and hydrogenic species and can usually be neglected. The article presents two methods for calculating the impurity-to-main ion temperature ratio. Finally, this analysis leads to a method for the reconstruction ion temperature profiles from ion temperature data available at only one or a small number of spatial locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photo-sputtering of ice and hydrogen around Saturn's rings

It is noted that rocketborne UV spectroscopic measurements have shown that a dense cloud on atomic hydrogen surrounds Saturn which has been interpreted as being associated with the Saturn ring system. Several ring sources of atomic hydrogen have been proposed, but abundance and lifetime estimates require a source which is much more potent than those previously considered. An alternate mechanism is proposed which satisfies this source requirement and involves photodissociation of surface water molecules on the icy ring material. The source rate for this mechanism is within a factor of two of the required value and is within the experimental error of the measurement.

Carlson, R. W.↗

Impact of point spread function higher moments error on weak gravitational lensing – II. A comprehensive study

ABSTRACT Weak lensing is one of the most powerful probes for dark matter and dark energy science, although it faces increasing challenges in controlling systematic uncertainties as the statistical errors become smaller. The point spread function (PSF) needs to be precisely modeled to avoid systematic error on the weak lensing measurements. The weak lensing biases induced by errors in the PSF model second moments, i.e. its size and shape, are well-studied. However, Zhang et al. showed that errors in the higher moments of the PSF may also be a significant source of systematics for upcoming weak lensing surveys. Therefore, this work comprehensively investigate the modelling quality of PSF moments from the 3rd to 6th order, and propagate the PSFEx higher moments modelling error in the HSC survey data set to the weak lensing shear–shear correlation functions and their cosmological analyses. The overall multiplicative shear bias associated with errors in PSF higher moments can cause an ∼0.1σ shift on the cosmological parameters for LSST Y10, while the associated additive biases can induce 1σ uncertainties in cosmology parameter inference for LSST Y10, if not accounted. We compare the PSFEx model with PSF in Full FOV, and find similar performance in modelling the PSF higher moments. We conclude that PSF higher moment errors of the future PSF models should be reduced from those in current methods, otherwise needed to be explicitly modeled in the weak lensing analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Study of advanced system for position location and navigation

Concepts are investigated for improving location precision and system capacity relative to current satellite based data collection and location systems. The TRILOC concept provides either or both improvements in location and system capacity by utilizing three measurements acquired during a single transmission from a platform for location purposes. The location algorithm is developed, and range differences are measured onboard the satellite. An error analysis then relates platform location errors to the precision with which the measurements are made. The second concept is to increase system capacity by means of directive antennas onboard the satellite for reducing interference and/or reducing platform power. The potential advantages and disadvantages of both sweeping and fixed directive antennas for random access systems are evaluated.

Source record↗

A feasibility study of hand kinematics for EVA analysis using magnetic resonance imaging

A new method of analyzing the kinematics of joint motion is developed. Magnetic Resonance Imaging (MRI) offers several distinct advantages. Past methods of studying anatomic joint motion have usually centered on four approaches. These methods are x-ray projection, goniometric linkage analysis, sonic digitization, and landmark measurement of photogrammetry. Of these four, only x-ray is applicable for in vivo studies. The remaining three methods utilize other types of projections of inter-joint measurements, which can cause various types of error. MRI offers accuracy in measurement due to its tomographic nature (as opposed to projection) without the problems associated with x-ray dosage. Once the data acquisition of MR images was complete, the images were processed using a 3D volume rendering workstation. The metacarpalphalangeal (MCP) joint of the left index finger was selected and reconstructed into a three-dimensional graphic display. From the reconstructed volumetric images, measurements of the angles of movement of the applicable bones were obtained and processed by analyzing the screw motion of the MCP joint. Landmark positions were chosen at distinctive locations of the joint at fixed image threshold intensity levels to ensure repeatability. The primarily two dimensional planar motion of this joint was then studied using a method of constructing coordinate systems using three (or more) points. A transformation matrix based on a world coordinate system described the location and orientation of a local target coordinate system. Future research involving volume rendering of MRI data focusing on the internal kinematics of the hand's individual ligaments, cartilage, tendons, etc. will follow. Its findings will show the applicability of MRI to joint kinematics for gaining further knowledge of the hand-glove (power assisted) design for extravehicular activity (EVA).

Dickenson, Rueben D.↗

Visibility of DCT Quantization Error: Effects of Display Resolution

As part of a program of research to understand the visibility of DCT quantization errors and thereby design optimal quantizers, we measured visibility of DCT quantization error as a function of display resolution in pixels/degree. Visibilities are consistent with a model incorporating effects of block size and spatial pooling.

Watson, Andrew B.↗

Detailed Uncertainty Analysis of the ZEM-3 Measurement System

The measurement of Seebeck coefficient and electrical resistivity are critical to the investigation of all thermoelectric systems. Therefore, it stands that the measurement uncertainty must be well understood to report ZT values which are accurate and trustworthy. A detailed uncertainty analysis of the ZEM-3 measurement system has been performed. The uncertainty analysis calculates error in the electrical resistivity measurement as a result of sample geometry tolerance, probe geometry tolerance, statistical error, and multi-meter uncertainty. The uncertainty on Seebeck coefficient includes probe wire correction factors, statistical error, multi-meter uncertainty, and most importantly the cold-finger effect. The cold-finger effect plagues all potentiometric (four-probe) Seebeck measurement systems, as heat parasitically transfers through thermocouple probes. The effect leads to an asymmetric over-estimation of the Seebeck coefficient. A thermal finite element analysis allows for quantification of the phenomenon, and provides an estimate on the uncertainty of the Seebeck coefficient. The thermoelectric power factor has been found to have an uncertainty of +9-14 at high temperature and 9 near room temperature.

Seebeck effect↗

Optimizing Geant4 Hadronic Models

Geant4, the leading detector simulation toolkit used in high energy physics, employs a set of physics models to simulate interactions of particles with matter across a wide range of energies. These models, especially the hadronic ones, rely largely on directly measured cross-sections and inclusive characteristics, and use physically motivated parameters. However, they generally aim to cover a broad range of possible simulation tasks and may not always be optimized for a particular process or a given material. The Geant4 collaboration recently made many parameters of the models accessible via a configuration interface. This opens a possibility to fit simulated distributions to the thin target experimental datasets and extract optimal values of the model parameters and the associated uncertainties. Such efforts are currently undertaken by the Geant4 collaboration with the goal of offering alternative sets of model parameters, also known as "tunes", for certain applications. The effort should subsequently lead to more accurate estimates of the systematic errors in physics measurements given the detector simulation role in performing the physics measurements. Results of the study are presented to illustrate how Geant4 model parameters can be optimized through applying fitting techniques, to improve the agreement between the Geant4 and the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptor for Measuring Principal Strains with Tuckerman Strain Gage

An adapter is described which uses three Tuckerman optical strain gages to measure the displacement of the three vortices of an equilateral triangle along lines 120 degrees apart. These displacements are substituted in well-known equations in order to compute the magnitude and direction of the principal strains. Tests of the adaptor indicate that principal strains over a gage length of 1.42 inch may be measured with a systematic error not exceeding 4 percent and a mean observational error of the order of + or minus 0.000006. The maximum observed error in strain was of the order of 0.00006. The directions of principal strains for unidirectional stress were measured with the adaptor with an average error of the order of 1 degree.

INSTRUMENTS-STRAIN GAUGES-RUGE & DE FOREST↗

Inorganic Chlorine Partitioning in the Summer Lower Stratosphere: Modeled and Measured [ClONO2/HCl] During POLARIS

We examine inorganic chlorine (Cly) partitioning in the summer lower stratosphere using in situ ER-2 aircraft observations made during the Photochemistry of Ozone Loss in the Arctic Region in Summer (POLARIS) campaign. New steady state and numerical models estimate [ClONO2]/[HCl] using currently accepted photochemistry. These models are tightly constrained by observations with OH (parameterized as a function of solar zenith angle) substituting for modeled HO2 chemistry. We find that inorganic chlorine photochemistry alone overestimates observed [ClONO2]/[HCl] by approximately 55-60% at mid and high latitudes. On the basis of POLARIS studies of the inorganic chlorine budget, [ClO]/[ClONO2], and an intercomparison with balloon observations, the most direct explanation for the model-measurement discrepancy in Cly partitioning is an error in the reactions, rate constants, and measured species concentrations linking HCl and ClO (simulated [ClO]/[HCl] too high) in combination with a possible systematic error in the ER-2 ClONO2 measurement (too low). The high precision of our simulation (+/-15% 1-sigma for [ClONO2]/[HCl], which is compared with observations) increases confidence in the observations, photolysis calculations, and laboratory rate constants. These results, along with other findings, should lead to improvements in both the accuracy and precision of stratospheric photochemical models.

Voss, P. B.↗

Status of HEU-Pb in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook

The Department of Energy invests tens of millions of dollars each year to develop the next generation of nuclear engineering modeling & simulation (M&S) tools. These tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers become more powerful, we are able to enhance resolution in our calculations. This improved resolution is taking us to a point where the limitations of simulation capability are in the quality of data, including our ability to quantify the uncertainty and sensitivity of the data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. Thus, M&S tools need evaluated and quality-assured experimental data for validation purposes. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross-section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. Figure 1 organizes all the benchmark evaluations that have been performed by the isotope of interest, in this case Pb, and the average neutron energy the system. Compared to other isotopes of interest for nuclear applications, there are few benchmark evaluations for Pb systems. The lack of integral measurements to determine errors in Pb cross-section data has caused the latest nuclear cross-section libraries to over/underestimate k eff compared to experimental results. Therefore, this evaluation fills an important knowledge gap in benchmark evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DPM: A deep learning PDE augmentation method with application to large-eddy simulation

A framework is introduced that leverages known physics to reduce overfitting in machine learning for scientific applications. The partial differential equation (PDE) that expresses the physics is augmented with a neural network that uses available data to learn a description of the corresponding unknown or unrepresented physics. Training within this combined system corrects for missing, unknown, or erroneously represented physics, including discretization errors associated with the PDE's numerical solution. For optimization of the network within the PDE, an adjoint PDE is solved to provide high-dimensional gradients, and a stochastic adjoint method (SAM) further accelerates training. Additionally, the approach is demonstrated for large-eddy simulation (LES) of turbulence. High-fidelity direct numerical simulations (DNS) of decaying isotropic turbulence provide the training data used to learn sub-filter-scale closures for the filtered Navier–Stokes equations. Out-of-sample comparisons show that the deep learning PDE method outperforms widely-used models, even for filter sizes so large that they become qualitatively incorrect. It also significantly outperforms the same neural network when a priori trained based on simple data mismatch, not accounting for the full PDE. Measures of discretization errors, which are well-known to be consequential in LES, point to the importance of the unified training formulation's design, which without modification corrects for them. For comparable accuracy, simulation runtime is significantly reduced. A relaxation of the typical discrete enforcement of the divergence-free constraint in the solver is also successful, instead allowing the DPM to approximately enforce incompressibility physics. Since the training loss function is not restricted to correspond directly to the closure to be learned, training can incorporate diverse data, including experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bias Correction and Random Error Characterization for the Assimilation of HRDI Line-of-Sight Wind Measurements

A new approach to the analysis of systematic and random observation errors is presented in which the error statistics are obtained using forecast data rather than observations from a different instrument type. The analysis is carried out at an intermediate retrieval level, instead of the more typical state variable space. This method is carried out on measurements made by the High Resolution Doppler Imager (HRDI) on board the Upper Atmosphere Research Satellite (UARS). HRDI, a limb sounder, is the only satellite instrument measuring winds in the stratosphere, and the only instrument of any kind making global wind measurements in the upper atmosphere. HRDI measures doppler shifts in the two different O2 absorption bands (alpha and B) and the retrieved products are tangent point Line-of-Sight wind component (level 2 retrieval) and UV winds (level 3 retrieval). This analysis is carried out on a level 1.9 retrieval, in which the contributions from different points along the line-of-sight have not been removed. Biases are calculated from O-F (observed minus forecast) LOS wind components and are separated into a measurement parameter space consisting of 16 different values. The bias dependence on these parameters (plus an altitude dependence) is used to create a bias correction scheme carried out on the level 1.9 retrieval. The random error component is analyzed by separating the gamma and B band observations and locating observation pairs where both bands are very nearly looking at the same location at the same time. It is shown that the two observation streams are uncorrelated and that this allows the forecast error variance to be estimated. The bias correction is found to cut the effective observation error variance in half.

Tangborn, Andrew↗

Simultaneous x-ray diffraction measurements of nine pressure calibrants to 140 GPa

Accurate pressure calibration is fundamental to quantitative high-pressure science, yet inconsistencies among widely used secondary pressure scales persist. In this work, we report simultaneous synchrotron x-ray diffraction meatogether in diamond anvil cells to 140 GPa. This simultaneous-measurement strategy minimizes transitive errors and run-to-run inconsistencies inherent to paired-measurement approaches, yielding direct experimental volume-volume (V-V) relations among the calibrants. These V-V relations link the compression state of each phase to that of every other phase measured in the same experiment. By anchoring these V-V relations to the reduced 300 K equation of state (EOS) of copper derived from ramp-compression measurements, we derive an internally consistent set of Cu-referenced pressure scales via Vinet EOS fits. Because the primary experimental result is the V-V dataset, it provides an EOS-independent constraint that can be rereferenced if primary standards are revised. The dataset further enables a direct experimental cross-check of consistency between the adopted reduced 300 K Cu EOS and the corresponding reduced 300 K ramp-derived EOSs for Pt, Au, Ta, and hcp-Fe under a fixed V-V constraint. The residuals quantify small, material-dependent mismatches between each phase EOS and the Cu reference EOS.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Water vapor differential absorption lidar development and evaluation

A ground-based differential absorption lidar (DIAL) system is described which has been developed for vertical range-resolved measurements of water vapor. The laser transmitter consists of a ruby-pumped dye laser, which is operated on a water vapor absorption line at 724.372 nm. Part of the ruby laser output is transmitted simultaneously with the dye laser output to determine atmospheric scattering and attenuation characteristics. The dye and ruby laser backscattered light is collected by a 0.5-m diam telescope, optically separated in the receiver package, and independently detected using photomultiplier tubes. Measurements of vertical water vapor concentration profiles using the DIAL system at night are discussed, and comparisons are made between the water vapor DIAL measurements and data obtained from locally launched rawinsondes. Agreement between these measurements was found to be within the uncertainty of the rawinsonde data to an altitude of 3 km. Theoretical simulations of this measurement were found to give reasonably accurate predictions of the random error of the DIAL measurements. Confidence in these calculations will permit the design of aircraft and Shuttle DIAL systems and experiments using simulation results as the basis for defining lidar system performance requirements

Browell, E. V.↗

Aeolus -A Mission to Study the Thermal and Wind Environment of Mars

Aeolus is a small satellite mission to observe surface and atmospheric forcing and general circulation of Mars, by measuring surface energy balance, atmospheric temperatures, aerosols and clouds, and winds. Critically, Aeolus will make these measurements at all local times of day, providing information on both seasonal and diurnal variability. To date, direct measurements of Martian wind speeds have only been possible at the surface, only during daylight hours, and over small areas limited by rover traverse capabilities. From orbit, thermal measurements (e.g., estimates from assumed geostrophic balance) as well as images of dust storms and dune migration have provided inputs to derive current data sets on Martian winds. However, Mars General Circulation models demonstrate that wind speeds derived from these indirect measurements may be in error by 50 to 100%. For this reason, direct wind velocity measurements have been deemed "High Priority" by MEPAG (Mars Exploration Program Analysis Group); measuring wind speeds and corresponding thermal data is vital to understanding the climate of Mars. Aeolus will carry four Spatial Heterodyne Spectrometers (SHS), coupled to two orthogonal viewing telescopes. These high-resolution near-infrared spectrometers will measure CO2 (daytime absorption) and O2 (day and night emission) lines in the Martian atmosphere. Doppler shifts in these lines can be measured during Martian day and night, resolving wind speeds down to ~5 m/s. Orthogonal views allow the spectrometers to capture wind vectors over all observation locations. Aeolus will also carry the atmospheric limb-viewing Thermal Limb Sounder (TLS) to measure atmospheric temperatures, water ice clouds, and dust abundances across all altitudes where winds are measured. Finally, the Surface Radiometric Sensor Package (SuRSeP), a nadir viewing radiometer, will measure the total reflected solar and emitted thermal radiance, surface temperature, and water cloud and dust total column abundances. The combined spectral and thermal measurements will provide a new understanding of the global energy balance, dust transport processes, and climate cycles in the Martian atmosphere. Aeolus will consist of a single satellite in a near-polar orbit, allowing it to pass over all local times, with the baseline mission observing all seasons of an entire Martian year (two Earth years). Aeolus was one of two Martian smallsat concepts selected for study through the Planetary Science Deep Space SmallSat Studies program. This talk will provide an overview of the mission, including science rationale, instruments, spacecraft, and mission operations concept.

and winds↗