Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

A needle guidance system for biopsy and therapy using two-dimensional ultrasound

Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application- and patient size-dependent optimization of x-ray spectra for CT

Although x-ray computed tomography (CT) has been in clinical use for over 3 decades, spectral optimization has not been a topic of great concern; high voltages around 120 kV have been in use since the beginning of CT. It is the purpose of this study to analyze, in a rigorous manner, the energies at which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) for various diagnostic tasks can be minimized. The authors used cylindrical water phantoms and quasianthropomorphic phantoms of the thorax and the abdomen with inserts of 13 mm diameter mimicking soft tissue, bone, and iodine for simulations and measurements. To provide clearly defined contrasts, these inserts were made of solid water with a 1% difference in density (DD) to represent an energy-independent soft-tissue contrast of 10 Hounsfield units (HU), calcium hydroxyapatite (Ca) representing bone, and iodine (I) representing the typical contrast medium. To evaluate CT of the thorax, an adult thorax phantom (300x200 mm{sup 2}) plus extension rings up to a size of 460x300 mm{sup 2} to mimic different patient cross sections were used. For CT of the abdomen, we used a phantom of 360x200 mm{sup 2} and an extension ring of 460x300 mm{sup 2}. The CT scanner that the authors used was a SOMATOM Definition (Siemens Healthcare, Forchheim, Germany) at 80, 100, 120, and 140 kV. Further voltage settings of 60, 75, 90, and 105 kV were available in an experimental mode. The authors determined contrast for the density difference, calcium, and iodine, and noise and 3D dose distributions for the available voltages by measurements. Additional voltage values and monoenergetic sources were evaluated by simulations. The dose-weighted contrast-to-noise ratio (CNRD) was used as the parameter for optimization. Simulations and measurements were in good agreement with respect to absolute values and trends regarding the dependence on energy for the parameters investigated. For soft-tissue imaging, the standard settings of 120-140 kV were found as adequate choices with optimal values increasing for larger cross sections, e.g., for large abdomens voltages higher than 140 kV may be indicated. For bone and iodine imaging the optimum values were generally found at significantly lower voltages of typically below 80 kV. This offers a potential for dose reduction of up to 50%, but demands significantly higher power values in most cases. The authors concluded that voltage settings in CT should be varied more often than is common in practice today and should be chosen not only according to patient size but also according to the substance imaged in order to minimize dose while not compromising image quality. A reduction from 120 to 80 kV, for example, would yield a reduction in patient dose by more than half for coronary CT angiography. The use of lower voltages has to be recommended for contrast medium studies in cardiac and pediatric CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam

The aim of this work was to evaluate the performance of the voxel-based Monte Carlo algorithm implemented in the commercial treatment planning system ONCENTRA MASTERPLAN for a 9 MeV electron beam produced by a linear accelerator Varian Clinac 2100 C/D. In order to realize an experimental verification of the computed data, three different groups of tests were planned. The first set was performed in a water phantom to investigate standard fields, custom inserts, and extended treatment distances. The second one concerned standard field, irregular entrance surface, and oblique incidence in a homogeneous PMMA phantom. The last group involved the introduction of inhomogeneities in a PMMA phantom to simulate high and low density materials such as bone and lung. Measurements in water were performed by means of cylindrical and plane-parallel ionization chambers, whereas measurements in PMMA were carried out by the use of radiochromic films. Point dose values were compared in terms of percentage difference, whereas the gamma index tool was used to perform the comparison between computed and measured dose profiles, considering different tolerances according to the test complexity. In the case of transverse scans, the agreement was searched in the plane formed by the intersection of beam axis and the profile (2D analysis), while for percentage depth dose curves, only the beam axis was explored (1D analysis). An excellent agreement was found for point dose evaluation in water (discrepancies smaller than 2%). Also the comparison between planned and measured dose profiles in homogeneous water and PMMA phantoms showed good results (agreement within 2%-2 mm). Profile evaluation in phantoms with internal inhomogeneities showed a good agreement in the case of ''lung'' insert, while in tests concerning a small ''bone'' inhomogeneity, a discrepancy was particularly evidenced in dose values on the beam axis. This is due to the inaccurate geometrical description of the phantom that is linked to the calculation voxel size, a feature over which the user has no control.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and validation of a new guidance device for lateral approach stereotactic breast biopsy

Stereotactic breast biopsy (SBB) is the gold standard for minimally invasive breast cancer diagnosis. Current systems rely on one of two methods for needle insertion: A vertical approach (perpendicular to the breast compression plate) or a lateral approach (parallel to the compression plate). While the vertical approach is more frequently used, it is not feasible in patients with thin breasts (<3 cm thick after compression) or with superficial lesions. Further, existing SBB guidance hardware provides at most one degree of rotational freedom in the needle trajectory, and as such requires a separate skin incision for each biopsy target. The authors present a new design of lateral guidance device for SBB, which addresses the limitations of the vertical approach and provides improvements over the existing lateral guidance hardware. Specifically, the new device provides (1) an adjustable rigid needle support to minimize needle deflection within the breast and (2) an additional degree of rotational freedom in the needle trajectory, allowing the radiologist to sample multiple targets through a single skin incision. This device was compared to a commercial lateral guidance device in a series of phantom experiments. Needle placement error using each device was measured in agar phantoms for needle insertions at lateral depths of 2 and 5 cm. The biopsy success rate for each device was then estimated by performing biopsy procedures in commercial SBB phantoms. SBB performed with the new lateral guidance device provided reduced needle placement error relative to the commercial lateral guidance device (0.89{+-}0.22 vs 1.75{+-}0.35 mm for targets at 2 cm depth; 1.94{+-}0.20 vs 3.21{+-}0.31 mm for targets at 5 cm depth). The new lateral guidance device also provided improved biopsy accuracy in SBB procedures compared to the commercial lateral guidance device (100% vs 58% success rate). Finally, experiments were performed to demonstrate that the new device can accurately sample lesions within thin breast phantoms and multiple lesions through a single incision point. This device can be incorporated directly into the clinical SBB procedural workflow, with no additional electrical hardware, software, postprocessing, or image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A CT-based analytical dose calculation method for HDR {sup 192}Ir brachytherapy

Purpose: This article presents an analytical dose calculation method for high-dose-rate {sup 192}Ir brachytherapy, taking into account the effects of inhomogeneities and reduced photon backscatter near the skin. The adequacy of the Task Group 43 (TG-43) two-dimensional formalism for treatment planning is also assessed. Methods: The proposed method uses material composition and density data derived from computed tomography images. The primary and scatter dose distributions for each dwell position are calculated first as if the patient is an infinite water phantom. This is done using either TG-43 or a database of Monte Carlo (MC) dose distributions. The latter can be used to account for the effects of shielding in water. Subsequently, corrections for photon attenuation, scatter, and spectral variations along medium- or low-Z inhomogeneities are made according to the radiological paths determined by ray tracing. The scatter dose is then scaled by a correction factor that depends on the distances between the point of interest, the body contour, and the source position. Dose calculations are done for phantoms with tissue and lead inserts, as well as patient plans for head-and-neck, esophagus, and MammoSite balloon breast brachytherapy treatments. Gamma indices are evaluated using a dose-difference criterion of 3% and a distance-to-agreement criterion of 2 mm. PTRAN{sub C}T MC calculations are used as the reference dose distributions. Results: For the phantom with tissue and lead inserts, the percentages of the voxels of interest passing the gamma criteria (P{sub {gamma}{>=}1}) are 100% for the analytical calculation and 91% for TG-43. For the breast patient plan, TG-43 overestimates the target volume receiving the prescribed dose by 4% and the dose to the hottest 0.1 cm{sup 3} of the skin by 9%, whereas the analytical and MC results agree within 0.4%. P{sub {gamma}{>=}1} are 100% and 48% for the analytical and TG-43 calculations, respectively. For the head-and-neck and esophagus patient plans, P{sub {gamma}{>=}1} are {>=}99% for both calculation methods. Conclusions: A correction-based dose calculation method has been validated for HDR {sup 192}Ir brachytherapy. Its high calculation efficiency makes it feasible for use in treatment planning. Because tissue inhomogeneity effects are small and primary dose predominates in the near-source region, TG-43 is adequate for target dose estimation provided shielding and contrast solution are not used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional ultrasound system for guided breast brachytherapy

Breast-conserving surgery combined with subsequent radiation therapy is a standard procedure in breast cancer treatment. The disadvantage of whole-breast beam irradiation is that it requires 20-25 treatment days, which is inconvenient for patients with limited mobility or who reside far from the treatment center. However, interstitial high-dose-rate (HDR) brachytherapy is an irradiation method requiring only 5 treatment days and that delivers a lower radiation dose to the surrounding healthy tissue. It involves delivering radiation through {sup 192}Ir seeds placed inside the catheters, which are inserted into the breast. The catheters are attached to a HDR afterloader, which controls the seed placement within the catheters and irradiation times to deliver the proper radiation dose. One disadvantage of using HDR brachytherapy is that it requires performing at least one CT scan during treatment planning. The procedure at our institution involves the use of two CT scans. Performing CT scans requires moving the patient from the brachytherapy suite with catheters inserted in their breasts. One alternative is using three-dimensional ultrasound (3DUS) to image the patient. In this study, the authors developed a 3DUS translation scanning system for use in breast brachytherapy. The new system was validated using CT, the current clinical standard, to image catheters in a breast phantom. Once the CT and 3DUS images were registered, the catheter trajectories were then compared. The results showed that the average angular separation between catheter trajectories was 2.4 deg., the average maximum trajectory separation was 1.0 mm, and the average mean trajectory separation was found to be 0.7 mm. In this article, the authors present the 3DUS translation scanning system's capabilities as well as its potential to be used as the primary treatment planning imaging modality in breast brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo dosimetry for {sup 125}I and {sup 103}Pd eye plaque brachytherapy with various seed models

Purpose: Dose distributions are calculated for various models of {sup 125}I and {sup 103}Pd seeds in the standardized plaques of the Collaborative Ocular Melanoma Study (COMS). The sensitivity to seed model of dose distributions and dose distributions relative to TG-43 are investigated. Methods: Monte Carlo simulations are carried out with the EGSnrc user-code BrachyDose. Brachytherapy seeds and eye plaques are fully modeled. Simulations of one seed in the central slot of a 20 mm Modulay (gold alloy) plaque backing with and without the Silastic (silicone polymer) insert and of a 16 mm fully loaded Modulay/Silastic plaque are performed. Dose distributions are compared to those calculated under TG-43 assumptions, i.e., ignoring the effects of the plaque backing and insert and interseed attenuation. Three-dimensional dose distributions for different {sup 125}I and {sup 103}Pd seed models are compared via depth-dose curves, isodose contours, and tabulation of doses at points of interest in the eye. Results are compared to those of our recent BrachyDose study for COMS plaques containing model 6711 ({sup 125}I) or 200 ({sup 103}Pd) seeds [R. M. Thomson et al., Med. Phys. 35, 5530-5543 (2008)]. Results: Along the central axis of a plaque containing one seed, variations of less than 1% are seen in the effect of the Modulay backing alone for different seed models; for the Modulay/Silastic combination, variations are 2%. For a 16 mm plaque fully loaded with {sup 125}I ({sup 103}Pd) seeds, dose decreases relative to TG-43 doses are 11%-12% (19%-20%) and 14%-15% (20%) at distances of 0.5 and 1 cm from the inner sclera along the plaque's central axis, respectively. For the same prescription dose, doses at points of interest vary by up to 8% with seed model. Doses to critical normal structures are lower for all {sup 103}Pd seed models than for {sup 125}I with the possible exception of the sclera adjacent to the plaque; scleral doses vary with seed model and are not always higher for {sup 103}Pd than for {sup 125}I. Conclusions: Dose decreases relative to doses calculated under TG-43 assumptions vary slightly with seed model (for each radionuclide). Dose distributions are sensitive to seed model; however, variations are generally no larger than the magnitudes of other systematic uncertainties in eye plaque therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of a realistic breathing lung phantom to evaluate dose delivery errors

Purpose: To compare the effect of respiration-induced motion on delivered dose (the interplay effect) for different treatment techniques under realistic clinical conditions. Methods: A flexible resin tumor model was created using rapid prototyping techniques based on a computed tomography (CT) image of an actual tumor. Twenty micro-MOSFETs were inserted into the tumor model and the tumor model was inserted into an anthropomorphic breathing phantom. Phantom motion was programed using the motion trajectory of an actual patient. A four-dimensional CT image was obtained and several treatment plans were created using different treatment techniques and planning systems: Conformal (Eclipse), step-and-shoot intensity-modulated radiation therapy (IMRT) (Pinnacle), step-and-shoot IMRT (XiO), dynamic IMRT (Eclipse), complex dynamic IMRT (Eclipse), hybrid IMRT [60% conformal, 40% dynamic IMRT (Eclipse)], volume-modulated arc therapy (VMAT) [single-arc (Eclipse)], VMAT [double-arc (Eclipse)], and complex VMAT (Eclipse). The complex plans were created by artificially pushing the optimizer to give complex multileaf collimator sequences. Each IMRT field was irradiated five times and each VMAT field was irradiated ten times, with each irradiation starting at a random point in the respiratory cycle. The effect of fractionation was calculated by randomly summing the measured doses. The maximum deviation for each measurement point per fraction and the probability that 95% of the model tumor had dose deviations less than 2% and 5% were calculated as a function of the number of fractions. Tumor control probabilities for each treatment plan were calculated and compared. Results: After five fractions, measured dose deviations were less than 2% for more than 95% of measurement points within the tumor model for all plans, except the complex dynamic IMRT, step-and-shoot IMRT (XiO), complex VMAT, and single-arc VMAT plans. Reducing the dose rate of the complex IMRT plans from 600 to 200 MU/min reduced the dose deviations to less than 2%. Dose deviations were less than 5% after five fractions for all plans, except the complex single-arc VMAT plan. Conclusions: Rapid prototyping techniques can be used to create realistic tumor models. For most treatment techniques, the dose deviations averaged out after several fractions. Treatments with unusually complicated multileaf collimator sequences had larger dose deviations. For IMRT treat-ments, dose deviations can be reduced by reducing the dose rate. For VMAT treatments, using two arcs instead of one is effective for reducing dose deviations.

60 APPLIED LIFE SCIENCES↗

Experimentally determined spectral optimization for dedicated breast computed tomography

Purpose: The current study aimed to experimentally identify the optimal technique factors (x-ray tube potential and added filtration material/thickness) to maximize soft-tissue contrast, microcalcification contrast, and iodine contrast enhancement using cadaveric breast specimens imaged with dedicated breast computed tomography (bCT). Secondarily, the study aimed to evaluate the accuracy of phantom materials as tissue surrogates and to characterize the change in accuracy with varying bCT technique factors. Methods: A cadaveric breast specimen was acquired under appropriate approval and scanned using a prototype bCT scanner. Inserted into the specimen were cylindrical inserts of polyethylene, water, iodine contrast medium (iodixanol, 2.5 mg/ml), and calcium hydroxyapatite (100 mg/ml). Six x-ray tube potentials (50, 60, 70, 80, 90, and 100 kVp) and three different filters (0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn) were tested. For each set of technique factors, the intensity (linear attenuation coefficient) and noise were measured within six regions of interest (ROIs): Glandular tissue, adipose tissue, polyethylene, water, iodine contrast medium, and calcium hydroxyapatite. Dose-normalized contrast to noise ratio (CNRD) was measured for pairwise comparisons among the six ROIs. Regression models were used to estimate the effect of tube potential and added filtration on intensity, noise, and CNRD. Results: Iodine contrast enhancement was maximized using 60 kVp and 0.2 mm Cu. Microcalcification contrast and soft-tissue contrast were maximized at 60 kVp. The 0.2 mm Cu filter achieved significantly higher CNRD for iodine contrast enhancement than the other two filters (p=0.01), but microcalcification contrast and soft-tissue contrast were similar using the copper and aluminum filters. The average percent difference in linear attenuation coefficient, across all tube potentials, for polyethylene versus adipose tissue was 1.8%, 1.7%, and 1.3% for 0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn, respectively. For water versus glandular tissue, the average percent difference was 2.7%, 3.9%, and 4.2% for the three filter types. Conclusions: Contrast-enhanced bCT, using injected iodine contrast medium, may be optimized for maximum contrast of enhancing lesions at 60 kVp with 0.2 mm Cu filtration. Soft-tissue contrast and microcalcification contrast may also benefit from lower tube potentials (60 kVp). The linear attenuation coefficients of water and polyethylene slightly overestimate the values of their corresponding tissues, but the reported differences may serve as guidance for dosimetry and quality assurance using tissue equivalent phantoms.

60 APPLIED LIFE SCIENCES↗

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron dose equivalent measured at the maze door with various openings for the jaws and MLC

Purpose: This study was undertaken to explore the effects of the jaws and the MLC openings on the neutron dose equivalent (DE) at the maze door and neutron flux at the patient plane. Methods: The neutron dose equivalent was measured at the maze entrance door of a 15 MV therapy linear accelerator room. All measurements were performed using various field sizes up to 40 cm x 40 cm. Activation detectors constructed from natural Indium (In) were exposed at Cd envelope to neutrons in order to estimate relative changes of epithermal neutron fluences in the patient plane. Results: Our study showed that the dose equivalent at the maze door is at the highest when the jaw are closed and that maximal jaws opening reduces the DE by more than 20%. The neutron dose equivalent at the maze door measured for radiation fields defined by jaws do not differ significantly from the DE measured when MLC determines the same size radiation field. The epithermal capture reaction rate measured using different jaw openings differs by approximately 10%. When an MLC leaf is inserted into a fixed geometry for one opening of the jaws, an increase of the epithermal neutron capture reaction rate in Indium activation detectors was observed. Conclusions: There is no significant difference in the neutron DE when MLC defines radiation field instead of jaws. This leads to the conclusion that the overall number of neutrons remains similar and it does not depend on how primary photon beam was stopped--by the jaws or the MLC. An increase of the fast neutron capture reaction rate when MLC leaves are inserted probably originates from the neutron scattering.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computerized scheme for evaluating mammographic phantom images

Purpose: The authors developed a computer algorithm to automatically evaluate images of the American College of Radiology (ACR) mammography accreditation phantom. Methods: The developed algorithm consist of the edge detection of wax insert, nonuniformity correction of background, and correction for magnification and also calculate the cross-correlation coefficient by image matching technique. The algorithm additionally evaluates target shape for fibers, target contrast for speck groups, and target circularity for masses. To obtain an ideal template image without noise and spatial resolution loss, the wax insert containing the embedded test pattern was extracted from the phantom and radiographed. Two template images and ten test phantom images were prepared for this study. The results of evaluation using the algorithm outputs were compared with the averaged results of observer studies by six skilled observers. Results: In comparing the results from the algorithm outputs with the results of observers, the authors found that the computer outputs were well correlated with the evaluations by observers, and they indicate the quality of the phantom image. The correlation coefficients between results of observer studies and two outputs of computer algorithm, i.e., the cross-correlation coefficient by template matching and indices of target shape for fibers, were 0.89 (95% confidence interval, 0.82-0.93; hereinafter the same) and 0.85 (0.76-0.91). The correlation coefficients between observer's results and two outputs: the cross-correlation coefficient and indices of target contrast for speck groups, were 0.83 (0.79-0.86) and 0.85 (0.81-0.88) and between observer's results and two outputs: the cross-correlation coefficient and indices of target circularity for masses, were 0.90 (0.84-0.94) and 0.87 (0.77-0.92). Conclusions: Image evaluation using the ACR phantom is indispensable in quality control of a mammography system. The proposed algorithm is useful for quality control and image evaluation of mammography units.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship

Purpose: The conversion of the computed tomography (CT) number to electron density is one of the main processes that determine the accuracy of patient dose calculations in radiotherapy treatment planning. However, the CT number and electron density of tissues cannot be generally interrelated via a simple one-to-one correspondence because the CT number depends on the effective atomic number as well as the electron density. The purpose of this study is to present a simple conversion from the energy-subtracted CT number ({Delta}HU) by means of dual-energy CT (DECT) to the relative electron density ({rho}{sub e}) via a single linear relationship. Methods: The {Delta}HU-{rho}{sub e} conversion method was demonstrated by performing analytical DECT image simulations that were intended to imitate a second-generation dual-source CT (DSCT) scanner with an additional tin filtration for the high-kV tube. The {Delta}HU-{rho}{sub e} calibration line was obtained from the image simulation with a 33 cm-diameter electron density calibration phantom equipped with 16 inserts including polytetrafluoroethylene, polyvinyl chloride, and aluminum; the elemental compositions of these three inserts were quite different to those of body tissues. The {Delta}HU-{rho}{sub e} conversion method was also applied to previously published experimental CT data, which were measured using two different CT scanners, to validate the clinical feasibility of the present approach. In addition, the effect of object size on {rho}{sub e}-calibrated images was investigated by image simulations using a 25 cm-diameter virtual phantom for two different filtrations: with and without the tin filter for the high-kV tube. Results: The simulated {Delta}HU-{rho}{sub e} plot exhibited a predictable linear relationship over a wide range of {rho}{sub e} from 0.00 (air) to 2.35 (aluminum). Resultant values of the coefficient of determination, slope, and intercept of the linear function fitted to the data were close to those of the ideal case. The maximum difference between the ideal and simulated {rho}{sub e} values was -0.7%. The satisfactory linearity of {Delta}HU-{rho}{sub e} was also confirmed from analyses of the experimental CT data. In the experimental cases, the maximum difference between the nominal and simulated {rho}{sub e} values was found to be 2.5% after two outliers were excluded. When compared with the case without the tin filter, the {Delta}HU-{rho}{sub e} conversion performed with the tin filter yielded a lower dose and more reliable {rho}{sub e} values that were less affected by the object-size variation. Conclusions: The {Delta}HU-{rho}{sub e} calibration line with a simple one-to-one correspondence would facilitate the construction of a well-calibrated {rho}{sub e} image from acquired dual-kV images, and currently, second generation DSCT may be a feasible modality for the clinical use of the {Delta}HU-{rho}{sub e} conversion method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method of dose reconstruction for moving targets compatible with dynamic treatments

Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and dynamic multileaf collimator (DMLC) tracking. Methods: An in-house computer program was developed to manipulate Dicom treatment plans exported from a TPS (Eclipse, Varian Medical Systems) such that target motion during treatment delivery was incorporated into the plans. For each treatment, a motion including plan was generated by dividing the intratreatment target motion into 1 mm position bins and construct sub-beams that represented the parts of the treatment that were delivered, while the target was located within each position bin. For each sub-beam, the target shift was modeled by a corresponding isocenter shift. The motion incorporating Dicom plans were reimported into the TPS, where dose calculation resulted in motion including target dose distributions. For experimental validation of the dose reconstruction a thorax phantom with a moveable lung equivalent rod with a tumor insert of solid water was first CT scanned. The tumor insert was delineated as a gross tumor volume (GTV), and a planning target volume (PTV) was formed by adding margins. A conformal plan, two IMRT plans (step-and-shoot and sliding windows), and a VMAT plan were generated giving minimum target doses of 95% (GTV) and 67% (PTV) of the prescription dose (3 Gy). Two conformal fields with MLC leaves perpendicular and parallel to the tumor motion, respectively, were generated for DMLC tracking. All treatment plans were delivered to the thorax phantom without tumor motion and with a sinusoidal tumor motion. The two conformal fields were delivered with and without portal image guided DMLC tracking based on an embedded gold marker. The target dose distribution was measured with a radiochromic film in the moving rod and compared with the reconstructed doses using gamma tests. Results: Considerable interplay effects between machine motion and target motion were observed for the treatments without tracking. For nontracking experiments, the mean 2 mm/2% gamma pass rate over all investigated scenarios was 99.6% between calculated and measured doses. For tracking experiments, the mean gamma pass rate was 99.4%. Conclusions: A method for accurate dose reconstruction for moving targets with dynamic treatments was developed and experimentally validated in a variety of delivery scenarios. The method is suitable for integration into TPSs, e.g., for reconstruction of the dose delivered to moving tumors or calculation of target doses delivered with DMLC tracking.

60 APPLIED LIFE SCIENCES↗

The need for application-based adaptation of deformable image registration

Purpose: To utilize a deformable phantom to objectively evaluate the accuracy of 11 different deformable image registration (DIR) algorithms. Methods: The phantom represents an axial plane of the pelvic anatomy. Urethane plastic serves as the bony anatomy and urethane rubber with three levels of Hounsfield units (HU) is used to represent fat and organs, including the prostate. A plastic insert is placed into the phantom to simulate bladder filling. Nonradiopaque markers reside on the phantom surface. Optical camera images of these markers are used to measure the positions and determine the deformation from the bladder insert. Eleven different DIR algorithms are applied to the full and empty-bladder computed tomography images of the phantom (fixed and moving volumes, respectively) to calculate the deformation. The algorithms include those from MIM Software (MIM) and Velocity Medical Solutions (VEL) and nine different implementations from the deformable image registration and adaptive radiotherapy toolbox for Matlab. These algorithms warp one image to make it similar to another, but must utilize a method for regularization to avoid physically unrealistic deformation scenarios. The mean absolute difference (MAD) between the HUs at the marker locations on one image and the calculated location on the other serves as a metric to evaluate the balance between image similarity and regularization. To demonstrate the effect of regularization on registration accuracy, an additional beta version of MIM was created with a variable smoothness factor that controls the emphasis of the algorithm on regularization. The distance to agreement between the measured and calculated marker deformations is used to compare the overall spatial accuracy of the DIR algorithms. This overall spatial accuracy is also utilized to evaluate the phantom geometry and the ability of the phantom soft-tissue heterogeneity to represent patient data. To evaluate the ability of the DIR algorithms to accurately transfer anatomical contours, the rectum is delineated on both the fixed and moving images. A Dice similarity coefficient is then calculated between the contour on the fixed image and that transferred, via the calculated deformation, from the moving to the fixed image. Results: The phantom possesses sufficient soft-tissue heterogeneity to act as a proxy for patient data. Large discrepancies appear between the algorithms and the measured ground-truth deformation. VEL yields the smallest mean spatial error and a Dice coefficient of 0.90. MIM produces the lowest MAD value and the highest Dice coefficient of 0.96, but creates the largest spatial errors. Increasing the MIM smoothness factor above the default value improves the overall spatial accuracy, but the factor associated with the lowest mean error decreases the Dice coefficient to 0.85. Conclusions: Different applications of DIR require disparate balances between image similarity and regularization. A DIR algorithm that is optimized only for its ability to transfer anatomical contours will yield large deformation errors in homogeneous regions, which is problematic for dose mapping. For this reason, these algorithms must be tested for their overall spatial accuracy. The developed phantom is an objective tool for this purpose.

60 APPLIED LIFE SCIENCES↗

Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions: The proposed needle segmentation algorithm is accurate, robust, and suitable for 3D TRUS guided prostate transperineal therapy.

60 APPLIED LIFE SCIENCES↗

Evaluation of plastic materials for range shifting, range compensation, and solid-phantom dosimetry in carbon-ion radiotherapy

Purpose: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of range shifting and compensating materials. In dosimetry, solid phantoms are often used for convenience. These materials should ideally be equivalent to water. In this study, the authors evaluated dosimetric water equivalence of four common plastics, high-density polyethylene (HDPE), polymethyl methacrylate (PMMA), polyethylene terephthalate (PET), and polyoxymethylene (POM). Methods: Using the Bethe formula for energy loss, the Gottschalk formula for multiple scattering, and the Sihver formula for nuclear interactions, the authors calculated the effective densities of the plastics for these interactions. The authors experimentally measured variation of the Bragg peak of carbon-ion beams by insertion of HDPE, PMMA, and POM, which were compared with analytical model calculations. Results: The theoretical calculation resulted in slightly reduced multiple scattering and severely increased nuclear interactions for HDPE, compared to water and the other plastics. The increase in attenuation of carbon ions for 20-cm range shift was experimentally measured to be 8.9% for HDPE, 2.5% for PMMA, and 0.0% for POM while PET was theoretically estimated to be in between PMMA and POM. The agreement between the measurements and the calculations was about 1% or better. Conclusions: For carbon-ion beams, POM was dosimetrically indistinguishable from water and the best of the plastics examined in this study. The poorest was HDPE, which would reduce the Bragg peak by 0.45% per cm range shift, although with marginal superiority for reduced multiple scattering. Between the two clear plastics, PET would be superior to PMMA in dosimetric water equivalence.

36 MATERIALS SCIENCE↗