Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

2.8-Å crystal structure of Escherichia coli YidC revealing all core regions, including flexible C2 loop

YidC/Alb3/Oxa1 family proteins are involved in the insertion and assembly of membrane proteins. The core five transmembrane regions of YidC, which are conserved in the protein family, form a positively charged cavity open to the cytoplasmic side. The cavity plays an important role in membrane protein insertion. In all reported structural studies of YidC, the second cytoplasmic loop (C2 loop) was disordered, limiting the understanding of its role. Here, we determined the crystal structure of YidC including the C2 loop at 2.8 Å resolution with R/R{sub free} = 21.8/27.5. This structure and subsequent molecular dynamics simulation indicated that the intrinsic flexible C2 loop covered the positively charged cavity. This crystal structure provides the coordinates of the complete core region including the C2 loop, which is valuable for further analyses of YidC.

60 APPLIED LIFE SCIENCES↗

Structural basis for multiple gene regulation by human DUX4

Highlights: • DUX4 is a master regulator that controls the expression of multiple genes. • DUX4-DH/DNA complex structure was solved at high resolution. • DH1 and DH2 domains of DUX4 play important role in consensus sequence recognition. • DUX4 can tolerate length and/or identity variation in target DNA linker region. DUX4 plays critical role in the molecular pathogenesis of the neuromuscular disorder facioscapulohumeral muscular dystrophy and acute lymphoblastic leukemia in humans. As a master transcription regulator, DUX4 can also bind the promoters and activate the transcription of hundreds ZGA-associated genes. Here we report on the structural and biochemical studies of DUX4 double homeodomains (DUX4-DH), representing the only structures contain both homeodomain 1 (HD1) and homeodomain 2 (HD2). HD1 and HD2 adopt classical homeobox fold; via the helix inserted into the major groove and the N-terminal extended loop inserted into the minor groove, HD1 and HD2 recognize the box1 (5′-TAA-3′) and box2 (5′-TGA-3′) nucleotides of the consensus sequence, respectively. Among the box1 and box2 linking nucleotides (CCTAA), the two adenine residues are reported to be highly conserved; however, they are not directly recognized by DUX4-DH in the structures. Besides different nucleotides, our ITC analysis indicated that DUX4-DH can also tolerate various changes in the linker length. Our studies not only revealed the basis for target DNA recognition by DUX4, but also advanced our understanding on multiple gene activation by DUX4.

60 APPLIED LIFE SCIENCES↗

Membrane hydrophobicity determines the activation free energy of passive lipid transport

The collective behavior of lipids with diverse chemical and physical features determines a membrane's thermodynamic properties. Yet, the influence of lipid physicochemical properties on lipid dynamics, in particular interbilayer transport, remains underexplored. Here, we systematically investigate how the activation free energy of passive lipid transport depends on lipid chemistry and membrane phase. Through all-atom molecular dynamics simulations of 11 chemically distinct glycerophospholipids, we determine how lipid acyl chain length, unsaturation, and headgroup influence the free energy barriers for two elementary steps of lipid transport: lipid desorption, which is rate limiting, and lipid insertion into a membrane. Consistent with previous experimental measurements, we find that lipids with longer, saturated acyl chains have increased activation free energies compared to lipids with shorter, unsaturated chains. Lipids with different headgroups exhibit a range of activation free energies; however, no clear trend based solely on chemical structure can be identified, mirroring difficulties in the interpretation of previous experimental results. Compared to liquid-crystalline phase membranes, gel phase membranes exhibit substantially increased free energy barriers. Overall, we find that the activation free energy depends on a lipid's local hydrophobic environment in a membrane and that the free energy barrier for lipid insertion depends on a membrane's interfacial hydrophobicity. Both of these properties can be altered through changes in lipid acyl chain length, lipid headgroup, and membrane phase. Thus, the rate of lipid transport can be tuned through subtle changes in local membrane composition and order, suggesting an unappreciated role for nanoscale membrane domains in regulating cellular lipid dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

1-D NiO nanorods pillared 2-D MnO 2 nanosheets as lithium-free cathode materials for charged-state lithium batteries

Theoretically monolayer MnO 2 sheets have an impressive high capacity of 616 mAh/g, but practically monolayer MnO 2 sheets have poor performances due partially to monolayer restacking. In this paper, we report the preparation of three-dimensional porous NiO nanorod pillared δ-MnO 2 nanosheets as integrated nanoarchitectures as lithium-free cathode materials. The as-synthesized NiO pillared δ-MnO 2 nanosheets have resulted in a moderately high specific capacity of 185 mA h g –1 , with more than 63% capacity retention after 200 cycles. In comparison, 2D MnO 2 nanosheets without NiO pillared structures only achieved a low initial capacity of 137 mA h g –1 , with just 17% capacity retention after 200 cycles. The dramatically improved electrochemical performances could be attributed to high surface areas with excellent porosity which provides more electrochemically active sites and thermodynamically favorable insertion pathways for the lithium ions. Furthermore, our results reveal that insertion of pillars is a promising strategy to explore in order to mitigate the restacking issues and achieve electrochemical performances close to theoretical values for monolayer MnO 2 .

25 ENERGY STORAGE↗

Human tear-production rate from closed-eye Schirmer-strip capillary dynamics

A Schirmer tear test (STT) is commonly used to gauge human tear production, especially when dry-eye symptoms present. In an STT, the rounded tip of a standardized paper strip is inserted into the lower fornix of the eye, and the wetted length extending out from the lower lid is recorded after 5 min of eye closure. Longer wetted lengths suggest higher tear production rates. To date, however, there is no methodology to transform STT transient wetting lengths into basal tear- production rates. We develop a physical model to elucidate wetting kinetics in a Schirmer strip. Tear evaporation from the exposed portion of the strip and gravity are accounted for. Careful consideration of the initial depletion of tear in the closed-eye tear prism reveals an initial fast increase in wetted length followed by slower growth. Excellent agreement of the proposed model is achieved with experimental observation. When evaporation is negligible, the slow-growth regime exhibits a linear increase of wetted length in time. The linear-length-growth time regime permits simple calculation of quantitative tear-production rates. In this paper, we suggest measuring several dynamic wetting lengths along a sheathed Schirmer strip and near the 5-min insertion duration followed by fitting to a straight line. The slope of the length-versus-time data gives the basal lacrimal-supply rate.

59 BASIC BIOLOGICAL SCIENCES↗

New-to-nature chemistry from old protein machinery: carbene and nitrene transferases

Hemoprotein-catalyzed carbene and nitrene transformations have emerged as powerful tools for constructing complex molecules; they also nicely illustrate how new protein catalysts can emerge, evolve and diversify. These laboratory-invented enzymes exploit the ability of proteins to tame highly reactive carbene and nitrene species and direct their fates with high selectivity. New-to-nature carbene and nitrene transferases catalyze many useful reactions, including some that have no precedent using chemical methods. Here we cover recent advances in this field, including alkyne cyclopropenation, arene cyclopropanation, carbene C–H insertion, intramolecular nitrene C–H insertion, alkene aminohydroxylation, and primary amination. For such transformations, biocatalysts have exceeded the performance of reported small-molecule catalysts in terms of selectivity and catalyst turnovers. Lastly, we offer our thoughts on using these new enzymatic reactions in chemical synthesis, integrating them into biological pathways and chemo-enzymatic cascades, and on their current limitations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of high heat flux components for DIII-D neutral beam upgrades

Upgrade of the DIII-D neutral beams leads to enhanced heat loads on many components, such as calorimeter, collimator, and pole shields which protect neutral beam magnets. Power increase from 2.6 MW to 3.2 MW per source leads to a normal heat flux loads of up to 55 MW/m2 for the calorimeter. The Princeton Plasma Physics Laboratory is responsible for the design and manufacturing of the upgrades of these components. Heat flux distribution on neutral beam components is very uneven and leads to significant thermal stresses. High heat flux density impact requires surface optimization to reduce surface heat flux projection, and avoid localized melting. Several new design features were introduced to accommodate increased heat loads, such as molybdenum inserts for the pole shields, two-dimensional shaping for the calorimeter, and three-dimensional shape optimization and replaceable copper inserts for the collimator. Also, all three components include an optimized cooling system design featuring peripheral cooling of copper components. The optimization process included applying analytical relations for the transient temperature distributions on the high heat flux components. These relations were confirmed by previous DIII-D experimental results. To confirm the designs, numerical simulations were performed. Results of the design optimization and numerical simulations will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution

Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.

42 ENGINEERING↗

Accessing the second electron capacity of MnO 2 by exploring complexation and intercalation reactions in energy dense alkaline batteries

MnO 2 is one of the safest and most abundant electrochemical materials available. It exhibits polymorphism, which has been exploited in many applications especially batteries. In alkaline batteries, γ-MnO 2 is widely used because its proton insertion reaction yields one e - (1st) per Mn at high voltages. It also gives a second (2nd) e - during dissolution-precipitation reactions that occur at lower voltages than the proton insertion; however, these 2nd e - reactions are highly irreversible. Here in this communication, here we explore the reversibility of the 2nd e - reactions with bismuth oxide (Bi 2 O 3 ) and copper (Cu) additives, and cycling in specific potential regions where δ-MnO 2 is the polymorph synthesized electrochemically in-situ from γ-MnO 2 . The use of Bi 2 O 3 and Cu add complexation and intercalation reactions, where presence and/or electrochemical activation of both are essential for reversibility and for capacity retention (50–100%). Attaining 300–610Wh kg -1 against a zinc anode is possible for these batteries, which could promote its use for many applications.

08 HYDROGEN↗

Californium-252 Brachytherapy Combined With External-Beam Radiotherapy for Cervical Cancer: Long-Term Treatment Results

Purpose: To observe, by retrospective analysis, the curative effects and complications due to californium-252 ({sup 252}Cf) neutron intracavitary brachytherapy (ICBT) combined with external-beam radiotherapy (EBRT) in the treatment of cervical cancer. Methods and Materials: From February 1999 to December 2007, 696 patients with cervical cancer (Stages IB to IIIB) were treated with {sup 252}Cf-ICBT in combination of EBRT. Of all, 31 patients were at Stage IB, 104 at IIA, 363 at IIB, 64 at IIIA, and 134 at IIIB. Californium-252 ICBT was delivered at 7-12 Gy per insertion per week, with a total dose of 29-45 Gy to reference point A in three to five insertions. The whole pelvic cavity was treated with 8-MV X-ray external irradiation at 2 Gy per fraction, four times per week. After 16-38 Gy of external irradiation, the center of the whole pelvic field was blocked with a 4-cm-wide lead shield, with a total external irradiation dose of 44-56 Gy. The total treatment course was 5 to 6 weeks. Results: Overall survival rate at 3 and 5 years for all patients was 76.0% and 64.9%, respectively. Disease-free 3- and 5-year survival rates of patients were 71.2% and 58.4%, respectively. Late complications included vaginal contracture and adhesion, radiation proctitis, radiation cystitis, and inflammatory bowel, which accounted for 5.8%, 7.1%, 6.2%, and 4.9%, respectively. Univariate analysis results showed significant correlation of stage, age, histopathologic grade, and lymph node status with overall survival. Cox multiple regression analysis showed that the independent variables were stage, histopathologic grade, tumor size, and lymphatic metastasis in all patients. Conclusion: Results of this series suggest that the combined use of {sup 252}Cf-ICBT with EBRT is an effective method for treatment of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Use of the Utrecht Applicator for Combined Intracavitary/Interstitial Brachytherapy Treatment in Locally Advanced Cervical Cancer

Purpose: The aims of this study were to investigate the benefit of the Utrecht interstitial CT/MR applicator for combined intracavitary/interstitial (IC/IS) approach, using magnetic resonance imaging-guided brachytherapy, over the intracavitary approach alone in patients with locally advanced cervical cancer and to analyze the clinical use of needles. Methods and Materials: This study includes the first 20 patients treated with the new applicator. Brachytherapy consisted of two pulsed dose rate applications, and the second application was performed with the IC/IS approach. The number of needles, chosen guiding holes through the ovoids, and insertion depths were based on the dose distribution and dosimetric shortcomings of the first application (IC alone). We investigated the dosimetric gain by comparing the clinical interstitial optimized plan (IC/IS{sub clinical}) with an additionally generated optimized plan without needle use (IC{sub study}). Furthermore, we studied the relation of the inserted needles and their source loading patterns with the high-risk clinical target volume (HR-CTV). Results: A total of 54 needles (range, 1-6 per application) were applied with an average depth of 25 mm. The chosen needle positions corresponded with the location of the HR-CTV extensions. The total and individual needle treatment times per application were on average 19% (range, 4-35%) and 7% (range, 2-14%) of the implant treatment time, respectively. The total (external-beam radiotherapy + brachytherapy) D90 HR-CTV for the IC{sub study} and the IC/IS{sub clinical} were on average 79.5 (SD 7.4) Gy{sub {alpha}/{beta}10} and 83.9 (SD 6.7) Gy{sub {alpha}/{beta}10}, respectively, with an average gain of 4.4 (SD 2.3) Gy{sub {alpha}/{beta}10} for the second application. Conclusions: Needle placement was feasible in all patients and resulted in a gain in dose and better coverage of HR-CTV. Defining the location of HR-CTV protrusions and analyzing the associated needles has given us deeper understanding of the possibilities in magnetic resonance imaging-guided (pre)treatment planning with the IC/IS Utrecht applicator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Learning and Memory Following Conformal Radiation Therapy for Pediatric Craniopharyngioma and Low-Grade Glioma

Purpose: The primary objective of this study was to examine whether children with low-grade glioma (LGG) or craniopharyngioma had impaired learning and memory after conformal radiation therapy (CRT). A secondary objective was to determine whether children who received chemotherapy before CRT, a treatment often used to delay radiation therapy in younger children with LGG, received any protective benefit with respect to learning. Methods and Materials: Learning and memory in 57 children with LGG and 44 children with craniopharyngioma were assessed with the California Verbal Learning Test-Children's Version and the Visual-Auditory Learning tests. Learning measures were administered before CRT, 6 months later, and then yearly for a total of 5 years. Results: No decline in learning scores after CRT was observed when patients were grouped by diagnosis. For children with LGG, chemotherapy before CRT did not provide a protective effect on learning. Multiple regression analyses, which accounted for age and tumor volume and location, found that children treated with chemotherapy before CRT were at greater risk of decline on learning measures than those treated with CRT alone. Variables predictive of learning and memory decline included hydrocephalus, shunt insertion, younger age at time of treatment, female gender, and pre-CRT chemotherapy. Conclusions: This study did not reveal any impairment or decline in learning after CRT in overall aggregate learning scores. However, several important variables were found to have a significant effect on neurocognitive outcome. Specifically, chemotherapy before CRT was predictive of worse outcome on verbal learning in LGG patients. In addition, hydrocephalus and shunt insertion in craniopharyngioma were found to be predictive of worse neurocognitive outcome, suggesting a more aggressive natural history for those patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific Quality Assurance for the Delivery of {sup 60}Co Intensity Modulated Radiation Therapy Subject to a 0.35-T Lateral Magnetic Field

Purpose: This work describes a patient-specific dosimetry quality assurance (QA) program for intensity modulated radiation therapy (IMRT) using ViewRay, the first commercial magnetic resonance imaging-guided RT device. Methods and Materials: The program consisted of: (1) a 1-dimensional multipoint ionization chamber measurement using a customized 15-cm{sup 3} cube-shaped phantom; (2) 2-dimensional (2D) radiographic film measurement using a 30- × 30- × 20-cm{sup 3} phantom with multiple inserted ionization chambers; (3) quasi-3D diode array (ArcCHECK) measurement with a centrally inserted ionization chamber; (4) 2D fluence verification using machine delivery log files; and (5) 3D Monte Carlo (MC) dose reconstruction with machine delivery files and phantom CT. Results: Ionization chamber measurements agreed well with treatment planning system (TPS)-computed doses in all phantom geometries where the mean ± SD difference was 0.0% ± 1.3% (n=102; range, −3.0%-2.9%). Film measurements also showed excellent agreement with the TPS-computed 2D dose distributions where the mean passing rate using 3% relative/3 mm gamma criteria was 94.6% ± 3.4% (n=30; range, 87.4%-100%). For ArcCHECK measurements, the mean ± SD passing rate using 3% relative/3 mm gamma criteria was 98.9% ± 1.1% (n=34; range, 95.8%-100%). 2D fluence maps with a resolution of 1 × 1 mm{sup 2} showed 100% passing rates for all plan deliveries (n=34). The MC reconstructed doses to the phantom agreed well with planned 3D doses where the mean passing rate using 3% absolute/3 mm gamma criteria was 99.0% ± 1.0% (n=18; range, 97.0%-100%), demonstrating the feasibility of evaluating the QA results in the patient geometry. Conclusions: We developed a dosimetry program for ViewRay's patient-specific IMRT QA. The methodology will be useful for other ViewRay users. The QA results presented here can assist the RT community to establish appropriate tolerance and action limits for ViewRay's IMRT QA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Clinical Implementation of a Novel Magnetic Resonance Tracking Device for Real-Time Brachytherapy Catheter Positioning

Purpose: We designed and built dedicated active magnetic resonance (MR)-tracked (MRTR) stylets. We explored the role of MRTR in a prospective clinical trial. Methods and Materials: Eleven gynecologic cancer patients underwent MRTR to rapidly optimize interstitial catheter placement. MRTR catheter tip location and orientation were computed and overlaid on images displayed on in-room monitors at rates of 6 to 16 frames per second. Three modes of actively tracked navigation were analyzed: coarse navigation to the approximate region around the tumor; fine-tuning, bringing the stylets to the desired location; and pullback, with MRTR stylets rapidly withdrawn from within the catheters, providing catheter trajectories for radiation treatment planning (RTP). Catheters with conventional stylets were inserted, forming baseline locations. MRTR stylets were substituted, and catheter navigation was performed by a clinician working inside the MRI bore, using monitor feedback. Results: Coarse navigation allowed repositioning of the MRTR catheters tips by 16 mm (mean), relative to baseline, in 14 ± 5 s/catheter (mean ± standard deviation [SD]). The fine-tuning mode repositioned the catheter tips by a further 12 mm, in 24 ± 17 s/catheter. Pullback mode provided catheter trajectories with RTP point resolution of ∼1.5 mm, in 1 to 9 s/catheter. Conclusions: MRTR-based navigation resulted in rapid and optimal placement of interstitial brachytherapy catheters. Catheters were repositioned compared with the initial insertion without tracking. In pullback mode, catheter trajectories matched computed tomographic precision, enabling their use for RTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determining the impacts of venoarterial extracorporeal membrane oxygenation on cerebral oxygenation using a one-dimensional blood flow simulator

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is a mechanical system that provides rapid and short-term support for patients with cardiac failure. In many patients, pulmonary function is also impaired, resulting in poorly-oxygenated cardiac outflow competing against well-oxygenated VA-ECMO outflow, a condition known as North-South syndrome. North-South syndrome is a primary concern because of its potential to cause cerebral hypoxia, which has a critical influence on neurological complications often seen in this patient population. In order to reduce ischemic neurological complications, it is important to understand how clinical decisions regarding VA-ECMO parameters influence blood oxygenation. In our work, we studied the impacts of flow rate and cannulation site on oxygenation using a one-dimensional (1D) model to simulate blood flow. Our model was initially tested by comparing blood flow results to those observed from experimental work in VA-ECMO patients. The 1D model was combined with a two-phase flow model to simulate oxygenation. Additionally, the influence of various other clinician-tunable parameters on oxygenation in the common carotid arteries (CCAs) were tested, including, blood viscosity, cannula position within the insertion artery, heart rate, and systemic vascular resistance (SVR), as well as geometrical changes such as arterial radius and length. Our results indicated that blood oxygenation to the brain strongly depended on the cannula insertion site and the VA-ECMO flow rate with a weaker but potentially significant dependence on arterial radius. During femoral cannulation, VA-ECMO flow rates greater than ~4.9 L/min were needed to perfuse the CCAs. However, axillary and central cannulation began to perfuse the CCAs at significantly lower flow (~1 L/min). These results may help explain the incidence of cerebral hypoxia in this patient population and the common need to change cannulation strategies during treatment to address this clinical problem. While this work describes patient-averaged results, determining these relationships between VA-ECMO parameters and cerebral hypoxia is an important step towards future work to develop patient-specific models that clinicians can use to improve outcomes.

1D blood flow↗

Structural Analysis of Protein Folding by the Long-Chain Archaeal Chaperone FKBP26

In the cell, protein folding is mediated by folding catalysts and chaperones. The two functions are often linked, especially when the catalytic module forms part of a multidomain protein, as in Methanococcus jannaschii peptidyl-prolyl cis/trans isomerase FKBP26. Here, we show that FKBP26 chaperone activity requires both a 50-residue insertion in the catalytic FKBP domain, also called 'Insert-in-Flap' or IF domain, and an 80-residue C-terminal domain. We determined FKBP26 structures from four crystal forms and analyzed chaperone domains in light of their ability to mediate protein-protein interactions. FKBP26 is a crescent-shaped homodimer. We reason that folding proteins are bound inside the large crescent cleft, thus enabling their access to inward-facing peptidyl-prolyl cis/trans isomerase catalytic sites and ipsilateral chaperone domain surfaces. As these chaperone surfaces participate extensively in crystal lattice contacts, we speculate that the observed lattice contacts reflect a proclivity for protein associations and represent substrate interactions by FKBP26 chaperone domains. Finally, we find that FKBP26 is an exceptionally flexible molecule, suggesting a mechanism for nonspecific substrate recognition.

59 BASIC BIOLOGICAL SCIENCES↗

Modifying the strength and strain concentration profile within collagen scaffolds using customizable arrays of poly-lactic acid fibers

Here, the tendon-to-bone junction is a highly specialized tissue which dissipates stress concentrations between mechanically dissimilar tendon and bone. Upon injury, the local heterogeneities across this insertion are not regenerated, leading to poor functional outcomes such as formation of scar tissue at the insertion and re-failure rates exceeding 90%. Although current tissue engineering methods are moving towards the development of spatially-graded biomaterials to begin to address these injuries, significant opportunities remain to engineer the often complex local mechanical behavior of such biomaterials to enhance their bioactivity. Here, we describe the use of three-dimensional printing techniques to create customizable arrays of poly-lactic acid (PLA) fibers that can be incorporated into a collagen scaffold under development for tendon bone junction repair. Notably, we use additive manufacturing concepts to generate arrays of spatially-graded fibers from biodegradable PLA that are incorporated into collagen scaffolds to create a collagen-PLA composite. We demonstrate the ability to tune the mechanical performance of the fiber-scaffold composite at the bulk scale. We also demonstrate the incorporation of spatially-heterogeneous fiber designs to establish non-uniform local mechanical performance of the composite biomaterial under tensile load, a critical element in the design of multi-compartment biomaterials for tendon-to-bone regeneration applications. Together, this work highlights the capacity to use multi-scale composite biomaterials to control local and bulk mechanical properties, and provides key insights into design elements under consideration for mechanically competent, multi-tissue regeneration platforms.

3D printing↗

X-ray and gamma-ray tomographic imaging of fuel relocation inside sodium fast reactor test assemblies during severe accidents

The present work reports on x-ray and gamma-ray high-spatial resolution computerized tomography measurements of the Pin Bundle Metallic Fuel Relocation (PBR) assemblies tested in the Metallic Uranium Safety Experiment (MUSE) facility at Argonne National Lab (ANL). The aim of the study was to characterize fuel relocation structures that develop during severe core accidents pertaining to SFR assemblies; these include but are not limited to advanced core disruption recreated in the PBR-1 assembly, and cladding breach recreated in the PBR-2 assembly. We report the x-ray tomography measurements were able to resolve small quantities of relocation fuel; with increased presence of relocation fuel, the x-ray 1measurements spatially mapped the material but could not resolve the inner regions of these. The gamma-tomography measurements showed improved results, resolving the relocation structures in great detail. The upper plenum of the PBR-1 assembly where the molten uranium was initially inserted presented high structural damage, reflected by the partial and complete disintegration of the central rods. Relocation fuel filled the subchannels, adhering to surviving cladding walls and the assembly casing. In the lower portion of the measured section, the tomogram degrades due to photon starvation effects hinting at the increased amount of relocation fuel potentially plugging the assembly; flow blockage in this section was difficult to determine due to the tomogram’s degradation from photon starvation. Small fragments were observed further down the assembly, dislodged from the initial insertion of the molten material. This section was used as an unperturbed assembly reference, with a calculated blockage of less than 1% from the present fragments. The PBR-2 assembly was characterized by columnar relocation structures propagating through the subchannels. Three of the relocation structures were captured in the measured section, with evidence of cross migration on to adjacent subchannels. The measured section in this assembly captures the leading edge of two structures. The calculated flow blockage was 16% in the planes where the three relocation structures are present, but this quickly decreases to approximately 5% past the leading edge of two of the structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗