Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “information analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

SINGLE-SHELL TANKS LEAK INTEGRITY ELEMENTS/SX FARM LEAK CAUSES AND LOCATIONS - 12127

Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-9IF Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal I-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and drywells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to leak detection. In-tank parameters can include temperature of the supernatant and sludge, types of waste, and chemical determination by either transfer or sample analysis. Ex-tank information can be assembled from many sources including design media, construction conditions, technical specifications, and other sources. Five conditions may have contributed to SX Farm tank liner failure including: tank design, thermal shock, chemistry-corrosion, liner behavior (bulging), and construction temperature. Tank design did not apparently change from tank to tank for the SX Farm tanks; however, there could be many unknown variables present in the quality of materials and quality of construction. Several significant SX Farm tank design changes occurred from previous successful tank farm designs. Tank construction occurred in winter under cold conditions which could have affected the ductile to brittle transition temperature of the tanks. The SX Farm tanks received high temperature boiling waste from REDOX which challenged the tank design with rapid heat up and high temperatures. All eight of the leaking SX Farm tanks had relatively high rate of temperature rise. Supernatant removal with subsequent nitrate leaching was conducted in all but three of the eight leaking tanks prior to leaks being detected. It is possible that no one characteristic of the SX Farm tanks could in isolation from the others have resulted in failure. However, the application of so many stressors - heat up rate, high temperature, loss of corrosion protection, and tank design - working jointly or serially resulted in their failure. Thermal shock coupled with the tank design, construction conditions, and nitrate leaching seem to be the overriding factors that can lead to tank liner failure. The distinction between leaking and sound SX Farm tanks seems to center on the waste types, thermal conditions, and nitrate leaching.

54 ENVIRONMENTAL SCIENCES↗

Single-Shell Tanks Leak Integrity Elements/ SX Farm Leak Causes and Locations - 12127

Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-91F Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal 1-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX- 111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and dry-wells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to leak detection. In-tank parameters can include temperature of the supernatant and sludge, types of waste, and chemical determination by either transfer or sample analysis. Ex-tank information can be assembled from many sources including design media, construction conditions, technical specifications, and other sources. Five conditions may have contributed to SX Farm tank liner failure including: tank design, thermal shock, chemistry-corrosion, liner behavior (bulging), and construction temperature. Tank design did not apparently change from tank to tank for the SX Farm tanks; however, there could be many unknown variables present in the quality of materials and quality of construction. Several significant SX Farm tank design changes occurred from previous successful tank farm designs. Tank construction occurred in winter under cold conditions which could have affected the ductile to brittle transition temperature of the tanks. The SX Farm tanks received high temperature boiling waste from REDOX which challenged the tank design with rapid heat up and high temperatures. All eight of the leaking SX Farm tanks had relatively high rate of temperature rise. Supernatant removal with subsequent nitrate leaching was conducted in all but three of the eight leaking tanks prior to leaks being detected. It is possible that no one characteristic of the SX Farm tanks could in isolation from the others have resulted in failure. However, the application of so many stressors - heat up rate, high temperature, loss of corrosion protection, and tank design working jointly or serially resulted in their failure. Thermal shock coupled with the tank design, construction conditions, and nitrate leaching seem to be the overriding factors that can lead to tank liner failure. The distinction between leaking and sound SX Farm tanks seems to center on the waste types, thermal conditions, and nitrate leaching. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Idaho National Laboratory Quarterly Performance Analysis for the 2nd Quarter FY 2015

This report is published quarterly by the Idaho National Laboratory (INL) Quality and Performance Management Organization. The Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS), as prescribed in DOE Order 232.2, “Occurrence Reporting and Processing of Operations Information,” requires a quarterly analysis of events, both reportable and not reportable, for the previous 12 months. This report is the analysis of events for the 2nd Qtr FY-15.

99 GENERAL AND MISCELLANEOUS↗

Idaho National Laboratory Quarterly Occurrence Analysis 4th Quarter FY 2017

This report is published quarterly by the Idaho National Laboratory (INL) Nuclear Safety, Quality, and Performance Management Organization. The Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS), as prescribed in DOE Order 232.2, “Occurrence Reporting and Processing of Operations Information,” requires a quarterly analysis of events, both reportable and not reportable events for the previous 12 months. This report is the analysis of 78 reportable events (16 from 4th quarter [Qtr] of fiscal year [FY]-2017 and 62 from the prior three reporting quarters), as well as 49 other issue reports (including events found to be not reportable and Significant Category A and B conditions) identified at INL during the past 12 months (14 from this quarter and 35 from the prior three quarters).

99 GENERAL AND MISCELLANEOUS↗

Idaho National Laboratory Quarterly Occurrence Analysis for the 2nd Quarter FY 2017

This report is published quarterly by the Idaho National Laboratory (INL) Quality and Performance Management Organization. The Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS), as prescribed in DOE Order 232.2, “Occurrence Reporting and Processing of Operations Information,” requires a quarterly analysis of events, both reportable and not reportable, for the previous 12 months. This report is the analysis of 89 reportable events (24 from 2nd quarter (Qtr) of fiscal year [FY]-2017 and 65 from the prior three reporting quarters), as well as 32 other issue reports (including events found to be not reportable and Significant Category A and B conditions) identified at INL during the past 12 months (seven from this quarter and 25 from the prior three quarters).

99 GENERAL AND MISCELLANEOUS↗

COL Application Content Guide for HTGRs: Revision to RG 1.206, Part 1 - Status Report

A combined license (COL) application is required by the Nuclear Regulatory Commission (NRC) for all proposed nuclear plants. The information requirements for a COL application are set forth in 10 CFR 52.79, “Contents of Applications; Technical Information in Final Safety Analysis Report.” An applicant for a modular high temperature gas-cooled reactor (HTGR) must develop and submit for NRC review and approval a COL application which conforms to these requirements. The technical information necessary to allow NRC staff to evaluate a COL application and resolve all safety issues related to a proposed nuclear plant is detailed and comprehensive. To this, Regulatory Guide (RG) 1.206, “Combined License Applications for Nuclear Power Plants” (LWR Edition), was developed to assist light water reactor (LWR) applicants in incorporating and effectively formatting required information for COL application review (Ref. 1). However, the guidance prescribed in RG 1.206 presumes a LWR design proposal consistent with the systems and functions associated with large LWR power plants currently operating under NRC license.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Guam100: Guam's 100% Renewable Energy Future

Guam100 is a comprehensive approach to providing analysis to support the transition to 100% renewable energy that considers future load growth, equity, and affordability as well as enhancing the reliability of Guam's electric grid. Guam community stakeholder input will inform the approach to analysis and modeling of future electricity needs, priorities (resilience, equity, and affordability), and resources to meet those needs.

energy burden↗

A new multifunction acousto-optic signal processor

An acousto-optic architecture for simultaneously obtaining time integration correlation and high-speed power spectrum analysis was constructed using commercially available TeO2 modulators and photodiode detector-arrays. The correlator section of the processor uses coherent interferometry to attain maximum bandwidth and dynamic range while achieving a time-bandwidth product of 1 million. Two correllator outputs are achieved in this system configuration. One is optically filtered and magnified 2 : 1 to decrease the spatial frequency to a level where a 25-MHz bandwidth may be sampled by a 62-mm array with elements on 25-micro centers. The other output is magnified by a factor of 10 such that the center 4 microseconds of information is available for estimation of time-difference-of-arrival to within 10 ns. The Bragg cell spectrum-analyzer section, which also has two outputs, resolves a 25-MHz instantaneous bandwidth to 25 kHz and can determine discrete-frequency reception time to within 15 microseconds. A microprocessor combines spectrum analysis information with that obtained from the correlator.

Berg, N. J.↗

Technology Assessment: Strategic Energy Analysis Center (SEAC) 2012 Highlights (Fact Sheet)

This fact sheet lists key analysis products produced by NREL in 2012. Like all NREL analysis products, these aim to increase the understanding of the current and future interactions and roles of energy policies, markets, resources, technologies, environmental impacts, and infrastructure. NREL analysis, data, and tools inform decisions as energy-efficient and renewable energy technologies advance from concept to commercial application.

1603↗

Nowcasting Earthquakes With Stochastic Simulations: Information Entropy of Earthquake Catalogs

Earthquake nowcasting has been proposed as a means of tracking the change in large earthquake potential in a seismically active area. The method was developed using observable seismic data, in which probabilities of future large earthquakes can be computed using Receiver Operating Characteristic methods. Furthermore, analysis of the Shannon information content of the earthquake catalogs has been used to show that there is information contained in the catalogs, and that it can vary in time. So an important question remains, where does the information originate? In this paper, we examine this question using stochastic simulations of earthquake catalogs. Our catalog simulations are computed using an Earthquake Rescaled Aftershock Seismicity (“ERAS”) stochastic model. This model is similar in many ways to other stochastic seismicity simulations, but has the advantage that the model has only 2 free parameters to be set, one for the aftershock (Omori-Utsu) time decay, and one for the aftershock spatial migration away from the epicenter. Generating a simulation catalog and fitting the two parameters to the observed catalog such as California takes only a few minutes of wall clock time. While clustering can arise from random, Poisson statistics, we show that significant information in the simulation catalogs arises from the “non-Poisson” power-law aftershock clustering, implying that the practice of de-clustering observed catalogs may remove information that would otherwise be useful in forecasting and nowcasting. We also show that the nowcasting method provides similar results with the ERAS model as it does with observed seismicity.

58 GEOSCIENCES↗

The Pilot Land Data System: Report of the Program Planning Workshops

An advisory report to be used by NASA in developing a program plan for a Pilot Land Data System (PLDS) was developed. The purpose of the PLDS is to improve the ability of NASA and NASA sponsored researchers to conduct land-related research. The goal of the planning workshops was to provide and coordinate planning and concept development between the land related science and computer science disciplines, to discuss the architecture of the PLDs, requirements for information science technology, and system evaluation. The findings and recommendations of the Working Group are presented. The pilot program establishes a limited scale distributed information system to explore scientific, technical, and management approaches to satisfying the needs of the land science community. The PLDS paves the way for a land data system to improve data access, processing, transfer, and analysis, which land sciences information synthesis occurs on a scale not previously permitted because of limits to data assembly and access.

Source record↗

Phase diagram features and solidification behaviour of CoCu{sub 2}O{sub 3} at elevated oxygen pressure

A unique behaviour of the phase CoCu{sub 2}O{sub 3} was found both from CALPHAD calculations and directional solidification experiments. For elevated oxygen partial pressure the solidification mode changed from double-peritectic to a congruent melting behaviour with respect to the metals (Cu, Co) and to the oxygen content. This transition predicted by the phase diagram calculations was confirmed by microstructure and phase analyses of samples solidified at oxygen pressures up to 60 bar. A DTA analysis has verified basic features of the phase diagram at normal pressures. - Graphical abstract: A unique behaviour of the phase CoCu{sub 2}O{sub 3} was found both from CALPHAD calculations and directional solidification experiments. For elevated oxygen partial pressure the solidification mode changed from double-peritectic (1 bar O{sub 2}; left figure) to a congruent melting behaviour with respect to the metals (Cu, Co) and to the oxygen content (80 bar O{sub 2}; right figure).

36 MATERIALS SCIENCE↗

Differentially Private Synthesis and Sharing of Network Data Via Bayesian Exponential Random Graph Models

Abstract Network data often contain sensitive relational information. One approach to protecting sensitive information while offering flexibility for network analysis is to share synthesized networks based on the information in originally observed networks. We employ differential privacy (DP) and exponential random graph models (ERGMs) and propose the DP-ERGM method to synthesize network data. We apply DP-ERGM to two real-world networks. We then compare the utility of synthesized networks generated by DP-ERGM, the DyadWise Randomized Response (DWRR) approach, and the Synthesis through Conditional distribution of Edge given nodal Attribute (SCEA) approach. In general, the results suggest that DP-ERGM preserves the original information significantly better than two other approaches in network structural statistics and inference for ERGMs and latent space models. Furthermore, DP-ERGM satisfies node DP through modeling the global network structure with ERGM, a stronger notion of privacy than the edge DP under which DWRR and SCEA operate.

graph synthesis↗

Fast Track Reservoir Modeling of Shale Formations in the Appalachian Basin. Application to Lower Huron Shale in Eastern Kentucky

In this paper a fast track reservoir modeling and analysis of the Lower Huron Shale in Eastern Kentucky is presented. Unlike conventional reservoir simulation and modeling which is a bottom up approach (geo-cellular model to history matching) this new approach starts by attempting to build a reservoir realization from well production history (Top to Bottom), augmented by core, well-log, well-test and seismic data in order to increase accuracy. This approach requires creation of a large spatial-temporal database that is efficiently handled with state of the art Artificial Intelligence and Data Mining techniques (AI & DM), and therefore it represents an elegant integration of reservoir engineering techniques with Artificial Intelligence and Data Mining. Advantages of this new technique are a) ease of development, b) limited data requirement (as compared to reservoir simulation), and c) speed of analysis. All of the 77 wells used in this study are completed in the Lower Huron Shale and are a part of the Big Sandy Gas field in Eastern Kentucky. Most of the wells have production profiles for more than twenty years. Porosity and thickness data was acquired from the available well logs, while permeability, natural fracture network properties, and fracture aperture data was acquired through a single well history matching process that uses the FRACGEN/NFFLOW simulator package. This technology, known as Top-Down Intelligent Reservoir Modeling, starts with performing conventional reservoir engineering analysis on individual wells such as decline curve analysis and volumetric reserves estimation. Statistical techniques along with information generated from the reservoir engineering analysis contribute to an extensive spatio-temporal database of reservoir behavior. The database is used to develop a cohesive model of the field using fuzzy pattern recognition or similar techniques. The reservoir model is calibrated (history matched) with production history from the most recently drilled wells. The calibrated model is then further used for field development strategies to improve and enhance gas recovery.

03 NATURAL GAS↗

Data-Informed Synthetic Networks of Water Distribution Systems for Resilience Analysis in Puerto Rico

The increasing potential of infrastructure disruptions calls for high-quality infrastructure models to be used in resilience analysis and decision making. Unfortunately, many utilities and communities do not have access to accurate and detailed models due to a lack of data and resources. Furthermore, security restrictions on sharing infrastructure models present roadblocks to research, analysis, and decision making. Recent advances in the development of synthetic water distribution models provide a potential solution to this problem. There is an opportunity to improve these methods by leveraging incomplete pipe datasets to aid synthetic network generation. To address this gap, we developed a methodology for synthetic network generation that incorporates partial pipe data using a modification of the minimum cost flow algorithm for network generation and pipe sizing. This methodology demonstrates how partial pipe data can be leveraged to improve site-specific synthetic network generation. For the study area of Mayagüez, Puerto Rico, a synthetic model generated using 50% of real pipe data matches the pressure of the validation system with an average error of 23.5 m of head, which improves upon the average error of 31.6 m of head produced by a synthetic model generated using no data of the real pipes. Additionally, synthetic networks are shown to replicate the pressure response under a disruption scenario of the validation network, suggesting potential use in resilience analysis.

resilience analysis↗