Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Fort Benning Indianhead Townhome Renovations

The NAHB Research Center partnered with production builder Winchester/Camberley Homes to build a DOE Building America New Construction Test House (NCTH). This single family, detached house, located in the mixed-humid climate zone of Silver Spring, MD, was completed in June 2011. The primary goal for this house was to improve energy efficiency by 30% over the Building America B10 benchmark by developing and implementing an optimized energy solutions package design that could be cost effectively and reliably constructed on a production basis using quality management practices. The intent of this report is to outline the features of this house, discuss the implementation of the energy efficient design, and report on short-term testing results. During the interactive design process of this project, numerous iterations of the framing, air sealing, insulation, and space conditioning systems were evaluated for energy performance, cost, and practical implementation. The final design featured numerous advanced framing techniques, high levels of insulation, and the HVAC system entirely within conditioned space. Short-term testing confirmed a very tight thermal envelope and efficient and effective heating and cooling. In addition, relevant heating, cooling, humidity, energy, and wall cavity moisture data will be collected and presented in a future long-term report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured Cooling Performance and Potential for Buried Duct Condensation in a 1991 Central Florida Retrofit Home

FSEC conducted energy performance monitoring of two existing residences in Central Florida that were undergoing various retrofits. These homes were occupied by FSEC researchers and were fully instrumented to provide detailed energy, temperature, and humidity measurements. The data provided feedback about the performance of two levels of retrofit in two types of homes in a hot-humid climate. This report covers a moderate-level retrofit and includes two years of pre-retrofit data to characterize the impact of improvements. The other home is a 'deep energy retrofit' (detailed in a separate report) that has performed at near zero energy with a photovoltaic (PV) system and extensive envelope improvements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured Whole-House Performance of TaC Studios Test Home

As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA, in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.

(team name)↗

Poly(p-Phenylene Sulfonic Acids). PEMs with frozen-in free volume

Early work with rigid rod aromatic polyelectrolytes implied that steric hindrance in packing of the rigid rods left unoccupied volumes that could absorb and hold water molecules strongly. We called this “frozen in free volume). It is illustrated and contrasted with the packing of flexible backbone polyelectrolytes (Reference 5 of this report). This was quantified for poly(biphenylene disulfonic acid) (PBDSA) and poly(phenylene disulfonic acid) (PPDSA). We found that PPDSA held three water molecules per acid group down to 11% relative humidity (RH) and had very high conductivity even at these low RHs. (Reference 1 of report.) The frozen-in free volume was calculated to be equivalent to a λ of 3.5. The work reported below concentrated on studying these polymers and their copolymers with biphenylene disulfonic acid. As expected, the polyelectrolytes are water soluble. Several approaches towards making water stable films were studied. Grafting alkyl benzene substituents on sulfonic acid groups had worked for PBPDSA (1) so it was tried with PPDSA and a 20%/80% copolymer of BPDSA and PDSA (B20P80). T-butyl, n-octyl and n-dodecyl benzene were grafted. Good films could be made. Water absorption and conductivity were studied as a function of RH and temperature (Reference 2). When less than 20% of the sulfonic acid groups were grafted, conductivity was much higher than that of Nafion NR212 at all RHs. At low graft levels, conductivity was ten times higher. Mechanical properties and swelling were acceptable below 90% RH. However, all the films were unstable in water and slowly disintegrated. The proposed explanation was that the molecules formed nano-aggregates in solution held together by hydrophobic bonding. Their cast films disintegrated when placed in water since hydrophobic bonding between the nano-aggregates was poor. We then shifted to crosslinking as a method to produce water stable films (References 3 and 4). Biphenyl could easily be reacted with the polymer, generating biphenyl sulfone grafts. Films were cast and then crosslinked by heating to 210°C for at least one hour. There was no loss of acid groups even after heating at 225°C for two hours. PPDSA and B20P80 polymers were grafted and crosslinked. Conductivity and water absorption were measured on polymers with grafting degrees from 3 to 16%. As before they all had much higher conductivity than Nafion NR212. One sample was tested as a fuel cell membrane. Unfortunately it tore; the tear was mended with a 3M ionomer. There was some hydrogen leakage. However, the current at a given voltage was about 95% that of a Nafion NR212 membrane over the whole useful range. Considering that this was the first test for such a system, this is remarkable performance. A mechanically better membrane was tested at the end of the grant period. This did not have tears or micro cracks (Reference 5). Testing confirmed earlier data (Sergio Granados-Focil, Ph. D. Thesis, CWRU. 2006) that such very polar membranes were excellent barriers to hydrogen diffusion. Standard measurements showed no hydrogen leakage. This was confirmed by open circuit voltage measurements. They were higher than those of the Nafion NR212 cells. Again the single cell performance was about 95% that of the Nafion SR212 cell over the whole range. These films show great promise. They are very stable and perform very well at very low humidity. They should be able to outperform the present cells with relatively little further development. A second project is reported fully in the final report since it was not published. Its goal was to make membranes with high conductivity and good mechanical strength that would have a constant volume at all RHs. We made large planar 2-D polymers containing 1.5 nm holes lined with sulfonic acid groups. These should hold water very strongly. The largest made was calculated to have a number average diameter of 29 nm. It was expected that when they were cast, they would aggregate and create channels for proton conduction. However, they were so large that they aggregated in solution during preparation. Measurements showed that the aggregates developed long channels. This was demonstrated and is reported. Unfortunately, the aggregates could not be cast with the channels perpendicular to the film plane. If methods are developed to keep the molecules in solution until they are cast, their planes should be parallel and the channels perpendicular to the film direction. They could be very interesting and perhaps important materials.

25 ENERGY STORAGE↗

Interpolated Sounding and Gridded Sounding Value-Added Products

Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25 and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.The INTERPOLATEDSONDE VAP, a continuous time-height grid of relative humidity-corrected sounding data, is intended to provide input to higher-order products, such as the Merged Soundings (MERGESONDE; Troyan 2012) VAP, which extends INTERPOLATEDSONDE by incorporating model data. The INTERPOLATEDSONDE VAP also is used to correct gaseous attenuation of radar reflectivity in products such as the KAZRCOR VAP.

54 ENVIRONMENTAL SCIENCES↗

Measured Whole-House Performance of TaC Studios Test Home

As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach topotential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaCStudios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this homewas evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored todetermine their impact on overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Marine ARM GPCI Investigation of Clouds Psychrometer Field Campaign Report

One of the most critical measurements in the suite of meteorological measurements used for the calculation of evaporation and latent heat flux is the relative humidity (RH). In order to achieve an overall net flux uncertainty < 10 W/m 2 (Bradley and Fairall, 2006), the RH must be accurate to < 2 %RH. Anyone experienced in shipboard meteorological measurements will recognize that this is a tough specification. During the U.S. Department of Energy (DOE) Marine Atmospheric Radiation Measurement (ARM) Climate Research Facility Global Energy and Water Experiment (GEWEX) Cloud System Study (GCSS) Pacific Cross-Section Intercomparison (GPCI) Investigation of Clouds (MAGIC) experiment, the meteorological package used three different RH sensors. We found approximately 3-4 % differences between units. To arbitrate the differences and to track calibration drift over the months of exposure, we used a precision psychrometer. The Assmann Psychrometer, Model 430101 is a classic, mercury-in-glass instrument that gives a precise measure of the wet and dry bulb temperatures from which atmospheric humidity and RH are computed. On a regular basis, typically after each balloon launch, a technician took the psychrometer to an exposed location on the bridge roof. That was just below the instruments on the mast and high enough into the mixed layer that the difference is negligible.

54 ENVIRONMENTAL SCIENCES↗

Fuel Cell Membrane Electrode Assemblies with Ultra-Low Pt Nanofiber Electrodes (Final Report)

H 2 /air fuel cell membrane-electrode-assemblies (MEAs) were fabricated with electrospun particle/polymer nanofiber mat cathodes (0.1 mg Pt /cm 2 or 0.2 mg Pt /cm 2 Pt/C, PtCo/C or PtNi/C) and anodes (0.1 mg/cm 2 Pt/C), where the binder was a mixture of acid-form perfluorosulfonic acid ionomer (e.g., Nafion™) and poly(acrylic acid) (PAA) carrier polymer or sodium-form PFSA with a carrier polymer of either PAA or polyethylene oxide (PEO). For the latter two cases, the water-soluble carrier was removed from the fibers after electrospinning. MEAs with Pt/C anode/cathode catalyst loadings of 0.1 mg Pt /cm2 each, an 1100 EW PFSA binder (Nafion™ dispersion), and a Nafion 211 membrane produced high power at both high and low relative humidity (RH) conditions, e.g., a maximum power density of 919 mW/cm 2 at 100% RH and 832 mW/cm 2 at 40% RH for a test at 80 °C and 200 kPa abs . The high power at low RH was attributed to nm-size pores within the fibers that trap water via capillary condensation thus maintaining a high proton conductivity of the PFSA binder in the cathode and especially the anode while minimizing/eliminating ionic isolation of catalyst particles in low water content, poorly conductive binder. At the same time, micro-porosity between fibers in the cathode allows for fast removal of electrogenerated water, thus minimizing cathode flooding. Nanofiber MEAs with Pt alloy catalyst cathodes also performed well, where a fibrous PtCo/C catalyst cathode at a loading of 0.1 mg/cm 2 produced 20% more power than a conventional powder cathode MEA, e.g., a maximum power density of 1,045 mW/cm 2 vs. 869 mW/cm 2 at 80 °C, 100% RH, and 200 kPa abs , and a PtNi/C fiber cathode MEAs prepared with Na+-form Nafion + PEO generated a maximum power of 820 mW/cm 2 at 40% RH. Fiber electrode MEAs with a neat Nafion binder (prepared from Na+-form Nafion + PEO or PAA) where the cathode Pt loading was ~0.1 mg/cm 2 exhibited a 25% loss in maximum power at 30,000 metal dissolution cycles, as compared to a 12% loss when the cathode binder was H+-form Nafion + PAA. The performance of a fiber mat electrode MEA with Pt/C catalyst (0.2 mg/cm 2 cathode loading and 0.1 mg/cm 2 anode loading) was excellent. At 80 oC and 200 kPa abs , the maximum power density was 1104 mW/cm 2 . The maximum power was independent of feed gas humidity for 40 < RH < 100%. The power loss after a metal dissolution AST (30,000 voltage cycles) was only 13%.

08 HYDROGEN↗

Airborne Aerosol in Situ Measurements during TCAP: A Closure Study of Total Scattering

We present here a framework for calculating the total scattering of both non-absorbing and absorbing aerosol at ambient conditions from aircraft data. The synergistically employed aircraft data involve aerosol microphysical, chemical, and optical components and ambient relative humidity measurements. Our framework is developed emphasizing the explicit use of the complementary chemical composition data for estimating the complex refractive index (RI) of particles, and thus obtaining improved ambient size spectra derived from Optical Particle Counter (OPC) measurements. The feasibility of our framework for improved calculations of total aerosol scattering is demonstrated for different ambient conditions with a wide range of relative humidities (from 5 to 80%) using three types of data collected by the U.S. Department of Energy (DOE) G-1 aircraft during the recent Two-Column Aerosol Project (TCAP). Namely, these three types of data employed are: (1) size distributions measured by an Ultra High Sensitivity Aerosol Spectrometer (UHSAS; 0.06-1 µm), a Passive Cavity Aerosol Spectrometer (PCASP; 0.1-3 µm) and a Cloud and Aerosol Spectrometer (CAS; 0.6- >10 µm), (2) chemical composition data measured by an Aerosol Mass Spectrometer (AMS; 0.06-0.6 µm) and a Single Particle Soot Photometer (SP2; 0.06-0.6 µm), and (3) the dry total scattering coefficient measured by a TSI integrating nephelometer at three wavelengths (0.45, 0.55, 0.7 µm) and scattering enhancement factor measured with a humidification system at three RHs (near 45%, 65% and 90%) at a single wavelength (0.525 µm). We demonstrate that good agreement (~10% on average) between the observed and calculated scattering at these three wavelengths can be obtained using the best available chemical composition data for the RI-based correction of the OPC-derived size spectra. We also demonstrate that ignoring the RI-based correction and using non-representative RI values can cause a substantial underestimation (~40% on average) and overestimation (~35% on average) of the calculated total scattering, respectively.

14 SOLAR ENERGY↗

Meteodrone data

The University of Nebraska-Lincoln (UNL) Meteodrone (model SSE MM-641) is a small (1.1 kg GTOW, ~40 cm across) hexcopter UAS manufactured by Meteomatics. Maximum endurance is approximately 30 min and estimated maximum operating altitude of 1500 m. Profiles can be executed at ascent/descent rates up to 10 m/s. The Meteodrone is capable of measuring temperature, relative humidity, wind velocity and GPS position time-stamped with GPS time. Temperature and dual relative humidity sensors are shielded from solar exposure by a housing with a vertically oriented air intake and hoirizontal exhaust. Sensor aspiration is driven by rotorwash across the horizontal exhaust. In its current configuration data are recorded only when executing vertical profiles. Attitude and position are updated at a data rate of 20 Hz while meteorological observations are updated at 10 Hz.

54 ENVIRONMENTAL SCIENCES↗

Trace Gases, Meteorological Parameters, and GPS data for TRACER-MAP

This dataset includes trace gas, meteorological, and GPS measurements made on Mobile Air Quality Laboratory 2 (MAQL2) for the TRACER-MAP sampling campaign. Trace gas measurements include nitric oxide (NO), nitrogen dioxide (NO2), reactive nitrogen compounds (NOy), ozone (O3), sulfur dioxide (SO2), and carbon monoxide (CO). All trace gases are in units of ppbv, excluding CO which is in ppmv. The dataset also includes the photolysis rate of NO2 (jNO2), latitude and longitude, wind speed (WS), wind direction (WD), ambient relative humidity (RH), ambient pressure (press), and ambient temperature (temp). Units for trace gases are in parts per billion (ppbv), latitude and longitude are in decimal degrees (dd), jNO2 is in per second (per sec), pressure is in millibar (mbar), relative humidity is in percent, the temperature is in degrees C, wind direction is in degrees, and wind speed is in meters per second. All data is 5 minutes averaged.

54 ENVIRONMENTAL SCIENCES↗

CRGTBSO3 TBS Ozone Data

The Tethered Balloon System (TBS) operated for two weeks during a summer IOP of the CoURAGE campaign. This dataset includes data collected from an En-Sci electrochemical cell (ECC) ozonesonde on the TBS. The ozonesonde was connected to an iMet-4RSB radiosonde, and the overall data collected included ozone, relative humidity, temperature, and altitude. The data from the iMet is the same as that found in the TBSMERGED data product. The TBS also had another instrument (iMet XQ2) that collected meteorological data, which may have more accurate relative humidity (RH) data. This ozonesonde data set is intended to complement the TBSMERGED data product, the CRGTBSO3 surface ozone measurements, and the CoURAGE SWARM ozone lidar (TOLNet) measurements from other locations.

Atmospheric relative humidity↗

G189A modelling of Space Station Freedom's ECLSS

This paper contains a review of the requirements and design of the Environmental Control and Life Support System (ECLSS) for Space Station Freedom; a review of the G189A ECLSS computer program model developed at Boeing for the complete configuration of pressurized elements or volumes; and some significant computed results from this model showing transient performance for subsystems responsible for Temperature and Humidity Control,. Atmosphere Control and Supply, Air Revitalization, and Water Recovery and Management. The computed results presented here are important in assessing the capabilities of the ECLSS equipment in maintaining acceptable levels of temperature, humidity, 02, N2 and (2% in the occupied volumes during crew changeout events. These events involve up to four extra crew members from the Orbiter being located temporarily in the Space Station modules in addition to the normal contingent of four crew members. These additional crew members impose additional demands on the ECLSS equipment, in order to control the levels of the aforementioned quantities. Satisfactory control of all of these quantities was achieved. The maximum computed pp C02 was in the acceptable degraded performance regime. This level is higher than the 3.00 mm Hg upper limit for normal conditions

Environmental Control and Life Support Systems (EC↗

Water cycles in closed ecological systems: effects of atmospheric pressure

In bioregenerative life support systems that use plants to generate food and oxygen, the largest mass flux between the plants and their surrounding environment will be water. This water cycle is a consequence of the continuous change of state (evaporation-condensation) from liquid to gas through the process of transpiration and the need to transfer heat (cool) and dehumidify the plant growth chamber. Evapotranspiration rates for full plant canopies can range from ~1 to 10 L m-2 d-1 (~1 to 10 mm m-2 d-1), with the rates depending primarily on the vapor pressure deficit (VPD) between the leaves and the air inside the plant growth chamber. VPD in turn is dependent on the air temperature, leaf temperature, and current value of relative humidity (RH). Concepts for developing closed plant growth systems, such as greenhouses for Mars, have been discussed for many years and the feasibility of such systems will depend on the overall system costs and reliability. One approach for reducing system costs would be to reduce the operating pressure within the greenhouse to reduce structural mass and gas leakage. But managing plant growth environments at low pressures (e.g., controlling humidity and heat exchange) may be difficult, and the effects of low-pressure environments on plant growth and system water cycling need further study. We present experimental evidence to show that water saturation pressures in air under isothermal conditions are only slightly affected by total pressure, but the overall water flux from evaporating surfaces can increase as pressure decreases. Mathematical models describing these observations are presented, along with discussion of the importance for considering "water cycles" in closed bioregenerative life support systems.

NASA Center KSC↗

Control of matric water potential by temperature differential

A method for controlling relative humidity based on temperature differentials, rather than on salt solutions, is described. This method has the following advantages: (1) it does not exhibit the anomalous CO2 solution effects that we have found to occur with salt solutions; (2) humidity is continuously adjustable without sample removal; (3) circulation of the atmosphere results in short equilibration times.

NASA Discipline Exobiology↗

Hydrotropism and its interaction with gravitropism in maize roots

We have partially characterized root hydrotropism and its interaction with gravitropism in maize (Zea mays L.). Roots of Golden Cross Bantam 70, which require light for orthogravitropism, showed positive hydrotropism; bending upward when placed horizontally below a hydrostimulant (moist cheesecloth) in 85% relative humidity (RH) and in total darkness. However, the light-exposed roots of Golden Cross Bantam 70 or roots of a normal maize cultivar, Burpee Snow Cross, showed positive gravitropism under the same conditions; bending downward when placed horizontally below the hydrostimulant in 85% RH. Light-exposed roots of Golden Cross Bantam 70 placed at 70 degrees below the horizontal plane responded positively hydrotropically, but gravitropism overcame the hydrotropism when the roots were placed at 45 degrees below the horizontal. Roots placed vertically with the tip down in 85% RH bent to the side toward the hydrostimulant in both cultivars, and light conditions did not affect the response. Such vertical roots did not respond when the humidity was maintained near saturation. These results suggest that hydrotropic and gravitropic responses interact with one another depending on the intensity of one or both factors. Removal of the approximately 1.5 millimeter root tip blocked both hydrotropic and gravitropic responses in the two cultivars. However, removal of visible root tip mucilage did not affect hydrotropism or gravitropism in either cultivar.

NASA Program Space Biology↗

Monitoring space shuttle air quality using the Jet Propulsion Laboratory electronic nose

A miniature electronic nose (ENose) has been designed and built at the Jet Propulsion Laboratory (JPL), Pasadena, CA, and was designed to detect, identify, and quantify ten common contaminants and relative humidity changes. The sensing array includes 32 sensing films made from polymer carbon-black composites. Event identification and quantification were done using the Levenberg-Marquart nonlinear least squares method. After successful ground training, this ENose was used in a demonstration experiment aboard STS-95 (October-November, 1998), in which the ENose was operated continuously for six days and recorded the sensors' response to the air in the mid-deck. Air samples were collected daily and analyzed independently after the flight. Changes in shuttle-cabin humidity were detected and quantified by the JPL ENose; neither the ENose nor the air samples detected any of the contaminants on the target list. The device is microgravity insensitive.

manned↗

Water cycle and its management for plant habitats at reduced pressures

Experimental and mathematical models were developed for describing and testing temperature and humidity parameters for plant production in bioregenerative life support systems. A factor was included for analyzing systems operating at low (10-101.3 kPa) pressure to reduce gas leakage and structural mass (e.g., inflatable greenhouses for space application). The expected close relationship between temperature and relative humidity was observed, along with the importance of heat exchanger coil temperature and air circulation rate. The presence of plants in closed habitats results in increased water flux through the system. Changes in pressure affect gas diffusion rates and surface boundary layers, and change convective transfer capabilities and water evaporation rates. A consistent observation from studies with plants at reduced pressures is increased evapotranspiration rates, even at constant vapor pressure deficits. This suggests that plant water status is a critical factor for managing low-pressure production systems. The approach suggested should help space mission planners design artificial environments in closed habitats.

NASA Center KSC↗