Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Validation of Minimum Display Requirements for a UAS Detect and Avoid System

The full integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS), a prerequisite for enabling a broad range of public and commercial UAS operations, presents several technical challenges to UAS developers, operators and regulators. A primary barrier is the inability for UAS pilots (situated at a ground control station, or GCS) to comply with Title 14 Code of Federal Regulations sections 91.111 and 91.113, which require pilots to see and avoid other aircraft in order to maintain well clear. The present study is the final in a series of human-in-the-loop experiments designed to explore and test the various display and alerting requirements being incorporated into the minimum operational performance standards (MOPS) for a UAS-specific detect and avoid system that would replace the see and avoid function required of manned aircraft. Two display configurations were tested - an integrated display and a standalone display - and their impact on pilot response times and ability to maintain DAA well clear were compared. Results indicated that the current draft of the MOPS result in high-level performance and did not meaningfully differ by display configuration.

unmanned aircraft systems↗

Metabolites of Tobacco- and E-Cigarette-Related Nitrosamines Can Drive Cu 2+ -Mediated DNA Oxidation

Nitrosamine metabolites resulting from cigarette smoking and E-cigarette (E-cig) vaping cause DNA damage that can lead to genotoxicity. While DNA adducts of metabolites of nitrosamines 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) and N-nitrosonornicotine (NNN) are well-known tobacco-related cancer biomarkers, only a few studies implicate NNN and NNK in DNA oxidation in humans. NNK and NNN were found in the urine of E-cigarette users who never smoked cigarettes. This paper proposes the first chemical pathways of DNA oxidation driven by NNK and NNN metabolites in redox reactions with Cu 2+ and NADPH leading to reactive oxygen species (ROS). A microfluidic array with thin films of DNA and metabolic enzymes that make metabolites of NNN and NNK in the presence of Cu 2+ and NADPH was used to estimate relative rates of DNA oxidation. Detection by electrochemiluminescence (ECL) employed a new ECL dye [Os(tpy-benz-COOH) 2 ] 2+ that is selective for and sensitive to the primary DNA oxidation product 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) in DNA. Enzyme–DNA films on magnetic beads were used to produce nitrosamine metabolites that enter ROS-forming redox cycles with Cu 2+ and NADPH, and liquid chromatography–mass spectrometry (LC–MS) was used to quantify 8-oxodG and identify metabolites. ROS were detected by optical sensors. Metabolites of NNK and NNN + Cu 2+ + NADPH generated relatively high rates of DNA oxidation. Lung is the exposure route in smoking and vaping, human lung tissue contains Cu 2+ and NADPH, and lung microsomal enzymes gave the highest rates of DNA oxidation in this study. Furthermore, E-cigarette vapor contains 6-fold more copper than that in cigarette smoke, which could exacerbate DNA oxidation.

59 BASIC BIOLOGICAL SCIENCES↗

Direct detection of SERCA calcium transport and small-molecule inhibition in giant unilamellar vesicles

We have developed a charge-mediated fusion method to reconstitute the sarco/endoplasmic reticulum Ca{sup 2+}-ATPase (SERCA) in giant unilamellar vesicles (GUV). Intracellular Ca{sup 2+} transport by SERCA controls key processes in human cells such as proliferation, signaling, and contraction. Small-molecule effectors of SERCA are urgently needed as therapeutics for Ca{sup 2+} dysregulation in human diseases including cancer, diabetes, and heart failure. Here we report the development of a method for efficiently reconstituting SERCA in GUV, and we describe a streamlined protocol based on optimized parameters (e.g., lipid components, SERCA preparation, and activity assay requirements). ATP-dependent Ca{sup 2+} transport by SERCA in single GUV was detected directly using confocal fluorescence microscopy with the Ca{sup 2+} indicator Fluo-5F. The GUV reconstitution system was validated for functional screening of Ca{sup 2+} transport using thapsigargin (TG), a small-molecule inhibitor of SERCA currently in clinical trials as a prostate cancer prodrug. The GUV system overcomes the problem of inhibitory Ca{sup 2+} accumulation for SERCA in native and reconstituted small unilamellar vesicles (SUV). We propose that charge-mediated fusion provides a widely-applicable method for GUV reconstitution of clinically-important membrane transport proteins. We conclude that GUV reconstitution is a technological advancement for evaluating small-molecule effectors of SERCA.

60 APPLIED LIFE SCIENCES↗

Detection of genotoxic and non-genotoxic carcinogens in Xpc{sup −/−}p53{sup +/−} mice

An accurate assessment of the carcinogenic potential of chemicals and pharmaceutical drugs is essential to protect humans and the environment. Therefore, substances are extensively tested before they are marketed to the public. Currently, the rodent two-year bioassay is still routinely used to assess the carcinogenic potential of substances. However, over time it has become clear that this assay yields false positive results and also has several economic and ethical drawbacks including the use of large numbers of animals, the long duration, and the high cost. The need for a suitable alternative assay is therefore high. Previously, we have proposed the Xpa*p53 mouse model as a very suitable alternative to the two-year bioassay. We now show that the Xpc*p53 mouse model preserves all the beneficial traits of the Xpa*p53 model for sub-chronic carcinogen identification and can identify both genotoxic and non-genotoxic carcinogens. Moreover, Xpc*p53 mice appear to be more responsive than Xpa*p53 mice towards several genotoxic and non-genotoxic carcinogens. Furthermore, Xpc*p53 mice are far less sensitive than Xpa*p53 mice for the toxic activity of DNA damaging agents and as such clearly respond in a similar way as wild type mice do. These advantageous traits of the Xpc*p53 model make it a better alternative for in vivo carcinogen testing than Xpa*p53. This pilot study suggests that Xpc*p53 mice are suited for routine sub-chronic testing of both genotoxic and non-genotoxic carcinogens and as such represent a suitable alternative to possibly replace the murine life time cancer bioassay. Highlights: ► The Xpc*p53 mouse model is able to identify genotoxic and non-genotoxic carcinogens. ► Time, animals and cost can be significantly reduced compared to the 2-year bioassay. ► Xpc*p53 mice are more advantageous for carcinogen identification than Xpa*p53 mice. ► Xpc*p53 mice exhibit a wild type response upon exposure to genotoxicants.

60 APPLIED LIFE SCIENCES↗

Surfactant-assisted one-pot sample preparation for label-free single-cell proteomics

Large numbers of cells are generally required for quantitative global proteome profiling due to surface adsorption losses associated with sample processing. Such bulk measurement obscures important cell-to-cell variability (cell heterogeneity) and makes proteomic profiling impossible for rare cell populations (e.g., circulating tumor cells (CTCs)). Here we report a surfactant-assisted one-pot sample preparation coupled with mass spectrometry (MS) method termed SOP-MS for label-free global single-cell proteomics. SOP-MS capitalizes on the combination of a MS-compatible nonionic surfactant, n-Dodecyl-β-D-maltoside, and hydrophobic surface-based low-bind tubes or multi-well plates for ‘all-in-one’ one-pot sample preparation. This ‘all-in-one’ method including elimination of all sample transfer steps maximally reduces surface adsorption losses for effective processing of single cells, thus improving detection sensitivity for single-cell proteomics. This method allows convenient label-free quantification of hundreds of proteins from single human cells and ~1200 proteins from small tissue sections (close to ~20 cells). When applied to a patient CTC-derived xenograft (PCDX) model at the single-cell resolution, SOP-MS can reveal distinct protein signatures between primary tumor cells and early metastatic lung cells, which are related to the selection pressure of anti-tumor immunity during breast cancer metastasis. The approach paves the way for routine, precise, quantitative single-cell proteomics.

36 MATERIALS SCIENCE↗

Multi-Target Camera Tracking, Hand-off and Display LDRD 158819 Final Report

Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn’t lead to more alarms, more monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identify individual moving targets from the background imagery, and then display the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.

47 OTHER INSTRUMENTATION↗

Automated anomaly detection for Orbiter High Temperature Reusable Surface Insulation

The description, analysis, and experimental results of a method for identifying possible defects on High Temperature Reusable Surface Insulation (HRSI) of the Orbiter Thermal Protection System (TPS) is presented. Currently, a visual postflight inspection of Orbiter TPS is conducted to detect and classify defects as part of the Orbiter maintenance flow. The objective of the method is to automate the detection of defects by identifying anomalies between preflight and postflight images of TPS components. The initial version is intended to detect and label gross (greater than 0.1 inches in the smallest dimension) anomalies on HRSI components for subsequent classification by a human inspector. The approach is a modified Golden Template technique where the preflight image of a tile serves as the template against which the postflight image of the tile is compared. Candidate anomalies are selected as a result of the comparison and processed to identify true anomalies. The processing methods are developed and discussed, and the results of testing on actual and simulated tile images are presented. Solutions to the problems of brightness and spatial normalization, timely execution, and minimization of false positives are also discussed.

Cooper, Eric G.↗

Automatic Inspection of Aircraft Using Open-Architecture Robotic Platforms

Aging aircraft structures and composite materials are requiring rapid inspection of large areas. Removal from the aircraft for NDE at an inspection facility is not economical as compared to field inspection. Detection and characterization of defects are labor intensive, time consuming and when the process is manual the results are subjected to human error. These limitations of NDE created a need for portable, user friendly inspection systems that can rapidly scan large areas of complex structures and locate all the detrimental material conditions. Addressing this need has been an evolutionary process that followed the technology trend, and unique devices were developed to allow rapid field inspection. This development involves multi-disciplinary approaches to integrate NDE, telerobotics, neural networks, advanced materials science, imbedded computing and automated control. These efforts have led to the development of various portable inspection systems and the current trend is towards fully automatic systems that will operate autonomously.

Bar-Cohen, Yoseph↗

Autonomous Rapid Inspection of Aerospace Structures

Aging aircraft structures and composite materials are requiring rapid inspection of large areas. Removal from the aircraft for NDE at an inspection facility is not economical as compared to field inspection. Detection and characterization of defects are labor intensive, time consuming and when the process is manual the result are subjected to human error.

control inspection systems↗

Flight Deck Display Technologies for 4DT and Surface Equivalent Visual Operations

NASA research is focused on flight deck display technologies that may significantly enhance situation awareness, enable new operating concepts, and reduce the potential for incidents/accidents for terminal area and surface operations. The display technologies include surface map, head-up, and head-worn displays; 4DT guidance algorithms; synthetic and enhanced vision technologies; and terminal maneuvering area traffic conflict detection and alerting systems. This work is critical to ensure that the flight deck interface technologies and the role of the human participants can support the full realization of the Next Generation Air Transportation System (NextGen) and its novel operating concepts.

Prinzel, Lawrence J., III↗

The NASA Fireball Network

In the summer of 2008, the NASA Meteoroid Environments Office (MEO) began to establish a video fireball network, based on the following objectives: (1) determine the speed distribution of cm size meteoroids, (2) determine the major sources of cm size meteoroids (showers/sporadic sources), (3) characterize meteor showers (numbers, magnitudes, trajectories, orbits), (4) determine the size at which showers dominate the meteor flux, (5) discriminate between re-entering space debris and meteors, and 6) locate meteorite falls. In order to achieve the above with the limited resources available to the MEO, it was necessary that the network function almost fully autonomously, with very little required from humans in the areas of upkeep or analysis. With this in mind, the camera design and, most importantly, the ASGARD meteor detection software were adopted from the University of Western Ontario's Southern Ontario Meteor Network (SOMN), as NASA has a cooperative agreement with Western's Meteor Physics Group. 15 cameras have been built, and the network now consists of 8 operational cameras, with at least 4 more slated for deployment in calendar year 2013. The goal is to have 15 systems, distributed in two or more groups east of automatic analysis; every morning, this server also automatically generates an email and a web page (http://fireballs.ndc.nasa.gov) containing an automated analysis of the previous night's events. This analysis provides the following for each meteor: UTC date and time, speed, start and end locations (longitude, latitude, altitude), radiant, shower identification, light curve (meteor absolute magnitude as a function of time), photometric mass, orbital elements, and Tisserand parameter. Radiant/orbital plots and various histograms (number versus speed, time, etc) are also produced. After more than four years of operation, over 5,000 multi-station fireballs have been observed, 3 of which potentially dropped meteorites. A database containing data on all these events, including the videos and calibration information, has been developed and is being modified to include data from the SOMN and other camera networks.

Cooke, William J.↗

Automating Hyperspectral Data for Rapid Response in Volcanic Emergencies

In a volcanic emergency, time is of the essence. It is vital to quantify eruption parameters (thermal emission, effusion rate, location of activity) and distribute this information as quickly as possible to decision-makers in order to enable effective evaluation of eruption-related risk and hazard. The goal of this work was to automate and streamline processing of spacecraft hyperspectral data, automate product generation, and automate distribution of products. Visible and Short-Wave Infrared Images of volcanic eruption in Iceland in May 2010." class="caption" align="right">The software rapidly processes hyperspectral data, correcting for incident sunlight where necessary, and atmospheric transmission; detects thermally anomalous pixels; fits data with model black-body thermal emission spectra to determine radiant flux; calculates atmospheric convection thermal removal; and then calculates total heat loss. From these results, an estimation of effusion rate is made. Maps are generated of thermal emission and location (see figure). Products are posted online, and relevant parties notified. Effusion rate data are added to historical record and plotted to identify spikes in activity for persistently active eruptions. The entire process from start to end is autonomous. Future spacecraft, especially those in deep space, can react to detection of transient processes without the need to communicate with Earth, thus increasing science return. Terrestrially, this removes the need for human intervention.

Davies, Ashley G.↗

Label-Free Detection of Cardiac Troponin-I Using Carbon Nanofiber Based Nanoelectrode Arrays

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. A carbon nanofiber (CNF) multiplexed array has been fabricated with 9 sensing pads, each containing 40,000 carbon nanofibers as nanoelectrodes. Here, we report the use of vertically aligned CNF nanoelectrodes for the detection of cardiac Troponin-I for the early diagnosis of myocardial infarction. Antibody, antitroponin, probe immobilization and subsequent binding to human cardiac troponin-I were characterized using electrochemical impedance spectroscopy and cyclic voltammetry techniques. Each step of the modification process resulted in changes in electrical capacitance or resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific antigen. This sensor demonstrates high sensitivity, down to 0.2 ng/mL, and good selectivity making this platform a good candidate for early stage diagnosis of myocardial infarction.

cardiac output↗

Quantification of Trace Chemicals Using Vehicle Cabin Atmosphere Monitor

A system to monitor the concentrations of trace chemicals in cabin atmosphere is one of the most critical components in long-duration human flight missions. The Vehicle Cabin Atmosphere Monitor (VCAM) is a miniature gas chromatograph mass spectrometer system to be used to detect and quantify trace chemicals in the International Space Station. We developed an autonomous computational process to quantify trace chemicals for use in VCAM. The process involves the design of a measured signal quantification scheme, the construction of concentration curves (i.e. the relationship between concentration and ion count measured by VCAM), the decision rule of applying high- or low-gain concentration curves, and the detection of saturation, low-signals, and outliers. When the developed quantification process is applied, the average errors of concentration for most of trace chemicals are found to be between 14% and 66%.

Lee, Seungwon↗

Unmanned Aircraft Systems Minimum Operations Performance Standards End-to-End Verification and Validation (E2-V2) Simulation

As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of "eyes in the sky" due to having no human on-board the aircraft. The current NAS relies on pilot's vigilance and judgement to remain Well Clear (CFR 14 91.113) of other aircraft. RTCA SC-228 has defined DAA Well Clear (DAAWC) to provide a quantified Well Clear volume to allow systems to be designed and measured against. Extended research efforts have been conducted to understand and quantify system requirements needed to support a UAS pilot's ability to remain well clear of other aircraft. The efforts have included developing and testing sensor, algorithm, alerting, and display requirements. More recently, sensor uncertainty and uncertainty mitigation strategies have been evaluated. This paper discusses results and lessons learned from an End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA SC-228's proposed Phase I DAA Minimum Operational Performance Standards (MOPS). NASA Langley Research Center (LaRC) was called upon to develop a system that evaluates a specific set of encounters, in a variety of geometries, with end-to-end DAA functionality including the use of sensor and tracker models, a sensor uncertainty mitigation model, DAA algorithmic guidance in both vertical and horizontal maneuvering, and a pilot model which maneuvers the ownship aircraft to remain well clear from intruder aircraft, having received collective input from the previous modules of the system. LaRC developed a functioning batch simulation and added a sensor/tracker model from the Federal Aviation Administration (FAA) William J. Hughes Technical Center, an in-house developed sensor uncertainty mitigation strategy, and implemented a pilot model similar to one from the Massachusetts Institute of Technology's Lincoln Laboratory (MIT/LL). The resulting simulation provides the following key parameters, among others, to evaluate the effectiveness of the MOPS DAA system: severity of loss of well clear (SLoWC), alert scoring, and number of increasing alerts (alert jitter). The technique, results, and lessons learned from a detailed examination of DAA system performance over specific test vectors and encounter cases during the simulation experiment will be presented in this paper.

Ghatas, Rania W.↗

Unmanned Aircraft Systems Detect and Avoid System: End-to-End Verification and Validation Simulation Study of Minimum Operations Performance Standards for Integrating Unmanned Aircraft into the National Airspace System

As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of "eyes in the sky" due to having no human on-board the aircraft. The technique, results, and lessons learned from a detailed End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA SC-228's proposed Phase I DAA Minimum Operational Performance Standards (MOPS), based on specific test vectors and encounter cases, will be presented in this paper.

Ghatas, Rania W.↗

Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) Project

Over the past 5 years, the UAS integration into the NAS project has worked to reduce technical barriers to integration. A major focus of this work has been in support of RTCA SC-228. This committee has recently published the first UAS integration minimum performance standards (MOPS). This work has spanned detect and avoid (DAA) as well as command and control comm datalinks. I will discuss DAA efforts with focus on the human systems work. I will discuss how automation was discussed and addressed within this context. ICAO stood up a remotely piloted aircraft systems (RPAS) panel in 2014. They have developed an RPAS manual and are now working to revise existing annexes and standards and recommended practices. The Human In The System (HITS) has worked to infuse human factors guidelines into those documents. I will discuss that effort as well as how ICAO has defined and address autonomy. There is a great deal of interest in the control of multiple vehicles by a single operator. The UAS EXCOM Science and Research Panel (SARP) is holding a workshop on this topic in late June. I will discuss research performed on this topic when I worked for the Army and on-going work within the division and a NATO working group on Human-Autonomy Teaming.

Unmanned Aircraft Systems (UAS)↗

The Effects of Severity of Losses of Well Clear on Minimum Operations Performance Standards End-To-End Verification and Validation Simulation Study for Integrating Unmanned Aircraft Systems into the National Airspace System Using Detect and Avoid Systems

As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of “eyes in the sky” due to having no human on-board the aircraft. The technique, results, and lessons learned from a detailed End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA Special Committee(SC)-228’s proposed Phase I DAA Minimum Operational Performance Standards (MOPS), based on specific test vectors and encounter cases, will be presented in this paper.

Ghatas, Rania W.↗