Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high performance parallel computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Integrating a ponderomotive guiding center algorithm into a quasi-static particle-in-cell code based on azimuthal mode decomposition

High fidelity modeling of plasma based acceleration (PBA) requires the use of three dimensional, fully nonlinear, and kinetic descriptions based on the particle-in-cell (PIC) method. In PBA an intense particle beam or laser (driver) propagates through a tenuous plasma whereby it excites a plasma wave wake. Three-dimensional PIC algorithms based on the quasi-static approximation (QSA) have been successfully applied to efficiently model the interaction between relativistic charged particle beams and plasma. In a QSA PIC algorithm, the plasma response to a charged particle beam or laser driver is calculated based on forces from the driver and self-consistent forces from the QSA form of Maxwell's equations. These fields are then used to advance the charged particle beam or laser forward by a large time step. Since the time step is not limited by the regular Courant-Friedrichs-Lewy (CFL) condition that constrains a standard 3D fully electromagnetic PIC code, a 3D QSA PIC code can achieve orders of magnitude speedup in performance. Recently, a new hybrid QSA PIC algorithm that combines another speedup technique known as an azimuthal Fourier decomposition has been proposed and implemented. This hybrid algorithm decomposes the electromagnetic fields, charge and current density into azimuthal harmonics and only the Fourier coefficients need to be updated, which can reduce the algorithmic complexity of a 3D code to that of a 2D code. Modeling the laser-plasma interaction in a full 3D electromagnetic PIC algorithm is very computationally expensive due the enormous disparity of physical scales to be resolved. In the QSA the laser is modeled using the ponderomotive guiding center (PGC) approach. We describe how to implement a PGC algorithm compatible for the QSA PIC algorithms based on the azimuthal mode expansion. Here this algorithm permits time steps orders of magnitude larger than the cell size and it can be asynchronously parallelized. Details on how this is implemented into the QSA PIC code that utilizes an azimuthal mode expansion, QPAD, are also described. Benchmarks and comparisons between a fully 3D explicit PIC code (OSIRIS), as well as a few examples related to laser wakefield acceleration, are presented.

97 MATHEMATICS AND COMPUTING↗

Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inter-Disciplinary Collaboration in Support of the Post-Standby TREAT Mission

Although analysis methods have advanced significantly in the last two decades, high fidelity multi- physics methods for reactors systems have been under development for only a few years and are not presently mature nor deployed. Furthermore, very few methods provide the ability to simulate rapid transients in three dimensions. Data for validation of advanced time-dependent multi- physics is sparse; at TREAT, historical data were not collected for the purpose of validating three-dimensional methods, let alone multi-physics simulations. Existing data continues to be collected to attempt to simulate the behavior of experiments and calibration transients, but it will be insufficient for the complete validation of analysis methods used for TREAT transient simulations. Hence, a 2018 restart will most likely occur without the direct application of advanced modeling and simulation methods. At present, the current INL modeling and simulation team plans to work with TREAT operations staff in performing reactor simulations with MAMMOTH, in parallel with the software packages currently being used in preparation for core restart (e.g., MCNP5, RELAP5, ABAQUS). The TREAT team has also requested specific measurements to be performed during startup testing, currently scheduled to run from February to August of 2018. These startup measurements will be crucial in validating the new analysis methods in preparation for ultimate application for TREAT operations and experiment design. This document describes the collaboration between modeling and simulation staff and restart, operations, instrumentation and experiment development teams to be able to effectively interact and achieve successful validation work during restart testing.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

HIPLZ: Enabling performance portability for exascale systems

While heterogeneous computing has emerged as a dominant trend in current and future High-Performance Computing (HPC) systems, it is also widely recognized that this shift has led to increased software complexity due to a proliferation of programming systems for different heterogeneous processors. One such example is the Heterogeneous-Compute Interface for Portability from AMD (HIP ), which is composed of a C Runtime API and C++ Kernel Language. Many HPC applications will likely use HIP on future exascale systems (e.g., Frontier and El Capitan), but HIP currently only targets AMD and NVIDIA processors. This limitation creates challenges for users who would also like to run their applications on exascale systems based on other architectures (e.g., Aurora, which is based on Intel hardware) that are currently not targeted by HIP . In this paper, we introduce the design and implementation of HIPLZ , a compiler and runtime system that uses the Intel Level Zero API to support HIP on Intel GPU architectures. We discuss the design of HIPLZ , derived from HIPCL (an implementation of HIP on top of OpenCL ), and portability issues that occur from using the Level Zero runtime as a backend. We evaluate our implementation by running several performance benchmarks and mini-apps written in HIP on Intel architectures using HIPLZ . Our results show that this approach provides competitive performance relative to Intel's OpenCL implementations on Intel Gen9 and UHD Graphics 770 GPUs, while providing good coverage of features needed by HPC applications. Overall, this approach is a promising demonstration of enabling performance portability for exascale systems.

97 MATHEMATICS AND COMPUTING↗

SERIIUS-MAGEEP Visiting Scholars Program

Recent studies have assessed closed-loop supercritical carbon dioxide (s-CO 2 ) Brayton cycles to be a higher energy-density system in comparison to equivalent superheated steam Rankine systems. At turbine inlet conditions of 700°C and 20 MPa, a cycle thermal efficiency of ~50% can be achieved. Achieving these high efficiencies will help concentrating solar power (CSP) technologies to become a competitive alternative to current power generation methods. To incorporate an s-CO 2 Brayton power cycle in a solar power tower system, the development of a solar receiver capable of providing an outlet temperature of 700°C (at 20 MPa) is necessary. To satisfy the temperature requirements of an s-CO 2 Brayton cycle with recuperation and recompression, the s-CO 2 must undergo a temperature rise of ~200°C as it flows through the solar receiver. The main objective is to develop an optical-thermal-fluid and structural model to validate a tubular receiver that will receive a heat input ~0.33 MWth from the heliostat field at the National Solar Thermal Test Facility (NSTTF), Albuquerque, NM, USA. We also commenced the development of computational models and testing of air receivers being developed by the Indian Institute of Science (IISc) and the Indian Institute of Technology in Bombay (IIT-B). The helical tubular receiver is expected to counteract the effect of thermal expansion while using a cavity to reduce the radiative and convective losses. Initially, this receiver will be tested for a temperature range of 100-300°C under 1 MPa of pressurized air. The helical air receiver will be exposed to 10kWth to achieve a temperature rise of ~200°C. Preliminary tests to validate the modeling will be performed before the design and construction of a larger scale receiver. Lastly, I focused on the development of a new computational tool that would allow us to perform a nodal creep-fatigue analysis on the receivers and heat exchangers being developed. This tool was developed using MATLAB and is capable of processing the results obtained from ANSYS Fluent and Structural combined, which was limited when using commercial software. The main advantage of this code is that it can be modified to run in parallel making it more affordable and faster compared to commercial codes available. The code is in the process of validation and is currently being compared to nCode Design Life.

25 ENERGY STORAGE↗

Drive-pressure optimization in ramp-wave compression experiments through differential evolution

Ramp-wave dynamic-compression experiments are used to examine quasi-isentropic loading paths in materials. The gradual and continuous increase in pressure created by ramp waves make these types of experiments ideal for studying nonequilibrium material behavior, such as solidification kinetics. In ramp-wave compression experiments, the input drive pressure to the experimental setup may be exerted through one of a number of different mechanisms (e.g., magnetic fields, gas-gun-driven impactors, or high-energy lasers) and is generally required for simulating such experiments. Yet, regardless of the specific mechanism, this drive pressure cannot be measured directly (measurements are generally taken at a location near the back of the experimental setup through a transparent window), leading to an inverse problem where one must determine the drive pressure at the front of the experimental setup (i.e., the input) that corresponds to the particle velocity (the output) measured near the back of the experimental setup. Furthermore, we solve this inverse problem using a heuristic optimization algorithm, known as differential evolution, coupled with a multiphysics, hydrodynamics code that simulates the compression of the experimental setup. By running many rounds of forward simulations of the experimental setup, our optimization process iteratively searches for a drive pressure that is optimized to closely reproduce the experimentally measured particle velocity near the back of the experimental setup. While our optimization methodology requires a significant number of hydrodynamics simulations to be conducted, many of these can be performed in parallel, which greatly reduces the time cost of our methodology. One novel aspect of our method for determining the drive pressure is that it does not require physical modeling of the drive mechanism and can thus be broadly applied to many types of ramp-compression experiments, regardless of the drive mechanism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of Multivariate Data Analysis Techniques for the Portable Isotopic Neutron Spectroscopy system

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical compounds non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS systems have been successfully deployed around the world to identify chemical munitions and containers. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with the probabilistic decision tree (PDT). Gamma-ray peak analyses, however, require knowledge of pre-selected gamma-ray peaks whose energies, intensities, and origins are well studied, and some peaks might be excluded from the decision making processes due to lack of current nuclear data. In contrast, Multivariate Analysis (MVA) treats a whole gamma-ray spectrum as a collection of multiple variables or a pattern. The effectiveness of chemical identification algorithm is determined by the availability of a wide range of data to train an algorithm to identify chemical fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to combine such a database with the principle of multivariate statistics. Therefore, in parallel with the current decision tree algorithm, an MVA-based chemical identification algorithm was developed as an independent verification of the current results. The Principal Component Analysis (PCA) method was adopted to build an MVA-based identification algorithm, using the collected field data to refine and validate the algorithm. A benchmarking study of the MVA-based algorithm’s performance was conducted alongside the current algorithm, with the results presented and discussed in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generic and robust method for automatic segmentation of PET images using an active contour model

Purpose: Although positron emission tomography (PET) images have shown potential to improve the accuracy of targeting in radiation therapy planning and assessment of response to treatment, the boundaries of tumors are not easily distinguishable from surrounding normal tissue owing to the low spatial resolution and inherent noisy characteristics of PET images. The objective of this study is to develop a generic and robust method for automatic delineation of tumor volumes using an active contour model and to evaluate its performance using phantom and clinical studies. Methods: MASAC, a method for automatic segmentation using an active contour model, incorporates the histogram fuzzy C-means clustering, and localized and textural information to constrain the active contour to detect boundaries in an accurate and robust manner. Moreover, the lattice Boltzmann method is used as an alternative approach for solving the level set equation to make it faster and suitable for parallel programming. Twenty simulated phantom studies and 16 clinical studies, including six cases of pharyngolaryngeal squamous cell carcinoma and ten cases of nonsmall cell lung cancer, were included to evaluate its performance. Besides, the proposed method was also compared with the contourlet-based active contour algorithm (CAC) and Schaefer’s thresholding method (ST). The relative volume error (RE), Dice similarity coefficient (DSC), and classification error (CE) metrics were used to analyze the results quantitatively. Results: For the simulated phantom studies (PSs), MASAC and CAC provide similar segmentations of the different lesions, while ST fails to achieve reliable results. For the clinical datasets (2 cases with connected high-uptake regions excluded) (CSs), CAC provides for the lowest mean RE (−8.38% ± 27.49%), while MASAC achieves the best mean DSC (0.71 ± 0.09) and mean CE (53.92% ± 12.65%), respectively. MASAC could reliably quantify different types of lesions assessed in this work with good accuracy, resulting in a mean RE of −13.35% ± 11.87% and −11.15% ± 23.66%, a mean DSC of 0.89 ± 0.05 and 0.71 ± 0.09, and a mean CE of 19.19% ± 7.89% and 53.92% ± 12.65%, for PSs and CSs, respectively. Conclusions: The authors’ results demonstrate that the developed novel PET segmentation algorithm is applicable to various types of lesions in the authors’ study and is capable of producing accurate and consistent target volume delineations, potentially resulting in reduced intraobserver and interobserver variabilities observed when using manual delineation and improved accuracy in treatment planning and outcome evaluation.

60 APPLIED LIFE SCIENCES↗

Extreme-scale stochastic optimization and simulation via learning-enhanced decomposition and parallelization (Final Technical Report)

Stochastic optimization and simulation models ubiquitously arise in designing and operating complex service/engineering systems. They can be extreme in scale due to high-dimensional data and decisions, and can also involve decisions made sequentially in response to newly revealed data, both causing significant computational challenge. The objective of this research is to explore a unified framework that integrates machine learning with discrete optimization and risk-averse modeling, to improve the efficiency of decomposition paradigms for stochastic optimization and simulations at extreme scale. The models we consider represent a broad class of complex decision-making problems, where 0-1 or continuous decisions are made before and/or after knowing multiple sources of uncertainties that could be correlated. We will employ machine learning methods to dynamically decide and prioritize computational procedures, including cut generation, branching, and bounding of the optimal objective. Furthermore, the research will shed new lights on the traditional decomposition algorithms for extreme-scale computing. Deliverables of the research include new modeling and computational methods for advancing the state-of-the-art research in optimization and simulation, bringing many relevant risk-averse, data-driven optimization problems in practice within the range of tractability. Examples include distributed computing server scheduling and sensor deployment for monitoring critical infrastructures. Success in this effort will enable progress in solving multiple extreme-scale problems in the complex system design and operations arising from DoE missions in energy, environment, and national security.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutron and X-ray Detectors

The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors: Improvements in the readout speed and energy resolution of X-ray detectors are essential to enable chemically sensitive microscopies. Advances would make it possible to take images with simultaneous spatial and chemical information. Very high-energy-resolution X-ray detectors: The energy resolution of semiconductor detectors, while suitable for a wide range of applications, is far less than what can be achieved with X-ray optics. A direct detector that could rival the energy resolution of optics could dramatically improve the efficiency of a multitude of experiments, as experiments are often repeated at a number of different energies. Very high-energy-resolution detectors could make these experiments parallel, rather than serial. Low-background, high-spatial-resolution neutron detectors: Low-background detectors would significantly improve experiments that probe excitations (phonons, spin excitations, rotation, and diffusion in polymers and molecular substances, etc.) in condensed matter. Improved spatial resolution would greatly benefit radiography, tomography, phase-contrast imaging, and holography. Improved acquisition and visualization tools: In the past, with the limited variety of slow detectors, it was straightforward to visualize data as it was being acquired (and adjust experimental conditions accordingly) to create a compact data set that the user could easily transport. As detector complexity and data rates explode, this becomes much more challenging. Three goals were identified as important for coping with the growing data volume from high-speed detectors: Facilitate better algorithm development. In particular, algorithms that can minimize the quantity of data stored. Improve community-driven mechanisms to reduce data protocols and enhance quantitative, interactive visualization tools. Develop and distribute community-developed, detector-specific simulation tools. Aim for parallelization to take advantage of high-performance analysis platforms. Improved analysis work flows: Standardize the format of metadata that accompanies detector data and describes the experimental setup and conditions. Develop a standardized user interface and software framework for analysis and data management. The diversity of detector improvements required is necessarily as broad as the range of scientific experimentation at BES facilities. This workshop identified a variety of avenues by which detector R&D can enable enhanced science at BES facilities. The Research Directions listed above will be addressed by focused R&D and detector engineering, both of which require specialized infrastructure and skills. While U.S. leadership in neutron and X-ray detectors lags behind other countries in several areas, significant talent exists across the complex. A forum of technical experts, facilities management, and BES could be a venue to provide further definition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dispersion of Radionuclides and Exposure Assessment in Urban Environments: A Joint CEA and LLNL Report

In the interest of promoting the international exchange of technical expertise, the US Department of Energy’s Office of Emergency Operations (NA-40) and the French Commissariat à l'Energie Atomique et aux énergies alternatives (CEA) requested that the National Atmospheric Release Advisory Center (NARAC) of Lawrence Livermore National Laboratory (LLNL) in Livermore, California host a joint table top exercise with experts in emergency management and atmospheric transport modeling. In this table top exercise, LLNL and CEA compared each other’s flow and dispersion models. The goal of the comparison is to facilitate the exchange of knowledge, capabilities, and practices, and to demonstrate the utility of modeling dispersal at different levels of computational fidelity. Two modeling approaches were examined, a regional scale modeling approach, appropriate for simple terrain and/or very large releases, and an urban scale modeling approach, appropriate for small releases in a city environment. This report is a summary of LLNL and CEA modeling efforts from this exercise. Two different types of LLNL and CEA models were employed in the analysis: urban-scale models (Aeolus CFD at LLNL/NARAC and Parallel- Micro-SWIFT-SPRAY, PMSS, at CEA) for analysis of a 5,000 Ci radiological release and Lagrangian Particle Dispersion Models (LODI at LLNL/NARAC and PSPRAY at CEA) for analysis of a much larger (500,000 Ci) regional radiological release. Two densely-populated urban locations were chosen: Chicago with its high-rise skyline and gridded street network and Paris with its more consistent, lower building height and complex unaligned street network. Each location was considered under early summer daytime and nighttime conditions. Different levels of fidelity were chosen for each scale: (1) lower fidelity mass-consistent diagnostic, intermediate fidelity Navier-Stokes RANS models, and higher fidelity Navier-Stokes LES for urban-scale analysis, and (2) lower-fidelity single-profile meteorology versus higher-fidelity three-dimensional gridded weather forecast for regional-scale analysis. Tradeoffs between computation time and the fidelity of the results are discussed for both scales. LES, for example, requires nearly 100 times more processor time than the mass-consistent diagnostic model or the RANS model, and seems better able to capture flow entrainment behind tall buildings. As anticipated, results obtained by LLNL and CEA at regional scale around Chicago and Paris look very similar in terms of both atmospheric dispersion of the radiological release and total effective dose. Both LLNL and CEA used the same meteorological data, Lagrangian particle dispersion models, and the same dose coefficients. LLNL and CEA urban-scale modeling results show consistent phenomenological behavior and predict similar impacted areas even though the detailed 3D flow patterns differ, particularly for the Chicago cases where differences in vertical entrainment behind tall buildings are particularly notable. Although RANS and LES (LLNL) models incorporate more detailed physics than do mass-consistent diagnostic flow models (CEA), it is not possible to reach definite conclusions about the prediction fidelity of the various models as experimental measurements were not available for comparison. Stronger conclusions about the relative performances of the models involved and evaluation of the tradeoffs involved in model simplification could be made with a systematic benchmarking of urban-scale modeling. This could be the purpose of a future US / French collaborative exercise.

54 ENVIRONMENTAL SCIENCES↗

Performance tuning of CEED software and 1st and 2nd wave apps

The goal of this milestone was the performance tuning of the CEED software, as well as the use and tuning of CEED to accelerate the first and second wave of targeted ECP applications. In this milestone, the CEED team developed optimization techniques and tuned for performance the CEED software to accelerate the first and second wave target ECP applications. Specifically, the focus was on the following: (1) Efficient use of the memory sub-system for managing data motion and interactions among different physics packages and libraries; this included integration of the new developments in a libCEED 0.5 software release; (2) Enhancing the CEED libraries with GPU and AMD GPU support in close interaction with vendors; (3) Optimal data locality and motion, and enhanced scalability and parallelism; this included vendors interactions for improvements in data motion and making strong scaling easier and more efficient; and (4) Continue boosting performance for the first-wave and second-wave of ECP target applications, including ExaSMR, ExaWind, Urban, MARBL, E3SM, and ExaAM. A main part of this milestone was the performance tuning of the CEED first-wave and second-wave ECP applications. This included the ExaSMR application – Coupled Monte Carlo Neutronics and Fluid Flow Simulation of Small Modular Reactors (ORNL), the MARBL application – Next-Gen Multi-physics Simulation Code (LLNL), and the ExaAM ExaConstit – a miniapp for the Transforming Additive Manufacturing through Exascale Simulation applications project (ExaAM), as well as ExaWind, Urban, and E3SM. The artifacts delivered include performance improvements in CEED’s 1st and 2nd wave of applications, and tuned CEED software for various architectures through a number of backends, freely available in the CEED’s repository on GitHub. See the CEED website, http://ceed.exascaleproject.org and the CEED GitHub organization, http://github.com/ceed for more details. In addition to details and results from the above R&D efforts, in this document we are also reporting on other project-wide activities performed in Q4 of FY19 including: CEED’s third annual meeting, MFEM GPU kernels scaling improvements, libCEED 0.5 and NekRS releases, an overview paper covering latest results on a set of bake-off high-order finite element problems (BPs), and other outreach efforts.

97 MATHEMATICS AND COMPUTING↗

Supercomputer-Based Ensemble Docking Drug Discovery Pipeline with Application to Covid-19

In this work, we present a supercomputer-driven pipeline for in silico drug discovery using enhanced sampling molecular dynamics (MD) and ensemble docking. Ensemble docking makes use of MD results by docking compound databases into representative protein binding-site conformations, thus taking into account the dynamic properties of the binding sites. We also describe preliminary results obtained for 24 systems involving eight proteins of the proteome of SARS-CoV-2. The MD involves temperature replica exchange enhanced sampling, making use of massively parallel supercomputing to quickly sample the configurational space of protein drug targets. Using the Summit supercomputer at the Oak Ridge National Laboratory, more than 1 ms of enhanced sampling MD can be generated per day. We have ensemble docked repurposing databases to 10 configurations of each of the 24 SARS-CoV-2 systems using AutoDock Vina. Comparison to experiment demonstrates remarkably high hit rates for the top scoring tranches of compounds identified by our ensemble approach. We also demonstrate that, using Autodock-GPU on Summit, it is possible to perform exhaustive docking of one billion compounds in under 24 h. Finally, we discuss preliminary results and planned improvements to the pipeline, including the use of quantum mechanical (QM), machine learning, and artificial intelligence (AI) methods to cluster MD trajectories and rescore docking poses.

60 APPLIED LIFE SCIENCES↗

Transport Studies and Modeling in PEM Fuel Cells

This project’s aim was to develop fuel cell components (i.e. membranes, gas-diffusion media (GDM), bipolar plates and flow fields) that possess specific properties (i.e. water transport and conductivity). A computational fluid dynamics model was developed to elucidate the effect of certain parameters on these specific properties. Ultimately, the model will be used to determine sensitivity of fuel cell performance to component properties to determine limiting components and to guide research. We have successfully reached our objectives and achieved most of the milestones of this project. We have designed and synthesized a variety of hydrocarbon block polymer membranes with lower equivalent weight, structure, chemistry, phase separation and process conditions. These membranes provide a broad selection with optimized water transport properties. We have also designed and constructed a variety of devices that are capable of accurately measuring the water transport properties (water uptake, water diffusivity and electro-osmatic drag) of these membranes. These transport properties are correlated to the membranes’ structures derived from X-ray and microscopy techniques to determine the structure-property relationship. We successfully integrated hydrocarbon membrane MEAs with a current distribution board (CBD) to study the impact of hydrocarbon membrane on water transport in fuel cells. We have designed and fabricated various GDM with varying substrate, diffusivity and micro-porous layers (MPL) and characterized their pore structure, tortuosity and hydrophobicity. We have derived a universal chart (MacMullin number as function of wet proofing and porosity) that can be used to characterize various GDM. The abovementioned GDMs have been evaluated in operating fuel cells; their performance is correlated to various pore structure, tortuosity and hydrophobicity of the GDM. Unfortunately, determining a universal relationship between the MacMullin number and these properties was not achieved. We have simulated fuel cell performance, current distribution and water distribution at various values of the water uptake, membrane diffusivity, and electro-osmotic drag coefficient (EODC) and compared modeling results with segmented-cell data for both serpentine and parallel flow-fields. We have developed iterations of fuel cell flow fields to achieve specific water transport and thermal management targets. This work demonstrated the importance of membrane diffusivity on fuel cell performance, the necessity of a high membrane diffusion coefficient, and the desirability of a low EODC at low levels of relative humidity.

08 HYDROGEN↗

SU-D-213-05: Design, Evaluation and First Applications of a Off-Site State-Of-The-Art 3D Dosimetry System

Purpose: To design, construct and commission a prototype in-house three dimensional (3D) dose verification system for stereotatic body radiotherapy (SBRT) verification at an off-site partner institution. To investigate the potential of this system to achieve sufficient performance (1mm resolution, 3% noise, within 3% of true dose reading) for SBRT verification. Methods: The system was designed utilizing a parallel ray geometry instigated by precision telecentric lenses and an LED 630nm light source. Using a radiochromic dosimeter, a 3D dosimetric comparison with our gold-standard system and treatment planning software (Eclipse) was done for a four-field box treatment, under gamma passing criteria of 3%/3mm/10% dose threshold. Post off-site installation, deviations in the system’s dose readout performance was assessed by rescanning the four-field box irradiated dosimeter and using line-profiles to compare on-site and off-site mean and noise levels in four distinct dose regions. As a final step, an end-to-end test of the system was completed at the off-site location, including CT-simulation, irradiation of the dosimeter and a 3D dosimetric comparison of the planned (Pinnacle{sup 3}) to delivered dose for a spinal SBRT treatment(12 Gy per fraction). Results: The noise level in the high and medium dose regions of the four field box treatment was relatively 5% pre and post installation. This reflects the reduction in positional uncertainty through the new design. This At 1mm dose voxels, the gamma pass rates(3%,3mm) for our in-house gold standard system and the off-site system were comparable at 95.8% and 93.2% respectively. Conclusion: This work will describe the end-to-end process and results of designing, installing, and commissioning a state-of-the-art 3D dosimetry system created for verification of advanced radiation treatments including spinal radiosurgery.

60 APPLIED LIFE SCIENCES↗

Separate Effects Validation for Subcooled Boiling in CTF

In 2010, the U.S. Department of Energy created its first Energy Innovation Hub, which is focused on developing high-fidelity and high-resolution modeling and simulation (M&S) tools for modeling of light water reactors (LWRs). This hub, the Consortium for Advanced Simulation of LWRs (CASL), has developed an LWR simulation tool called the Virtual Environment for Reactor Applications (VERA). The multi-physics capability of VERA is achieved through the coupling of single-physics codes, including CTF (the CASL version of Coolant Boiling in Rod Arrays— Three Field (COBRA-TF)), Michigan Parallel Characteristics Transport (MPACT), BISON, and Materials Performance and Optimization (MPO) Advanced Model for Boron Analysis (MAMBA). As part of its M&S efforts, CASL has identified various challenge problems, including Crud Induced Power Shift (CIPS), Crud-Induced Localized Corrosion (CILC), Pellet-Cladding Interaction (PCI), and Departure from Nucleate Boiling (DNB). This work addresses CASL milestone L2:VVI.P19.03, which focuses on uncertainty quantification of crud, which is relevant to both CIPS and CILC. This is achieved through an analysis and separate effects validation of the thermal hydraulic phenomenon known as subcooled boiling. As part of this work, various sources of experimental data are examined and compared to different options for empirical modeling of subcooled boiling. Through this analysis, a complete understanding of the underlying models and their implementation details are understood. A subset of these data are incorporated into a separate effects validation study of CTF. The Westinghouse Advanced Loop Tester (WALT) and Rohsenow experiments are modeled, and it is shown that the newly-implemented Gorenflo correlation is more accurate than the existing Chen and Thom correlations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Petaflops router

Disclosed is a method and system for performing operations on at least one input data vector in order to produce at least one output vector to permit easy, scalable and fast programming of a petascale equivalent supercomputer. A PetaFlops Router may comprise one or more PetaFlops Nodes, which may be connected to each other and/or external data provider/consumers via a programmable crossbar switch external to the PetaFlops Node. Each PetaFlops Node has a FPGA and a programmable intra-FPGA crossbar switch that permits input and output variables to be configurably connected to various physical operators contained in the FPGA as desired by a user. This allows a user to specify the instruction set of the system on a per-application basis. Further, the intra-FPGA crossbar switch permits the output of one operation to be delivered as an input to a second operation. By configuring the external crossbar switch, the output of a first operation on a first PetaFlops Node may be used as the input for a second operation on a second PetaFlops Node. An embodiment may provide an ability for the system to recognize and generate pipelined functions. Streaming operators may be connected together at run-time and appropriately staged to allow data to flow through a series of functions. This allows the system to provide high throughput and parallelism when possible. The PetaFlops Router may implement the user desired instructions by appropriately configuring the intra-FPGA crossbar switch on each PetaFlops Node and the external crossbar switch.

97 MATHEMATICS AND COMPUTING↗