Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

A case study of the effects of random errors in rawinsonde data on computations of ageostrophic winds

Data input for the AVE-SESAME I experiment are utilized to describe the effects of random errors in rawinsonde data on the computation of ageostrophic winds. Computer-generated random errors for wind direction and speed and temperature are introduced into the station soundings at 25 mb intervals from which isentropic data sets are created. Except for the isallobaric and the local wind tendency, all winds are computed for Apr. 10, 1979 at 2000 GMT. Divergence fields reveal that the isallobaric and inertial-geostrophic-advective divergences are less affected by rawinsonde random errors than the divergence of the local wind tendency or inertial-advective winds.

Moore, J. T.↗

Optical studies of gamma-ray burst fields, 1: GRB 790329

An optical photometric and proper motion survey of a approximately = 160 sq arcmin region centered on an interplanetary network 41 sq arcmin GRB 790329 error box is presented. No obvious counterparts to the gamma-ray burst were identified. The distribution of stellar colors in the survey region was that expected for the galactic latitude of the burst field. Six stars with significant proper motions were identified. One of these, Gl 397, was found to be a double star. The companion has the color and luminosity of an M4/5 dwarf. We note that associating the gamma-ray burst with the Gl 397 system seems to require energies beyond that seen in the flares of other late-type dwarfs. A small number of galaxies were identified, one of which (object #4), was the bluest object found in the survey (V - I = 0.49).

Harrison, Thomas E.↗

Nonlinear Effects at the Fermilab Recycler e-Cloud Instability

Theoretical analysis of e-cloud instability in the Fermilab Recycler is represented in the paper. The e-cloud in strong magnetic field is treated as a set of immovable snakes each being initiated by some proton bunch. It is shown that the instability arises because of injection errors of the bunches which increase in time and from bunch to bunch along the batch being amplified by the e-cloud electric field. The particular attention is given to nonlinear additions to the cloud field. It is shown that the nonlinearity is the main factor which restricts growth of the bunch amplitude. Possible role of the field free parts of the Recycler id discussed as well. Results of calculations are compared with experimental data demonstrating good correlation.

43 PARTICLE ACCELERATORS↗

Spatiotemporal video-domain high-fidelity simulation and realistic visualization of full-field dynamic responses of structures by a combination of high-spatial-resolution modal model and video motion manipulations

Structures with complex geometries, material properties, and boundary conditions exhibit spatially local dynamic behaviors. A high-spatial-resolution model of the structure is thus required for high-fidelity analysis, assessment, and prediction of the dynamic phenomena of the structure. The traditional approach is to build a highly refined finite element computer model for simulating and analyzing the structural dynamic phenomena based on detailed knowledge and explicit modeling of the structural physics such as geometries, materials properties, and boundary conditions. These physics information of the structure may not be available or accurately modeled in many cases, however. In addition, the simulation on the high-spatial-resolution structural model, with a massive number of degrees of freedom and system parameters, is computationally demanding. Here this study, on a proof-of-principle basis, proposes a novel alternative approach for spatiotemporal video-domain high-fidelity simulation and realistic visualization of full-field structural dynamics by an innovative combination of the fundamentals of structural dynamic modeling and the advanced video motion manipulation techniques. Specifically, a low-modal-dimensional yet high-spatial (pixel)-resolution (as many spatial points as the pixel number on the structure in the video frame) modal model is established in the spatiotemporal video domain with full-field modal parameters first estimated from line-of-sight video measurements of the operating structure. Then in order to simulate new dynamic response of the structure subject to a new force, the force is projected onto each modal domain, and the modal response is computed by solving each individual single-degree-of-freedom system in the modal domain. The simulated modal responses are then synthesized by the full-field mode shapes using modal superposition to obtain the simulated full-field structural dynamic response. Finally, the simulated structural dynamic response is embedded into the original video, replacing the original motion of the video, thus generating a new photo-realistic, physically accurate video that enables a realistic, high-fidelity visualization/animation of the simulated full-field vibration of the structure. Laboratory experiments are conducted to validate the proposed method, and the error sources and limitations in practical implementations are also discussed. Compared with high-fidelity finite element computer model simulations of structural dynamics, the video-based simulation method removes the need to explicitly model the structure's physics. In addition, the photo-realistic, physically accurate simulated video provides a realistic visualization/animation of the full-field structural dynamic response, which was not traditionally available. Lastly, these features of the proposed method should enable a new alternative to the traditional computer-aided finite element model simulation for high-fidelity simulating and realistically visualizing full-field structural dynamics in a relatively efficient and user-friendly manner.

42 ENGINEERING↗

Kβ X-ray Emission Spectra Analysis Using Bayesian Optimization

The Kβ X-ray emission spectrum of 3 d transition metals is rich with electronic and structural information due to strong exchange interactions with the valence shell of the metal, and has become crucial for understanding their spin and oxidation states. The spectrum is commonly treated using crystal-field multiplet theory, a semi-empirical theory that uses tunable parameters to control the strength of the effects present in X-ray emission spectroscopy (XES). However, determining the experimental values of these parameters remains a challenge. We present a methodology that applies Bayesian optimization to crystal-field multiplet theory to determine parameter values. The algorithm is tested on the X-ray emission spectra of a collection of Mn, Co, and Ni oxides. We are able to find optimal values for the four most impactful parameters: Slater−Condon reduction factors F dd , F pd , and G pd , and crystal field splitting 10 Dq . The algorithm produces significantly improved accuracy compared to current analysis methods, and probes interparameter dependencies by modeling the error landscape. This advancement enhances XES analysis by offering an approach of obtaining quantitative electronic structural information on 3 d transition metal valence shells, facilitating applications across various scientific fields.

Bayesian optimization↗

Laser pointing determination for the geoscience laser altimeter system

The Geoscience Laser Altimeter System (GLAS) is a space-based lidar being developed to monitor changes in the mass balance of the Earth's polar ice sheets (Thomas et al. 1985). GLAS is part of NASA's Earth Observing System (Schutz 1995), and is being designed to launch into a 600 km circular polar orbit in the year 2001, for continuous operation over 3 to 5 years. The orbit's 94 degree inclination has been selected to allow good coverage and profile patterns over the ice sheets of Greenland and Antarctica. The GLAS mission uses a small dedicated spacecraft provided by Ball Aerospace, which is required to have a very stable nadir and zenith pointing platform which points to within approximately 100 urad (20 arcseconds) of Nadir. Accurate knowledge of the laser beam's pointing angle (in the far field) is critical since pointing the laser beam away from nadir biases the altimetry measurements (Gardner 1992, Bufton et al. 1991). This error is a function of the distance of the laser centroid off nadir multiplied by the orbit altitude and the tangent of the slope angle of the terrain. Most of the ice sheet surface slopes are less than 1? resulting in pointing knowledge bias of only 7.6 cm with 7.3 urad accuracy, and overall single shot height accuracy of approximately 15 cm. However, over a 3 deg surface slope pointing knowledge to approximately 7.3 urad is the largest error source (23 cm) in achieving 26 cm height accuracy. The GLAS design incorporates a stellar reference system (SRS) to relate the laser beam pointing angle to the star field to an accuracy of 7.3 urad. The stellar reference system combines an attitude determination system (ADS) operating from 4 to 10 Hz coupled to a 40 Hz laser reference system (LRS) to perform this task.

Miller, Pamela S.↗

POLARBEAR constraints on cosmic birefringence and primordial magnetic fields

Here, we constrain anisotropic cosmic birefringence using four-point correlations of even-parity E-mode and odd-parity B-mode polarization in the cosmic microwave background measurements made by the POLARization of the Background Radiation (POLARBEAR) experiment in its first season of observations. We find that the anisotropic cosmic birefringence signal from any parity-violating processes is consistent with zero. The Faraday rotation from anisotropic cosmic birefringence can be compared with the equivalent quantity generated by primordial magnetic fields if they existed. The POLARBEAR nondetection translates into a 95% confidence level (C.L.) upper limit of 93 nanogauss (nG) on the amplitude of an equivalent primordial magnetic field inclusive of systematic uncertainties. This four-point correlation constraint on Faraday rotation is about 15 times tighter than the upper limit of 1380 nG inferred from constraining the contribution of Faraday rotation to two-point correlations of B-modes measured by Planck in 2015. Metric perturbations sourced by primordial magnetic fields would also contribute to the B-mode power spectrum. Using the POLARBEAR measurements of the B-mode power spectrum (two-point correlation), we set a 95% C.L. upper limit of 3.9 nG on primordial magnetic fields assuming a flat prior on the field amplitude. This limit is comparable to what was found in the Planck 2015 two-point correlation analysis with both temperature and polarization. Finally, we perform a set of systematic error tests and find no evidence for contamination. This work marks the first time that anisotropic cosmic birefringence or primordial magnetic fields have been constrained from the ground at subdegree scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Tidal Hydrodynamic Model for Cook Inlet, Alaska, to Support Tidal Energy Resource Characterization

Cook Inlet in Alaska has been identified as a prime site in the U.S. for potential tidal energy development, because of its enormous tidal power potential that accounts for nearly one-third of the national total. As one important step to facilitate tidal energy development, a tidal hydrodynamic model based on the unstructured-grid, finite-volume community ocean model (FVCOM) was developed for Cook Inlet to characterize the tidal stream energy resource. The model has a grid resolution that varies from about 1000 m at the open boundary to 100–300 m inside the Inlet. Extensive model validation was achieved by comparing model predictions with field observations for tidal elevation and velocity at various locations in Cook Inlet. The error statistics confirmed the model performs reasonably well in capturing the tidal dynamics in the system, e.g., R2 > 0.98 for tidal elevation and generally > 0.9 for velocity. Model results suggest that tides in Cook Inlet evolve from progressive waves at the entrance to standing waves at the upper Inlet, and that semi-diurnal tidal constituents are amplified more rapidly than diurnal constituents. The model output was used to identify hotspots that have high energy potential and warrant additional velocity and turbulence measurements such as East Foreland, where averaged power density exceeds 5 kw/m2. Lastly, a tidal energy extraction simulation was conducted for a hypothetical turbine farm configuration at the Forelands cross section to evaluate tidal energy extraction and resulting changes in far-field hydrodynamics.

16 TIDAL AND WAVE POWER↗

An Evaluation of Departmental Radiation Oncology Incident Reports: Anticipating a National Reporting System

Purpose: Systems to ensure patient safety are of critical importance. The electronic incident reporting systems (IRS) of 2 large academic radiation oncology departments were evaluated for events that may be suitable for submission to a national reporting system (NRS). Methods and Materials: All events recorded in the combined IRS were evaluated from 2007 through 2010. Incidents were graded for potential severity using the validated French Nuclear Safety Authority (ASN) 5-point scale. These incidents were categorized into 7 groups: (1) human error, (2) software error, (3) hardware error, (4) error in communication between 2 humans, (5) error at the human-software interface, (6) error at the software-hardware interface, and (7) error at the human-hardware interface. Results: Between the 2 systems, 4407 incidents were reported. Of these events, 1507 (34%) were considered to have the potential for clinical consequences. Of these 1507 events, 149 (10%) were rated as having a potential severity of ≥2. Of these 149 events, the committee determined that 79 (53%) of these events would be submittable to a NRS of which the majority was related to human error or to the human-software interface. Conclusions: A significant number of incidents were identified in this analysis. The majority of events in this study were related to human error and to the human-software interface, further supporting the need for a NRS to facilitate field-wide learning and system improvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of improved gravity field estimates using existing altimeter data

The formulation of a Fourier series and geographic representation expressions for orbit error were reported. Addition activities include the study of undulation errors in the Lagrangian formulation, and the development and testing of all the necessary software for the above expression. Additionally, the matrix formulations that led to the formation of observed equations and covariance propagation were developed.

Source record↗

MO-FG-202-07: Real-Time EPID-Based Detection Metric For VMAT Delivery Errors

Purpose: To create and test an accurate EPID-frame-based VMAT QA metric to detect gross dose errors in real-time and to provide information about the source of error. Methods: A Swiss cheese model was created for an EPID-based real-time QA process. The system compares a treatmentplan- based reference set of EPID images with images acquired over each 2° gantry angle interval. The metric utilizes a sequence of independent consecutively executed error detection Methods: a masking technique that verifies infield radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment to quantify rotation, scaling and translation; standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each test were determined. For algorithm testing, twelve different types of errors were selected to modify the original plan. Corresponding predictions for each test case were generated, which included measurement-based noise. Each test case was run multiple times (with different noise per run) to assess the ability to detect introduced errors. Results: Averaged over five test runs, 99.1% of all plan variations that resulted in patient dose errors were detected within 2° and 100% within 4° (∼1% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 91.5% were detected by the system within 2°. Based on the type of method that detected the error, determination of error sources was achieved. Conclusion: An EPID-based during-treatment error detection system for VMAT deliveries was successfully designed and tested. The system utilizes a sequence of methods to identify and prevent gross treatment delivery errors. The system was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of errors in real-time and indicate the error source. J. V. Siebers receives funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-H-BRA-03: Performance of a Clinical Gridded Electron Gun in Magnetic Fields: Implications for MRI-Linac Therapy

Purpose: Recent advances towards MRI Linac radiotherapy have motivated a wide range of studies characterizing electromagnetic interactions between the two devices. One of the most sensitive components is the linac electron gun. To data, only non gridded (diode) guns have been investigated however, most linac vendors utilize gridded (triode) guns, which enable efficient and robust beam gating. The purpose of this study was to develop a realistic model of a gridded gun used clinically, and to characterize its performance in magnetic fields. Methods: The gridded electron gun used on Varian high energy machines was measured using 3D laser scanning quoted as accurate to 0.1mm. Based on the scane, a detailed CAD mode was developed. From this, key geometry was extracted and a FEM model was developed (Opera/SCALA). Next, the high voltage (HV), grid voltage, and emission current were read from six dose matched TrueBeam linacs for the 6X, 10X and 15X photon modes (0 B-field). The mean values were used to represent each mode, which was simulated I constant magnetic fields from 0–200G in-line, and 0–35G perpendicular. Results: Experimentally measured HV, grid voltage, and emission current from 6X, 10X and 15X modes were respectively: 15±.03kV, 10±.08kV, 11±.03kV; 93±7V, 41±3V, and 70±6V; 327±27mA, 129±10mA, and 214±19mA. The error in simulated emission current of each mode was 3%,6%, and 3%. For in-line fields, 50% beam loss occurred at 114, 96, and 97G; for perpendicular; at 12, 13 and 14G. Sensitivity for a given geometry is primarily determined by HV setting. Conclusion: Future MRI-Linac systems will almost certainly use gridded guns. We present the first model of a clinical gridded gun, and match the experimental emission current to within 6% across three different operating modes. This clinical gun shows increased sensitivity to magnetic fields than previous work,and different modes show different sensitivity.

60 APPLIED LIFE SCIENCES↗

A Faraday-effect polarimeter for fast magnetic dynamics measurement on DIII-D

A Faraday-effect-based radial-interferometer-polarimeter diagnostic has been developed to explore fast magnetic dynamics in high-performance DIII-D plasmas. The instrument measures radial magnetic field perturbations using three chords positioned near the magnetic axis. Newly developed solid-state sources operating at 650 GHz provide phase noise down to 0.01°/$\sqrt{kHz}$ and tunable bandwidth up to 10 MHz. Various systematic errors which can contaminate the polarimetric measurement have been investigated in detail. Distortion of circular polarization due to non-ideal optical components is calibrated using a rotating quarter wave plate technique. The impact of perpendicular magnetic field, i.e., the Cotton-Mouton effect, is evaluated. The error due to non-collinearity of probe beams is minimized to less than 0.5° for electron density up to 7 × 10 19 m -3 by alignment optimization. Optical feedback, due to multiple reflections induced by the double-pass configuration, is identified and reduced. Lastly, coherent and broadband high-frequency magnetic fluctuations for DIII-D H-mode plasmas are observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of three-component aeromagnetic data

The numerical method of obtaining three field components from total field measurements, using double Fourier series expansion, is presented. The expressions for moments of the anomalous field components over a finite area are given. The magnitude and direction of the magnetization vector indicate that the vertical component of the magnetic field calculated from total field observations is more accurate at higher geomagnetic latitudes than at lower latitudes. The opposite is true for the horizontal components. The error in determining the magnetization vector directions are significantly large over most of the range of variation of declination and inclination of the vector, demonstrating the practical limitations of computing field components from total field data even under the best of conditions.

Bhattacharyya, B. K.↗

nCTEQ15 - Global analysis of nuclear parton distributions with uncertainties

We present the first official release of the nCTEQ nuclear parton distribution functions with errors. The main addition to the previous nCTEQ PDFs is the introduction of PDF uncertainties based on the Hessian method. Another important addition is the inclusion of pion production data from RHIC that give us a handle on constraining the gluon PDF. This contribution summarizes our results from arXiv:1509.00792, and concentrates on the comparison with other groups providing nuclear parton distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CAFE: A NEW RELATIVISTIC MHD CODE

We introduce CAFE, a new independent code designed to solve the equations of relativistic ideal magnetohydrodynamics (RMHD) in three dimensions. We present the standard tests for an RMHD code and for the relativistic hydrodynamics regime because we have not reported them before. The tests include the one-dimensional Riemann problems related to blast waves, head-on collisions of streams, and states with transverse velocities, with and without magnetic field, which is aligned or transverse, constant or discontinuous across the initial discontinuity. Among the two-dimensional (2D) and 3D tests without magnetic field, we include the 2D Riemann problem, a one-dimensional shock tube along a diagonal, the high-speed Emery wind tunnel, the Kelvin–Helmholtz (KH) instability, a set of jets, and a 3D spherical blast wave, whereas in the presence of a magnetic field we show the magnetic rotor, the cylindrical explosion, a case of Kelvin–Helmholtz instability, and a 3D magnetic field advection loop. The code uses high-resolution shock-capturing methods, and we present the error analysis for a combination that uses the Harten, Lax, van Leer, and Einfeldt (HLLE) flux formula combined with a linear, piecewise parabolic method and fifth-order weighted essentially nonoscillatory reconstructors. We use the flux-constrained transport and the divergence cleaning methods to control the divergence-free magnetic field constraint.

79 ASTRONOMY AND ASTROPHYSICS↗