Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Mammography X-Ray Spectra Simulated with Monte Carlo

Monte Carlo calculations have been carried out to obtain the x-ray spectra of various target-filter combinations for a mammography unit. Mammography is widely used to diagnose breast cancer. Further to Mo target with Mo filter combination, Rh/Rh, Mo/Rh, Mo/Al, Rh/Al, and W/Rh are also utilized. In this work Monte Carlo calculations, using MCNP 4C code, were carried out to estimate the x-ray spectra produced when a beam of 28 keV electrons did collide with Mo, Rh and W targets. Resulting x-ray spectra show characteristic x-rays and continuous bremsstrahlung. Spectra were also calculated including filters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Raman Spectroscopy: A New Proposal for the Detection of Leukemia Using Blood Samples

The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. The blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteer. The imprint was put under the microscope and several points were chosen for Raman measurement. All spectra were collected at confocal Raman micro-spectroscopy (Renishaw) with NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) is applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. In addition, currently the degree of damage to the bone marrow is estimated through biopsies and therefore it is a very procedure painful. The preliminary results suggest that Raman spectroscopy could be a new technique to study the bone marrow using just blood samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficiency Of The Photodynamic Therapy Using Gold Nanoparticles (np-Au) And PpIX Induced And Not Induced

The use of gold nanoparticles (np-Au) to eliminate cancer has proved to be very effective due to the fact that cancerous cells accumulate it 600% more than healthy cells. In addition they have a high capacity of absorption and dispersion of light. Therefore, the effectiveness of photodynamic therapy (PDT) could be improved by the simultaneous use of np-Au and photosensitizes (Ps), emphasizing the high efficiency of the PDT to diagnose and to treat pre-malignant and malignant processes. The aim of this work was to determine the efficiency of PDT using np-Au and protoporphyrin IX (PpIX) induced and not induced by the {delta}-aminolevulinic acid (ALA). It were found the conditions of synthesis of hydrosoluble np-Au, and were characterized by transmission electronic microscopy (TEM) and UV-VIS spectroscopy. It was realized a kinetic by TEM to determine the cellular incorporation time of np-Au, the maximum incorporation of np-Au was of 16 h. PDT was applied using different doses of np-Au and photosensitizers. It was observed that the use of PDT simultaneously with np-Au did not increase the mortality of HeLa cells. In the case of C33, when PpIX not induced is used as photosensitizer simultaneously with np-Au, the mortality increased 20%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the sensitivity and fading characteristics of an image plate system for x-ray diagnostics

Image plates (IPs) are a reusable recording media capable of detecting ionizing radiation, used to diagnose x-ray emission from laser-plasma experiments. Due to their superior performance characteristics in x-ray applications [C. C. Bradford, W. W. Peppler, and J. T. Dobbins III, Med. Phys. 26, 27 (1999) and J. Digit. Imaging. 12, 54 (1999)], the Fuji Biological Analysis System (BAS) IPs are fielded on x-ray diagnostics for the HELEN laser by the Plasma Physics Department at AWE. The sensitivities of the Fuji BAS IPs have been absolutely calibrated for absolute measurements of x-ray intensity in the energy range of 0-100 keV. In addition, the Fuji BAS IP fading as a function of time was investigated. We report on the characterization of three Fuji BAS IP responses to x-rays using a radioactive source, and discrete x-ray line energies generated by the Excalibur soft x-ray facility and the Defense Radiological Standards Centre filter-fluorescer hard x-ray system at AWE.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement and Analysis of Rotational Energy of Nitrogen Molecular Beam by REMPI

Molecular beams are powerful tools for diagnoses of solid surfaces and gas-surface interaction tests. Unfortunately, there are very few reports about experimental analysis of internal energy distribution (e.g. rotational energy) of molecular beams of diatomic or polyatomic molecules, because measurement of internal energy distribution is very difficult. Spectroscopic measurement techniques based on resonantly enhanced multiphoton ionization (REMPI) is very powerful for measurement in highly rarefied gas flows. In this study, the REMPI method is applied to measurement of rotational energy distribution of nitrogen molecular beams. The REMPI spectrum of the molecular beam indicates the rotational temperature higher than the translational temperature of 7.2 K estimated by assuming isentropic flows. The O and P branches of the REMPI spectrum correspond to the rotational temperature of 30 K, but the S branch of the spectrum deviates from that at 30 K. It seems to be because the non-equilibrium rotational energy distribution of the molecular beam deviates from the Boltzmann distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using numerical simulations to extract parameters of toroidal electron plasmas from experimental data

Measurements of the image charge induced on electrodes provide the primary means of diagnosing plasmas in the Lawrence Non-neutral Torus II (LNT II) [Phys. Rev. Lett. 100, 155001 (2008)]. Therefore, it is necessary to develop techniques that determine characteristics of the electron plasma from features of the induced image charge signal. This paper presents a numerical study which finds that the frequency of the image charge signal due to the toroidal version of the m=1 diocotron mode is proportional to the total trapped charge and inversely proportional to magnetic field strength, as in the cylindrical case. In the toroidal case, additional information about the m=1 motion of the plasma can be obtained by analysis of the image charge signal amplitude and shape. Finally, results from the numerical simulations are compared to experimental data from the LNT II and plasma characteristics are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Directional ion emission from thin films under femtosecond laser irradiation

Thin films of nickel have been irradiated using femtosecond laser pulses in vacuum. Subsequent emission of plasma ions is diagnosed using an ion probe. Angular distributions of the emitted ions are presented for a range of target film thicknesses. Data are compared to the Anisimov model of plasma expansion [S. I. Anisimov, D. Bauerle, and B. S. Luk'yanchuk, Phys. Rev. B 48, 12076 (1993)]. The tendency of the ions to be ejected at small angles to the normal of the target surface is explained in terms of the initial conditions of the plume. Results are explained in terms of the initial shape and adiabatic index of the plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beta-induced Alfven-acoustic eigenmodes in National Spherical Torus Experiment and DIII-D driven by beam ions

Kinetic theory and experimental observations of a special class of energetic particle driven instabilities called here beta-induced Alfven-acoustic eigenmodes (BAAEs) are reported confirming, previous results [N. N. Gorelenkov et al., Plasma Phys. Controlled Fusion 49, B371 (2007)]. The kinetic theory is based on the ballooning dispersion relation where the drift frequency effects are retained. BAAE gaps are recovered in kinetic theory. It is shown that the observed certain low-frequency instabilities on DIII-D [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] and National Spherical Torus Experiment [M. Ono, S. M. Kaye, Y.-K. M. Peng et al., Nucl. Fusion 40, 557 (2000)] are consistent with their identification as BAAEs. BAAEs deteriorate the fast ion confinement in DIII-D and can have a similar effect in next-step fusion plasmas, especially if excited together with multiple global toroidicity-induced shear Alfven eigenmode instabilities. BAAEs can also be used to diagnose safety factor profiles, a technique known as magnetohydrodynamic spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Picosecond time scale dynamics of short pulse laser-driven shocks in tin

The dynamics of high strain rate shock waves driven by a subnanosecond laser pulse in thin tin slabs have been investigated. These shocks, with pressure up to 1 Mbar, have been diagnosed with an 800 nm wavelength ultrafast laser pulse in a pump-probe configuration, which measured reflectivity and two-dimensional interferometry of the expanding rear surface. Time-resolved rear surface expansion data suggest that we reached pressures necessary to shock melt tin upon compression. Reflectivity measurements, however, show an anomalously high drop in the tin reflectivity for free standing foils, which can be attributed to microparticle formation at the back surface when the laser-driven shock releases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of hepatic fibrosis in rats with x-ray diffraction enhanced imaging

X-ray diffraction enhanced imaging (DEI) is a phase contrast technique that generates excellent contrast of biological soft tissues compared to conventional absorption radiography. We explore the application of DEI in the diagnosis of hepatic fibrosis. The produced refraction contrast images of fibrous rat liver samples show clearly abnormal liver architectures. Moreover, by comparing to histological pictures, different stages of fibrosis are discriminated, and the corresponding morphological features are analyzed. Besides, quantitative analyses of texture features are presented. The results reported herein show that DEI can be a potential noninvasive technique to diagnose and stage hepatic fibrosis.

60 APPLIED LIFE SCIENCES↗

Nested observer for linear hybrid dynamical systems

The synthesis of observers for linear hybrid dynamical systems ''HDS,'' is significant from the point of view of the applications (control, diagnoses...); it is still, largely open. We proposed a new approach inspired from a new method of identification, where we could obtain better results with respect to discrimination between the discrete states in conflicts and time necessary to this latter. The results of the suggested technique proved to be satisfactory.

97 MATHEMATICS AND COMPUTING↗

A H-infinity Fault Detection and Diagnosis Scheme for Discrete Nonlinear System Using Output Probability Density Estimation

In this paper, a H-infinity fault detection and diagnosis (FDD) scheme for a class of discrete nonlinear system fault using output probability density estimation is presented. Unlike classical FDD problems, the measured output of the system is viewed as a stochastic process and its square root probability density function (PDF) is modeled with B-spline functions, which leads to a deterministic space-time dynamic model including nonlinearities, uncertainties. A weighting mean value is given as an integral function of the square root PDF along space direction, which leads a function only about time and can be used to construct residual signal. Thus, the classical nonlinear filter approach can be used to detect and diagnose the fault in system. A feasible detection criterion is obtained at first, and a new H-infinity adaptive fault diagnosis algorithm is further investigated to estimate the fault. Simulation example is given to demonstrate the effectiveness of the proposed approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effective Dose from Stray Radiation for a Patient Receiving Proton Therapy for Liver Cancer

Because of its advantageous depth-dose relationship, proton radiotherapy is an emerging treatment modality for patients with liver cancer. Although the proton dose distribution conforms to the target, healthy tissues throughout the body receive low doses of stray radiation, particularly neutrons that originate in the treatment unit or in the patient. The aim of this study was to calculate the effective dose from stray radiation and estimate the corresponding risk of second cancer fatality for a patient receiving proton beam therapy for liver cancer. Effective dose from stray radiation was calculated using detailed Monte Carlo simulations of a double-scattering proton therapy treatment unit and a voxelized human phantom. The treatment plan and phantom were based on CT images of an actual adult patient diagnosed with primary hepatocellular carcinoma. For a prescribed dose of 60 Gy to the clinical target volume, the effective dose from stray radiation was 370 mSv; 61% of this dose was from neutrons originating outside of the patient while the remaining 39% was from neutrons originating within the patient. The excess lifetime risk of fatal second cancer corresponding to the total effective dose from stray radiation was 1.2%. The results of this study establish a baseline estimate of the stray radiation dose and corresponding risk for an adult patient undergoing proton radiotherapy for liver cancer and provide new evidence to corroborate the suitability of proton beam therapy for the treatment of liver tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complementary ion and extreme ultra-violet spectrometer for laser-plasma diagnosis

Simultaneous detection of extreme ultra-violet (XUV) and ion emission along the same line of sight provides comprehensive insight into the evolution of plasmas. This type of combined spectroscopy is applied to diagnose laser interaction with a spray target. The use of a micro-channel-plate detector assures reliable detection of both XUV and ion signals in a single laser shot. The qualitative analysis of the ion emission and XUV spectra allows to gain detailed information about the plasma conditions, and a correlation between the energetic proton emission and the XUV plasma emission can be suggested. The measured XUV emission spectrum from water spray shows efficient deceleration of laser accelerated electrons with energies up to keV in the initially cold background plasma and the collisional heating of the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond X-ray Diffraction: Applications for Laser-Irradiated Materials

Over the past few years short pulse x-ray diffraction at the nanosecond and picosecond level has become an established technique in many high-power laser laboratories for interrogating the lattice response of laser-perturbed and shocked matter, and is now finding applications in diagnosing the state of crystalline materials subject to quasi-isentropic compression. We review some of the previous results obtained in this area, for example the direct observation of coherent phonons, the first direct confirmation of the alpha-epsilon transition in shocked iron, and recent measurements indicating that the strength of matter can be measured at shock pressures exceeding a Mbar. The majority of sources used to date have been laser-plasma based, with some work being performed using 3{sup rd} generation synchrotron sources. However, the development of 4{sup th} generation x-ray free-electron lasers, such as LCLS, afford many new opportunities, with pulse lengths in the femtosecond regime. The extremely low divergence and monochromatic nature of the LCLS beam make it well suited to study compressed polycrystalline matter, especially samples with small grain sizes. At extremely short pulse lengths, such that the pulse is shorter than an x-ray extinction depth traversal time, the diffraction process itself becomes time-dependent, and in certain cases the full wave-field solution will be required, particularly if the matter itself is being rapidly perturbed, as will occur if the intense x-ray radiation is used to create warm dense matter, as in recent experiments on FLASH at DESY.

36 MATERIALS SCIENCE↗

Design And Performance Of Optical Detectors Fabrication Setup Using Pulsed Laser Deposition (PLD)

PLD system was used in the preparation of nano structured thin layers to be used as optical detectors. Our home made on--axis PLD setup utilizes XeCl excimer laser (308 nm, Pulse duration of 7 ns, repetition rate of 200 Hz). The laser energy is kept at 8 mj, and the vacuum chamber has been pumped to a background pressure of 10{sup -5} mbar. The films can be grown at different substrate temperatures in the range of 25-400 deg. C. The substrate temperature was always kept below 400 deg. C by using advanced temperature control system. The target-to-substrate distance was variable from 2 to 6 cm. SiO{sub 2} was used as substrates because of its low refractive index and high transparency in the UV, visible and near infrared ranges of spectra. LIPS technique has been used for plasma diagnoses during film deposition, using a double monochromator provided with photon detector. Homogenous thin films in the order of 20-200 nm thickness were obtained. Moreover, both amorphous and crystalline thin films can be obtained by adjusting the substrate temperature, target--substrate distance, type of substrate and finally pressure of ambient gas.

36 MATERIALS SCIENCE↗

IBSIMU: A three-dimensional simulation software for charged particle optics

A general-purpose three-dimensional (3D) simulation code IBSIMU for charged particle optics with space charge is under development at JYFL. The code was originally developed for designing a slit-beam plasma extraction and nanosecond scale chopping for pulsed neutron generator, but has been developed further and has been used for many applications. The code features a nonlinear FDM Poisson's equation solver based on fast stabilized biconjugate gradient method with ILU0 preconditioner for solving electrostatic fields. A generally accepted nonlinear plasma model is used for plasma extraction. Magnetic fields can be imported to the simulations from other programs. The particle trajectories are solved using adaptive Runge-Kutta method. Steady-state and time-dependent problems can be modeled in cylindrical coordinates, two-dimensional (slit) geometry, or full 3D. The code is used via C++ programming language for versatility but it features an interactive easy-to-use postprocessing tool for diagnosing fields and particle trajectories. The open source distribution and public documentation make the code well suited for scientific use. IBSIMU has been used for modeling the 14 GHz ECR ion source extraction and for designing a four-electrode extraction for a 2.45 GHz microwave ion source at Jyvaeskylae. A grid extraction has also been designed for producing large uniform beam for creating conditions similar to solar wind. The code has also been used to design a H{sup -} extraction with electron dumping for the Cyclotron Institute of Texas A and M University.

43 PARTICLE ACCELERATORS↗

Reaction-in-flight neutrons as a signature for shell mixing in National Ignition Facility capsules

Analytic calculations and results from computational simulations are presented that suggest that reaction-in-flight (RIF) neutrons can be used to diagnose mixing of the ablator shell material into the fuel in deuterium-tritium (DT) capsules designed for the National Ignition Facility (NIF) [J. A. Paisner, J. D. Boyes, S. A. Kumpan, W. H. Lowdermilk, and M. S. Sorem, Laser Focus World 30, 75 (1994)]. Such mixing processes in NIF capsules are of fundamental physical interest and can have important effects on capsule performance, quenching the total thermonuclear yield. The sensitivity of RIF neutrons to hydrodynamical mixing arises through the dependence of RIF production on charged-particle stopping lengths in the mixture of DT fuel and ablator material. Since the stopping power in the plasma is a sensitive function of the electron temperature and density, it is also sensitive to mix. RIF production scales approximately inversely with the degree of mixing taking place, and the ratio of RIF to down-scattered neutrons provides a measure of the mix fraction and/or the mixing length. For sufficiently high-yield capsules, where spatially resolved RIF images may be possible, neutron imaging could be used to map RIF images into detailed mix images.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗