Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Cryogenic Optical and Spin Scanning Probe Station for High-throughput Characterization of Solid-state Quantum Defects

This final technical report provides an overview of the key milestones achieved by Advanced Research Systems (ARS), a DOE SBIR/STTR Grant Recipient. ARS’s main objective was to develop a prototype of the Closed Cycle Cryogenic Quantum Probe Station (Avalanche). Designed for near field spectroscopy (Tip Enhanced Photoluminescence, TEPL and Tip Enhanced Raman Spectroscopy TERS) and far field spectroscopy (micro-Raman, micro-PL) is in the final stage of completion. The critical components have been tested and the final System Test of the AFM is scheduled for August 2025.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cryogenic Autogenous Pressurization Testing for Robotic Refueling Mission 3

A wick-heater system has been selected for use to pressurize the Source Dewar of the Robotic Refueling Mission Phase 3 on-orbit cryogen transfer experiment payload for the International Space Station. Experimental results of autogenous pressurization of liquid argon and liquid nitrogen using a prototype wick-heater system are presented. The wick-heater generates gas to increase the pressure in the tank while maintaining a low bulk fluid temperature. Pressurization experiments were performed in 2013 to characterize the performance of the wick heater. This paper describes the experimental setup, pressurization results, and analytical model correlations.

cryogenics↗

NOVEL CRYOGENIC ENGINEERING SOLUTIONS FOR THE NEW AUSTRALIAN RESEARCH REACTOR OPAL

In August 2006 the new 20MW low enriched uranium research reactor OPAL went critical. The reactor has 3 main functions, radio pharmaceutical production, silicon irradiation and as a neutron source. Commissioning on 7 neutron scattering instruments began in December 2006. Three of these instruments (Small Angle Neutron Scattering, Reflectometer and Time-of-flight Spectrometer) utilize cold neutrons.The OPAL Cold Neutron Source, located inside the reactor, is a 20L liquid deuterium moderated source operating at 20K, 330kPa with a nominal refrigeration capacity of 5 kW and a peak flux at 4.2meV (equivalent to a wavelength of 0.4nm). The Thermosiphon and Moderator Chamber are cooled by helium gas delivered at 19.8K using the Brayton cycle. The helium is compressed by two 250kW compressors (one with a variable frequency drive to lower power consumption).A 5 Tesla BSCCO (2223) horizontal field HTS magnet will be delivered in the 2{sup nd} half of 2007 for use on all the cold neutron instruments. The magnet is cooled by a pulse tube cryocooler operating at 20K. The magnet design allows for the neutron beam to pass both axially and transverse to the field. Samples will be mounted in a 4K to 800K Gifford-McMahon (GM) cryofurnace, with the ability to apply a variable electric field in-situ. The magnet is mounted onto a tilt stage. The sample can thus be studied under a wide variety of conditions.A cryogen free 7.4 Tesla Nb-Ti vertical field LTS magnet, commissioned in 2005 will be used on neutron diffraction experiments. It is cooled by a standard GM cryocooler operating at 4.2K. The sample is mounted in a 2{sup nd} GM cryocooler (4K-300K) and a variable electric field can be applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Repeatability of Cryogenic Multilayer Insulation

Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4 whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 16. Based on detailed statistical analysis, the data has been shown to be statistically significant.

multilayer insulation↗

Repeatability of Cryogenic Multilayer Insulation

Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

multilayer insulation↗

Robotic Refueling Mission 3: Cryogenic Demonstration Subsystem Operations

The Robotic Refueling Mission 3 (RRM3) payload was installed on the International Space Station (ISS) in December 2018. Its Cryogenic Demonstation Subsystem (CDS) was loaded with 19 kilograms of liquid methane, for demonstration of on-orbit storage and transfer. We provide a short description of the design and ground testing of the CDS, and then discuss the on-orbit operations through the first half of 2019.

Cryogenic Fluid Storage↗

A Mechanical Test Frame for Property Evaluations at Cryogenic Temperature

On-board storage of hydrogen fuel has been designated as a limiting factor in the advancement of fuel cell technologies in the automotive industry. The use of cryo-compressed Type III pressure vessels presents one option to overcome this barrier. These multi-material vessels will be expected to perform at high pressure and extreme low temperatures, which creates a complex engineering design challenge. Many materials exhibit highly temperature-dependent properties, which must be considered for the efficient design of cryo-compressed pressure vessels. Complicating this issue, mechanical property data at cryogenic temperatures is sparse. This technical paper provides a description of a test apparatus commissioned specifically to help address this shortcoming. A mechanical test frame was retrofitted with a continuous flow cryostat capable to evaluate various mechanical properties throughout a broad temperature range of 25 °C to -269 °C with a load limit of 10 kN. An investigation of the thermomechanical properties of an epoxy resin was carried out as a demonstration.

Mechanical characterization, cryogenic pressure ve↗

δ 2 H isotopic offsets in xylem water measurements under cryogenic vacuum distillation: Quantifying and correcting wood‐water hydrogen exchange influences

Stable isotopes δ 18 O and δ 2 H are used to infer vegetation water sources. In some studies, significant xylem water δ 2 H offsets from potential source waters have been observed. The offsets appear to be more prevalent with cryogenic vacuum distillation (CVD) of plant water. Hypothesized mechanisms for these offsets include changes during plant water uptake and transport, and methodological problems. We propose that a large portion of the offsets are due to hydrogen isotope exchange between xylem water and non-crystalline hydroxyl groups of wood cellulose and hemicellulose during CVD. We present a method for estimating the hypothesized isotopic exchange between wood tissues and water, which is the result of Rayleigh and equilibrium fractionation. To estimate the exchange, we use published wood properties for North American tree species and isotope chemical relationships as a function of moisture content, CVD temperature and water extraction efficiency. A simple model of exchange between xylem water and hydroxyl groups captures the range of observations in studies in which CVD and non-CVD methods were compared. To evaluate the model, we compared observed δ 2 H offsets (sw-excess) values from two field datasets (90°C, n = 364, and 170°C, n = 43) to δ 2 H offsets estimated with our chemical model. We found good agreement between observed and estimated δ 2 H offsets for samples extracted at 90°C (r 2 = 0.69) but not for samples extracted at 170°C (r 2 = 0.20). The offset may be eliminated by increasing the extraction temperature to 229°C or by adding a standard sufficient to raise the moisture content to >150%. A correction can also be approximated by applying a theoretical calculation based on the extraction temperature, moisture content and water extraction efficiency.

54 ENVIRONMENTAL SCIENCES↗

Further Experiments Comparing Direct Vapor Equilibration and Cryogenic Vacuum Distillation for Plant Water Stable Isotope Analysis

Recent work compared six plant water extraction approaches for hydrogen and oxygen stable isotope analysis. Previously it was believed that these ex- traction approaches would provide analytes whose δ 2 H and δ 18 O values were similar, but the authors found significant differences in the isotopic composition of the produced analytes. We report a short followup experiment to specially explore systematic differences between one form of cryogenic vacuum distillation (hereafter CVD-2 from, based on Koeniger et al.[2]), and direct vapour equilibration (DVE[3, 4]).

60 APPLIED LIFE SCIENCES↗

High Power Cryogenic Targets

The development of high power cryogenic targets for use in parity violating electron scattering has been a crucial ingredient in the success of those experiments. As we chase the precision frontier, the demands and requirements for these targets have grown accordingly. We discuss the state of the art, and describe recent developments and strategies in the design of the next generation of these targets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Machine Learning Techniques for Pile-Up Rejection in Cryogenic Calorimeters

CUORE Upgrade with Particle IDentification (CUPID) is a foreseen ton-scale array of Li 2 MoO 4 (LMO) cryogenic calorimeters with double readout of heat and light signals. Its scientific goal is to fully explore the inverted hierarchy of neutrino masses in the search for neutrinoless double beta decay of 100 Mo. Pile-up of standard double beta decay of the candidate isotope is a relevant background. We generate pile-up heat events via injection of Joule heater pulses with a programmable waveform generator in a small array of LMO crystals operated underground in the Laboratori Nazionali del Gran Sasso, Italy. This allows to label pile-up pulses and control both time difference and underlying amplitudes of individual heat pulses in the data. We present the performance of supervised learning classifiers on data and the attained pile-up rejection efficiency.

47 OTHER INSTRUMENTATION↗

Enhanced Surface Properties and Microstructure Evolution of Cr12MoV Using Ultrasonic Surface Rolling Process Combined with Deep Cryogenic Treatment

In this study, the enhanced surface properties and microstructure evolution of quenched and tempered cold work die steel Cr12MoV, which were induced by ultrasonic surface rolling process combined with deep cryogenic treatment (UDCT), were systematically investigated. The results indicated that UDCT had an advantage over conventional ultrasonic surface rolling process (USRP) in improving surface mechanical properties, including smaller surface roughness and smoother machined surface with less cracks and defects; higher surface microindentation hardness with the value of ~ 890 HV (increased by ~ 6.2% compared with USRP); and lower friction coefficient. Such enhancements in surface properties are mainly attributed to the martensitic transformation of retained austenite, the dispersion strengthening of small secondary carbides and the homogenized carbides distribution during UDCT.

36 MATERIALS SCIENCE↗

Cryogenic Vibrational Spectroscopy Provides Unique Fingerprints for Glycan Identification

The structural characterization of glycans by mass spectrometry is particularly challenging. This is because of the high degree of isomerism in which glycans of the same mass can differ in their stereochemistry, attachment points, and degree of branching. Here we show that the addition of cryogenic vibrational spectroscopy to mass and mobility measurements allows one to uniquely identify and characterize these complex biopolymers. We investigate six disaccharide isomers that differ in their stereochemistry, attachment point of the glycosidic bond, and monosaccharide content, and demonstrate that we can identify each one unambiguously. Even disaccharides that differ by a single stereogenic center or in the monosaccharide sequence order show distinct vibrational fingerprints that would clearly allow their identification in a mixture, which is not possible by ion mobility spectrometry/mass spectrometry alone. Moreover, this technique can be applied to larger glycans, which we demonstrate by distinguishing isomeric branched and linear pentasaccharides. The creation of a database containing mass, collision cross section, and vibrational fingerprint measurements for glycan standards should allow unambiguous identification and characterization of these biopolymers in mixtures, providing an enabling technology for all fields of glycoscience. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-entropy Al 0.3 CoCrFeNi alloy fibers with high tensile strength and ductility at ambient and cryogenic temperatures

High-entropy alloys (HEAs) are multi-component systems based on novel alloy composition designs with entropy maximization. They feature an array of unique mechanical properties when compared with traditional alloys. In this study, HEA fibers with diameters ranging from 1 to 3.15 mm in diameter, with the composition of Al 0.3 CoCrFeNi (atomic percent, at.%), were successfully fabricated by hot-drawing, followed by microstructural characterization using scanning-electron microscopy (SEM) and transmission-electron microscopy (TEM). The compositional variations within and between fibers were determined using energy-dispersive X-ray spectroscopy in TEM along with atomic-probe tomography (APT). These analyses revealed a homogeneous face-centered cubic (FCC) structure in the as-cast material, while post processing (e.g., forging and wire drawing) produced nanosized B2 particles in an FCC matrix. Electron back-scatter diffraction (EBSD) was used to determine the evolution of the texture and grain boundary character after processing of the fibers. The tensile strength and plasticity of the fibers were determined at both 298 K (1207 MPa/7.8%) and 77 K (1600 MPa/17.5%). Detailed TEM analyses revealed that the improvement of mechanical properties at 77 K (i.e. increased strength and ductility) is due to a change in deformation mechanisms from the planar slip of dislocations to nano-twinning. Such properties could be beneficial for cryogenic applications.

36 MATERIALS SCIENCE↗

Balancing sugar recovery and inhibitor generation during energycane processing: Coupling cryogenic grinding with hydrothermal pretreatment at low temperatures

Pretreatment of lignocellulosic biomass at high temperatures or with oxidizing chemicals generate various inhibitors that restrict the efficient bioconversion of sugars in subsequent steps. The present study systematically investigates individual and combinatorial effects of pretreatment parameters on the generation of inhibitors. Herein, a plot between pretreatment temperature and inhibitor revealed optimum pretreatment temperature for energycane bagasse i.e., 170 °C beyond which total inhibitor production increased exponentially. No inhibitor production was observed on mechanical processing i.e., disk milling/cryogenic grinding of biomass. Evaluation of response surface regression exhibited that biomass solids loading has a significant effect on inhibitor generation at higher temperatures. The concentrations of certain inhibitors such as acetic acid, furfurals, and HMF increased more than 3-folds on doubling the solids loading. Furthermore, a novel low-severity approach of low-temperature hydrothermal pretreatment coupled with cryogenic grinding for lignocellulosic biomasses has been introduced which improved sugar yields while maintaining a low inhibitor concentration.

09 BIOMASS FUELS↗

Prediction of heat transfer coefficients for forced convective boiling of N 2 -hydrocarbon mixtures at cryogenic conditions using artificial neural networks

A key problem faced in the design of heat exchangers, especially for cryogenic applications, is the determination of convective heat transfer coefficients in two-phase flow such as condensation and boiling of non-azeotropic refrigerant mixtures. Here, this paper proposes and evaluates three models for estimating the convective coefficient during boiling. These models are developed using computational intelligence techniques. The performance of the proposed models is evaluated using the mean relative error (mre), and compared to two existing models: the modified Granryd’s correlation and the Silver-Bell-Ghaly method. The three proposed models are distinguished by their architecture. The first is based on directly measured parameters (DMP-ANN), the second is based on equivalent Reynolds and Prandtl numbers (eq-ANN), and the third on effective Reynolds and Prandtl numbers (eff-ANN). In conclusion, the results demonstrate that the proposed artificial neural network (ANN)-based approaches greatly outperform available methodologies. While Granryd's correlation predicts experimental data within a mean relative error mre = 44% and the S-B-G method produces mre = 42%, DMP-ANN has mre = 7.4% and eff-ANN has mre = 3.9%. Considering that eff-ANN has the lowest mean relative error (one tenth of previously available methodologies) and the broadest range of applicability, it is recommended for future calculations. Implementation is straightforward within a variety of platforms and the matrices with the ANN weights are given in the appendix for efficient programming.

42 ENGINEERING↗