Limitations of reanalysis data for wind power applications

Wind energy resource estimates commonly depend on simulated wind speed profiles generated by reanalysis or weather models due to the lack of long time series measurements with sufficient coverage at relevant heights (roughly 90 m above ground). However, modeled data, including reanalyses, can be noisy and display a wide range of biases and errors, variously attributed to terrain effects, poor coverage of assimilated inputs, and model resolution. Wind generation records, if available at high temporal and geographical resolution, can provide a proxy for wind measurements and allow for evaluation of reanalyses and weather model wind time series. We use a 7-year-long data set of hourly, plant-level generation records from over 100 wind plants across Texas to evaluate two commonly used reanalysis data sets (MERRA2 and ERA5). Additionally, we use 1-year of records (2019) to evaluate an operational, high-resolution regional weather modeling product (HRRR v3). We find that across the region, and across all modeling products, the modeled representation of wind generation (i.e., wind speeds at hub heights passed through a power curve) has relatively small mean errors when aggregated daily, but that accuracy and hourly correlation have a strong diurnal sensitivity. Accuracy and correlation systematically decline through the evening and markedly improve after sunrise. These diurnal patterns persist even in the highest resolution model tested (HRRR v3). We hypothesize the nighttime decline in accuracy is mostly due to poorly represented boundary layer conditions, perhaps related to model representation of stability, while other uncertainties (such as wake effects) play a secondary role.

17 WIND ENERGY↗

Forward production of prompt neutrinos from charm in the atmosphere and at high energy colliders

The high-energy atmospheric neutrino flux is dominated by neutrinos from the decays of charmed hadrons produced in the forward direction by cosmic ray interactions with air nuclei. We evaluate the charm contributions to the prompt atmospheric neutrino flux as a function of the center-of-mass energy √s of the hadronic collision and of the center-of-mass rapidity y of the produced charm hadron. Uncertainties associated with parton distribution functions are also evaluated as a function of y. We find that the y coverage of LHCb for forward heavy-flavour production, complemented by the angular coverage of present and future forward neutrino experiments at the LHC, bracket the most interesting y regions for the prompt atmospheric neutrino flux. At √s = 14 TeV foreseen for the HL-LHC phase, nucleon collisions in air contribute to the prompt neutrino flux prominently below E ν ~ 10 7 GeV. Measurements of forward charm and/or forward neutrinos produced in hadron collisions up to √s = 100 TeV, which might become possible at the FCC, are relevant for the prompt atmospheric neutrino flux up to E ν = 10 8 GeV and beyond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Updates to the Regional Seismic Travel Time (RSTT) Model: 2. Path-dependent Travel-time Uncertainty

Abstract The regional seismic travel time (RSTT) model and software were developed to improve travel-time prediction accuracy by accounting for three-dimensional crust and upper mantle structure. Travel-time uncertainty estimates are used in the process of associating seismic phases to events and to accurately calculate location uncertainty bounds (i.e. event location error ellipses). We improve on the current distance-dependent uncertainty parameterization for RSTT using a random effects model to estimate slowness (inverse velocity) uncertainty as a mean squared error for each model parameter. The random effects model separates the error between observed slowness and model predicted slowness into bias and random components. The path-specific travel-time uncertainty is calculated by integrating these mean squared errors along a seismic-phase ray path. We demonstrate that event location error ellipses computed for a 90% coverage ellipse metric (used by the Comprehensive Nuclear-Test-Ban Treaty Organization International Data Centre (IDC)), and using the path-specific travel-time uncertainty approach, are more representative (median 82.5% ellipse percentage) of true location error than error ellipses computed using distance-dependent travel-time uncertainties (median 70.1%). We also demonstrate measurable improvement in location uncertainties using the RSTT method compared to the current station correction approach used at the IDC (median 74.3% coverage ellipse).

58 GEOSCIENCES↗

Using HPTLC/DESI-MS for Peptide Identification in 1D Separations of Tryptic Protein Digests

Desorption electrospray ionization mass spectrometry was investigated as a method to detect and identify peptides from tryptic digests of cytochrome c and myoglobin separated on ProteoChrom HPTLC Silica gel 60 F254s plates and ProteoChrom HPTLC Cellulose sheets. Both full scan mass spectra and data-dependent tandem mass spectra were acquired in separate plate scans and used to identify peptide ions. Peptide distributions along the development lane were mapped for each separated protein digest. Signal levels ranged over several orders of magnitude. In general, highest signal levels were obtained for the peptides with the highest Rf values on a plate, while peptides with very low Rf values were often not detected. Sequence coverages for cytochrome c were 58% for the digest separated on the silica gel plate and 72% for the separation on the cellulose sheet; myoglobin sequence coverages were 62% and 68% on silica gel and cellulose, respectively. Weak correlations between peptide hydrophilicity and Rf values on the silica gel and cellulose plates were found, with more hydrophilic peptides having lower Rf values.

59 BASIC BIOLOGICAL SCIENCES↗

High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recanalization Results After Intracranial Stenting of Atherosclerotic Stenoses

The purpose of this investigation was to provide a detailed description of the angiographic results after stenting of high-grade intracranial stenosis using balloon-expandable stents. Forty consecutive patients with symptomatic atherosclerotic intracranial stenosis >50% received endovascular treatment by placement of balloon-expandable stents using the concept of slight underdilation and strict avoidance of overdilation. Intra-arterial digital subtraction angiography images before and after stenting in the same projection were reviewed for pre- and post-therapeutic measurement of the degree of stenosis and evaluation of morphologic criteria like plaque coverage, stent apposition, patency of side branches, and signs of dissection or vasospasm. Stenting decreased the mean percentage stenosis from 76.2 (WASID criteria) to 20.8%. Residual stenosis ranged from 0 to 55% with residual stenosis >50% in two of 40 cases. Technical success rate was 95%. There were no major vessel complications, but minor abnormalities like incomplete stent apposition (8/40) or plaque coverage (7/40), incomplete filling of side branches (13/40), and minor dissections after stenting (2/40) were seen. One case with incomplete stent apposition and two cases with side branch compromise were associated with clinical symptoms. In conclusion, intracranial stenting with slight underdilation avoided major vessel complication and created reliable luminal gain. Suboptimal recanalization results were frequently detected and may be the source of neurological complications in individual cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of Hepatic Arterial Branches to Simplify Hepatic Blood Flow Before Yttrium 90 Radioembolization: A Useful Technique in the Presence of Challenging Anatomy

Purpose: In the presence of variant hepatic arterial anatomy, obtaining whole-liver coverage with yttrium 90 (Y90) radioembolization may be challenging. The purpose of this study was to determine whether a technique whereby variant hepatic arterial branches are embolized and then Y90 is administered selectively into one remaining hepatic arterial branch results in whole-liver coverage and effective therapy. A retrospective comparison of treatment response was made between a group of patients who underwent this technique before Y90 administration and a group of patients who received standard Y90 administration as a single dose into the proper hepatic artery or in divided doses into the immediate hepatic artery branches. The rest of the workup and treatment were identical in both groups, including routine embolization of potential nonhepatic, nontarget vessels (e.g., the gastroduodenal artery). Methods: A total of 32 patients (mean age 56.9 years, range 39-77 years) treated with Y90 between June 2004 and March 2008 were analyzed. The primary malignancy was colorectal in 29, breast in 2, and cholangiocarcinoma in 1. Group 1 comprised 20 patients who had no alterations to their hepatic arterial supply. Group 2 comprised 12 cases who had undergone prior embolization of hepatic arterial branches before administration of Y90. The response to treatment was assessed by comparing standardized uptake value (SUV) on the pre- and postprocedure fludeoxyglucose positron emission tomographic studies of representative lesions within the right and left lobes of the liver. Results: In group 1, significant response (P < 0.001) was seen among right lobe lesions but not among left lobe lesions (P = 0.549). In group 2, there was a significant response among both right (P = 0.028) and left (P = 0.014) lobe lesions. No difference was found in the response of right lobe lesions (P = 0.726) between groups 1 and 2; a significantly greater response was found in group 2 compared to group 1 (P = 0.004) for left lobe lesions. Conclusion: Selective Y90 radioembolization after manipulation of hepatic arterial blood supply leads to an even distribution within the entire liver. When variations in hepatic arterial anatomy exist, this technique allows effective whole-liver radioembolization therapy from a single selective arterial injection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Caudate Lobe: The Blind Spot in Radioembolization or an Overlooked Opportunity?

PurposeThe caudate lobe (CL) is impartial to the functional left and right hemi-liver and has outspoken inter-individual differences in arterial vascularization. Unfortunately, this complexity is not specifically taken into account during radioembolization treatment (RE), potentially resulting in under- or overtreatment of the CL. The objective of this study was to evaluate the CL coverage in RE and determine the detection rate of the CL arteries on CT angiography during work-up.MethodsIn all consecutive patients who underwent RE treatment between May 2012–January 2015, {sup 99m}Tc-MAA SPECT/CT and posttreatment scans ({sup 90}Y-bremsstrahlung SPECT/CT, {sup 90}Y-PET/CT, or {sup 166}Ho-SPECT/CT) were reviewed for activity in the CL. Pretreatment CT angiographies were reviewed for the visibility of the CL arteries.ResultsEighty-two patients were treated. In 32/82 (39 %) the CL was involved. In 6/32 (19 %) patients, no activity was seen on the posttreatment scan in the CL, whereas in 40/50 (80 %) patients without CL tumor involvement, the CL was treated. {sup 99m}Tc-MAA SPECT/CT and final posttreatment scans were discordant in 16/78 (21 %). {sup 99m}Tc-MAA SPECT/CT had a positive and negative predictive value of 94 % and 46 %, respectively, for activity in the CL after RE. In untreated CLs, significant hypertrophy was observed with a median volume increase of 33 % (p = 0.02). CL arteries were seldom visible on the pretreatment CT; the identification rate was 12–17 %.ConclusionCurrently in RE treatments, targeting or sparing of the CL is highly erratic and independent of tumor involvement. Intentional treatment or bypassing of the CL seems worthwhile to either improve tumor coverage or enhance the functional liver remnant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing host DNA contamination in 16S rRNA gene surveys of anthozoan microbiomes using PNA clamps

Efforts to study the microbial communities associated with corals can be limited by inefficiencies in the sequencing process due to high levels of host amplification by universal bacterial 16S rRNA gene primers. Here, we develop an inexpensive peptide nucleic acid (PNA) clamp that binds to a target sequence of host DNA during PCR and blocks amplification. We then test the ability of this PNA clamp to mitigate host contamination and increase overall microbial sequence coverage on samples from three coral species: the gorgonians Eunicea flexuosa and Gorgonia ventalina, and the scleractinian Porites panamensis. The 20-bp PNA clamp was designed using DNA from E. flexuosa. Adding the PNA clamp during PCR increased the percentage of microbial reads in E. flexuosa samples more than 11-fold. Microbial community diversity was similar without- and with-PNA clamps, as were the relative frequencies of the ten most abundant ASVs (amplicon sequence variants), indicating that the clamps successfully blocked host DNA amplification while simultaneously increasing microbial DNA amplification proportionally across the most abundant taxa. The reduction of E. flexuosa DNA correlated with an increase in the abundance of rarer taxa. The clamp also increased the average percentage of microbial reads in another gorgonian, G. ventalina, by 8.6-fold without altering the microbial community beta diversity, and in a distantly related scleractinian coral, P. panamensis, by nearly double. The reduction of host contamination correlated with the number of nucleotide mismatches between the host amplicon and the PNA clamp. The PNA clamp costs as little as $0.48 per sample, making it an efficient and cost-effective solution to increase microbial sequence coverage for high-throughput sequencing of coral microbial communities.

16S rRNA gene sequencing↗

Isotope effects in methanol synthesis and the reactivity of copper formates on a Cu/SiO2 catalyst

Here we investigate isotope effects on the catalytic methanol synthesis reaction and the reactivity of copper-bound formate species in CO2-H2 atmospheres on Cu/SiO2 catalysts by simultaneous IR and MS measurements, both steady-state and transient. Studies of isotopic variants (H/D, 12C/13C) reveal that bidentate formate dominates the copper surface at steady state. The steady-state formate coverages of HCOO (in 6 bar 3:1 H2:CO2) and DCOO (in D2:CO2) are similar and the steady-state formate coverages in both systems decrease by ~80% from 350 K to 550 K. Over the temperature range 413K – 553K, the steady-state methanol synthesis rate shows a weak H/D isotope effect (1.05 ± 0.05) with somewhat higher activation energies in H2:CO2 (79 kJ/mole) than D2:CO2 (71 kJ/mole) over the range 473K-553K. The reverse water gas shift (RWGS) rates are higher than methanol synthesis and also shows a weak positive H/D isotope effect with higher activation energy for H2/CO2 than D2/CO2 (108 vs. and 102 kJ/mole). The reactivity of the resulting formate species in 6 bar H2, 6 bar D2 and 6 bar Ar is strongly dominated by decomposition back to CO2 and H2. H2 and D2 exposure compared to Ar do not enhance the formate decomposition rate. The decomposition profiles on the supported catalyst deviate from first order decay, indicating distributed surface reactivity. The average decomposition rates are similar to values previously reported on single crystals. The average activation energies for formate decomposition are 90 ± 17 kJ/mole for HCOO and 119 ± 11 kJ/mole for DCOO. By contrast to the catalytic reaction rates, the formate decomposition rate shows a strong H/D kinetic isotope effect (H/D ~ 8 at 413K), similar to previously observed values on Cu(110).

10 SYNTHETIC FUELS↗

Bioenergy Technologies in Long-Run Climate Change Mitigation: Results from the EMF-33 Study

Bioenergy is expected to play an important role in long-run climate change mitigation strategies as highlighted by many integrated assessment model (IAM) scenarios. These scenarios, however, also show a very wide range of results, with uncertainty about bioenergy conversion technology deployment and biomass feedstock supply. To date, the underlying differences in model assumptions and parameters for the range of results have not been conveyed. Here we explore the models and results of the 33rd study of the Stanford Energy Modeling Forum to elucidate and explore bioenergy technology specifications and constraints that underlie projected bioenergy outcomes. We first develop and report consistent bioenergy technology characterizations and modeling details. We evaluate the bioenergy technology specifications through a series of analyses—comparison with the literature, model intercomparison, and an assessment of bioenergy technology projected deployments. We find that bioenergy technology coverage and characterization varies substantially across models, spanning different conversion routes, carbon capture and storage opportunities, and technology deployment constraints. Still, the range of technology specification assumptions is largely in line with bottom-up engineering estimates. We then find that variation in bioenergy deployment across models cannot be understood from technology costs alone. Important additional determinants include biomass feedstock costs, the availability and costs of alternative mitigation options in and across end-uses, the availability of carbon dioxide removal possibilities, the speed with which large scale changes in the makeup of energy conversion facilities and integration can take place, and the relative demand for different energy services.

bioenergy↗

Optimization of electrode characteristics for the Br-2/H-2 redox flow cell

The Br-2/H-2 redox flow cell shows promise as a high-power, low-cost energy storage device. The effect of various aspects of material selection, processing, and assembly of electrodes on the operation, performance, and efficiency of the system is determined. In particular, (+) electrode thickness, cell compression, hydrogen pressure, and (-) electrode architecture are investigated. Increasing hydrogen pressure and depositing the (-) catalyst layer on the membrane instead of on the carbon paper backing layers have a large positive impact on performance, enabling a limiting current density above 2 A cm(-2) and a peak power density of 1.4 W cm(-2). Maximum energy efficiency of 79 % is achieved. In addition, the root cause of limiting-current behavior in this system is elucidated, where it is found that Br- reversibly adsorbs at the Pt (-) electrode for potentials exceeding a critical value, and the extent of Br- coverage is potential-dependent. This phenomenon limits maximum cell current density and must be addressed in system modeling and design. These findings are expected to lower system cost and enable higher efficiency.

Tucker, MC↗

New Tabu Algorithm for Positioning Mining Drillholes with Blocks Uncertainty

This paper proposes a new approach to the mining exploration drillholes positioning problem (DPP) that incorporates both geostatistical and optimization techniques. A metaheuristic was developed to solve the DPP taking into account an uncertainty index that quantifies the reliability of the current interpretation of the mineral deposit. The uncertainty index was calculated from multiple deposit realizations obtained by truncated Gaussian simulations conditional to the available drillholes samplings. A linear programming model was defined to select the subset of future drillholes that maximizes coverage of the uncertainty. A Tabu Search algorithm was developed to solve large instances of this set partitioning problem. The proposed Tabu Search algorithm is shown to provide good quality solutions approaching 95% of the optimal solution in a reasonable computing time, allowing close to optimal coverage of uncertainty for a fixed investment in drilling.

58 GEOSCIENCES↗

Millimeter-wave home area network prospect with cost-effective RoF links

The growth towards the millimeter-wave band in the home area networks (HAN) leads to high data rate transmission to satisfy the new user services. Unfortunately, the transmission coverage in this band is limited to short distances because of the strong air absorption and obstacles such as walls. The effort is then focused on the extension of the network coverage of the wireless link in this band. Solutions based on multiple connected access points to optical fibers are useful methods to ensure wireless connectivity to the entire home. For HAN applications, radio-over-fiber (RoF) using intensity modulation and direct detection technique is the mostly favorite technology for the transmission of a broadband wireless signal because dealing with a cost-effective solution. We investigate in this paper the performance of such RoF-wireless architecture with low-cost optoelectronic modules through the error vector magnitude (EVM) metric. The RoF links investigated are a directly modulated VCSEL with integrated photoreceiver module, an electroabsorption-modulated laser with PIN photodiode and a Mach–Zehnder Modulator with PIN photodiode. A simulation approach based on equivalent electrical circuit models of photonic components is developed in ADS (Advanced Design System) by using a co-simulation technique that combines both analog and digital signals. The downlink channel of the complete transmission system including wireless channel and frequency conversion circuits to millimeter-wave (mm-wave) band is studied by simulation. The obtained results of EVM show good performances of cost-effective links with QPSK and 16-QAM modulation over a dynamic range of 15 dB.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CSK hopping pattern model for visible light communication networks

This paper proposes a new channel access method for visible light communications. The transmitter uses the CSK hopping pattern mode to load data to the R, G, and B light-emitting diodes of LEDs and establishes the network access point (AP) of the LEDs for the illumination coverage area. The coordinator controls the work of each AP to ensure that it simultaneously uses different color patterns to distinguish its respective networks. When the receiver (mobile terminal) detects a particular color pattern in the illumination coverage area, it establishes a communication access network process with the AP that is transmitting the particular color pattern. The advantage of this method is that interference between adjacent APs can be avoided. In addition, due to the simplification of the access network, the proposed CSK hopping model can shorten delays in the terminal’s access network. Through modeling and simulation, it is found that this method can effectively support network power and reduce network delay. Moreover, the fairness and stability of terminals that access the network are improved to a certain extent.

42 ENGINEERING↗

IR-Spectroscopic Study on the Interface of Cu-Based Methanol Synthesis Catalysts: Evidence for the Formation of a ZnO Overlayer

Carbon monoxide was applied as probe molecule to compare the surface of a ZnO-containing (Cu/ZnO:Al) and a ZnO-free (Cu/MgO) methanol synthesis catalyst (copper content 70 atomic %) after reduction in hydrogen at 523 K by DRIFT spectroscopy. Nano-structured, mainly metallic copper was detected on the surface of the Cu/MgO catalyst. In contrast, the high energy of the main peak in the spectrum of CO adsorbed on reduced Cu/ZnO:Al (2125 cm -1 ) proves that metallic copper is largely absent on the surface of this catalyst. The band is assigned to Zn δ+ –CO. The presence of not completely reduced Cu δ+ –CO species cannot be excluded. The results are interpreted in terms of a partial coverage of the copper nano-particles in the Cu/ZnO:Al catalyst by a thin layer of metastable, defective zinc oxide. Minor contributions in the spectrum at 2090 and 2112 cm -1 due to nano-structured Cu 0 –CO and CO adsorbed on highly defective Cu 0 , respectively, indicate that the coverage of metallic copper is not complete.

36 MATERIALS SCIENCE↗

Tribological Properties of NiAl Matrix Composites Filled with Serpentine Powders

The unexplored tribological properties of NiAl matrix composites filled with serpentine powders are investigated using a reciprocating ball-on-disk configuration. Tribological test results reveal that increasing the serpentine concentration to some extent reduces the friction coefficients and wear rates of the composites. The best anti-friction and anti-wear performance is displayed by the NiAl matrix composite filled with 8 wt.% serpentine and 2 wt.% TiC (NAST). Microstructural analyses demonstrate that after adding serpentine, the self-lubricating films with different percentages of coverage form on the worn surfaces of the composites. A self-lubricating film with the highest percentage of coverage smears on the worn surface of NAST. This clearly suggests that serpentine can act as a new type of filler for NiAl matrix composites, whereas a combination of serpentine and TiC can enable serpentine to provide a full play to its excellent lubricating performance.

36 MATERIALS SCIENCE↗

Study of the Electrical and Diffusion Barrier Properties in Ultrathin Carbon Film-Coated Copper Microwires for Interconnects

Four specimen patterns with the microstructure of a microcopper wire are deposited on the Si-wafer substrate plus thermal oxide (SiO{sub 2}) film as the top layer. Each pattern was prepared to have two kinds of specimens, including with and without ultrathin carbon film between the copper wire and the top layer (SiO{sub 2}). The effect of carbon film on electrical properties is evaluated via the measurements of the I (current)–V (voltage) curve, sheet electrical resistance, current leakage, and its ratio and effective permittivity. A rapid thermal annealing (RTA) technique is provided as an economic and efficient method to grow the ultrathin carbon film rapidly as the interlayer. Appropriate choices of 900 °C and 3 min as the annealing temperature and time can produce ultrathin carbon film with nearly 100% coverage of the copper surface. The sheet resistance of specimen demonstrates the behavior exactly opposite to that of the carbon film coverage of wire surface. The combined effect of elevating the voltage and annealing temperature of the specimen with carbon film on the current leakage is much lower than that arising in the specimen without carbon film, so long as the carbon films operating at that temperature (between 350 and 500 °C) are still sustainable. The differences in current leakage and effective permittivity between these two kinds of specimen are significantly increased by raising the temperature. The intensity (IC) of copper diffusions into the SiO{sub 2} layer in the specimens with the carbon film demonstrates behavior similar to that of current leakage (CL). The IC and CL values for the temperatures ≦ 350 °C are much lower than those obtained at 500 °C.

36 MATERIALS SCIENCE↗