Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Characterizing the Two and Three DimensionalResolution of an Improved Aberration-corrected STEM

The successful development of third-order aberration correctors in transmission electron microscopy has seen aberration-corrected electron microscopes evolve from a specialist project, custom built at a small number of sites to a common instrument in many modern laboratories. Here we describe some initial results illustrating the two- and three- dimensional performance of an aberration corrected STEM with a prototype improved aberration corrector designed to also minimize fifth-order aberrations and a new, higher brightness gun. We demonstrate a resolution of 0.63 and detection of single dopant atoms with three-dimensional sensitivity.

47 OTHER INSTRUMENTATION↗

Behavior of Au Species in Au/Fe 2 O 3 Catalysts Characterized by Novel In Situ Heating Techniques and Aberration-Corrected STEM Imaging

The recent advent of a novel design of in situ heating technology for electron microscopes has permitted unprecedented control of elevated temperature studies of catalytic materials, particularly when coupled with the sub- ngstr m imaging performance of a modern aberration-corrected scanning transmission electron microscope (STEM). In using micro-electro-mechanical-systems (MEMS)-based Aduro heating chips from Protochips, Inc. (Raleigh, NC, USA) it allows nearly instantaneous heating and cooling of catalyst powders, while avoiding the effects of temperature ramping as experienced with standard heating stages. The heating technology also provides stable operation limited only by the inherent drift in the microscope stage, thus allowing full image resolution to be achieved even at elevated temperatures. Our study details the use of both the high X-Y spatial resolution in both dark-field and simultaneous bright-field imaging, along with the high resolution in Z (depth sectioning) provided by the large probe incidence semiangle in the aberration-corrected instrument, to characterize the evolution of microstructure in a commercial Au/Fe 2 O 3 water-gas shift catalyst during elevated temperature treatment. The phenomenon of Au diffusion to the surface of hematite support particles to form discrete crystalline Au nanoparticles in the 1-2 nm size range, after a prior leaching treatment to remove surface Au species has been characterized.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aberration-Corrected STEM Imaging Through Off-Site Remote Operation

Recent advances in aberration-corrected electron microscopy have allowed researchers to imagematerials at sub-Ångström resolution. Many of these modern instruments are designed to beoperated from separate 'control' rooms, removing the effect of the operator on the instrument’sphysical environment. This capability also allows operation from suitable workstations, overinternet connections, from literally anywhere in the world [1]. Researchers at the University ofTexas at Austin (UTA) have collaborated with Oak Ridge National Laboratory (ORNL) and JEOLLtd. to routinely conduct research sessions in which high-resolution images and X-raymicroanalytical data are acquired during after-hours research sessions, utilizing the JEOL 2200FSaberration-corrected STEM/TEM at ORNL from their lab in Austin. Details of the remote operationare presented here.

36 MATERIALS SCIENCE↗

XPS on Li-Battery-Related Compounds: Analysis of Inorganic SEI Phases and a Methodology for Charge Correction

Accurate identification of chemical phases associated with the electrode and solid-electrolyte interphase (SEI) is critical for understanding and controlling interfacial degradation mechanisms in lithium-containing battery systems. To study these critical battery materials and interfaces X-ray photoelectron spectroscopy (XPS) is a widely used technique that provides quantitative chemical insights. However, due to the fact that a majority of chemical phases relevant to battery interfaces are poor electronic conductors, phase identification that relies primarily on absolute XPS core-level binding-energies (BEs) can be problematic. Charging during XPS measurements leads to BE shifts that can be difficult to correct. These difficulties are often exacerbated by the coexistence of multiple Li-containing phases in the SEI with overlapping XPS core levels. To facilitate accurate phase identification of battery-relevant phases (and electronically insulating phases in general), we propose a straightforward approach for removing charging effects from XPS data sets. We apply this approach to XPS data sets acquired from six battery-relevant inorganic phases including lithium metal (Li0), lithium oxide (Li 2 O), lithium peroxide (Li 2 O 2 ), lithium hydroxide (LiOH), lithium carbonate (Li 2 CO 3 ), and lithium nitride (Li 3 N). Specifically, we demonstrate that BE separations between core levels present in a particular phase (e.g., BE separation between the O 1s and Li 1s core levels in Li 2 O) provide an additional constraint that can significantly improve reliability of phase identification. For phases like Li 2 O 2 and LiOH where the Li-to-O ratios and BE separations are nearly identical, X-ray excited valence-band spectra can provide additional clues that facilitate accurate phase identification. To accurately identity the phases in this study, we show that in situ growth of Li 2 O on Li 0 provides a means for determining absolute core-level positions, where all charging effects can be accurately removed. Finally, as an exemplary case we apply the charge-correction methodology to XPS data acquired from a symmetric cell based on a Li 2 S-P 2 S 5 solid electrolyte. This analysis demonstrates that accurately accounting for XPS BE shifts as a function of current-bias conditions can provide a direct probe of ionic conductivities associated with battery materials.

25 ENERGY STORAGE↗

Ni and Co Incorporation in Forsterite: A Density Functional Theory Study with Hubbard Correction

Ni and Co are critical elements for the world economy and modern technologies. Mafic and ultramafic deposits represent low-grade yet abundant alternatives to traditional Ni and Co ores. Here, in this work, density functional theory (DFT) with the Hubbard U correction (DFT+U) was used to simulate the incorporation of Ni and Co in forsterite (Mg 2 SiO 4 ), the Mg endmember of olivine, a common mineral in mafic and ultramafic rocks. Hubbard U terms for Ni and Co were parametrized using a series of oxide, hydroxide, carbonate, silicate, and sulfide minerals relevant to extraction and recovery of Ni and Co from mafic and ultramafic deposits. Electronic, energetic, magnetic, and structural properties were considered in the parametrization. For each of Ni and Co, an effective Hubbard correction (U eff ) value that optimized agreement with either experimental data or a hybrid exchange-correlation functional for all of the minerals considered is reported. DFT+U ab initio molecular dynamics (AIMD) simulations of Ni and Co incorporated into the M1 and M2 octahedral sites of forsterite were then performed. Ni and Co substitution in the M1 site was more energetically favorable than substitution in the M2 site, in agreement with published partition coefficients. AIMD trajectories were used to compute extended X-ray absorption fine structure (EXAFS) spectra of Ni in the M1 and M2 sites for direct fitting to a published experimental spectrum of Ni in a natural San Carlos olivine sample. The results of the fit indicated that ordering of Ni in the M1 site was not as strong at the low Ni concentrations relevant to mafic and ultramafic silicate minerals as that at the higher concentrations of the Ni-Mg olivine solid solutions studied to date.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic Resolution Cryogenic 4D-STEM Imaging via Robust Distortion Correction

Cryogenic four-dimensional scanning transmission electron microscopy (4D-STEM) imaging is a useful technique for studying quantum materials and their interfaces by simultaneously probing charge, lattice, spin, and chemistry on the atomic scale with the sample held at temperatures ranging from room to cryogenic. However, its applications are currently limited by the instabilities of cryo-stages and electronics. To overcome this challenge, we develop an algorithm to effectively correct the complex distortions present in atomic resolution cryogenic 4D-STEM data sets. This method uses nonrigid registration to identify localized distortions in a 4D-STEM and relate them to an undistorted experimental STEM image, followed by a series of affine transformations for distortion corrections. This method allows a minimum loss of information in both reciprocal and real spaces, enabling the reconstruction of sample information from 4D-STEM data sets. This method is computationally cheap, fast, and applicable for on-the-fly data analysis in future in situ cryogenic 4D-STEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

QCD Corrections to Heavy Quarkonium Production

I discuss J/{psi} and {upsilon} production at the Tevatron. Working in the framework of NRQCD, I review the current theoretical status. Motivated by the polarization puzzle at the Tevatron, I present the brand-new computation of higher-order {alpha}{sub s} corrections to the color-singlet production and discuss the impact of these corrections both on the differential cross section and on the polarization of the quarkonium state. I finally comment on the relative importance of the various transitions that feed quarkonium hadroproduction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correction of spherical aberration for an electrostatic gridded lens

Two methods to correct spherical aberration in electrostatic gridded lenses have been studied using ray-tracing simulations. Both methods are based on modifying the electrostatic field on the radial periphery of the lens. In the simplest case, the modification is done by extending the grid support axially. In the second method, the electric field on a radial periphery of the lens is modified by applying optimum voltage on an isolated correcting electrode. It is demonstrated that, for a given focal length, the voltage on this lens can be optimized for minimum aberration, and also that these lenses reduce the emittance growth of the ion beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Corrected direct force balance method for atomic force microscopy lateral force calibration

This paper reports corrections and improvements of the previously reported direct force balance method (DFBM) developed for lateral calibration of atomic force microscopy. The DFBM method employs the lateral force signal obtained during a force-distance measurement on a sloped surface and relates this signal to the applied load and the slope of the surface to determine the lateral calibration factor. In the original publication [Rev. Sci. Instrum. 77, 043903 (2006)], the tip-substrate contact was assumed to be pinned at the point of contact, i.e., no slip along the slope. In control experiments, the tip was found to slide along the slope during force-distance curve measurement. This paper presents the correct force balance for lateral force calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Target Mass Corrections and Beyond

I examine the uncertainty of perturbative Quantum Chromodynamics (QCD) factorization for (un)polarized hadron structure functions in deep inelastic scattering at a large value of the Bjorken variable x{sub B} The focus will be on Target Mass Corrections and Jet Mass Corrections in the collinear factorization framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SUSY-QCD corrections to dark matter annihilations

We present full QCD and SUSY-QCD corrections to neutralino pair annihilation into quark-antiquark pairs. We show results and numerically evaluate their impact on the neutralino annihilation cross section and the relic density in scenarios with non-universal gaugino masses. By comparing to the relic density obtained from a pure leading order calculation, we demonstrate that the corrections strongly influence the extraction of SUSY mass parameters from cosmological data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NLO QCD corrections to associate production of squarks and charginos at LHC

In this talk, we present our calculations for the next-to-leading order(NLO) QCD corrections to the cross sections (CS) of the associate production processes pp->gq->q-tilde{sub i}chi-tilde{sub j}{sup +}-+X with q = (u,d) in the constrained minimal supersymmetric standard model in the CERN LHC experiments. The NLO QCD corrections can in general provide a 30-40% enhancement to the corresponding cross sections, and significantly reduce the dependence of the total cross section on the renormalization and factorization scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impurity temperature correction factors for the transmission grating spectrometer in the TJ-II stellarator

Impurity ion temperature and velocity profiles are obtained across plasmas in the TJ-II stellarator by performing charge-exchange recombination spectroscopy with a diagnostic neutral beam injector. For this, a tridirectional (toroidal plus two poloidal opposing views) multichannel spectroscopic diagnostic, incorporating 12-way fiber arrays, a compact f/1.8 spectrograph, and a back-illuminated CCD, permits Doppler line shifts and widths (of the C VI line at 529.05 nm) to be determined with 1-2 cm spatial resolution. For good photon counting statistics under Li-coated wall conditions, 600 {mu}m diameter fibers collect and transmit light to curved 100 {mu}m wide input slits. When calibrated with a neon pencil lamp this entrance slit width results in a non-Gaussian instrumental function that, if not handled correctly, can result in systematically underestimated impurity temperatures. Here we develop and present correction factors for this effect for a range of conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting hot-wire measurements of stream-wise turbulence intensity in boundary layers

The current experimental activity aimed at resolving the scaling of stream-wise turbulence intensity profiles uu{sup +}(y{sup +}) with Reynolds number in turbulent flat plate boundary layers has brought the largely unresolved issue of correcting systematic errors in hot-wire measurements of uu{sup +}(y{sup +}) into focus. Here, a heuristic scheme is proposed to generate unique uu{sup +}(y{sup +};Re{sub {delta}{sup *}}) profiles from data obtained with single hot wires of widely different length, aspect ratio and construction over a large Reynolds number range of 4000 < or approx. Re{sub {delta}{sup *}} < or approx. 50 000. A comparison with LDA data and other checks suggest that the present correction scheme produces uu{sup +}(y{sup +};Re{sub {delta}{sup *}}) profiles close to the (unknown) true profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis and improvements of fringe jump corrections by electronics on the JET tokamak far infrared interferometer

For the Tore Supra interferometer phase measurements, an electronics had been developed electronics using field programmable gate array processors. The embedded algorithm can correct the fringe jumps. For comparison, the electronics ran at JET during the 2009 campaign. The first analysis concluded that the electronics was not correcting all the fringe jumps. An analysis of the failures led to improvements in the algorithm, which was tested during the rest of the campaign. In this article, we evaluate the increases in the performance. From the analysis of the remaining faults, further improvements are discussed for designing future boards that are foreseen for JET using the second wavelength and the Cotton-Mouton effect information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron cyclotron current drive modelling with parallel momentum correction for tokamaks and stellarators

The electron cyclotron current drive (ECCD) is described by the solution of a drift-kinetic equation (DKE) with the quasi-linear heating term which is highly localised in phase space. Within the adjoint approach, an equivalent DKE must be solved without this highly localised source, and the ECCD is described by a straightforward convolution in phase space. The parallel momentum correction technique [Maassberg et al., Phys. Plasmas 16, 072504 (2009)] reduces the problem to the solution of a simplified mono-energetic DKE. The mono-energetic distribution functions are calculated by the DKES code [W. I. van Rij and S. P. Hirshman, Phys. Fluids B 1, 563 (1989)]. Parallel momentum correction, requiring only an energy-dependent weighting factor, is applied to these distribution functions allowing for the direct estimation of the EC-driven current. For small yet finite collisionalities, a rather simple model for ECCD is presented. In this approach, the symmetric portion of the electron distribution function with respect to v{sub Parallel-To} (the Ware pinch contribution) is neglected and an 'off-set' only in the passing particle domain adds to the collisionless (anti-symmetric) distribution function. For this approximation, only the mono-energetic parallel conductivity coefficient as function of the collisionality is needed. The impact of small yet finite collisionalities on ECCD is shown for X2- and O2-scenarios at W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination and correction of distortions and systematic errors in low-energy electron diffraction

We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of radiation beams used to determinate the correction factor for a CyberKnife® unit reference field using ionization chambers

This paper aimed to characterize a 6 MV x-ray beam from a Varian® iX linear accelerator in order to obtain the correction factors needed by the IAEA/AAPM new formalism{sup 1}. The experiments were performed in a liquid water phantom under different irradiation conditions: a) Calibration of the reference field of 10 cm × 10 cm at 90 cm SSD and 10 cm depth was carried out according to the TRS-398 protocol using three ionization chambers (IC) calibrated in different reference laboratory and b) Measurement of the absorbed dose rate at 70 cm SSD and 10 cm depth in a 10 cm × 10 cm and 5.4 cm × 5.4 cm fields was obtained in order to simulate the CyberKnife® conditions where maximum distance between the source and the detector is equal to 80 cm and the maximum field size is 6 cm diameter. Depending where the IC was calibrated, differences between 0.16% and 2.24% in the absorbed dose rate measured in the 10 cm × 10 cm field at 90 cm SSD were observed, while for the measurements at 70 cm SSD, differences between 1.27% and 3.88% were obtained. For the 5.4 cm × 5.4 cm field, the absorbed dose measured with the three ICs varies between 1.37% and 3.52%. The increase in the difference on the absorbed dose when decreasing the SSD could possibly be associated to scattering radiation generated from the collimators and/or the energy dependence of the ionization chambers to low-energy radiation. The results presented in this work suggest the importance of simulating the CyberKnife® conditions using other linear accelerator for obtaining the correction factors as proposed by the IAEA/AAPM new formalism in order to measure the absorbed dose with acceptable accuracy.

43 PARTICLE ACCELERATORS↗