Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Iodine Removal from Carbonate-Containing Alkaline Liquids Using Strong Base Resins, Hybrid Resins, and Silver Precipitation

The ability of several material types to remove aqueous iodine from a mildly alkaline, carbonate-rich nuclear waste stream was evaluated: strong base anion exchange resins (SBAR), hybrid resins, Ag-containing materials and Bi-containing hybrid resins. A combination of batch testing and flow through column testing were used in the evaluation. In batch testing, hybrid resins CHM-20, SIR-110-CE and RTBI were shown to have high efficiency for the removal of both iodide and iodate simultaneously, while Ag-containing materials and SBAR demonstrated high capacity for iodide removal. One example of each material type (CHM-20, A532E and Ionex 400) were further evaluated for their sorption isotherms and column performance. The Langmuir isotherm, or a Langmuir-Freundlich hybrid isotherm, best described the sorption of iodide to the CHM-20 hybrid resin and Purolite A532E. The Freundlich isotherm best described the uptake of iodate to CHM-20 and A532E and for both iodide and iodate to the Ag-containing Ionex-400. In column testing the Purolite A532E had exceptional performance for overall iodide removal. With the capacity demonstrated the A532E resin would exceed Class C waste classification before breakthrough initiated, and column change outs in processing would be dictated by eventual waste classification, not breakthrough. The Ionex 400, a Ag-zeolite, was observed to degrade over time in the column in the mild alkaline conditions whereas the hybrid CHM-20 was limited in the single pass through design and would be best suited for applications where iodide and iodate are present and recirculation of the column effluent is feasible. Here this work highlights the feasibility of commercially available materials to separate radioiodine from liquid environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization and Testing of Amidoxime-Based Adsorbent Materials to Extract Uranium from Natural Seawater

Extraction of uranium (U) from seawater for use as a nuclear fuel is a significant challenge due to the low concentration of U in seawater (~3.3 ppb) and difficulties to selectively extract U from the background of major and trace elements in seawater. The Pacific Northwest National Laboratory (PNNL)’s Marine Sciences Laboratory (MSL) has been serving as a marine test site for determining performance characteristics (adsorption capacity, adsorption kinetics, and selectivity) of novel amidoxime-based polymeric adsorbents developed at Oak Ridge National Laboratory (ORNL) under natural seawater exposure conditions. This manuscript describes the performance of three formulations (38H, AF1, AI8) of amidoxime-based polymeric adsorbents produced at ORNL in MSL’s ambient seawater testing facility. The adsorbents were produced in two forms, fibrous material (40-100 mg samples) and braided material (5-10 g samples), and exposed to natural seawater using flow-through columns and recirculating flumes. All three formulations demonstrated high 56 day uranium adsorption capacity (>3 g U/kg adsorbent). The AF1 formulation had the best uranium adsorption performance, with a 56 day capacity of 3.9 g U/ kg adsorbent, a saturation capacity of 5.4 g U/kg adsorbent, and ~25 days half-saturation time. The two exposure methods, flowthrough columns and flumes, were demonstrated to produce similar performance results, providing confidence that the test methods were reliable, that scaling up from 10’s of mg quantities of exposure in flow-through columns to gram quantities in flumes produced similar results, and confirm that the manufacturing process produces a homogeneous adsorbent. Adsorption kinetics appear to be element specific, with half-saturation times ranging from minutes for the major cations in seawater, to 8-10 weeks for V and Fe. Reducing the exposure time provides a potential pathway to improve the adsorption capacity of U by reducing the V/U ratio on the adsorbent.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Influence of Current Velocity on Uranium Adsorption from Seawater Using an Amidoxime-Based Polymer Fiber Adsorbent

Passive adsorption using amidoxime-based polymeric adsorbents is being developed for uranium recovery from seawater. The local oceanic current velocity where the adsorbent is deployed is a key variable in determining locations that will maximize uranium adsorption rates. Two independent experimental approaches using flow-through columns and recirculating flumes were used to assess the influence of linear velocity on uranium uptake kinetics by the adsorbent. Little to no difference was observed in the uranium adsorption rate vs. linear velocity for seawater exposure in flow-through columns. In contrast, adsorption results from seawater exposure in a recirculating flume showed a nearly linear trend with current velocity. The difference in adsorbent performance between columns and flume can be attributed to (i) flow resistance provided by the adsorbent braid in the flume and (ii) enhancement in braid movement (fluttering) with increasing linear velocity.

adsorption capacity↗

Chromium Isotope Fractionation During Reduction of Cr(VI) Under Saturated Flow Conditions

Chromium isotopes are potentially useful indicators of Cr(VI) reduction reactions in groundwater flow systems; however, the influence of transport on Cr isotope fractionation has not been fully examined. Laboratory batch and column experiments were conducted to evaluate isotopic fractionation of Cr during Cr(VI) reduction under both static and controlled flow conditions. Organic carbon was used to reduce Cr(VI) in simulated groundwater containing 20 mg L{sup -1} Cr(VI) in both batch and column experiments. Isotope measurements were performed on dissolved Cr on samples from the batch experiments, and on effluent and profile samples from the column experiment. Analysis of the residual solid-phase materials by scanning electron microscopy (SEM) and by X-ray absorption near edge structure (XANES) spectroscopy confirmed association of Cr(III) with organic carbon in the column solids. Decreases in dissolved Cr(VI) concentrations were coupled with increases in {delta}{sup 53}Cr, indicating that Cr isotope enrichment occurred during reduction of Cr(VI). The {delta}{sup 53}Cr data from the column experiment was fit by linear regression yielding a fractionation factor ({alpha}) of 0.9979, whereas the batch experiments exhibited Rayleigh-type isotope fractionation ({alpha} = 0.9965). The linear characteristic of the column {delta}{sup 53}Cr data may reflect the contribution of transport on Cr isotope fractionation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An Inorganic Microsphere Composite for the Selective Removal of Cesium 137 from Acidic Nuclear Waste Solutions - Parts 1 and 2

A new inorganic ion exchange composite for removing radioactive cesium from acidic waste streams has been developed. The new material consists of ammonium molybdophosphate, (NH4)3P(Mo3O10)4•3H2O (AMP), synthesized within hollow aluminosilicate microspheres (AMP-C), which are produced as a by-product from coal combustion. The selective cesium exchange capacity of this inorganic composite was evaluated in bench-scale column tests using simulated sodium bearing waste solution as a surrogate for the acidic tank waste currently stored at the Idaho National Laboratory (INL). Total cesium loading on the columns at saturation agreed very well with equilibrium values predicted from isotherm experiments performed previously. A numerical algorithm for solving the governing partial differential equations (PDE) for cesium uptake was developed using the intraparticle mass transfer coefficient obtained from previous batch kinetic experiments. Solutions to the governing equations were generated to obtain the cesium concentration at the column effluent as a function of throughput volume using the same conditions as those used for the actual column experiments. The numerical solutions of the PDE fit the column break through data quite well for all the experimental conditions in the study. The model should therefore provide a reliable prediction of column performance at larger scales. A new inorganic ion exchange composite consisting of ammonium molybdophosphate, (NH4)3P(Mo3O10)4•3H2O (AMP), synthesized within hollow aluminosilicate microspheres (AMP-C) has been developed. Two different batches of the sorbent were produced resulting in 20% and 25% AMP loading for two and three loading cycles, respectively. The selective cesium exchange capacity of this inorganic composite was evaluated using simulated sodium bearing waste solution as a surrogate for the acidic tank waste currently stored at the Idaho National Laboratory (INL). Equilibrium isotherms obtained from these experiments were very favorable for cesium uptake and indicated maximum cesium loading of approximately 9 % by weight of dry AMP. Batch kinetic experiments were also performed to obtain the necessary data to estimate the effective diffusion coefficient for cesium in the sorbent particle. These experiments resulted in effective intraparticle cesium diffusivity coefficients of 4.99 x 10-8 cm2/min and 4.72 x 10-8 cm2/min for the 20% and 25 % AMP-C material, respectively.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

METAL-ION ABSORPTION IN CONDUCTIVELY EVAPORATING CLOUDS

We present computations of the ionization structure and metal-absorption properties of thermally conductive interface layers that surround evaporating warm spherical clouds embedded in a hot medium. We rely on the analytical steady-state formalism of Dalton and Balbus to calculate the temperature profile in the evaporating gas, and we explicitly solve the time-dependent ionization equations for H, He, C, N, O, Si, and S in the conductive interface. We include photoionization by an external field. We estimate how departures from equilibrium ionization affect the resonance-line cooling efficiencies in the evaporating gas, and determine the conditions for which radiative losses may be neglected in the solution for the evaporation dynamics and temperature profile. Our results indicate that nonequilibrium cooling significantly increases the value of the saturation parameter {sigma}{sub 0} at which radiative losses begin to affect the flow dynamics. As applications, we calculate the ion fractions and projected column densities arising in the evaporating layers surrounding dwarf-galaxy-scale objects that are also photoionized by metagalactic radiation. We compare our results to the UV metal-absorption column densities observed in local highly ionized metal absorbers, located in the Galactic corona or intergalactic medium. Conductive interfaces significantly enhance the formation of high ions such as C{sup 3+}, N{sup 4+}, and O{sup 5+} relative to purely photoionized clouds, especially for clouds embedded in a high-pressure corona. However, the enhanced columns are still too low to account for the O VI columns ({approx}10{sup 14} cm{sup -2}) observed in the local high-velocity metal-ion absorbers. We find that column densities larger than {approx}10{sup 13} cm{sup -2} cannot be produced in evaporating clouds. Our results do support the conclusion of Savage and Lehner that absorption due to evaporating O VI likely occurs in the local interstellar medium, with characteristic columns of {approx}10{sup 13} cm{sup -2}.

79 ASTRONOMY AND ASTROPHYSICS↗

HELIUM IN NATAL H II REGIONS: THE ORIGIN OF THE X-RAY ABSORPTION IN GAMMA-RAY BURST AFTERGLOWS

Soft X-ray absorption in excess of Galactic is observed in the afterglows of most gamma-ray bursts (GRBs), but the correct solution to its origin has not been arrived at after more than a decade of work, preventing its use as a powerful diagnostic tool. We resolve this long-standing problem and find that absorption by He in the GRB's host H II region is responsible for most of the absorption. We show that the X-ray absorbing column density (N{sub H{sub X}}) is correlated with both the neutral gas column density and with the optical afterglow's dust extinction (A{sub V} ). This correlation explains the connection between dark bursts and bursts with high N{sub H{sub X}} values. From these correlations, we exclude an origin of the X-ray absorption which is not related to the host galaxy, i.e., the intergalactic medium or intervening absorbers are not responsible. We find that the correlation with the dust column has a strong redshift evolution, whereas the correlation with the neutral gas does not. From this, we conclude that the column density of the X-ray absorption is correlated with the total gas column density in the host galaxy rather than the metal column density, in spite of the fact that X-ray absorption is typically dominated by metals. The strong redshift evolution of N{sub H{sub X}}/A{sub V} is thus a reflection of the cosmic metallicity evolution of star-forming galaxies and we find it to be consistent with measurements of the redshift evolution of metallicities for GRB host galaxies. We conclude that the absorption of X-rays in GRB afterglows is caused by He in the H II region hosting the GRB. While dust is destroyed and metals are stripped of all of their electrons by the GRB to great distances, the abundance of He saturates the He-ionizing UV continuum much closer to the GRB, allowing it to remain in the neutral or singly-ionized state. Helium X-ray absorption explains the correlation with total gas, the lack of strong evolution with redshift, as well as the absence of dust, metal or hydrogen absorption features in the optical-UV spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

THE NATURE OF DAMPED LYMAN-α AND Mg II ABSORBERS EXPLORED THROUGH THEIR DUST CONTENTS

We estimate the abundance of dust in damped Lyman-α absorbers (DLAs) by statistically measuring the excess reddening they induce on their background quasars. We detect systematic reddening behind DLAs consistent with the SMC-type reddening curve and inconsistent with the Milky Way type. We find that the derived dust-to-gas ratio is, on average, inversely proportional to the column density of neutral hydrogen, implying that the amount of dust is constant, regardless of the column density of hydrogen. It means that the average metallicity is inversely proportional to the column density of hydrogen, unless the average dust-to-metal ratio varies with the hydrogen column density. This indicates that the prime origin of metals seen in DLAs is not by in situ star formation, with which Z∼N{sub H} {sub I}{sup +0.4} is expected from the empirical star formation law, contrary to our observation. We interpret the metals observed in absorbers to be deposited dominantly from nearby galaxies by galactic winds ubiquitous in intergalactic space. When extrapolating the relation between dust-to-gas ratio and H I column density to lower column density, we find a value that is consistent with what is observed for Mg II absorbers.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral induced polarization monitoring of induced calcite precipitation in subsurface sediments

Co-precipitation of contaminants within the crystalline structure of calcite is a promising natural attenuation or remedial technology being considered at contaminated sites. We explore the sensitivity of the spectral induced polarization (SIP) method to induced calcite precipitation in natural sediments as a path forward to non-invasively monitor these sites. We performed time-lapse column experiments using phased (I-IV) injections over 40 days on natural sediments from the Hanford Site (Washington State, USA). In the phased injections, abiotic calcite precipitation was induced and confirmed to have occurred. Previous work in glass beads and homogeneous sand was limited to high frequency detection of calcite, however in this work we observed the development of two polarization mechanisms, one at high frequency (>100 Hz) and one at low frequency (< 100 Hz). Based on the characteristic frequencies from the SIP high and low frequency regimes, characteristic length scales (L) were computed where the adsorption mode of Na+ versus Ca2+ was compared by using diffusion coefficients corresponding to Na+ versus an arithmetically averaged value for Na+ and Ca2+. Using the diffusion coefficient of Na+, the high frequency L was found to correlate well with the size of the calcite crystals. The low frequency L correlated well with the individual natural sediment grain sizes within the columns. During late experimental times (day 36 and 40), the characteristic low frequency in two of the experimental columns shifted to lower frequencies (<0.001 Hz) which may signify SIP sensitivity of the formed calcite with the sediment grains. In field applications, the development of a low frequency polarization length scale to monitor calcite precipitation is promising for field monitoring applications, however further laboratory work needs to be performed to examine the SIP sensitivity of calcite formation in the presence of to natural sediments

calcium carbonate, calcite, precipitation, spectra↗

Direct measurement of electron channeling in a crystal using scanning transmission electron microscopy

Self-focusing of an atomic-scale high-energy electron wave packet by channeling along a zone axis in crystalline silicon is directly measured by scanning transmission electron microscopy using thin epitaxial SrTiO{sub 3}(100) islands grown on Si(100) as test objects. As the electron probe propagates down a silicon atom column, it is progressively focused onto the column, resulting in a fourfold increase in the scattered signal at the channeling maximum. This results in an enhancement of the visibility of the SrTiO{sub 3} islands, which is lost if the sample is flipped upside down and the channeling occurs only after the probe scatters off the SrTiO{sub 3} layer. The evolution of the probe wave function calculated by the multislice method accurately predicts the trends in the channeling signal on an absolute thickness scale. We find that while electron channeling enhances the visibility of on-column atoms, it suppresses the contribution from off-column atoms. It can therefore be used as a filter to selectively image the atoms that are most aligned with the atomic columns of the substrate. By using this technique, coherent islands can be distinguished from relaxed islands. For SrTiO{sub 3} films formed in a topotactic reaction on Si(100), we show that only {approx}55% of the SrTiO{sub 3} is aligned with the Si atom columns. The fraction of coherent SrTiO{sub 3} islands on Si(100) can be increased by choosing growth conditions away from equilibrium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Viral and bacterial community responses to stimulated Fe(III)–bioreduction during simulated subsurface bioremediation

The delivery of fermentable substrate(s) to subsurface environments stimulates Fe(III)–bioreduction and achieves detoxification of organic/inorganic contaminants. Although, much research has been conducted on the microbiology of such engineered systems at lab and field scales, little attention has been given to the phage–host interactions and virus community dynamics in these environments. The objective was to determine the responses of soil bacterial communities and viral assemblages to stimulated anaerobic Fe(III)–bioreduction following electron donor (e.g. acetate) addition. Microbial communities, including viral assemblages, were investigated after 60 days of Fe(III)–bioreduction in laboratory–scale columns continuously fed with acetate–amended artificial groundwater. Viral abundances were greatest in the influent section and decreased along the flow path. Acetate availability was important in influencing bacterial diversity, microbial interactions and viral abundance and community composition. The impact of acetate addition was most evident in the influent section of the columns. The increased relative abundance of Fe(III)–reducing bacteria coincided with an increase in viral abundance in areas of the columns exhibiting the most Fe(III) reduction. In conclusion, the genetic composition of viruses in these column sections also differed from the control column and distal sections of acetate–treated columns suggesting viral communities responded to biostimulated Fe(III)–bioreduction.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-I-19: Optimization of Low Contrast Detectability Across Two CT Manufacturers

Purpose: Our goal was to evaluate low contrast detectability (LCD) for abdominal CT protocols across two CT scanner manufacturers, while producing a similar noise texture and CTDIvol for acquired images. Methods: A CIRS tissue equivalent LCD phantom containing three columns of 7 spherical targets, ranging from 10 mm to 2.4 mm, that are 5, 10, and 20 HU below the background matrix (HUBB) was scanned using two a GE HD750 64 slice scanner and a Siemens Somatom Definition AS 64 slice scanner. Protocols were designed to deliver a CTDIvol of 12.26 mGy and images were reconstructed with FBP, ASIR and Sapphire. Comparisons were made with those algorithms that had matching noise power spectrum peaks (NPS). NPS information was extracted from a previously published article that matched NPS peak frequencies across manufacturers by calculating the NPS from uniform phantom images reconstructed with several IR algorithms. Results: The minimum detectable lesion size in the 20 HUBB and 10 HUBB column was 6.3 mm, and 10 mm in the 5 HUBB column for the GE HD 750 scanner. The minimum detectable lesion size in the 20 HUBB column was 4.8 mm, in the 10 HUBB column, 9.5 mm, and the 5 HUBB column, 10 mm for the Siemens Somatom Definition AS. Conclusion: Reducing radiation dose while improving or maintaining LCD is possible with application of IR. However, there are several different IR algorithms, with each generating a different resolution and noise texture. In multi-manufacturer settings, matching only the CTDIvol between manufacturers may Result in a loss of clinically relevant information.

60 APPLIED LIFE SCIENCES↗

Parameterization and analysis of 3-D radiative transfer in clouds

This report provides a summary of major accomplishments from the project. The project examines the impact of radiative interactions between neighboring atmospheric columns, for example clouds scattering extra sunlight toward nearby clear areas. While most current cloud models don't consider these interactions and instead treat sunlight in each atmospheric column separately, the resulting uncertainties have remained unknown. This project has provided the first estimates on the way average solar heating is affected by interactions between nearby columns. These estimates have been obtained by combining several years of cloud observations at three DOE Atmospheric Radiation Measurement (ARM) Climate Research Facility sites (in Alaska, Oklahoma, and Papua New Guinea) with simulations of solar radiation around the observed clouds. The importance of radiative interactions between atmospheric columns was evaluated by contrasting simulations that included the interactions with those that did not. This study provides lower-bound estimates for radiative interactions: It cannot consider interactions in cross-wind direction, because it uses two-dimensional vertical cross-sections through clouds that were observed by instruments looking straight up as clouds drifted aloft. Data from new DOE scanning radars will allow future radiative studies to consider the full three-dimensional nature of radiative processes. The results reveal that two-dimensional radiative interactions increase overall day-and-night average solar heating by about 0.3, 1.2, and 4.1 Watts per meter square at the three sites, respectively. This increase grows further if one considers that most large-domain cloud simulations have resolutions that cannot specify small-scale cloud variability. For example, the increases in solar heating mentioned above roughly double for a fairly typical model resolution of 1 km. The study also examined the factors that shape radiative interactions between atmospheric columns and found that local effects were often much larger than the overall values mentioned above, and were especially large for high sun and near convective clouds such as cumulus. The study also found that statistical methods such as neural networks appear promising for enabling cloud models to consider radiative interactions between nearby atmospheric columns. Finally, through collaboration with German scientists, the project found that new methods (especially one called stepwise kriging) show great promise in filling gaps between cloud radar scans. If applied to data from the new DOE scanning cloud radars, these methods can yield large, continuous three-dimensional cloud structures for future radiative simulations.

58 GEOSCIENCES↗

Development of a Novel Gas Pressurized Stripping Process-Based Technology for CO₂ Capture from Post-Combustion Flue Gases

A novel Gas Pressurized Stripping (GPS) post-combustion carbon capture (PCC) process has been developed by Carbon Capture Scientific, LLC, CONSOL Energy Inc., Nexant Inc., and Western Kentucky University in this bench-scale project. The GPS-based process presents a unique approach that uses a gas pressurized technology for CO₂ stripping at an elevated pressure to overcome the energy use and other disadvantages associated with the benchmark monoethanolamine (MEA) process. The project was aimed at performing laboratory- and bench-scale experiments to prove its technical feasibility and generate process engineering and scale-up data, and conducting a techno-economic analysis (TEA) to demonstrate its energy use and cost competitiveness over the MEA process. To meet project goals and objectives, a combination of experimental work, process simulation, and technical and economic analysis studies were applied. The project conducted individual unit lab-scale tests for major process components, including a first absorption column, a GPS column, a second absorption column, and a flasher. Computer simulations were carried out to study the GPS column behavior under different operating conditions, to optimize the column design and operation, and to optimize the GPS process for an existing and a new power plant. The vapor-liquid equilibrium data under high loading and high temperature for the selected amines were also measured. The thermal and oxidative stability of the selected solvents were also tested experimentally and presented. A bench-scale column-based unit capable of achieving at least 90% CO₂ capture from a nominal 500 SLPM coal-derived flue gas slipstream was designed and built. This integrated, continuous, skid-mounted GPS system was tested using real flue gas from a coal-fired boiler at the National Carbon Capture Center (NCCC). The technical challenges of the GPS technology in stability, corrosion, and foaming of selected solvents, and environmental, health and safety risks have been addressed through experimental tests, consultation with vendors and engineering analysis. Multiple rounds of TEA were performed to improve the GPS-based PCC process design and operation, and to compare the energy use and cost performance of a nominal 550-MWe supercritical pulverized coal (PC) plant among the DOE/NETL report Case 11 (the PC plant without CO₂ capture), the DOE/NETL report Case 12 (the PC plant with benchmark MEA-based PCC), and the PC plant using GPS-based PCC. The results reveal that the net power produced in the PC plant with GPS-based PCC is 647 MWe, greater than that of the Case 12 (550 MWe). The 20-year LCOE for the PC plant with GPS-based PCC is 97.4 mills/kWh, or 152% of that of the Case 11, which is also 23% less than that of the Case 12. These results demonstrate that the GPS-based PCC process is energy-efficient and cost-effective compared with the benchmark MEA process.

Chen, Shiaoguo↗

Xe/Kr Selectivity Measurements using AgZ-PAN at Various Temperatures

In preparation for planned FY-15 Xe/Kr multi-column testing, a series of experiments were performed to determine the selectivity of Xe over Kr using the silver converted mordenite-polyacrylonitrile (AgZ-PAN) sorbent. Results from these experiments will be used for parameter selection guidelines to define test conditions for Kr gas capture purity evaluations later this year. The currently configured experimental test bed was modified by installing a new cooling apparatus to permit future multi-column testing with independent column temperature control. The modified test bed will allow for multi-column testing to facilitate a Xe separation followed by a Kr separation using engineered form sorbents. Selectivity experiments were run at temperatures of 295, 250 and 220 K. Two feed gas compositions of 1000 ppmv Xe, 150 ppmv Kr in either a He or an air balance were used. AgZ-PAN sorbent selectivity was calculated using Xe and Kr capacity determinations. AgZ-PAN sorbent selectivities for Xe over Kr of 72 were calculated at room temperature (295 K) using the feed gas with a He balance and 34 using the feed gas with an air balance. As the test temperatures were decreased the selectivity of Xe over Kr also decreased due to an increase in both Xe and Kr capacities. At 220 K, the sorbent selectivities for Xe over Kr were 22 using the feed gas with a He balance and 28 using the feed gas with an air balance. The selectivity results indicate that AgZ-PAN used in the first column of a multi-column configuration will provide adequate partitioning of Xe from Kr in the tested temperature range to produce a more pure Kr end product for collection.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cesium Removal from Tank Waste Simulants Using Crystalline Silicotitanate at 12% and 100% TSCR Bed Heights

The Direct Feed Low-Activity Waste flowsheet provides for the early production of immobilized low-activity waste (LAW) by feeding waste directly from Hanford tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for vitrification. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank waste supernatant will be pretreated by the Tank Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18E-5 Ci 137 Cs/mole of Na). This pretreatment will remove cesium from the waste stream using ion exchange (IX). The selected media for IX is crystalline silicotitanate (CST), product number UOP-IONSIV-R9140-B, manufactured by Honeywell UOP LLC (Des Plaines, IL). Testing was requested by Washington River Protection Solutions to better define IX processing using Low-Activity Waste Pretreatment System (LAWPS) prototypic IX unit operation process steps at full height and medium height. The information is intended to significantly contribute towards establishing accurate process flowsheets for the individual feed campaigns planned for the LAWPS. Column testing at both the medium (12% of the full bed height) and full height scales was conducted to evaluate process variables and scale up performance of Cs exchange onto the CST, Lot 8056202-999. Nominal process conditions used 5.6 M Na simulant processed at 1.8 bed volumes per hour (BV/h) at 20 °C. Process variables included 1) increased process temperature to 35 °C, 2) increased Na concentration to 6.0 M, 3) added organics to the 5.6 M Na simulant, and 4) flowrate changes. The medium scale tests used single columns containing 44 mL of <25 mesh CST in a 1.44 cm diameter column, 27 cm tall CST bed. The full height columns used lead/lag columns containing 1.15 L unsieved (as-received) CST in 2.54-cm-diameter columns, 226 cm tall CST beds. Two process flowrates were tested at the full height: 1.30 and 1.82 BV/h. IX testing with simulant solutions was conducted using TSCR prototypic IX unit operations: feed processing, feed displacement with 0.1 M NaOH, water rinse, and solution expulsion with compressed air.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heat and Mass Transfer Study to Understand Thermal-Cycling Absorption Process (TCAP) Scale-Up Issues

TCAP was invented by SRNL and is a world-leading technology in hydrogen isotope separation, a critical process for fusion energy development and scientific research. External interests inquiries have been received for as high as a 1000-fold throughput increase over the currently available TCAP system. This study determined a major factor impacting TCAP column scale-up. A model derived by J. Calvin Giddings indicates that the combination of a coiled packed column and an increase in the column tube radius results in reduction of column separative performance. Reevaluation of data from SRNL TCAP column testing performed in 2004 indicates that the results are consistent with the Giddings model. Work with the Auburn University Center for Microfibrous Materials Manufacturing indicates that microfibrous entrapped sorbents (MFES) made from copper microfibers and Pd K could resolve issues with channeling and improve heat transfer and cycle time in TCAP columns.

36 MATERIALS SCIENCE↗

GeoCarb Calibration Campaign Field Campaign Report

The GeoCarb Calibration Campaign, referred to as the Total Carbon Column Observing Network (TCCON) calibration campaign within this report for clarity, involved a series of single- and multiple-day Bruker EM27/SUN Fourier transform infrared (FTIR) spectrometer deployments at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory in Oklahoma. The EM27/SUN instruments directly measure infrared solar radiation in a wavelength range from 4000 to 11000 cm -1 at a spectral resolution of 0.5 cm -1 and varied temporal resolution of approximately 15 seconds. The solar radiation observed by these spectrometers contains information about the concentrations of atmospheric constituents present between the instruments and the top of the atmosphere, as every gas and particle in the atmosphere absorbs solar radiation at different wavelengths depending on their physical and chemical makeup. Through retrieval algorithm processing, the solar radiation data collected by EM27/SUN instruments can be used to infer total column dry-air mole fractions, or total column concentrations, of different trace gases present in the atmosphere. These total column concentrations, denoted as Xgas , represent the concentration, in ppb or ppm, of a trace gas in the column of atmosphere between an instrument and the top of the atmosphere. EM27/SUN instruments are primarily used to infer total column concentrations of carbon dioxide (CO 2 ), carbon monoxide (CO), methane (CH 4 ), and water vapor.

54 ENVIRONMENTAL SCIENCES↗