Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Enhancing Fire Resiliency of Fixatives and Coatings for D and D Activities to Mitigate Potential Release of Radioisotopes during Fire and Extreme Heat Conditions - 16393

In discussions with officials from the Department of Energy's Office of Environmental Management and Savannah River National Laboratory (SRNL), the requirement for enhancing the operational performance of fixatives, coatings, and decontamination gels to better address the unique deactivation and decommissioning (D and D) challenges being faced by the SRS 235-F Project, and other high priority D and D efforts across the DOE Complex such as the Waste Isolation Pilot Plant (WIPP), has been identified as a priority focus area for research and development (R and D). Of particular interest is the immediate operational requirement to enhance a fixative's fire resiliency and survivability under fire and extreme heat conditions in order to mitigate the potential release of radioisotopes into the environment when subjected to these conditions. In support of the DOE-FIU Cooperative Agreement, under the Waste and D and D Engineering and Technology Development Project, Task 2: D and D Support for Technology Innovation, Development, Evaluation and Deployment, the FIU Applied Research Center (ARC), in close collaboration with SRNL, is leading the development, implementation, and execution of a phased effort to improve the operational effectiveness of fixative technologies in the critical areas highlighted above, and specifically focusing on enhancing fire resiliency without degrading fixing capacity or decontamination factor (DF). The research area being explored involves the analysis, laboratory experimentation, and testing of existing products, which through layering/combining with an intumescent coating, could possibly produce a synergistic effect, resulting in a new and improved process / material with characteristics that significantly improve operational performance in this area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation and Experimental Validation of an Integrated Heat Pump – Thermal Energy Storage Using a Room-Temperature Phase Change Material

As the dependence on electrical heat pumps (HPs) and intermittent renewables increases, grid strains are expected to grow. This necessitates an energy storage system to reduce the mismatch between energy supply and demand. Thus, a proposed dual-mode commercially available 14.1 kW HP was integrated with a single 22°C phase change material (PCM) thermal storage system (TES) to load-shift both cooling and heating loads. The HP-TES system was manufactured and experimentally tested using a novel test matrix based on AHRI 210/240 psychrometric conditions. Furthermore, transient dual-mode system-level HP-TES models were developed in Modelica and validated using the experimental test conditions. Base HP cooling and heating experimental tests at ambient temperatures of 35°C and −8.3°C show that the modified HP-TES maintained the rated system capacity and performance. The HP-TES discharge provided approximately 30% and 50% reductions in cooling and heating demand, respectively. The transient HP-TES models predicted system capacity and total power input for discharge and recharge operating modes within ±4% mean percentage error, and recharge power input within ±2%, with maximum errors occurring at the equipment startup. During system operation, the sources of model deviations are first-order polynomial fits of the PCM digital scanning calorimetry (DSC) data and unaccounted supercooling in the PCM during solidification. Nonetheless, the model predictions agree with the experimental tests, demonstrating the availability of robust, accurate, and validated transient models that can be used for further validation and the development of system controls.

25 ENERGY STORAGE↗

Storing Co 2 in Built Infrastructure: Co 2 Carbonation of Precast Concrete Products

The overall objective of the proposed study was to advance the technical understanding of CO 2 incorporation into novel cementitious materials for the development of high value products that provide a net reduction in carbon emissions. This project combined two primary phases of research that addressed technical barriers related to (i) optimizing CO 2 storage capability of cementitious materials, (ii) evaluating and enhancing physical properties of novel carbonated materials, and (iii) assessing the reductions in life cycle CO 2 emissions attributed to CO 2 carbonation of precast cementitious materials. Engineered cementitious composites (ECC) are a class of highly ductile concrete composites that have been shown to be very durable when used in the built environment. CO 2 carbonation of ECC was examined in this study and it was found that precast ECC specimens could sequester up to 35% CO 2 by cement mass after 24 hours of curing at a CO 2 pressure of 0.5 MPa and 23°C and had a strain capacity of 3%. Carbonation conditions were optimized at the bench-scale and then utilized to create full-scale CO 2 -cured ECC railroad ties that were field tested on a train track. Rail ties were selected for this initial assessment of CO 2 storage in precast concrete materials due to the large market for concrete ties in the railroad industry. Although the full-scale rail ties passed all of the required American Railway Engineering and Maintenance-of-Way Association qualifying mechanical tests, on-track testing of the CO 2 -cured ECC rail ties was unsuccessful due to fiber alignment in the ECC the during the rail tie casting process which prevented the material from achieving the expected level of strain capacity. This result highlights the challenge in scaling up bench-scale processes to full-scale product manufacturing and requires additional investigation into the casting process of large-scale infrastructure elements using ECC combined with carbonation curing. Life cycle assessment of a CO 2 -cured ECC rail tie versus a traditional concrete rail tie indicates that the ECC tie can have lifecycle carbon savings of between 11% and 51% depending on how much longer its useful lifetime is compared to traditional concrete rail ties. Both carbon and cost savings are driven by a reduction in the need to replace broken rail ties, so the key factor is the extent to which a CO 2 -cured ECC rail tie will have increased lifetime durability compared to alternative rail ties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternative Materials Literature Review: A Review of Alternative Materials for Xenon Capture in Comparison to AgZ-PAN

A collaborative literature review between Idaho National Laboratory (INL) and Pacific National Laboratory (PNNL) was conducted to research alternative metals/materials for xenon adsorption in gaseous effluents generated from used nuclear fuel (UNF) reprocessing. The review was conducted to research sorbents that could outperform silver mordenite (AgZ) at ambient temperature. The use of silver requires complex and expensive waste disposal processes due to it being an RCRA metal, therefore alternative materials need to be researched and evaluated. The report details two different types of sorbent material: alternative zeolite materials and non-zeolite-based materials (i.e., MOFs, COFs, etc.). This report documents a brief history of the materials, what testing has been conducted on them, and what results suggest the possibility of outperforming the silver-based materials. Sorbent performance characteristics such as durability, capacity, and operating temperatures were evaluated. The simplicity of the sorbents was also evaluated, meaning how they are acquired (synthesized vs. naturally abundant). Recommendations were made for the most promising sorbents based on available research in the subject area and these recommended sorbents will be tested in the upcoming fiscal year. The recommended sorbents that are zeolite based are CHA zeolites, ZIF-69, and Na-ETS-10. The recommended sorbents that are non-zeolite based are SBMOF-1 and CC3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Alternative Materials Literature Review: A Review of Alternative Materials for Xenon Capture in Comparison to AgZ-PAN

A collaborative literature review between Idaho National Laboratory (INL) and Pacific National Laboratory (PNNL) was conducted to research alternative metals/materials for xenon adsorption in gaseous effluents generated from used nuclear fuel (UNF) reprocessing. The review was conducted to research sorbents that could outperform silver mordenite (AgZ) at ambient temperature. The use of silver requires complex and expensive waste disposal processes due to it being an RCRA metal, therefore alternative materials need to be researched and evaluated. The report details two different types of sorbent material: alternative zeolite materials and non-zeolite-based materials (i.e., MOFs, COFs, etc.). This report documents a brief history of the materials, what testing has been conducted on them, and what results suggest the possibility of outperforming the silver-based materials. Sorbent performance characteristics such as durability, capacity, and operating temperatures were evaluated. The simplicity of the sorbents was also evaluated, meaning how they are acquired (synthesized vs. naturally abundant). Recommendations were made for the most promising sorbents based on available research in the subject area and these recommended sorbents will be tested in the upcoming fiscal year. The recommended sorbents that are zeolite based are CHA zeolites, ZIF-69, and Na-ETS-10. The recommended sorbents that are non-zeolite based are SBMOF-1 and CC3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mercury removal from flue gases by novel regenerable magnetic nanocomposite sorbents

Magnetic zeolite composites with supported silver nanoparticles are a new class of multifunctional materials with potential applications as recyclable catalysts, disinfectants, and sorbents. This study evaluated the suitability of the magnetic composites as sorbents for the removal of elemental mercury vapor from flue gases of coal-fired power plants. The sorbents were found to completely capture mercury at temperatures up to 200{sup o}C, and the mercury capacity of the sorbents was found to be affected by the state, content, and size of the silver particles in the composite. Cumulative or extended thermal treatments at 400{sup o}C were found to improve the mercury capture capacity, allowing the sorbent to be regenerated and recycled multiple times without performance degradation. The magnetic sorbent was readily separated from fly ash by magnetic separation, leaving the fly ash essentially free of sorbent contamination. In initial in-plant tests, the sorbents were able to capture mercury from the flue gases of an operational, full-scale, coal-fired power plant. The combination of mercury capacity, ease of separation and regeneration, and recyclability makes these multifunctional magnetic composites excellent candidate sorbents for the control of mercury emissions from coal-fired power plants. 35 refs., 5 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Neutron diffraction studies of the Na-ion battery electrode materials NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3}

The new compounds NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} were synthesized by sol-gel method and their crystal structures were determined by using neutron powder diffraction data. These compounds were characterized by galvanometric cycling and cyclic voltammetry. NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} crystallize with a stuffed α-CrPO{sub 4}-type structure. The structure consists of a 3D-framework made of octahedra and tetrahedra that are sharing corners and/or edges generating channels along [100] and [010], in which the sodium atoms are located. Of significance, in the structures of NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} a statistical disorder Ni{sup 2+}/Cr{sup 3+} was observed on both the 8g and 4a atomic positions, whereas in NaCoCr{sub 2}(PO{sub 4}){sub 3} the statistical disorder Co{sup 2+}/Cr{sup 3+} was only observed on the 8g atomic position. When tested as negative electrode materials, NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} delivered specific capacities of 352, 385, and 368 mA h g{sup −1}, respectively, which attests to the electrochemical activity of sodium in these compounds. - Highlights: • NaCoCr{sub 2}(PO{sub 4}){sub 3}, NaNiCr{sub 2}(PO{sub 4}){sub 3}, and Na{sub 2}Ni{sub 2}Cr(PO{sub 4}){sub 3} were synthesized by sol-gel method. • The crystal structures were determined by using neutron powder diffraction data. • The three compounds crystallize with a stuffed α-CrPO{sub 4}-type structure. • The three compounds were tested as anodes in sodium-ion batteries. • Relatively high specific capacities were obtained for these compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Degradation mechanism of over-charged LiCoO 2 /mesocarbon microbeads battery during shallow depth of discharge cycling

LiCoO 2 /mesocarbon microbeads (MCMB) batteries are over-charged to different voltage (4.4 V, 4.5 V, 4.6 V, and 4.7 V, respectively) for ten times, and then are cycled 1000 times for shallow depth of discharge. The morphology, structure, and electrochemical performance of the electrode materials were studied in detail in order to identify the capacity fading mechanism of over-charged battery after long-term cycling. The cycling performances of LiCoO 2 /MCMB batteries are gradually aggravated with the increase of over-charging voltage and the degradation mechanism is diverse upon the degree of over-charging. Furthermore, the capacity fading after long-term cycling of battery over-charged to 4.6 V or 4.7 V is mainly attributed to the cathodes. Soft X-ray absorption spectroscopy (XAS) demonstrates that the lower valence state of cobalt exists on the surface of the LiCoO 2 after serious over-charging (4.6 V or 4.7 V), and cobalt is dissolved then deposited on the anode according to the result of energy dispersive spectrometry (EDS). But, after shallow over-charging (4.4 V or 4.5 V), the capacity deterioration is proposed as the loss of active lithium, presented by the generation of the SEI film on the anode, which is verified by water washed tests.

25 ENERGY STORAGE↗

Physiologic Pressure and Flow Changes During Parabolic Flight (Pilot Study)

The objective of this study was to obtain measurement of cutaneous tissue perfusion central and peripheral venous pressure, and esophageal and abdominal pressure in human test subjects during parabolic flight. Hemodynamic data recorded during SLS-I and SLS-2 missions have resulted in the paradoxical finding of increased cardiac stroke volume in the presence of a decreased central venous pressure (CVP) following entry in weightlessness. The investigators have proposed that in the absence of gravity, acceleration-induced peripheral vascular compression is relieved, increasing peripheral vascular capacity and flow while reducing central and peripheral venous pressure, This pilot study seeks to measure blood pressure and flow in human test subjects during parabolic flight for different postures.

Pantalos, George↗

Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The Life-Cycle Cost (LCC) calculation examines costs and benefits from the perspective of the individual household; and (2) The National Perspective projects the total national costs and benefits including both financial benefits, and energy savings and environmental benefits. The national perspective calculations are called the National Energy Savings (NES) and the Net Present Value (NPV) calculations. PAMS also calculate total emission mitigation and avoided generation capacity. This paper describes the data and methodology used in PAMS and presents the results of the proposed phase out of incandescent bulbs in Chile.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of Path Dependence in Commercial Li-ion Cells Chosen for PHEV Duty Cycle Protocols (paper)

Path dependence is emerging as a premier issue of how electrochemical cells age in conditions that are diverse and variable in the time domain. For example, lithium-ion cells in a vehicle configuration will experience a variable combination of usage and rest periods over a range of temperature and state of charge (SOC). This is complicated by the fact that some aging can actually become worse (or better) when a lithium-ion cell is idle for extended periods under calendar-life (calL) aging, as opposed to cycle-life (cycL) conditions where the cell is used within a predictable schedule. The purpose of this study is to bridge the gap between highly idealized and controlled laboratory test conditions and actual field conditions regarding PHEV applications, so that field-type aging mechanisms can be mimicked and quantified in a repeatable laboratory setting. The main parameters are the magnitude and frequency of the thermal cycling, looking at isothermal, mild, and severe scenarios. To date, little is known about Li-ion aging effects caused by thermal cycling superimposed onto electrochemical cycling, and related path dependence. This scenario is representative of what Li-ion batteries will experience in vehicle service, where upon the typical start of a HEV/PHEV, the batteries will be cool or cold, will gradually warm up to normal temperature and operate there for a time, then will cool down after the vehicle is turned off. Such thermal cycling will occur thousands of times during the projected life of a HEV/PHEV battery pack. We propose to quantify the effects of thermal cycling on Li-ion batteries using a representative chemistry that is commercially available. The secondary Li-ion cells used in this study are of the 18650 configuration, have a nominal capacity rating of 1.9 Ah, and consist of a {LiMn2O4 + LiMn(1/3)Ni(1/3)Co(1/3)O2} cathode and a graphite anode. Electrochemical cycling is based on PHEV-relevant cycle-life protocols that are a combination of charge depleting (CD) and charge sustaining (CS) modes discussed in the Battery Test Manual for Plug-in Hybrid Electric Vehicles (INL, March 2008, rev0). A realistic duty cycle will involve both CD and CS modes, the proportion of each defined by the severity of the power demands. We assume that the cells will start each cycling day at 90% SOC, and that they will not be allowed to go below 35% SOC, with operation around 70% SOC being a nominal condition. The 35, 70, and 90% SOC conditions are also being used to define critical aspects of the related reference performance test (RPT) for this investigation. There are three primary components to the RPT, all assessed at room temperature: (A) static and residual capacity (SRC) over a matrix of current, (B) kinetics and pulse performance testing (PPT) over current for SOCs of interest, and (C) EIS for SOCs of interest. The RPT is performed on all cells every 30 day test interval, as well as a pulse-per-day to provide a quick diagnostic snapshot. Where feasible, we utilize various elements of Diagnostic Testing (DT) to characterize performance of the cells and to gain mechanistic-level knowledge regarding both performance features and limitations. We will present the rationale behind the experimental design, early data, and discuss the fundamental tools used to elucidate performance degradation mechanisms.

25 ENERGY STORAGE↗

Magnetic suspension and balance system advanced study

An improved compact design for a superconducting magnetic suspension and balance system for an 8 ft. x 8 ft. transonic wind tunnel is developed. The original design of an MSBS in NASA Cr-3802 utilized 14 external superconductive coils and a superconductive solenoid in the airplane test model suspended in a wind tunnel. The improvements are in the following areas: test model solenoid options, dynamic force limits on the model, magnet cooling options, structure and cryogenic designs, power supply specifications, and cost and performance evaluations. The improvements are: MSBS cost reduction of 28%, weight; reduction of 43%, magnet system ampere-meter reduction of 38%, helium liquifier capacity reduction by 33%, magnet system stored energy reduction by 55%, AC loss to liquid helium reduced by 76%, system power supply reduced by 68%, test coil pole strength increased by 19%, wing magnetization increased by 40%, and control frequency limit increased by 200% from 10 Hz to 30 Hz. The improvements are due to: magnetic holmium coil forms in the test model, better rare earth permanent magnets in the wings, fiberglass-epoxy structure replacing stainless steel, better coil configuration, and new saddle roll coil design.

Boom, R. W.↗

Iodine Removal from Carbonate-Containing Alkaline Liquids Using Strong Base Resins, Hybrid Resins, and Silver Precipitation

The ability of several material types to remove aqueous iodine from a mildly alkaline, carbonate-rich nuclear waste stream was evaluated: strong base anion exchange resins (SBAR), hybrid resins, Ag-containing materials and Bi-containing hybrid resins. A combination of batch testing and flow through column testing were used in the evaluation. In batch testing, hybrid resins CHM-20, SIR-110-CE and RTBI were shown to have high efficiency for the removal of both iodide and iodate simultaneously, while Ag-containing materials and SBAR demonstrated high capacity for iodide removal. One example of each material type (CHM-20, A532E and Ionex 400) were further evaluated for their sorption isotherms and column performance. The Langmuir isotherm, or a Langmuir-Freundlich hybrid isotherm, best described the sorption of iodide to the CHM-20 hybrid resin and Purolite A532E. The Freundlich isotherm best described the uptake of iodate to CHM-20 and A532E and for both iodide and iodate to the Ag-containing Ionex-400. In column testing the Purolite A532E had exceptional performance for overall iodide removal. With the capacity demonstrated the A532E resin would exceed Class C waste classification before breakthrough initiated, and column change outs in processing would be dictated by eventual waste classification, not breakthrough. The Ionex 400, a Ag-zeolite, was observed to degrade over time in the column in the mild alkaline conditions whereas the hybrid CHM-20 was limited in the single pass through design and would be best suited for applications where iodide and iodate are present and recirculation of the column effluent is feasible. Here this work highlights the feasibility of commercially available materials to separate radioiodine from liquid environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low level CO2 effects on pulmonary function in humans

The purpose of the study was to determine whether chamber exposure to low levels of CO2 results in functional alterations in gas mixing and closing volume in humans. Four healthy volunteer subjects were exposed to 0.7% CO2 and to 1.2% CO2. Spirometry, lung volumes, single breath nitrogen washout, diffusing capacity for carbon monoxide (DLCO) by two methods, and cardiac output were measured in triplicate. Values were obtained over two non-consecutive days during the training period (control) and on days 2 or 3, 4, 6, 10, 13, and 23 of exposure to each CO2 level. Measurements were made during the same time of day. There was one day of testing after exposure, while still in the chamber but off carbon dioxide. The order of testing, up until measurements of DLCO and cardiac output, were randomized to avoid presentation effects. The consistent findings were a reduction in diffusing capacity for carbon monoxide and a fall in cardiac output, occurring to a similar degree with both exposures. For the group as a whole, there was no indication of major effects on spirometry, lung volumes, gas mixing or dead space. We conclude that small changes may occur in the function of distal gas exchanging units; however, these effects were not associated with any adverse health effects. The likelihood of pathophysiologic changes in lung function or structure with 0.7 or 1.2% CO2 exposure for this period of time, is therefore, low.

NASA Discipline Cardiopulmonary↗

Navigation Flight Test Results from the Low Power Transceiver Communications and Navigation Demonstration on Shuttle (CANDOS) Experiment

This paper presents the Global Positioning System (GPS) navigation results from the Communications and Navigation Demonstration on Shuttle (CANDOS) experiment flown on STS-107. This experiment was the initial flight of a Low Power Transceiver (LPT) that featured high capacity space- space and space-ground communications and GPS- based navigation capabilities. The LPT also hosted the GPS Enhanced Orbit Determination Experiment (GEODE) orbit determination software. All CANDOS test data were recovered during the mission using LPT communications links via the Tracking and Data Relay Satellite System (TDRSS). An overview of the LPT s navigation software and the GPS experiment timeline is presented, along with comparisons of test results to the NASA Johnson Space Center (JSC) real-time ground navigation vectors and Best Estimate of Trajectory (BET).

Haas, Lin↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 1. Characterizing Thermal–Hydrological–Mechanical Processes

Abstract Bentonite clay is widely used in engineered barrier systems for the permanent disposal of high‐level radioactive waste due to its low permeability, high swelling capacity, and thermal stability. However, the complex thermal‐hydrological‐mechanical (THM) processes induced by heating from decaying radioactive waste and hydration from surrounding rock can lead to heterogeneous changes that are difficult to measure and predict. This study develops an Electrical Resistivity Tomography (ERT)‐based framework for monitoring THM processes, progressing from sample‐scale to bench‐scale tests, to inform field‐scale applications. Sample‐scale tests analyzed small bentonite samples under controlled variations in water content, temperature, and porosity to establish fundamental resistivity relationships. Bench‐scale tests involved larger bentonite columns subjected to heating (up to 200°C) and hydration under controlled pressure, simulating repository conditions. ERT measurements, complemented by X‐ray CT imaging, temperature monitoring, and tracing sensors, revealed coupled THM processes, such as hydration‐induced compression, swelling, and thermal gradients, leading to complex resistivity patterns. The results demonstrate the potential of ERT for capturing THM‐induced resistivity changes, though challenges remain in upscaling and quantitative analysis. This study evaluates laboratory test capabilities and proposes future improvements for understanding THM‐induced resistivity responses. A conceptual framework for ERT implementation in field‐scale monitoring is presented, synthesizing findings from both scales and exploring how ERT data can inform long‐term modeling and reduce prediction uncertainties. Overall, this ERT‐based framework offers a robust method for monitoring bentonite buffers, aiding in early issue detection and supporting the safe long‐term disposal of radioactive waste in geological repositories, while highlighting the need for future development. Plain Language Summary Bentonite clay is crucial in engineered barrier systems (EBS) for containing high‐level radioactive waste due to its ability to absorb water, swell, seal and remain stable under high temperatures. When bentonite absorbs water and heats up from radioactive decay, it experiences complex changes in its physical and mechanical properties. Understanding these changes is important for ensuring the long‐term safety and effectiveness of EBS. This study used Electrical Resistivity Tomography (ERT), a non‐invasive method that measures electrical conductivity to monitor these changes during laboratory experiments. The ERT data revealed significant variations in resistivity corresponding to changes in water content, temperature, and density, providing detailed spatial and temporal insights into the behavior of bentonite. These findings enhance our ability to predict the long‐term performance of bentonite barriers, ensuring the safe containment of radioactive waste. By improving our understanding of bentonite's behavior, this research supports the development of more reliable and effective barrier systems for radioactive waste disposal, protecting the environment and public health. Key Points ERT monitoring was employed to capture resistivity changes in bentonite during controlled heating and hydration experiments, providing insights into THM processes ERT data reveal significant resistivity changes correlated with water content, temperature, and mechanical effects, enhancing the understanding of THM dynamics in bentonite This study explores the potential of the framework for application in field‐scale EBS monitoring, emphasizing the need for integrating additional geophysical methods for comprehensive subsurface imaging

Chen, Hang↗