Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Investigating Building Energy Consumption and CO2 Emission in Phoenix Using AutoBEM and Future Typical Meteorological Year (fTMY) Weather Data

This research investigates the energy performance and CO2 emissions of each building stock across the Phoenix metropolitan area using the Automatic Building Energy Modeling (AutoBEM) framework and Model America v2 (MAv2) dataset from Oak Ridge National Laboratory (ORNL). Typical Meteorological Year (TMY) and Future Typical Meteorological Year (fTMY) files were used for AutoBEM simulation. The simulation results from TMY and fTMY were compared. It was found that a projected 10.28% increase in total CO2 emissions and a 9.30% rise in total energy consumption by 2080–2099 relative to current typical conditions. The results highlight the disparities in emissions among different building stocks and the influence of climate change on future energy demand. The findings underscore the necessity of targeted policy interventions and retrofitting strategies (eg. advanced HVAC systems, improved insulation, reflective roofing) to mitigate emissions in high-energy-use and emission-intensed buildings, particularly as climate conditions evolve. This study contributes to the growing understanding of building-sector emissions and their long-term implications under future climate scenarios.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

EnergyPlus Interior Radiant Heat Exchange Runtime Performance Improvements

EnergyPlus is the flagship whole-building energy simulation program developed by the US Department of Energy. This paper describes the various approaches to improve the performance of the interior radiant heat exchange algorithm. Vectorization, optimized Basic Linear Algebra Subprograms (BLAS) library, multithreading, and Graphical Processing Unit (GPU) computation are all investigated. The approach with the best performance, while maintaining drop-in compatibility with existing EnergyPlus code, is the optimized BLAS library. However, GPU computing has the potential to reduce simulation time by orders of magnitude with major refactoring to EnergyPlus.

Adams, Mark↗

A New Appraisal- Lessons from the History of Efforts to Value Green and High-Performance Home Attributes in the United States

Rigorous consideration of green and high-performance (“green/HP”) features is rarely included in the property valuation process._ To help illuminate why this is the case, this report takes stock of the history of efforts to improve practices, and identifies barriers that have emerged and opportunities for overcoming them. Particular emphasis is placed on what energy and environmental policymakers and other stakeholders outside the appraisal community can contribute to the broader effort to advance professional practices. The history has unfolded in parallel with turbulent periods in the housing market for which appraisers and their customers are deemed to share responsibility, followed by cycles of regulations, siloing of appraisers in the name of professional integrity, and commoditization of the valuation process itself. This pattern has important ramifications for aspirations that appraisers engage more fully in identifying and valuing the green/HP characteristics of homes. On the one hand, it is legally and ethically incumbent on appraisers to do so, yet on the other hand it is perceived as a risky avenue to follow. Risks arise where findings can be challenged as either over- or under-stating value, together with a market environment in which the complexity of their assignments increases despite downward pressure on appraiser fees. While efforts to address green/HP considerations date back to the early 1980s, the vast majority of activity has taken place within the past five years. Many players have engaged in the efforts to promote improved valuation practices. These include the Appraisal Foundation, The Appraisal Institute, Colorado Energy Office, Earth Advantage, EcoBroker, Elevate Energy, Fannie Mae, Federal Housing Administration, Home Innovation Research Labs, The Institute for Market Transformation, Northwest Energy Efficiency Alliance, National Association of Homebuilders, National Association of State Energy Officials, National Association of Appraisers, RESNET, USEPA, USDOE and its National Laboratories, the U.S. Green Buildings Council, and the Vermont Green Homes Alliance. Many activities have resulted, ranging from trainings, to data-gathering instruments, and the emergence of a literature attempting to statistically isolate the effects of green/HP characteristics on home values. In some cases, the results of studies have been overgeneralized and oversold, and embodied flawed methods. Although the green/HP community has encouraged appraisers to focus on exemplary buildings (e.g., LEED or ENERGY STAR Certified), any level of green or energy performance can in fact influence value, including below-average performance (a.k.a. “brown discount”), irrespective of whether or not the building has been formally rated. This overly narrow focus represents a significant missed opportunity. Other surmountable challenges include limitations to non-appraisers’ understanding of the appraisal process (and practical constraints therein). A byproduct of this can be unrealistic expectations of what appraisers can and will do in the marketplace. These challenges notwithstanding, the environment for moving forward has improved. There is better data today (a critical need); expanded efforts to disclose energy use information (characteristics, consumption, bills); improved and more pervasive building energy codes, building rating and labeling initiatives; and a host of federal, state, and local policies that have collectively brought green/HP practices much more into the mainstream. Meanwhile, a renewed focus on professional standards of care and competency for assessing green/HP homes make it increasingly important for appraisers to consider these factors in their assignments. Despite the past four decades of studies, there is little if any discernible uptake of these practices by the appraisal practice at large. It would behoove interested parties to step back and consider what new strategies might be productive. A key element of any new plan should be to reset the nature of interactions with the industry, with the goal a more collaborative, two-way discussion to help improve outsiders’ understanding of the valuation process. It is not only the appraiser that needs to be engaged and could benefit from awareness raising. Homeowners, builders, lenders, utilities, insurance companies should also provide input on how green/HP factors impact property valuations and ways to accurately reflect these considerations in appraisals and real estate transactions more broadly. Given extensive inertia within the appraisal industry and a mixed history of interactions with the non-appraisal stakeholders, it is unlikely that the status quo will achieve much unless followed with more coordinated and persistent efforts. Workshops, studies, and memoranda of understanding will not on their own have much impact, and do not address deeper structural issues. Expectations are often unrealistic and not attentive to real-world constraints faced by appraisers. The report identifies key barriers impeding more thorough consideration of green/HP factors in residential real estate appraisals, and solutions for mitigating them. Barriers • Although industry standards of practice caution against bias of any sort, a skeptical predisposition towards “green” is reinforced by information deficiencies. • Information deficiencies result from the lack or difficulty of obtaining usable data on green/HP features in subject properties as well as valid sales comparisons or cashflow analyses. • Competency deficiencies, such as lack of conversancy in relevant technical topics, leads to oversights, and disjointed treatment of relevant information. • Time/cost pressure and process commoditization (e.g., template-based approaches) result from highly constrained budgets, quick turn-around times expected of appraisers, and standardized practices that were not developed with green/HP considerations in mind. • Professional differences between appraisers and sustainability professionals include divergent objectives, the former being market observers and the latter market influencers. • Risk aversion arises from multiple concerns including veracity, accuracy, and persistence of energy data, impacts of operational choices, new sources of appraiser liability associated with green/HP assessments, industry pressures not to over-value buildings or suggestion of bias, and concern about spending non-billable time on complex assignments. • A public policy vacuum has been created by disjointed and uncoordinated efforts from public-sector stakeholders, insufficient efforts to discuss and understand the appraisal industry and process, and a perception by some valuation professionals that green/HP is oversold. Opportunities • Elevating the competency of appraisers can be achieved through a combination of improved industry standards of care and equal-access training and professional development offerings. • Development of better information resources must focus on building-level information that provides robust documentation as well as aggregate sales-comparison data and other contextual information such as local codes, typical upgrade costs, energy prices, etc. • Improved energy benchmarking and rating tools could provide appraisers with information more well-adapted to their particular needs, which differ from those of typical audiences such as energy managers. • Better characterizing and managing risk will enable appraisers to cope with uncertainties in performance information, and help identify where risks may be introduced or mitigated by green/HP features, including higher costs or obsolescence of poorly-performing buildings. • Integrating disaster resilience and sustainability in appraisals would recognize important synergisms among these features, including durability and ability of green/HP buildings to better withstand external hazards. • Mitigating the problem of additional time/cost for performing assignments is an essential need that can be addressed by providing easier access to information and analytic procedures, perhaps coupled with new resources to defray the associated costs. • Enhancing demand for improved appraisals is a fundamental need, and depends on owners, developers, lenders, and others soliciting competent appraisers to perform scopes that expressly call out green/HP considerations, and to critically review the work product for compliance before acceptance. • Engaging new market participants, such as energy utilities and insurance companies can ensure fuller representation and participation of market stakeholders already engaged in green/HP activities and capable of furnishing valuable data and managing associated risks. Cutting across these individual activities, there is a need for outside stakeholders to formulate and follow a roadmap instead of piecemeal initiatives, bridging the professional/cultural divide between appraisers and green/HP communities, and tracking progress in order to know what is working. A more coherent communication and training strategy is needed, as the appraisal industry is highly fragmented, with two-thirds of appraisers opting out of membership in trade associations. In sum, while there is no silver bullet for advancing the practice of valuing green/HP features, there are concrete opportunities. Parties seeking solutions must identify barriers they wish to address and select from among potential initiatives that map to those barriers. Close collaboration with the appraisal community is critical, as non-appraisers have historically obtained limited traction with this industry due to lack of understanding of the nuances involved in the valuation profession. Large organizations and agencies should have a united approach; the perception or reality of a fragmented and uncoordinated strategy is unsettling for prospective partners in the appraisal industry. This requires improved communication and education within and among these communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America

IBACOS researched the constructability and viability issues of using high performance windows as one component of a larger approach to building houses that achieve the Building America 70% energy savings target.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Looking For Value in All The Wrong Places. Toward Expanded Consideration of Green and High Performance Attributes in Non-residential Property Appraisals in the United States

Large numbers of commercial buildings have sought to improve their energy and environmental performance, with half of all leasable U.S. offices now designated at some level of “green”. All proper/es fall somewhere on the green/high-­performance spectrum (above and below average) whether or not they bear a formal label or ra/ng.1 Variations in the level of performance can either positively or negatively influence value. This component of value can be shaped by many factors, from utility costs to tenant/owner preferences that translate into income (rent levels, vacancy rates, lease-­up /mes, etc.). Occupant perceptions of indoor environmental quality are another potential influence on value. While there has been little uptake of this thinking by practicing appraisers, the increased prevalence of green/HP practices combined with concerns about appraiser competency are compelling the industry to adapt their traditional techniques to this new driver of value. However, the overly narrow focus of policymakers on appraisal of labeled or rated exemplary buildings (e.g., LEED or ENERGY STAR Certified) represents a significant missed opportunity. Any level of green or energy performance can in fact influence value, including below-­average performance (a.k.a. “brown discount”), irrespec/ve of whether or not the building has been formally rated. Another surmountable challenge is the limitations to non-­appraisers’ understanding of the appraisal process (and constraints therein). A crucial byproduct of this is unrealistic expectations of what appraisers can and will do in the marketplace. This report identifies opportunities for catalyzing improvement of the green/HP appraisal process, which apply to all involved actors—from owner, report-­ordering client, the appraiser, and the appraisal reviewer—and fostering more demand for appraisals that recognize green/HP property attributes. The intended audience is primarily the public policy community and other stakeholders outside the formal appraisal community who can contribute to the broader effort to advance professional practces. The discussion begins with a descripton of the appraisal process and the points at which green/HP consideratons can enter the analysis. A series of major barriers to better practces are identfied along with approaches to reducing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capturing the full benefits of bifacial modules to approach an LCOE of 3c/kWh through a regional optimization of the electrical architecture (Final Technical Report)

This is the final technical report for the Cypress Creek Renewables project focused on bifacial plant performance. The project consisted of building a heavily instrumented Bifacial test sites with several cell technologies; instrumenting >1 MW scale commercial sites with both monofacial and bifacial arrays in order to understand real-world differences; and to engage with the performance modeling and financial stakeholder community to improve accuracy and increase investor confidence. The data from the test and commercial sites has been used to validate and improve the accuracy of both physics-based and reduced order modeling software. The heavily instrumented nature has been used to understand how light contributions from the sky and reflected from the ground impact different portions of the module and array while the data from the commercial sites has directly impacted how independent engineers model production from bifacial systems. The latter point has led to an increase in over 2% compared to earlier predictions. Even this modest increase has had significant downward pressure on project LCOE. As the data and results are both public, this refined modeling and empirical evidence for a higher bifacial gain than modeled, the benefits to the broader US solar community are assured.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental apparatus and methodology to test and quantify thermal performance of micro and macro-encapsulated phase change materials in building envelope applications

Thermal energy storage (TES) is used as a viable technology to shift peak electricity demand caused by the space cooling requirements in buildings. Passive TES is implemented in building envelope via micro and macroencapsulation methods. This study describes the use of a state-of-the-art laboratory to test different PCM inclusions in simplified building walls. A microencapsulated PCM and two macroencapsulated PCMs are tested in a controlled environment to gather data for validation purposes of PCM modelling algorithms in building energy modelling programs. Data indicates that the chamber environment and the heating and cooling system can conduct full-cycle tests of wall panels with PCM inclusions. This study also generates data from parallel tests on 4 wall panels which can be used in building energy modelling programs to validate the PCM modelling algorithms. The cyclic tests also capture the thermal effects of PCMs and complex PCM behaviors like sub-cooling in PCM hydrate-salts.

25 ENERGY STORAGE↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Zero Energy Ready Homes

This article describes the U.S. Department of Energy's Zero Energy Ready Home Program and Housing Innovation Awards. Since 2013, builders around the country have certified over 1,170 homes to the high performance criteria of the DOE Zero Energy Ready Home program. Each year DOE recognizes the best innovators among this group with the DOE Housing Innovation Awards. 2017 winners will be announced at an awards event taking place at the Energy & Environmental Building Alliance (EEBA) high-performance home summit October 10-12, 2017, in Atlanta, Georgia. Twenty-five builders are expected to take home awards and grand award winners in each of the five competition categories will be revealed at the conference. Participating builders represent every climate zone in the country and DOE Zero Energy Ready labeled homes can be found in 34 states. Homes represent the full spectrum of the U.S. construction industry, from affordable to production to custom homes and from single-family detached to duplexes and up to five-story multifamily buildings as well as some retrofit projects have also met the criteria. Every DOE ZER certified home is certified through the ENERGY STAR Certified Homes (Version 3.0, revision 8) program and the U.S. Environmental Protection Agency’s Indoor airPLUS program. Each home must meet the hot water distribution requirements of the EPA’s WaterSense program and the insulation requirements of the 2012 International Energy Conservation Code. If the home has HVAC ducts, they must be installed within the conditioned space of the home. Appliances, exhaust fans, ceiling fans, and most of the lighting should be ENERGY STAR qualified. The DOE Zero Energy Ready Home program also requires homes to have solar electric panels installed or at a minimum to have the conduit and electrical panel space in place for future PV installation, if the home is in a location appropriate for solar power. Homes are constructed with enough energy efficiency built in so that, with a reasonable amount of solar PV panels (i.e., small enough to fit comfortably on the roof), the home could produce enough of its own power to equal the power it uses in a year.

U.S. Department of Energy Building Technologies Pr↗

Intelligent energy buildings based on RES and nanotechnology

The paper presents the design features, the energy modelling and optical performance details of two pilot Intelligent Energy Buildings, (IEB). Both are evolution of the Zero Energy Building (ZEB) concept. RES innovations backed up by signal processing, simulation models and ICT tools were embedded into the building structures in order to implement a new predictive energy management concept. In addition, nano-coatings, produced by TiO2 and ITO nano-particles, were deposited on the IEB structural elements and especially on the window panes and the PV glass covers. They exhibited promising SSP values which lowered the cooling loads and increased the PV modules yield. Both pilot IEB units were equipped with an on-line dynamic hourly solar radiation prediction model, implemented by sensors and the related software to manage effectively the energy source, the loads and the storage or the backup system. The IEB energy sources covered the thermal loads via a south façade embedded in the wall and a solar roof which consists of a specially designed solar collector type, while a PV generator is part of the solar roof, like a compact BIPV in hybrid configuration to a small wind turbine.

14 SOLAR ENERGY↗

Advanced Insulation for High Performance Cost-Effective Wall, Roof, and Foundation Systems Final Report

The objective of this project was to explore and potentially develop high performing insulation with increased R/inch and low impact on climate change that would help design highly insulating building envelope systems with more durable performance and lower overall system cost than envelopes with equivalent performance made with materials available today. The proposed technical approach relied on insulation foams with nanoscale pores (about 100 nm in size) in which heat transfer will be decreased. Through the development of new foaming methods, of new polymer formulations and new analytical techniques, and by advancing the understanding of how cells nucleate, expand and stabilize at the nanoscale, Dow successfully invented and developed methods to produce foams with 100 nm cells and 80% porosity by batch foaming at the laboratory scale. Measurements of the gas conductivity on small nanofoam specimen confirmed quantitatively the benefit of nanoscale cells (Knudsen effect) to increase insulation value, which was the key technical hypotheses of the program. In order to bring this technology closer to a viable semi-continuous/continuous process, the project team modified an existing continuous extrusion foaming process as well as designed and built a custom system to produce 6" x 6" foam panels. Dow demonstrated for the first time that nanofoams can be produced in a both processes. However, due to technical delays, foam characteristics achieved so far fall short of the 100 nm target set for optimal insulation foams. In parallel with the technology development, effort was directed to the determination of most promising applications for nanocellular insulation foam. Voice of Customer (VOC) exercise confirmed that demand for high-R value product will rise due to building code increased requirements in the near future, but that acceptance for novel products by building industry may be slow. Partnerships with green builders, initial launches in smaller markets (e.g. EIFS), and efforts to drive cost down will help acceptance in residential and commercial retrofit and new construction.

36 MATERIALS SCIENCE↗

Performance Evaluation of an Occupancy-Based HVAC Control System in an Office Building

As new algorithms incorporate occupancy count information into more sophisticated HVAC control, these technologies offer great potential for reductions in energy costs while enhancing flexibility. This study presents results from a two-year field evaluation of an occupancy-based HVAC control system installed in an office building. Two wings on each of the building’s 2–11 floors were equipped with occupancy counters to learn occupancy patterns. In combination with proprietary machine learning algorithms and thermal modeling, the occupancy data were leveraged to implement optimized start, early closure, and adjustments to fan operation at the air handling unit (AHU) level. This study conducted a holistic evaluation of technical performance, cost-effectiveness analysis, and user satisfaction. Results show the platform reduced weekday AHU run times by 2 h and 35 min per AHU per day during the pandemic time period. Simulation shows that 6.1% annual whole-building savings can be achieved when the building is fully occupied. The results are compared with prior studies, and potential drivers are discussed for future opportunities. The assessment results shed light on the expected in-the-field performance for researchers and industry stakeholders and enabled practical considerations as the technology strives to move beyond research-grade pilot trials into product-grade deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Two Surface Contamination Sampling Techniques Conducted for the Characterization of Two Pajarito Site Manhattan Project National Historic Park Properties

Technical Area-18 (TA-18), also known as Pajarito Site, is located on Los Alamos National Laboratory property and has historic buildings that will be included in the Manhattan Project National Historic Park. Characterization studies of metal contamination were needed in two of the four buildings that are on the historic registry in this area, a “battleship” bunker building (TA-18-0002) and the Pond cabin (TA-18-0029). However, these two buildings have been exposed to the elements, are decades old, and have porous and rough surfaces (wood and concrete). Due to these conditions, it was questioned whether standard wipe sampling would be adequate to detect surface dust metal contamination in these buildings. Thus, micro-vacuum and surface wet wipe sampling techniques were performed side-by-side at both buildings and results were compared statistically. A two-tail paired t-test revealed that the micro-vacuum and wet wipe techniques were statistically different for both buildings. Further mathematical analysis revealed that the wet wipe technique picked up more metals from the surface than the microvacuum technique. Wet wipes revealed concentrations of beryllium and lead above internal housekeeping limits; however, using an yttrium normalization method with linear regression analysis between beryllium and yttrium revealed a correlation indicating that the beryllium levels were likely due to background and not operational contamination. PPE and administrative controls were implemented for National Park Service (NPS) and Department of Energy (DOE) tours as a result of this study. Overall, this study indicates that the micro-vacuum technique may not be an efficient technique to sample for metal dust contamination.

47 OTHER INSTRUMENTATION↗

Quality Control Methods for Advanced Metering Infrastructure Data

While urban-scale building energy modeling is becoming increasingly common, it currently lacks standards, guidelines, or empirical validation against measured data. Empirical validation necessary to enable best practices is becoming increasingly tractable. The growing prevalence of advanced metering infrastructure has led to significant data regarding the energy consumption within individual buildings, but is something utilities and countries are still struggling to analyze and use wisely. In partnership with the Electric Power Board of Chattanooga, Tennessee, a crude OpenStudio/EnergyPlus model of over 178,000 buildings has been created and used to compare simulated energy against actual, 15-min, whole-building electrical consumption of each building. In this study, classifying building type is treated as a use case for quantifying performance associated with smart meter data. This article attempts to provide guidance for working with advanced metering infrastructure for buildings related to: quality control, pathological data classifications, statistical metrics on performance, a methodology for classifying building types, and assess accuracy. Advanced metering infrastructure was used to collect whole-building electricity consumption for 178,333 buildings, define equations for common data issues (missing values, zeros, and spiking), propose a new method for assigning building type, and empirically validate gaps between real buildings and existing prototypes using industry-standard accuracy metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

Unraveling the core of fuel cell performance: engineering the ionomer/catalyst interface

The biggest obstacle to the widespread implementation of polymer electrolyte membrane fuel cells (PEMFCs) is their cost, primarily due to the use of platinum catalysts. The high intrinsic catalyst activity exhibited on a rotating disk electrode (RDE) is rarely realized in a membrane electrode assembly (MEA), which is a long-standing challenge for PEMFCs and a cause of low catalyst utilization. To translate the high RDE performance of a catalyst into a MEA, the design of an ideal ionomer/catalyst interface is proposed: a thin, conformal ionomer film covers the maximum surface of a Pt nanoparticle and thus simultaneously maximizes catalyst utilization, (i.e., high mass activity and electrochemically active surface area) and O 2 diffusion rate (i.e., high current density performance) without compromising proton conduction. Building such an interface is a long-standing challenge due to the lack of interaction between the ionomer and catalyst particles, resulting in large ionomer agglomerates and inhomogeneous ionomer coverage over the catalyst nanoparticle, with consequent poor fuel cell performance. In this work, this ionomer/catalyst interface has been engineered, utilizing the electrostatic attraction between positively charged catalyst and negatively charged ionomer particles in a catalyst ink and preserved in a solid catalyst layer. As a result, this interface leads to previously unachieved proton exchange membrane fuel cell performance in terms of both catalyst utilization (75% vs. 45%) and peak/rated power density (i.e., 1.430/0.930 W cm -2 , H 2 /air, cathode Pt loading: 0.1 mgPt cm -2 ) for pure Pt catalysts, even better than those of Pt alloy catalysts. This work demonstrates the formation of an interface in the liquid phase (using ultra-small-angle X-ray scattering in combination with cryo-TEM, isothermal–titration–calorimetry) and the preservation of the interface in the solid catalyst layer (using TEM) and estimates the effective coverage and thickness of the ionomer film (using limiting current density, RDE and fuel cell performance).

25 ENERGY STORAGE↗