Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity

Purpose: Total body irradiation (TBI) with megavoltage photon beams has been accepted as an important component of management for a number of hematologic malignancies, generally as part of bone marrow conditioning regimens. The purpose of this paper is to present and discuss the authors' TBI technique, which both simplifies the treatment process and improves the treatment quality. Methods: An AP/PA TBI treatment technique to produce uniform dose distributions using sequential collimator reductions during each fraction was implemented, and a sample calculation worksheet is presented. Using this methodology, the dosimetric characteristics of both 6 and 18 MV photon beams, including lung dose under cerrobend blocks was investigated. A method of estimating midplane lung doses based on measured entrance and exit doses was proposed, and the estimated results were compared with measurements. Results: Whole body midplane dose uniformity of {+-}10% was achieved with no more than two collimator-based beam modulations. The proposed model predicted midplane lung doses 5% to 10% higher than the measured doses for 6 and 18 MV beams. The estimated total midplane doses were within {+-}5% of the prescribed midplane dose on average except for the lungs where the doses were 6% to 10% lower than the prescribed dose on average. Conclusions: The proposed TBI technique can achieve dose uniformity within {+-}10%. This technique is easy to implement and does not require complicated dosimetry and/or compensators.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the Use of the Polynomial Annihilation Edge Detection for Locating Cracks in Beam-Like Structures

A crack in a structure causes a discontinuity in the first derivative of the mode shapes: On this basis, a numerical method for detecting discontinuities in smooth piecewise functions and their derivatives, based on a polynomial annihilation technique, has been applied to the problem of crack detection and localisation in beam-like structures for which only post-damage mode shapes are available. Using a finite-element model of a cracked beam, the performance of this methodology has been analysed for different crack depths and increasing amounts of noise. Given the crack position, a procedure to estimate its depth is also proposed and corresponding results shown.

Saxena, Rishu↗

Theoretical substantiation of biological efficacy enhancement for β-delayed particle decay {sup 9}C beam: A Monte Carlo study in combination with analysis with the local effect model approach

Purpose: To improve the efficacy of heavy ion therapy, β-delayed particle decay {sup 9}C beam as a double irradiation source for cancer therapy has been proposed. The authors’ previous experiment showed that relative biological effectiveness (RBE) values at the depths around the Bragg peak of a {sup 9}C beam were enhanced and compared to its stable counterpart {sup 12}C beam. The purpose of this study was to explore the nature of the biological efficacy enhancement theoretically. Methods: A Monte Carlo simulation study was conducted in this study. First a simplified cell model was established so as to form a tumor tissue. Subsequently, the tumor tissue was imported into the Monte Carlo simulation software package GATE and then the tumor cells were virtually irradiated with comparable {sup 9}C and {sup 12}C beams, respectively, in the simulations. The transportation and particle deposition data of the {sup 9}C and {sup 12}C beams, derived from the GATE simulations, were analyzed with the authors’ local effect model implementation so as to deduce cell survival fractions. Results: The particles emitted from the decay process of deposited {sup 9}C particles around a cell nucleus increased the dose delivered to the nucleus and elicited clustered damages around the secondary particles’ trajectories. Therefore, compared to the {sup 12}C beam, the RBE value of the {sup 9}C beam increased at the depths around their Bragg peaks. Conclusions: Collectively, the increased local doses and clustered damages due to the decayed particles emitted from deposited {sup 9}C particles led to the RBE enhancement in contrast with the {sup 12}C beam. Thus, the enhanced RBE effect of a {sup 9}C beam for a simplified tumor model was shown theoretically in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-82: Intra-Fraction Proton Beam-Range Verification with PET Imaging: Feasibility Studies with Monte Carlo Simulations and Statistical Modeling

Purpose: To study the feasibility of intra-fraction proton beam-range verification with PET imaging. Methods: Two phantoms homogeneous cylindrical PMMA phantoms (290 mm axial length, 38 mm and 200 mm diameter respectively) were studied using PET imaging: a small phantom using a mouse-sized PET (61 mm diameter field of view (FOV)) and a larger phantom using a human brain-sized PET (300 mm FOV). Monte Carlo (MC) simulations (MCNPX and GATE) were used to simulate 179.2 MeV proton pencil beams irradiating the two phantoms and be imaged by the two PET systems. A total of 50 simulations were conducted to generate 50 positron activity distributions and correspondingly 50 measured activity-ranges. The accuracy and precision of these activity-ranges were calculated under different conditions (including count statistics and other factors, such as crystal cross-section). Separate from the MC simulations, an activity distribution measured from a simulated PET image was modeled as a noiseless positron activity distribution corrupted by Poisson counting noise. The results from these two approaches were compared to assess the impact of count statistics on the accuracy and precision of activity-range calculations. Results: MC Simulations show that the accuracy and precision of an activity-range are dominated by the number (N) of coincidence events of the reconstructed image. They are improved in a manner that is inversely proportional to 1/sqrt(N), which can be understood from the statistical modeling. MC simulations also indicate that the coincidence events acquired within the first 60 seconds with 10{sup 9} protons (small phantom) and 10{sup 10} protons (large phantom) are sufficient to achieve both sub-millimeter accuracy and precision. Conclusion: Under the current MC simulation conditions, the initial study indicates that the accuracy and precision of beam-range verification are dominated by count statistics, and intra-fraction PET image-based beam-range verification is feasible. This work was supported by a research award RP120326 from Cancer Prevention and Research Institute of Texas.

60 APPLIED LIFE SCIENCES↗

Dose Modeling of Noninvasive Image-Guided Breast Brachytherapy in Comparison to Electron Beam Boost and Three-Dimensional Conformal Accelerated Partial Breast Irradiation

Purpose: To perform dose modeling of a noninvasive image-guided breast brachytherapy (NIIGBB) for comparison to electrons and 3DCRT. Methods and Materials: The novel technology used in this study is a mammography-based, noninvasive breast brachytherapy system whereby the treatment applicators are centered on the planning target volume (PTV) to direct {sup 192}Ir emissions along orthogonal axes. To date, three-dimensional dose modeling of NIIGBB has not been possible because of the limitations of conventional treatment planning systems (TPS) to model variable tissue deformation associated with breast compression. In this study, the TPS was adapted such that the NIIGBB dose distributions were modeled as a virtual point source. This dose calculation technique was applied to CT data from 8 patients imaged with the breast compressed between parallel plates in the cranial-caudal and medial-lateral axes. A dose-volume comparison was performed to simulated electron boost and 3DCRT APBI. Results: The NIIGBB PTV was significantly reduced as compared with both electrons and 3DCRT. Electron boost plans had a lower D{sub min} than the NIIGBB technique but higher V{sub 100}, D{sub 90}, and D{sub 50}. With regard to PTV coverage for APBI, the only significant differences were minimally higher D{sub 90}, D{sub 100}, V{sub 80}, and V{sub 90}, with 3DCRT and D{sub max} with NIIGBB. The NIIGBB technique, as compared with electrons and 3D-CRT, achieved a lower maximum dose to skin (60% and 10%, respectively) and chest wall/lung (70-90%). Conclusions: NIIGBB achieves a PTV that is smaller than electron beam and 3DCRT techniques. This results in significant normal tissue sparing while maintaining dosimetric benchmarks to the target tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sheet Beam Klystron Instability Analysis

Using the principle of energy balance we develop a 2D theory for calculating growth rates of instability in a two-cavity model of a sheet beam klystron. An important ingredient is a TE-like mode in the gap that also gives a longitudinal kick to the beam. When compared with a self-consistent particle-in-cell calculation, with sheet beam klystron-type parameters, agreement is quite good up to half the design current, 65 A; at full current, however, other, current-dependent effects come in and the results deviate significantly.

43 PARTICLE ACCELERATORS↗

RHIC injector complex online model status and plans

An online modeling system is being developed for the RHIC injector complex, which consists of the Booster, the AGS and the transfer lines connecting the Booster to the AGS and the AGS to RHIC. Historically the injectors have been operated using static values from design specifications or offline model runs, but tighter beam optics constraints required by polarized proton operations (e.g, accelerating with near-integer tunes) have necessitated a more dynamic system. An online model server for the AGS has been implemented using MAD-X [1] as the model engine, with plans to extend the system to the Booster and the injector transfer lines and to add the option of calculating optics using the Polymorphic Tracking Code (PTC [2]) as the model engine.

43 PARTICLE ACCELERATORS↗

Measurements and Modeling of Coherent Synchrotron Radiation and its Impact on the LCLS Electron Beam

In order to reach the high peak current required for an x-ray free electron laser, two separate magnetic dipole chicanes are used in the Linac Coherent Light Source (LCLS) accelerator to compress the electron bunch length in stages. In these bunch compressors, coherent synchrotron radiation (CSR) can be emitted either by a short electron bunch or by any longitudinal density modulation that may be on the bunch. In this paper, we report detailed measurements of the CSR-induced energy loss and transverse emittance growth in these compressors. Good agreement is found between the experimental results and multi-particle tracking studies. We also describe direct observations of CSR at optical wavelengths and compare with analytical models based on beam microbunching.

43 PARTICLE ACCELERATORS↗

Radiation shielding for the Main Injector collimation system

The results of Monte Carlo radiation shielding studies performed with the MARS15 code for the Main Injector collimation system are presented and discussed. A Proton Plan was developed recently at Fermilab for the benefit of the existing neutrino programs as well as to increase anti-proton production for the Tevatron programs [1]. As a part of the plan, the intensity of proton beams in the Main Injector (MI) should be increased by means of slip-stacking injection. In order to localize beam loss associated with the injection, a collimation system was designed [2] that satisfies all the radiation and engineering constraints. The system itself comprises a primary collimator and four secondary ones to which various masks are added. It is assumed that beam loss at the slip-stacking injection is equal to 5% of total intensity which is 5.5 x 10{sup 13} protons per pulse [2]. As far as pulse separation is 2.2 seconds, one has (5.5 x 10{sup 13}/2.2) x 0.05 = 1.25 x 10{sup 12} protons interacting per second with the primary collimator. In the paper the geometry model of the corresponding MI region and beam loss model are described. The model of the region was built by means of the MAD-MARS Beam Line Builder (MMBLB) [3] using results of the collimation studies [2]. The results of radiation shielding calculations performed with the MARS15 code [4] are presented.

43 PARTICLE ACCELERATORS↗

Structure–performance relationships for cantilever-type piezoelectric energy harvesters

This study provides comprehensive analysis of the structure–performance relationships in cantilever-type piezoelectric energy harvesters. It provides full understanding of the effect of all the practical global control variables on the harvester performance. The control variables considered for the analysis were material parameters, areal and volumetric dimensions, and configuration of the inactive and active layers. Experimentally, the output power density of the harvester was maximum when the shape of the beam was close to a square for a constant bending stiffness and a fixed beam area. Through analytical modeling of the effective stiffness for the piezoelectric bimorph, the conditions for enhancing the bending stiffness within the same beam volume as that of a conventional bimorph were identified. The harvester configuration with beam aspect ratio of 0.86 utilizing distributed inactive layers exhibited an giant output power of 52.5 mW and power density of 28.5 mW cm{sup −3} at 30 Hz under 6.9 m s{sup −2} excitation. The analysis further indicates that the trend in the output power with varying damping ratio is dissimilar to that of the efficiency. In order to realize best performance, the harvester should be designed with respect to maximizing the magnitude of output power.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A model for radio emission from solar coronal shocks

Solar coronal shocks are very common phenomena in the solar atmosphere and are believed to be the drivers of solar type II radio bursts. However, the microphysical nature of these emissions is still an open question. This paper proposes that electron cyclotron maser (ECM) emission is responsible for the generation of radiation from the coronal shocks. In the present model, an energetic ion beam accelerated by the shock first excites the Alfvén wave (AW), then the excited AW leads to the formation of a density-depleted duct along the foreshock boundary of the shock. In this density-depleted duct, the energetic electron beam produced via the shock acceleration can effectively excite radio emission by ECM instability. Our results show that this model may potentially be applied to solar type II radio bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

Space Induced Discharge Model to Be Used on Interface Circuit Vulnerability Assessment

Charging can occur in space due to plasma and high energy particles. Charging is especially severe in certain earth orbits such as geostationary orbit, medium earth orbit and highly inclined orbit. A spacecraft that travels to other planets such as Jupiter also encounters high level of charging due to Jupiter’s radiation belt. The major concern for spacecraft operation due to charging is the survival of sensitive electrical circuits. Dielectrics and floating metal can charge up and discharge onto interface circuits. The electrical circuits need to be evaluated for survival from the electrostatic-discharge (ESD) threat. Both ESD induced upset and damage need to be assessed. The interface circuits are often located inside a shielded unit in the spacecraft structure or a shielded vault with sufficient radiation shielding to avoid surface and internal charging. The materials external to the highly shielded area can charge up and discharge onto wires that can directly dissipate the ESD onto the interface circuits. Figure 1 shows a possible discharge mechanism onto the interfacing circuits. If the wire has an external shield or a coaxial line, some or most of the discharge can flow on the shield to chassis ground. There is always coupling from external discharge. If the wire has no shield, the discharge flows onto the interface circuit. Fig. 1 Possible discharge paths onto the interface circuits. The purpose of this article is to address how to model the ESD threat to be used as the discharge source onto the interface circuit based on the electron beam test data. Different models are needed for different impedances associated with the interface circuits. Once those models are derived, one needs to analyze the interface circuit with the corresponding model using an electrical simulation tool. Then, the circuit’s front-end components can be assessed for damage and upset. Upset is highly dependent on the circuit operation and system requirements, and thus it is not addressed any further. Damage of electrical parts is often rated under Human-Body-Model (HBM) ESD. One can utilize this industry-wide available information to assess the damage vulnerability due to space discharges. However, the HBM waveform does not always match the discharge waveform. To estimate the damage vulnerability of the circuit and set margin, one needs to compare the equivalent energy delivered to the victim between a HBM discharge and the results from an ESD source model based on actual discharges. This paper presents such a comparison for a few select cases.

Xie, Julie↗

Electroexcitation of the Roper resonance from CLAS data

The helicity amplitudes of the electroexcitation of the Roper resonance on proton are extracted at $1.7<4.2~GeV^2$ from recent high precision JLab-CLAS cross sections data and longitudinally polarized beam asymmetry for $\pi^+$ electroproduction on protons. The analysis is made using two approaches, dispersion relations and unitary isobar model, which give consistent results. It is found that the transverse helicity amplitude for the $\gamma^* p\rightarrow P_{11}(1440)$ transition, which is large and negative at $Q^2=0$, becomes large and positive at $Q^2\simeq 2~GeV^2$, and then drops slowly with $Q^2$. Longitudinal helicity amplitude, that was previously found from CLAS data as large and positive at $Q^2=0.4,~0.65~GeV^2$, drops with $Q^2$. These results rule out the presentation of $P_{11}(1440)$ as a $q^3G$ hybrid state, and provide strong evidence in favor of this resonance as a first radial excitation of the $3q$ ground state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute wind measurements in the lower thermosphere of Venus using infrared heterodyne spectroscopy

The first absolute wind velocities above the Venusian cloud-tops were obtained using NASA/Goddard infrared heterodyne spectrometers at the NASA Infrared Telescope Facility (IRTF) and the McMath Solar Telescope. Beam-integrated Doppler displacements in the non-thermal emission core of (12)C(16)O2 10.33 micron R(8) sampled the line of sight projection of the lower thermospheric wind field (100 to 120 km). A field-usable Lamb-dip laser stabilization system, developed for spectrometer absolute frequency calibration to less than + or - 0.1 MHz, allowed S/N-limited line of sight velocity resolution at the 1 m/s level. The spectrometer's diffraction-limited beam (1.7 arc-second HPBW at McMath, 0.9 arc-second HPBW at IRTF), and 1 to 2 arc-second seeing, provided the spatial resolution necessary for circulation model discrimination. Qualitative analysis of beam-integrated winds provided definitive evidence of a dominant subsolar-antisolar circulation in the lower thermosphere. Beam-integrated winds were modelled with a 100x100 grid over the beam, incorporating beam spatial rolloff and across-the-beam gradients in non-thermal emission intensity, line of sight projection geometry, and horizontal wind velocity. Horizontal wind velocity was derived from a 2-parameter model wind field comprised of subsolar-antisolar and zonal components. Best-fit models indicated a dominant subsolar-antisolar flow with 120 m/s cross-terminator winds and a retrograde zonal component with a 25 m/s equatorial velocity. A review of all dynamical indicators above the cloud-tops allowed development of an integrated and self-consistent picture of circulation in the 70 to 200 km range.

Goldstein, Jeffrey J.↗

A unique signal of excited bosons in dijet data from pp collisions

With this note we would like to draw attention to a possible novel signal of new physics in dijet data at the hadron colliders. Usually it is accepted that almost all exotic models predict that these two jets populate the central (pseudo)rapidity region where y{sub 1,2} {approx_equal} 0. Contrary, the excited bosons do not contribute into this region, but produce an excess of dijet events over the almost flat QCD background in {chi} = exp vertical bar y{sub 1}-y{sub 2} vertical bar away from this region. For the special choice of parameters this could lead to a dip in the centrality ratio distribution over the dijet invariant mass instead of a bump, expected for the most exotic models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Propagation Through Atmospheric Turbulence Using an Altitude-Dependent Structure Profile with Non-Uniformly Distributed Phase Screens

For free-space optical communication systems, numerical wave optics simulations provide a useful technique for modeling turbulence-induced beam degradation when the analytical theory is insufficient for characterizing the atmospheric channel. Motivated by such applications we use a split-step method modeling the turbulence as a series of random phase screens using the Hufnagel-Valley turbulence profile. We employ a space-to-ground case study to examine the irradiance and phase statistics for uniformly and non-uniformly located screens and find better agreement with theory using a non-uniform discretization minimizing the contribution of each screen to the total scintillation. In this poster, we summarize the method and the results of the case study including a comparison to layered models used in astronomical imaging applications.

Chahine, Yousef K.↗

Potential formation in front of an electron emitting electrode immersed in a plasma that contains a monoenergetic electron beam

A one-dimensional fluid model of the sheath formation in front of a large, planar electron emitting electrode (collector) immersed in a plasma that contains a monoenergetic electron beam is presented. Expressions for the Bohm criterion, the total electric current to the collector, and for the zero electric field at the collector are derived. When there is no electron emission, the model predicts, in some cases, up to three different solutions. The low and the high solutions correspond to the fact that the presheath potential drop can be determined either by thermal or by the beam electrons. The middle solution between them has no physical meaning. When the electron emission is space charge limited, the model may have up to five solutions because the low solution can sometimes split into three parts. The current-voltage characteristic of the collector that exhibits triple floating potential is calculated and it shows qualitative similarity with experimental ones [C.-H. Nam et al., J. Appl. Phys. 63, 5674 (1988)]. When the emission is below the space charge limit, the model again exhibits up to five solutions, which are the low, middle, high, and two additional 'singularity solutions'. These two appear because of the singularity in the Bohm criterion. Regions of validity of the low and high solutions are determined from numerical solutions of the Poisson equation [T. Gyergyek et al., Plasma Sources Sci. Technol. 18, 035001 (2009)] and with the maximum positive ion flux test [J. I. Fernandez Palop et al., J. Appl. Phys. 91, 2587 (2002)]. In the case of no or small emission, both methods give the same results. If the emission is space charge limited, the numerical solution method is much more reliable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

H-mode Accelerating Structures with PMQ Focusing for Low-Beta Beams

We report on results of the project developing high-efficiency normal-conducting RF accelerating structures based on inter-digital H-mode (IH) cavities and the transverse beam focusing with permanent-magnet quadrupoles (PMQ), for beam velocities in the range of a few percent of the speed of light. The shunt impedance of IH-PMQ structures is 10-20 times higher than that of a conventional drift-tube linac, while the transverse size is 4-5 times smaller. The H-PMQ accelerating structures following a short RFQ can be used both in the front end of ion linacs or in stand-alone applications. Results of the combined 3-D modeling -- electromagnetic computations, beam-dynamics simulations with high currents, and thermal-stress analysis -- for a full IH-PMQ accelerator tank are presented. The accelerating field profile in the tank is tuned to provide the best propagation of a 50-mA deuteron beam using coupled iterations of EM and beamdynamics modeling. Multi-particle simulations withParmela and CST Particle Studio have been used to confirm the design. Measurement results of a cold model of the IH-PMQ tank are presented.

Accelerator Design, Technology, and Operations↗