Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “baselining”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Baseline Graphite Characterization

Select necessary material properties Apply sampling plan Perform standardized testing Evaluate/compare properties Build NQA-1 qualified database Apply the “system” and database to the evaluation and qualification of future grades of graphite

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Baseline Emissions Measurements from Reciprocating Compressor Packing

A novel liquid reciprocating compressor packing seal concept is being developed to reduce methane emissions from reciprocating compressor packing by 95%. To provide the leakage basis for this project, a benchmark test was performed to measure the leakage from a 50Hp Ariel reciprocating compressor that will be used for the testing comparisons throughout the project. Brand-new packing replacement parts were installed to minimize leakage that could be due to worn internals and rings

03 NATURAL GAS↗

Study of Spherical Array Target for Long-Baseline Neutrino Experiment

Spherical Array Target was studied by implementing the geometry in LBNE's Beam Simulation source code g4lbne version v3r2p4 and Monte Carlo. To compare with Nominal LBNE target, unoscillated Far Detector neutrino flux was produced using different parameters: sphere diameter 17mm and 13mm, different longitudinal positions, two interaction length and less, beam size R/3 and 1.7mm, and beam offset from 50 $\mu$m to 1mm. The 1.86 interaction length (901mm), 17mm diameter target, with beam size 1.7mm gives higher $\nu_{\mu}$ flux up to 10% from 0-3.5 GeV, and suppresses flux up to 70% at energy higher than 3.5 GeV.

43 PARTICLE ACCELERATORS↗

A Systematic Study to Determine 5G Baseline Performance for Scientific Computing

The fifth-generation (5G) cellular networks envisions achieving higher data rates, improved connectivity, reduced latency, and better quality of service (QoS) than the fourthgeneration (4G) cellular networks. Such improved performance can be utilized to address the challenges in applications such as electricity generation in power systems. The traditional power grids responsible for electricity generation suffer from drawbacks such as life-threatening blackout crises, and energy storage proliferation as they are not robust to extreme climatic conditions. A recent study proposed the idea of extending the capabilities of advanced wireless technologies such as the current 5G to develop a robust, energy-efficient, and secure smart grids. However there are two main challenges associated with the integration of power systems and wireless technologies. First, it is imperative to understand the architecture and the enabling technologies of 5G to ensure that the performance requirements of the smart grids are met. Second, an end-to-end testbed is required to determine if the performance requirements are met by estimating the 5G characteristics such as latency, and throughput. Our proposed alleviates the aforementioned concerns in the following manner. To begin with, a systematic study of the 5G architecture including both the StandAlone (SA) and Non-Standalone (NSA) operations is presented. Furthermore, a detailed survey of the possible 5G enabling technologies is elicited. In addition to these, an end-toend testbed that can estimate the 5G characteristics is explained in detail with appropriate preliminary results.

5G, 5G Communication↗

Assessment of preliminary results of baseline high entropy alloys manufactured at INL

Materials development is needed to support the design and deployment of advanced nuclear reactors that will operate at higher temperatures and in harsher environments than the current light water reactor fleet. High entropy alloys have been identified as a class of alloy that could address the needs of advanced reactors, such as the molten salt reactors, due to their potential strength, radiation resistance, and corrosion resistance. This project summarizes the work done in fiscal year 2024 for the Additive Manufacturing of High Entropy Alloys for Nuclear Applications Project. This work has focused on examination of potential alloy compositions, down selection based on simulated results, and preliminary testing of down selected alloys.

36 MATERIALS SCIENCE↗

NOvA Dual-Baseline Search for Active-to-Sterile Neutrino Oscillations using Neutrino- and Antineutrino-Enriched Samples

We report a search for neutrino oscillations to sterile neutrinos in the NOvA detectors under a model with three active and one sterile neutrinos. This search simultaneously fits data in the two NOvA detectors and is the first from NOvA to use both neutrino- and antineutrino-mode beams, with exposures of $26.61\times10^{20}$ and $12.50\times10^{20}$ protons on target, respectively. There is no evidence for sterile neutrinos in the data and we are able to exclude regions of parameter space that were allowed by previous experiments, including most of the allowed region reported by IceCube.

Abubakar, S. [Erciyes U.]↗

Long Baseline Neutrino Oscillations

There is compelling evidence for neutrino flavor change as neutrinos propagate. The evidence for this phenomenon has been provided by several experiments observing neutrinos that traverse distances of several hundred kilometers between production and detection. This review outlines the evidence for neutrino flavor change from such experiments and describes recent results in the field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Muon Neutrino Disappearance in a Short-Baseline Accelerator Neutrino Beam

We report a search for muon neutrino disappearance in the {Delta}m{sup 2} region of 0.5--40 eV{sup 2} using data from both Sci-BooNE and MiniBooNE experiments. SciBooNE data provides a constraint on the neutrino flux, so that the sensitivity to {nu}{sub {mu}} disappearance with both detectors is better than with just MiniBooNE alone. The preliminary sensitivity for a joint {nu}{sub {mu}} disappearance search is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of Dynamic Aperture of PEP-X Baseline Design

SLAC is developing a long-range plan to transfer the evolving scientific programs at SSRL from the SPEAR3 light source to a much higher performing photon source. Storage ring design is one of the possibilities that would be housed in the 2.2-km PEP-II tunnel. The design goal of PEPX storage ring is to approach an optimal light source design with horizontal emittance less than 100 pm and vertical emittance of 8 pm to reach the diffraction limit of 1-{angstrom} x-ray. The low emittance design requires a lattice with strong focusing leading to high natural chromaticity and therefore to strong sextupoles. The latter caused reduction of dynamic aperture. The dynamic aperture requirement for horizontal injection at injection point is about 10 mm. In order to achieve the desired dynamic aperture the transverse non-linearity of PEP-X is studied. The program LEGO is used to simulate the particle motion. The technique of frequency map is used to analyze the nonlinear behavior. The effect of the non-linearity is tried to minimize at the given constrains of limited space. The details and results of dynamic aperture optimization are discussed in this paper.

43 PARTICLE ACCELERATORS↗

Crustal dynamics project session 4 validation and intercomparison experiments 1979-1980 report

As part of the Crustal Dynamics Project, an experiment was performed to verify the ability of Satellite Laser Ranging (SLR), Very Long Baseline interferometry (VLBI) and Doppler Satellite Positioning System (Doppler) techniques to estimate the baseline distances between several locations. The Goddard Space Flight Center (GSFC) lasers were in operation at all five sites available to them. The ten baselines involved were analyzed using monthly orbits and various methods of selecting data. The standard deviation of the monthly SLR baseline lengths was at the 7 cm level. The GSFC VLBI (Mark III) data was obtained during three separate experiments. November 1979 at Haystack and Owens Valley, and April and July 1980 at Haystack, Owens Valley, and Fort Davis. Repeatability of the VLBI in determining baseline lengths was calculated to be at the 2 cm level. Jet Propulsion Laboratory (JPL) VLBI (Mark II) data was acquired on the Owens Valley to Goldstone baseline on ten occasions between August 1979 and November 1980. The repeatability of these baseline length determinations was calculated to be at the 5 cm level. National Geodetic Survey (NGS) Doppler data was acquired at all five sites in January 1980. Repeatability of the Doppler determined baseline lengths results were calculated at approximately 30 cm. An intercomparison between baseline distances and associated parameters was made utilizing SLR, VLBI, and Doppler results on all available baselines. The VLBI and SLR length determinations were compared on four baselines with a resultant mean difference of -1 cm and a maximum difference of 12 cm. The SLR and Doppler length determinations were compared on ten baselines with a resultant mean difference of about 30 cm and a maximum difference of about 60 cm. The VLBI and Doppler lengths from seven baselines showed a resultant mean difference of about 30 cm and maximum difference of about 1 meter. The intercomparison of baseline orientation parameters were consistent with past analysis.

Liebrecht, P.↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanism Design for Demand Response Programs

Demand response (DR) programs serve to reduce the consumption of electricity at times when the supply is scarce and expensive. Consumers or agents with flexible consumption profiles are recruited by an aggregator who manages the DR program. The aggregator calls on a subset of its pool of recruited agents to reduce their electricity use during DR events. Agents are paid for reducing their energy consumption from contractually established baselines. Baselines are counter-factual consumption estimates of the energy an agent would have consumed if they were not participating in the DR program. Baselines are used to determine payments to agents. This creates an incentive for agents to inflate their baselines in order to increase the payments they receive. There are several newsworthy cases of agents gaming their baseline for economic benefit. We propose a novel self-reported baseline mechanism (SRBM) where each agent reports its baseline and marginal utility. These reports are strategic and need not be truthful. Based on the reported information, the aggregator selects or calls on agents with a certain probability to meet the load reduction target. Called agents are paid for observed reductions from their self-reported baselines. Agents who are not called face penalties for consumption shortfalls below their baselines. Under SRBM, we show that truthful reporting of baseline consumption and marginal utility is a dominant strategy. Thus, SRBM eliminates the incentive for agents to inflate baselines. SRBM is assured to meet the load reduction target. To conclude, we show that SRBM is almost optimal in the metric of average cost of DR provision faced by the aggregator.

24 POWER TRANSMISSION AND DISTRIBUTION↗