Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Fabrication of In2O3/TiO2 nanotube arrays hybrids with homogeneously developed nanostructure for photocatalytic degradation of Rhodamine B

Highlights: • A new class of plate-like In{sub 2}O{sub 3}/TNAs photocatalyst is successfully fabricated. • The obtained In{sub 2}O{sub 3}/TNAs hybrid presents a well-aligned nanotubular structure. • In{sub 2}O{sub 3} particles are dispersed homogeneously on TNAs without blocking the nozzles. • In{sub 2}O{sub 3}/TNAs hybrid shows a much enhanced Rhodamine B degradation efficiency. • In{sub 2}O{sub 3}/TNAs hybrid demonstrates an excellent recycling capability. - Abstract: To enhance the photocatalytic recycling capability of the TiO{sub 2}-based photocatalysts, a new kind of plate-like In{sub 2}O{sub 3}/TiO{sub 2} nanotube array (TNA) hybrids is fabricated herein by constructing TNAs via an anodization method followed by doping In{sub 2}O{sub 3} via a solvothermal method. The obtained In{sub 2}O{sub 3}/TNA hybrid demonstrates a well-aligned nanotubular structure with homogeneous dispersion of In{sub 2}O{sub 3} nanoparticles. It shows a much higher degradation rate of 77% after 2 h compared to TNA (37%). In addition, the plate-like feature endows the photocatalysts with an excellent recycling capability. These superior photocatalytic degradation performances can be ascribed to the following factors: (1) the enhanced light absorption ability and efficient separation of photoexcited electron-hole pairs derived from the formation of the heterostructure between the interface of TiO{sub 2} and In{sub 2}O{sub 3}; (2) the efficient transport of reactant molecules provided by the well-defined TNAs and the homogeneous distribution of the In{sub 2}O{sub 3} nanoparticles without blocking the nanotubes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Upconversion Er-doped TiO2 nanorod arrays for perovskite solar cells and the performance improvement

Highlights: • Er-doped TiO{sub 2} nanorod absorbs IR and converts into visible light. • The introduction of Er could make a positive shift in flat-band potential. • Er-doped TiO{sub 2} solar cells show a 20% increment in the current density. - Abstract: Upconversion erbium-doped rutile TiO{sub 2} nanorod arrays were synthesized by a facile process and applied in perovskite solar cells (PSCs). The structure was characterized by X-ray powder diffraction (XRD). Energy dispersive spectrometer (EDS) and Tauc plot indicated that Er was successfully introduced and changed TiO{sub 2} band gap from 3.00 eV to 3.07 eV. The incorporation of Er shifts the flat band potential positively and enhances the electron density. The Er-doped TiO{sub 2} nanorods have a broad absorption in the infrared light and up-convert it into visible light, which provides a possibility for PSCs to use NIR light for higher performance. A higher photocurrent density (J{sub sc}) of 22.97 mA/cm{sup 2} and a power conversion efficiency (PCE) of 10.6% were obtained, showing 20% and 16.5% increment in J{sub sc} and PCE, respectively, when compared with the un-doped device. The performance improvement was ascribed to the upconversion performance, enhanced electron-injection efficiency and reduced charge recombination.

14 SOLAR ENERGY↗

A new time calibration method for switched-capacitor-array-based waveform samplers

Here we have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. Ultimately, the new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The performance of the γ-ray tracking array GRETINA for γ-ray spectroscopy with fast beams of rare isotopes

The gamma-ray tracking array GRETINA was coupled to the S800 magnetic spectrometer for spectroscopy with fast beams of rare isotopes at the National Superconducting Cyclotron Laboratory on the campus of Michigan State University. We describe the technical details of this powerful setup and report on GRETINA's performance achieved with source and in-beam measurements. The gamma-ray multiplicity encountered in experiments with fast beams is usually low, allowing for a simplified and efficient treatment of the data in the gamma-ray analysis in terms of Doppler reconstruction and spectral quality. Finally, the results reported in this work were obtained from GRETINA consisting of 8 detector modules hosting four high-purity germanium crystals each. Currently, GRETINA consists of 10 detector modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KALYPSO: Linear array detector for high-repetition rate and real-time beam diagnostics

Synchrotrons and modern FEL light sources operate with bunch repetition rates in the MHz range. The profile of the electron beam inside the accelerator can be characterized with indirect experimental techniques where linear array detectors are employed to measure the emitted synchrotron radiation or the spectrum of a near-IR laser. To improve the performance of modern beam diagnostics we have developed KALYPSO, a detector system operating with a continuous frame rate of up to 2.7 MHz. To facilitate the integration in different experiments, a modular architecture has been adopted. Different semiconductor micro-strip sensors can be connected to front-end ASICs to optimize the quantum efficiency at different photon energies, ranging from visible light up to near-IR. The front-end electronics are integrated within an heterogeneous DAQ consisting of FPGAs and GPUs, which allows scientists to implement real-time data processing algorithms. The current version of the detector is in operation at the KARA synchrotron light source and at the European XFEL. Finally, in this contribution we present the detector architecture, the performance results and the on-going technical developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and description of a spectrum unfolding method for the $\mathrm{CATRiNA}$ neutron detector array

We report the CATRiNA deuterated neutron detector array at Florida State University consists of 16 2" x 2" and 16 $" x 2" EJ-315 detectors with characteristic light output and pulse-shape discrimination capabilities. The unique properties of the detectors, in part due to the anisotropic nature of (d,n) scattering, are used to extract the energy of neutrons via pulse-height spectrum unfolding. The unfolding method uses the light output and response matrix of the detectors to extract neutron energies, independent of the traditional time-of-flight (ToF) technique. Detailed response matrices of the CATRiNA detectors were measured at the Edwards Accelerator Laboratory at Ohio University via the 9 Be(d,n) and 27 Al(d,n) reactions. Full characterization of the detectors using digital electronics, as well as a description of the unfolding method are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Elevation Radiation Array (HERA) detectors for airborne thunderstorm investigations

A high-energy atmospheric physics phenomenon, referred to as a terrestrial gamma ray flash (TGF), is associated with lightning and produces large bursts of energetic photon radiation. TGFs will be investigated using a suite of gamma-ray instruments designed and constructed to fly on ten United States Air Force (USAF) WC-130J Hurricane Hunter aircraft as part of an aircrew ionization study led by the Air Force Institute of Technology (AFIT) and the United States Air Force School of Aerospace Medicine (USAFSAM), in cooperation with the 53rd Weather Reconnaissance Squadron (WRS). Each instrument consists of one NaI and one plastic detector, a GPS timing device, and an instrument computer that performs data acquisition. High Elevation Radiation Array (HERA) detectors will be employed to maximize the chances of observing TGFs near their source and to gain a better understanding of their origin, mechanism, ubiquity, and to assess potential hazards posed to military and commercial aircrew and passengers. The HERA program, deployed on 10 separate Air Force aircraft over a multi-year campaign, will result in thousands of observational flight hours and be the largest concerted effort to date to observe TGFs in situ through aircraft observations. In this paper, we give an overview of the scientific goals of this campaign and how the HERA instruments have been designed to meet those goals. Here, we include a detailed description of the HERA instrument, along with mass model and signal processing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each 2.5 x 2.5 x 18 cm 3 crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30–100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. Here, as an example of the results, the energy resolution at 70 MeV of (1.52 ± 0.03) % is more than two times better than reported results using previous generation LYSO crystals.

Electromagnetic calorimeter↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Methodology for inferring reactor core power distribution from an optical fiber based gamma thermometer array

Here, a 4-step data analytic methodology has been devised for the purpose of inferring the distribution of power in a reactor core, based on the response of an array of optical fiber based gamma thermometers (OFBGTs). This data analytic methodology is crucial for the development of a system of OFBGTs for the purpose of calibrating local power range monitors in boiling water reactors. Such a system would be an improvement to the present calibration system in boiling water reactors, in terms of safety, efficiency, and permanence. The first step of this methodology is to establish an energy balance method. In this method, one uses MCNP to determine response functions, which allow one to convert from gamma thermometer response to power. The gamma thermometers and the reactor core are segmented, such that each gamma thermometer segment provides an estimate of power for each reactor core segment. The estimates of power for the reactor core segments (hereafter referred to as fuel assembly segments) are calculated based on the measured response of the gamma thermometers. The second step of the methodology is to employ a weighting scheme to combine the estimates of the power of the various fuel assembly segments, based on the response of the various OFGBT segments and the incremental dose rates of the various fuel assembly segments to the OFBGT segments. The third step is to iteratively calculate the estimates of the power of the fuel assembly segments, until a convergence criterion is met, which indicates that the calculation has converged. The fourth and final step of the methodology is to estimate the uncertainty of the power for each fuel assembly segment. The mathematical basis for this step is not the focus of this paper. We have used a 3-D homogeneous reactor model to demonstrate the data analytic methodology; and have found that the data analytic methodology operates as intended.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Array-based Hierarchical Mesh Generation in Parallel

In this paper, we describe an array-based hierarchical mesh generation capability through uniform refinement of unstructured meshes for efficient solution of PDE's using finite element methods and multigrid solvers. A multi-degree, multi-dimensional and multi-level framework is designed to generate the nested hierarchies from an initial mesh that can be used for a number of purposes such as multi-level methods to generating large meshes. The capability is developed under the parallel mesh framework “Mesh Oriented dAtaBase” a.k.a MOAB. We describe the underlying data structures and algorithms to generate such hierarchies and present numerical results for computational efficiency and mesh quality. In conclusion, we also present results to demonstrate the applicability of the developed capability to a multigrid finite-element solver.

97 MATHEMATICS AND COMPUTING↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of impact to optical environment of the land by flat-plate and array of tracking PV panels

The impact to the optical environment result from shading of PV panels becomes concerned. This paper describes how to calculate illumination level on the land around tracking PV (both isolated and arrayed) panel. The land under the flat-plate PV is dark by shading, but the influence from the tracking PV is not very significant, typically half in average. This is because shadow by tracking panel moves. The shading influence is further decreased with the increase of pedestal height. We report with this advantage, tracking PV can be combined with agriculture as a double use of the land.

14 SOLAR ENERGY↗

High-throughput cardiac safety evaluation and multi-parameter arrhythmia profiling of cardiomyocytes using microelectrode arrays

Microelectrode arrays (MEAs) recording extracellular field potentials of human-induced pluripotent stem cell-derived cardiomyocytes (hiPS-CM) provide a rich data set for functional assessment of drug response. The aim of this work is the development of a method for a systematic analysis of arrhythmia using MEAs, with emphasis on the development of six parameters accounting for different types of cardiomyocyte signal irregularities. We describe a software approach to carry out such analysis automatically including generation of a heat map that enables quick visualization of arrhythmic liability of compounds. We also implemented signal processing techniques for reliable extraction of the repolarization peak for field potential duration (FPD) measurement even from recordings with low signal to noise ratios. We measured hiPS-CM's on a 48 well MEA system with 5 minute recordings at multiple time points (0.5, 1, 2 and 4 h) after drug exposure. We evaluated concentration responses for seven compounds with a combination of hERG, QT and clinical proarrhythmia properties: Verapamil, Ranolazine, Flecainide, Amiodarone, Ouabain, Cisapride, and Terfenadine. The predictive utility of MEA parameters as surrogates of these clinical effects were examined. The beat rate and FPD results exhibited good correlations with previous MEA studies in stem cell derived cardiomyocytes and clinical data. The six-parameter arrhythmia assessment exhibited excellent predictive agreement with the known arrhythmogenic potential of the tested compounds, and holds promise as a new method to predict arrhythmic liability. - Highlights: • Six parameters describing arrhythmia were defined and measured for known compounds. • Software for efficient parameter extraction from large MEA data sets was developed. • The proposed cellular parameter set is predictive of clinical drug proarrhythmia.

60 APPLIED LIFE SCIENCES↗

Field Programmable Gate Arrays for Enhancing the Speed and Energy Efficiency of Quantum Dynamics Simulations

We present the first application of field programmable gate arrays (FPGAs) as new, customizable hardware architectures for carrying out fast and energy-efficient quantum dynamics simulations of large chemical/material systems. Instead of tailoring the software to fixed hardware, which is the typical case for writing quantum chemistry code for central processing units (CPUs) and graphics processing units (GPUs), FPGAs allow us to directly customize the underlying hardware (even at the level of specific electrical signals in the circuit) to give a truly optimized computational performance for quantum dynamics calculations. By offloading the most intensive and repetitive calculations onto an FPGA, we show that the computational performance of our real-time electron dynamics calculations can even exceed that of optimized commercial mathematical libraries running on high-performance GPUs. In addition to this impressive computational speedup, we show that FPGAs are immensely energy-efficient and consume 4 times less energy than modern GPU or CPU architectures. These energy savings are a practical and important metric for supercomputing centers (many of which exceed over $1 million in power costs alone), as exascale computing capabilities become more widespread and commonplace. Taken together, the implementation techniques and performance metrics of our study demonstrate that FPGAs could play a promising role in upcoming quantum chemistry and materials science applications, particularly for the acceleration and energy-efficient execution of quantum dynamics calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum Symmetry Breaking of Exciton/Polaritons in a Metal-Nanorod Plasmonic Array

We study the collective, superradiant behavior in the system of emitter-dressed Ag nanorods. Starting from the Drude model for the plasmon oscillations, we arrive at a semi-empirical Hamiltonian describing the coupling between quantized surface plasmon modes and the quantum emitters that can be controlled by manipulating their geometry, spacing, and orientation. Further, identifying the lowest polariton mode as SPstates dressed by excitons in the vicinity of k = 0, we examine conditions allowing for the polariton quantum phase transition. While the system is formally a 1D array, we show that the polariton states of interest can undergo a quantum phase transition to form a Bose condensate at finite temperatures for physically accessible parameter ranges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volatilization Behavior of Supported Au Nanoparticle Arrays under H 2 at High Temperature

In this work, the fabrication and experimental study of model Au nanoparticle arrays (nanodots) was used to allow a direct comparison of reactive evaporation at elevated temperatures and nonambient H 2 -containing gas atmospheres with theoretical models. Strong temperature and H 2 -concentration dependencies were confirmed as expected, and the observed dependence in particle diameter with time was effectively described using a reactive evaporation and gas phase diffusion based quantitative model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗