Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arms control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

N08C9 (Alliance): A Phase 3 Randomized Study of Sulfasalazine Versus Placebo in the Prevention of Acute Diarrhea in Patients Receiving Pelvic Radiation Therapy

Purpose: To provide confirmatory evidence on the use of sulfasalazine to reduce enteritis during pelvic radiation therapy (RT), following 2 prior single-institution trials suggestive that benefit existed. Methods and Materials: A multi-institution, randomized, double-blind, placebo-controlled phase 3 trial was designed to assess the efficacy of sulfasalazine versus placebo in the treatment of RT-related enteritis during RT including the posterior pelvis (45.0-53.5 Gy) and conducted through a multicenter national cooperative research alliance. Patients received 1000 mg of sulfasalazine or placebo orally twice daily during and for 4 weeks after RT. The primary endpoint was maximum severity of diarrhea (Common Terminology Criteria for Adverse Events version 4.0). Toxicity and bowel function were assessed by providers through a self-administered bowel function questionnaire taken weekly during RT and for 6 weeks afterward. Results: Eighty-seven patients were enrolled in the trial between April 29, 2011, and May 13, 2013, with evenly distributed baseline factors. At the time of a planned interim toxicity analysis, more patients with grade ≥3 diarrhea received sulfasalazine than received placebo (29% vs 11%, P=.04). A futility analysis showed that trial continuation would be unlikely to yield a positive result, and a research board recommended halting study treatment. Final analysis of the primary endpoint showed no significant difference in maximum diarrhea severity between the sulfasalazine and placebo arms (P=.41). Conclusions: Sulfasalazine does not reduce enteritis during pelvic RT and may be associated with a higher risk of adverse events than placebo. This trial illustrates the importance of confirmatory phase 3 trials in the evaluation of symptom-control agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1 Study of Ipilimumab Combined With Whole Brain Radiation Therapy or Radiosurgery for Melanoma Patients With Brain Metastases

Purpose: We performed a phase 1 study to determine the maximum tolerable dose and safety of ipilimumab with stereotactic radiosurgery (SRS) or whole brain radiation therapy (WBRT) in patients with brain metastases from melanoma. Methods and Materials: Based on the intracranial disease burden, patients underwent WBRT (arm A) or SRS (arm B). The ipilimumab starting dose was 3 mg/kg every 3 weeks, starting on day 3 of WBRT or 2 days after SRS. The ipilimumab dose was escalated to 10 mg/kg using a 2-stage, 3+3 design. The primary endpoint was to determine the maximum tolerable dose of ipilimumab combined with radiation therapy. The secondary endpoints were overall survival, intracranial and extracranial control, progression-free survival, and toxicity. The (ClinicalTrials.gov) registration number is (NCT01703507). Results: The characteristics of the 16 patients enrolled between 2011 and 2014 were mean age, 60 years; median number of brain metastases, 2 (range 1->10); and number with EC disease, 13 (81%). Treatment included WBRT (n=5), SRS (n=11), and ipilimumab 3 mg/kg (n=7) or 10 mg/kg (n=9). The median follow-up was 8 months (arm A) and 10.5 months (arm B). A total of 21 grade 1 to 2 neurotoxic effects occurred, with no dose-limiting toxicities. One patient experienced grade 3 neurotoxicity before ipilimumab administration. Ten additional grade 3 toxicities were reported, with gastrointestinal toxicities (n=5; 31%) the most common. No patient developed grade 4 or 5 toxicity. The median progression-free survival and overall survival in arm A was 2.5 months and 8 months and in arm B was 2.1 months and not reached, respectively. Conclusions: Concurrent ipilimumab 10 mg/kg with SRS is safe. The WBRT arm was closed early because of slow accrual but demonstrated safety with ipilimumab 3 mg/kg. No patient experienced dose-limiting toxicity. Larger studies, including those with combination checkpoint inhibitor therapy and SRS, are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-207-00: CT Lung Cancer Screening and the Medical Physicist: Moving Forward

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-01: Background and Clinical Implementation of a Screening Program

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-02: Capturing Data Elements and the Role of Imaging Informatics

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-03: CT Protocols for Screening and the ACR Designated Lung Screening Program

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

aosflow3 (a1)

The aerosol observing system (AOS) is the primary platform for in situ aerosol measurements at Earth’s surface. Each AOS has a different complement of instruments, which are selected to ensure the best measurements at each deployment site. The AOS measures aerosol optical properties to better understand how particles interact with solar radiation and influence the Earth's radiation balance. These measurements are useful for calculating parameters used in radiative forcing calculations, such as the aerosol single scattering albedo, asymmetry parameter, mass scattering efficiency, and hygroscopic growth. Measurements made with the AOS form a long-term record at the ARM fixed sites. Shorter measurement records are available from mobile deployments in a wide variety of geographical regions. These measurements are valuable for: identifying long-term changes in aerosol properties identifying atmospheric processes controlling aerosol life cycle and their influence on clouds providing experimental data for developing and testing atmospheric climate models.

54 ENVIRONMENTAL SCIENCES↗

aoshumidgr (01)

The aerosol observing system (AOS) is the primary platform for in situ aerosol measurements at Earth’s surface. Each AOS has a different complement of instruments, which are selected to ensure the best measurements at each deployment site. The AOS measures aerosol optical properties to better understand how particles interact with solar radiation and influence the Earth's radiation balance. These measurements are useful for calculating parameters used in radiative forcing calculations, such as the aerosol single scattering albedo, asymmetry parameter, mass scattering efficiency, and hygroscopic growth. Measurements made with the AOS form a long-term record at the ARM fixed sites. Shorter measurement records are available from mobile deployments in a wide variety of geographical regions. These measurements are valuable for: identifying long-term changes in aerosol properties identifying atmospheric processes controlling aerosol life cycle and their influence on clouds providing experimental data for developing and testing atmospheric climate models.

54 ENVIRONMENTAL SCIENCES↗

aosimpactor (a1)

The aerosol observing system (AOS) is the primary platform for in situ aerosol measurements at Earth’s surface. Each AOS has a different complement of instruments, which are selected to ensure the best measurements at each deployment site. The AOS measures aerosol optical properties to better understand how particles interact with solar radiation and influence the Earth's radiation balance. These measurements are useful for calculating parameters used in radiative forcing calculations, such as the aerosol single scattering albedo, asymmetry parameter, mass scattering efficiency, and hygroscopic growth. Measurements made with the AOS form a long-term record at the ARM fixed sites. Shorter measurement records are available from mobile deployments in a wide variety of geographical regions. These measurements are valuable for: identifying long-term changes in aerosol properties identifying atmospheric processes controlling aerosol life cycle and their influence on clouds providing experimental data for developing and testing atmospheric climate models.

54 ENVIRONMENTAL SCIENCES↗

aosimpactor (b1)

The aerosol observing system (AOS) is the primary platform for in situ aerosol measurements at Earth’s surface. Each AOS has a different complement of instruments, which are selected to ensure the best measurements at each deployment site. The AOS measures aerosol optical properties to better understand how particles interact with solar radiation and influence the Earth's radiation balance. These measurements are useful for calculating parameters used in radiative forcing calculations, such as the aerosol single scattering albedo, asymmetry parameter, mass scattering efficiency, and hygroscopic growth. Measurements made with the AOS form a long-term record at the ARM fixed sites. Shorter measurement records are available from mobile deployments in a wide variety of geographical regions. These measurements are valuable for: identifying long-term changes in aerosol properties identifying atmospheric processes controlling aerosol life cycle and their influence on clouds providing experimental data for developing and testing atmospheric climate models.

54 ENVIRONMENTAL SCIENCES↗

aosflow1 (a1)

The aerosol observing system (AOS) is the primary platform for in situ aerosol measurements at Earth’s surface. Each AOS has a different complement of instruments, which are selected to ensure the best measurements at each deployment site. The AOS measures aerosol optical properties to better understand how particles interact with solar radiation and influence the Earth's radiation balance. These measurements are useful for calculating parameters used in radiative forcing calculations, such as the aerosol single scattering albedo, asymmetry parameter, mass scattering efficiency, and hygroscopic growth. Measurements made with the AOS form a long-term record at the ARM fixed sites. Shorter measurement records are available from mobile deployments in a wide variety of geographical regions. These measurements are valuable for: identifying long-term changes in aerosol properties identifying atmospheric processes controlling aerosol life cycle and their influence on clouds providing experimental data for developing and testing atmospheric climate models.

54 ENVIRONMENTAL SCIENCES↗

aosflow2 (a1)

The aerosol observing system (AOS) is the primary platform for in situ aerosol measurements at Earth’s surface. Each AOS has a different complement of instruments, which are selected to ensure the best measurements at each deployment site. The AOS measures aerosol optical properties to better understand how particles interact with solar radiation and influence the Earth's radiation balance. These measurements are useful for calculating parameters used in radiative forcing calculations, such as the aerosol single scattering albedo, asymmetry parameter, mass scattering efficiency, and hygroscopic growth. Measurements made with the AOS form a long-term record at the ARM fixed sites. Shorter measurement records are available from mobile deployments in a wide variety of geographical regions. These measurements are valuable for: identifying long-term changes in aerosol properties identifying atmospheric processes controlling aerosol life cycle and their influence on clouds providing experimental data for developing and testing atmospheric climate models.

54 ENVIRONMENTAL SCIENCES↗

Dynamics, control and sensor issues pertinent to robotic hands for the EVA retriever system

Basic dynamics, sensor, control, and related artificial intelligence issues pertinent to smart robotic hands for the Extra Vehicular Activity (EVA) Retriever system are summarized and discussed. These smart hands are to be used as end effectors on arms attached to manned maneuvering units (MMU). The Retriever robotic systems comprised of MMU, arm and smart hands, are being developed to aid crewmen in the performance of routine EVA tasks including tool and object retrieval. The ultimate goal is to enhance the effectiveness of EVA crewmen.

Mclauchlan, Robert A.↗

Performance Benefits Associated with Context-Dependent Arm Pointing Adaptation

Our previous work has demonstrated that head orientation can be used as a contextual cue to switch between mUltiple adaptive states. Subjects were assigned to one of three groups: the head orientation group tilted the head towards the right shoulder when drawing under a 0.5 gain of display and towards the left shoulder when drawing under a 1.5 gain of display; the target orientation group had the home & target positions rotated counterclockwise when drawing under the 0.5 gain and clockwise for the l.5 gain; the arm posture group changed the elbow angle of the arm they were not drawing with from full flexion to full extension with 0.5 and l.5 gain display changes. The head orientation cue was effectively associated with the multiple gains, in comparison to the control conditions. The purpose of the current investigation was to determine whether this context-dependent adaptation results in any savings in terms of performance measures such as movement duration and movement smoothness when subjects switch between multiple adaptive states. Subjects in the head adaptation group demonstrated reduced movement duration and increased movement smoothness (measured via normalized j erk scores) in comparison to the two control groups when switching between the 0.5 and 1.5 gain. of display. This work has demonstrated not only that subjects can acquire context-dependent adaptation, but also that it results in a significant savings of performance upon transfer between adaptive states

Seidler, R. D.↗

The potential of high-frequency forced pulsed water jet for nuclear decommissioning - 15367

Forced Pulse Water Jetting (FPWJ) has been demonstrated in other works as a credible and consistent method for removing coatings or otherwise preparing surfaces across numerous industries. Its applicability to the nuclear industry as a powerful tool for decommissioning and waste treatment has only recently being recognized and underpinning study is required before any deployment can be considered. Use of FPWJ within the nuclear sector for decommissioning and waste treatment, requires a different degree of surface finish to achieve a decontamination effect or an assured performance. This necessitates a greater erosion of the base metal than in other industries. The addition of a Forced Pulse Modulation Unit (FPMU) to a high pressure water jetting system offers performance shifts akin to the differences between High Pressure (HP) and Ultra High Pressure (UHP) water jets. Trials have been undertaken in a controlled environment to establish the number of cycles to achieve a given mass loss and or depth of penetration that would otherwise provide decontamination of mostly flat or simple geometry surfaces using a robotic arm for consistency and safety. It has also been shown that metalwork can be readily penetrated without risk of explosion, for example to allow draining of a gas cylinder. Most nuclear facilities have a plethora of pipe systems spanning various diameters. A considerable portion of the UK Sellafield site has 2 inch bore pipe. The FPMU technology is being adapted to consider applications in enclosed systems, such as decontamination of pipes. Exploratory works to date show there to be many physical attributes that influence performance that include, standoff of the jet, established propagated forced pulse jet length, interference from resultant water spray and angle of attack. Comparatively small changes to these parameters can have a profound effect on performance. The process is capable of removing 10's microns to several mms of metal progressively and repeatedly. This enables a credible potential treatment of plant and equipment at Intermediate Level Waste and High Level Waste thresholds. In considering this as a treatment method, a balance between performance, cost and environmental impact of effluents must be made and will be studied further during future active trials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A VO-seeded Approach for the Growth of Star-shaped VO2 and V2O5 Nanocrystals: Facile Synthesis Structural Characterization and Elucidation of Electronic Structure

Obtaining shape and size control of strongly correlated materials is imperative to obtain a fundamental understanding of the influence of finite size and surface restructuring on electronic instabilities in the proximity of the Fermi level. We present here a novel synthetic approach that takes advantage of the intrinsic octahedral symmetry of rock-salt-structured VO to facilitate the growth of six-armed nanocrystallites of related, technologically important binary vanadium oxides VO2 and V2O5. The prepared nanostructures exhibit clear six-fold symmetry and most notably show remarkable retention of electronic structure. The latter has been evidenced through extensive X-ray absorption spectroscopy measurements.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A design procedure for active control of beam vibrations

The transverse vibrations of beams is discussed and a methodology for the design of an active damping device is given. The Bernoulli-Euler equation is used to derive a transcendental transfer function, which relates a torque applied at one end of the beam to the rotational position and velocity at that point. The active damping device consists of a wire, a linear actuator and a short torque arm attached to one end of the beam. The action of the actuator varies a tension in the wire and creates a torque which opposes the rotation of the beam and thus damps vibration. A design procedure for such an active damper is given. This procedure shows the relationships and trade-offs between the actuator stroke, power required, stress levels in the wire and beam and the geometry of the beam and wire. It is shown that by consideration of the frequency response at the beam natural frequencies, the aforementioned relationships can be greatly simplified. Similarly, a simple way of estimating the effective damping ratios and eigenvalue locations of actively controlled beams is presented.

Dickerson, S. L.↗