Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Window Materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Carbon-Ion Pencil Beam Scanning Treatment With Gated Markerless Tumor Tracking: An Analysis of Positional Accuracy

Purpose: Having implemented amplitude-based respiratory gating for scanned carbon-ion beam therapy, we sought to evaluate its effect on positional accuracy and throughput. Methods and Materials: A total of 10 patients with tumors of the lung and liver participated in the first clinical trials at our center. Treatment planning was conducted with 4-dimensional computed tomography (4DCT) under free-breathing conditions. The planning target volume (PTV) was calculated by adding a 2- to 3-mm setup margin outside the clinical target volume (CTV) within the gating window. The treatment beam was on when the CTV was within the PTV. Tumor position was detected in real time with a markerless tumor tracking system using paired x-ray fluoroscopic imaging units. Results: The patient setup error (mean ± SD) was 1.1 ± 1.2 mm/0.6 ± 0.4°. The mean internal gating accuracy (95% confidence interval [CI]) was 0.5 mm. If external gating had been applied to this treatment, the mean gating accuracy (95% CI) would have been 4.1 mm. The fluoroscopic radiation doses (mean ± SD) were 23.7 ± 21.8 mGy per beam and less than 487.5 mGy total throughout the treatment course. The setup, preparation, and irradiation times (mean ± SD) were 8.9 ± 8.2 min, 9.5 ± 4.6 min, and 4.0 ± 2.4 min, respectively. The treatment room occupation time was 36.7 ± 67.5 min. Conclusions: Internal gating had a much higher accuracy than external gating. By the addition of a setup margin of 2 to 3 mm, internal gating positional error was less than 2.2 mm at 95% CI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effects of surface roughness on specular diagnostics in shocked experiments

Many shock experiments, whether impact, laser, or magnetically driven, use reflected optical light from shocked samples to diagnose their material properties. Specifically, optical velocimetry diagnostics, which do not require absolute power measurements, are regularly used to obtain equation-of-state information of materials. However, new diagnostics will be necessary to expand the realm of measured material properties, and many useful diagnostic techniques do require absolute measurements. Thus, it is important to understand what happens at the reflective surface of shock experiments, and the effect scattering has on the light collection of optical probes. To this end, we present results from experiments done to observe the behavior of a reflected beam from a specular coating on an optical window during shock impact. We find that the specular condition of the coating is adversely affected by the shock front, but this can be mitigated by minimizing roughness on the surface preceding the coating.

47 OTHER INSTRUMENTATION↗

Substrate temperature influence on the properties of GaN thin films grown by hollow-cathode plasma-assisted atomic layer deposition

Gallium nitride films were grown by hollow cathode plasma-assisted atomic layer deposition using triethylgallium and N{sub 2}/H{sub 2} plasma. An optimized recipe for GaN film was developed, and the effect of substrate temperature was studied in both self-limiting growth window and thermal decomposition-limited growth region. With increased substrate temperature, film crystallinity improved, and the optical band edge decreased from 3.60 to 3.52 eV. The refractive index and reflectivity in Reststrahlen band increased with the substrate temperature. Compressive strain is observed for both samples, and the surface roughness is observed to increase with the substrate temperature. Despite these temperature dependent material properties, the chemical composition, E{sub 1}(TO), phonon position, and crystalline phases present in the GaN film were relatively independent from growth temperature.

42 ENGINEERING↗

Electrolyte-Assisted Hydrogen Cycling in Lithium and Sodium Alanates at Low Pressures and Temperatures

An investigation of electrolyte-assisted hydrogen storage reactions in complex aluminum hydrides (LiAlH4 and NaAlH4) reveals significantly reduced reaction times for hydrogen desorption and uptake in the presence of an electrolyte. LiAlH4 evolves ~7.8 wt% H2 over ~3 h in the presence of a Li-KBH4 eutectic at 130 °C compared to ~25 h for the same material without the electrolyte. Similarly, NaAlH4 exhibits 4.8 wt% H2 evolution over ~4 h in the presence of a diglyme electrolyte at 150 °C compared to 4.4 wt% in ~15 h for the same material without the electrolyte. These reduced reaction times are composed of two effects, an increase in reaction rates and a change in the reaction kinetics. While typical solid state dehydrogenation reactions exhibit kinetics with rates that continuously decrease with the extent of reaction, we find that the addition of an electrolyte results in rates that are relatively constant over the full desorption window. Fitting the kinetics to an Avrami-Erofe’ev model supports these observations. The desorption rate coefficients increase in the presence of an electrolyte, suggesting an increase in the velocities of the reactant-product interfaces. In addition, including an electrolyte increases the growth parameters, primarily for the second desorption steps, resulting in the observed relatively constant reaction rates. Similar effects occur upon hydrogen uptake in NaH/Al where the presence of an electrolyte enables hydrogenation under more practical low temperature (75 °C) and pressure (50 bar H2) conditions.

25 ENERGY STORAGE↗

The mechanism driving a solid–solid phase transition in a biomacromolecular crystal

A solid-solid phase transition (SSPT) occurs between distinguishable crystalline forms. Because of its importance in application and theory in material science and condensed matter physics, SSPT has been studied most extensively in metallic alloys, inorganic salt or small organic molecular crystals, but much less so in biomacromolecular crystals. In general, the mechanism of SSPT at atomic and molecular levels is not well understood. Here, we describe the ordered molecular rearrangements in biomacromolecular crystals of the adenine riboswitch (riboA) aptamer using real-time serial crystallography and solution atomic force microscopy (AFM). The large, ligand-induced conformational changes drive the initial phase transition from the apo unit cell (AUC) to the trans unit cell 1 (TUC1). During this transition, coaxial stacking of P1 duplexes becomes the dominant packing interface, whereas P2-P2 interactions are almost completely disrupted, resulting in “floating” layers of molecules. The coupling points in TUC1 and their local conformational flexibility allow the molecules to reorganize to achieve the more densely packed and energetically favorable bound unit cell (BUC). Our study thus reveals the interplay between the conformational changes and the crystal phases—the underlying mechanism that drives the phase transition. Using polarized video microscopy (PVM) to monitor the SSPT in small crystals at high ligand concentration, we have identified the time window during which the major conformational changes take place, and simulated the in crystallo kinetics. Together, these results provide the spatiotemporal information necessary for informing time-resolved crystallography (TRX) experiments. Moreover, this study illustrates a practical approach to characterize SSPT in transparent crystals.

36 MATERIALS SCIENCE↗

Signatures of distinct impurity configurations in atomic-resolution valence electron-energy-loss spectroscopy: Application to graphene

The detection and identification of impurities and other point defects in materials is a challenging task. Signatures for point defects are typically obtained using spectroscopies without spatial resolution. Here in this paper, we demonstrate the power of valence electron-energy-loss spectroscopy (VEELS) in an aberration-corrected scanning transmission-electron microscope (STEM) to provide energy-resolved and atomically resolved maps of electronic excitations of individual impurities which, combined with theoretical simulations, yield unique signatures of distinct bonding configurations of impurities. We report VEELS maps for isolated Si impurities in graphene, which are known to exist in two distinct configurations. We also report simulations of the maps, based on density functional theory and dynamical scattering theory, which agree with and provide direct interpretation of observed features. We show that theoretical VEELS maps exhibit distinct and unambiguous signatures for the threefold- and fourfold-coordinated configurations of Si impurities in different energy-loss windows, corresponding to impurity-induced bound states, resonances, and antiresonances. With the advent of new monochromators and detectors with high energy resolution and low signal-to-noise ratio, the present work ushers an atomically resolved STEM-based spectroscopy of individual impurities as an alternative to conventional spectroscopies for probing impurities and defects.

36 MATERIALS SCIENCE↗

Vanadium and Niobium MXenes—Bilayered V 2 O 5 Asymmetric Supercapacitors

MXenes offer high metallic conductivity and redox capacitance that are attractive for high-power, high-energy storage devices. However, they operate limitedly under high anodic potentials due to irreversible oxidation. Pairing them with oxides to design asymmetric supercapacitors may expand the voltage window and increase the energy storage capabilities. Hydrated lithium preintercalated bilayered V 2 O 5 ( δ-Li x V 2 O 5 ·nH 2 O) is attractive for aqueous energy storage due to its high Li capacity at high potentials; however, its poor cyclability remains a challenge. To overcome its limitations and achieve a wide voltage window and excellent cyclability, it is combined with V 2 C and Nb 4 C 3 MXenes. Asymmetric supercapacitors employing lithium intercalated V 2 C (Li-V 2 C) or tetramethylammonium intercalated Nb 4 C 3 (TMA-Nb 4 C 3 ) MXenes as the negative electrode, and a δ-Li x V 2 O 5 ·nH 2 O composite with carbon nanotubes as the positive electrode in 5 m LiCl electrolyte operate over wide voltage windows of 2 and 1.6 V, respectively. The latter shows remarkably high cyclability—capacitance retention of ≈95% after 10 000 cycles. Here, this work highlights the importance of selecting appropriate MXenes to achieve a wide voltage window and a long cycle life in combination with oxide anodes to demonstrate the potential of MXenes beyond Ti 3 C 2 in energy storage.

36 MATERIALS SCIENCE↗

Effect of heat recirculation on the self-sustained catalytic combustion of propane/air mixtures in a quartz reactor

The self-sustained catalytic combustion of propane is experimentally studied in a two-pass, quartz heat-recirculation reactor (HRR) and compared to that in a no (heat) recirculation reactor (NRR). Structured monolithic reactors with Pt/{gamma}-Al{sub 2}O{sub 3}, LaMnO{sub 3}/{gamma}-Al{sub 2}O{sub 3}, and Pt doped perovskite catalysts have been compared in the HRR and NRR configurations. Heat recirculation enhances combustion stability, by widening the operating window of self-sustained operation, and changes the mode of stability loss from blowout to extinction. It is found that thermal shields (upstream and downstream of the monolith) play no role in the stability of a HRR but increase the stability of a NRR. The stability of a HRR follows this trend: Pt/{gamma}-Al{sub 2}O{sub 3} > doped perovskite > LaMnO{sub 3}/{gamma}-Al{sub 2}O{sub 3}. Finally, a higher cell density monolith enlarges the operating window of self-sustained combustion, and allows further increase of the power density of the process. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and experimental verification of an active noise cancellation (ANC) method for non-invasive sensing

Ultrasonic wave propagation may be used in non-invasive sensing to identify the properties of a fluid in a container. An ultrasonic excitation can be coupled into the liquid or the gas through the walls of the container and detected by a receiver on the other side. However, in addition to this fluid path, another signal will also propagate through the structure and is referred as noise in this study. For most materials, this structural noise will be of higher amplitude compared to the fluid signal due to the large acoustic impedance difference between the solid container and the fluid. In this paper, an active noise cancellation (ANC) method is developed and demonstrated on an experimental setup. It was shown that this method cancels more than 90% of the noise signal in a given time window of interest. A sequential version of this cancellation method is also proposed, and it was shown that its performance improves as the number of canceling excitations is increased. The performance was found to be independent of the location of canceling transducers and position of the silence window but dependent on the width of the silence window. As an example, the ANC method was applied to noise cancellation of a signal travelling through water in a stainless-steel container. The signal-to-noise ratio (SNR) of the water signal in the window of interest was increased by 148% from 13.98 dB to 34.68 dB by using the proposed ANC method.

42 ENGINEERING↗

Li-Substituted Layered-Spinel Cathode Material for Sodium-Ion Batteries

The O 3 -type layered Na(Ni x Fe y Mn z )O 2 (0 < x, y, z < 1) cathode materials have attracted great interest in sodium ion batteries due to the abundance and cost of raw materials and their high specific capacities. However, the cycling stability and rate capability at high voltages (> 4.0 V) of these materials remain an issue. In this work, we successfully synthesized a Li-substituted layered-tunneled (O 3 -spinel) intergrowth cathode (LS-NFM) to address these issues. The remarkable structural compatibility and connectivity of the two phases were confirmed by X-ray diffraction (XRD), selected area electron diffraction (SAED), and high-resolution transmission electron microscopy (HRTEM). The LS-NFM electrode reached a discharge capacity of 96 mAh g -1 with a capacity retention of 86% after 100 cycles at a current rate of 100 mA g -1 in a voltage window of 2.0-4.2 V. Moreover, the LS-NFM cathode exhibited an enhanced rate capability in comparison to the undoped single-phased layered cathode (NFM). The enhanced rate capability of LS-NFM can be explained by the significantly increased effective Na + diffusivity measured by the galvanostatic intermittent titration technique (GITT) compared to the undoped control NFM cathode, which can be ascribed to the improved charge transport kinetics through shortened diffusion path by direct connection between the 3D channels in the spinel phase and 2D channels in the layered phase. The results from ex situ hard/soft X-ray adsorption spectroscopy (XAS) suggest that the capacity of the LS-NFM cathode is mainly associated with the Ni 2+ /Ni 4+ redox couple and slightly from the Fe 3+ /Fe 4+ redox couple. The voltage profile of the LS-NFM cathode exhibits a reversible plateau above 4.0 V, indicating great stability at high voltages and structural stabilization by the spinel phase. In addition to the substitution of various transition metals, or the modification of the stoichiometry of each transition metal, this study provides a new strategy to improve electrochemical performance of layered cathode materials for sodium ion batteries.

25 ENERGY STORAGE↗

Toward Higher Voltage Solid-State Batteries by Metastability and Kinetic Stability Design

The energy density of battery systems is limited largely by the electrochemical window of the electrolyte. Here, the combined thermodynamic and kinetic effects of mechanically induced metastability are shown to greatly widen the operational voltage window of solid-state batteries based on ceramic-sulfide electrolytes. Solid electrolyte voltage stability up to 10 V is achieved with minimal degradation, far beyond the capability of organic liquid electrolytes. Furthermore, combined experiment, ab initio computation, and theoretical modeling identify the nature of mechanically constrained Li 10 GeP 2 S 12 decomposition both within the bulk and at interfaces with cathode materials at very high voltages. Previously unclear kinetic processes are identified that, when properly implemented, can potentially allow solid-state full cells with remarkably high operational voltages.

25 ENERGY STORAGE↗

Stabilizing and understanding the interface between nickel-rich cathode and PEO-based electrolyte by lithium niobium oxide coating for high-performance all-solid-state batteries

The pursuit of high energy density and safe lithium ion batteries (LIBs) is the urgent goal for the development of next-generation electric vehicles (EVs). All-solid-state batteries (ASSBs) with the combination of poly(ethylene oxide) (PEO)-based solid polymer electrolyte (SPE) and Ni-rich lithium nickel manganese cobalt oxide LiNi0.8Mn0.1Co0.1O2 (NMC811) cathode are promising candidates for EVs due to their improved energy density and safety. However, the low electrochemical oxidation window of PEO-based SPE and the instability of NMC811 at the charge/discharge process seriously restrict the battery performance. Herein, a high voltage stable solid-state electrolyte layer lithium niobium oxide (LNO) is coated on the NMC811 electrode surface by atomic layer deposition for stabilizing NMC811-PEO solid polymer batteries. Electrochemical tests show that LNO coating can stabilize the NMC811 active materials and mitigate the decomposition of SPE upon the cycling process, rendering a good performance of NMC811-PEO solid polymer battery. Mechanism studies by SEM, STEM, XAS, and XPS disclose that the uncoated NMC811 suffers from chemomechanical degradations along with oxygen release triggering the decomposition of SPE, which results in unstable cathodic electrolyte interphase. With LNO coating, chemomechanical degradations and oxygen release are inhibited and the decomposition of SPE is mitigated. This paper renders a stable and high-performance high-energy-density SSB for high voltage application, which paves the way toward next-generation solid-state LIBs.

25 ENERGY STORAGE↗

Multivariate Curve Resolution Analysis for Interpretation of Dynamic Cu K-Edge X-ray Absorption Spectroscopy Spectra for a Cu Doped V2O5 Lithium Battery

Vanadium pentoxide materials prepared through sol-gel processes act as excellent intercalation hosts for lithium as well as polyvalent cations. A chemometric approach has been applied to study the X-ray absorption near-edge structure (XANES) evolution during in situ scanning of the Cu{sub 0.1}V{sub 2}O{sub 5} xerogel/Li ions battery. Among the more common techniques, the fixed size windows evolving factor analysis (FSWEFA) permits the number of species involved in the experiment to be determined and the range of existence of each of them. This result, combined with the constraints of the invariance of the total concentration and non-negativity of both concentrations and spectra, enabled us to obtain the spectra of the pure components using a multivariate curve resolution refined by an alternate least squares fitting procedure. This allowed the normalized concentration profile to be understood. This data treatment evidenced the occurrence, for the first time, of three species during the battery charging. This fact finds confirmation by comparison of the pure spectra with the experimental ones. Extended X-ray absorption fine structure (EXAFS) analysis confirms the occurrence of three different chemical environments of Cu during battery charging.

25 ENERGY STORAGE↗

Open-source electrochemical cell for in situ X-ray absorption spectroscopy in transmission and fluorescence modes

X-ray spectroscopy is a valuable technique for the study of many materials systems. Characterizing reactions in situ and operando can reveal complex reaction kinetics, which is crucial to understanding active site composition and reaction mechanisms. In this project, the design, fabrication and testing of an open-source and easy-to-fabricate electrochemical cell for in situ electrochemistry compatible with X-ray absorption spectroscopy in both transmission and fluorescence modes are accomplished via windows with large opening angles on both the upstream and downstream sides of the cell. Using a hobbyist computer numerical control machine and free 3D CAD software, anyone can make a reliable electrochemical cell using this design. Onion-like carbon nanoparticles, with a 1:3 iron-to-cobalt ratio, were drop-coated onto carbon paper for testing in situ X-ray absorption spectroscopy. Cyclic voltammetry of the carbon paper showed the expected behavior, with no increased ohmic drop, even in sandwiched cells. Chronoamperometry was used to apply 0.4 V versus reversible hydrogen electrode, with and without 15 min of oxygen purging to ensure that the electrochemical cell does not provide any artefacts due to gas purging. The XANES and EXAFS spectra showed no differences with and without oxygen, as expected at 0.4 V, without any artefacts due to gas purging. The development of this open-source electrochemical cell design allows for improved collection of in situ X-ray absorption spectroscopy data and enables researchers to perform both transmission and fluorescence simultaneously. It additionally addresses key practical considerations including gas purging, reduced ionic resistance and leak prevention.

08 HYDROGEN↗

Simulation of solar cells with quantum wells and comparison with conventional solar cells

The efficiency of photoconversion in solar cells based on GaAs with InGaAs quantum wells under the AM 1.5 conditions for various levels of base doping has been simulated using the software package Sim-Windows. The results obtained are compared with the efficiency of photoconversion in conventional solar cells. It is shown that solar cells with quantum wells can exhibit a fairly high efficiency of photoconversion in comparison with the photoconversion efficiency of conventional solar cells under the following conditions: (i) the lifetimes of for charge carriers in the quantum wells are longer than those in the barrier material and (ii) the level of doping of the base is not very high. It is established that the maximum efficiency of photoconversion in conventional solar cells is higher than the photoconversion efficiency in solar cells with quantum wells. This efficiency is attained at high doping levels in the base ({approx}3 x 10{sup 18} cm{sup -3} at the parameters used in calculations). This is related to a more intense radiative recombination and also to specific features of screening and charge transport in solar cells with quantum wells at high doping levels. It is shown that, at fairly large values for the degree of concentration of incident radiation, the values for the photoconversion efficiency in solar cells with quantum wells for the low and high levels of doping of the base come closer to each other.

36 MATERIALS SCIENCE↗

Search for heavy Majorana neutrinos in pp collisions at √s = 8 TeV with the CMS detector & photodetector and calorimeter R&D for particle colliders

This thesis contains both physics analysis and hardware studies. It consists of two primary sections: the results of a search for heavy Majorana mass neutrinos, using the event signature of same (like) sign charged electron pairs ($e^{\pm} e^{\pm}$ ) and two jets, and the results of studies to upgrade the Hadronic Forward (HF) and Hadronic Endcap (HE) subdetectors in the Compact Muon Solenoid (CMS) detector in response to the high intensity proton-proton collisions generated at the Large Hadron Collider (LHC) at European Organization for Nuclear Research (CERN, Conseil Europ\'{e}en pour la Recherche Nucl\'{e}aire). In this search for Majorana mass neutrinos, same sign dielectron ($e^{\pm} e^{\pm}$) + dijet events in the final state have been considered as a signature for neutrino particles. The analyzed data corresponds to an integrated luminosity of 19.7 fb\textsuperscript{-1} of proton-proton collisions at a center of mass energy of $\sqrt{s} = 8 \text{TeV}$, collected using the CMS detector during the 2012 operation at the LHC. Monte Carlo simulations accounting for the theoretical expectations of the Standard Model (SM) and the detector limitations are used to prototype the experiment and to test proposed analysis steps. No excess of events is observed in the data beyond the expected SM background. Upper limits are set on the mixing element squared, $|{V}_{eN}|^{2}$, of the heavy Majorana neutrino with standard model neutrinos, as a function of Majorana neutrino mass for masses in the range of 40-500 $GeV/c^2$. The detector upgrade search comprises three sections of this thesis. The first section describes the test results of 1785 multianode Hamamatsu R7600U-200-M4 photomultiplier tubes (PMT) in numerous parameters such as gain, dark current, and timing characteristics, which provide insights on the expected performance of the upgraded CMS-HF detector. These PMTs replaced the previous single anode R7525 PMTs because the glass windows of previous PMTs are the source of Cherenkov radiation, which causes a background noise in the experiment. The second section reports characterization results of two types of PMTs in a novel operation mode for Secondary Emission (SE) Ionization Calorimetry, which is a novel technique to measure electromagnetic shower particles in extreme radiation environments. The third section presents the test results of novel scintillating materials for CMS experiment in specific and future particle accelerators in general. These materials are Polyethylene Naphthalate (PEN), Polyethylene Terephthalate (PET), high efficiency mirror (HEM) and quartz plates with various organic and inorganic coating materials such as p-Terphenyl (pTp), Anthracene and Gallium-doped Zinc Oxide (ZnO:Ga). We have investigated them for radiation hardness, light yield, timing characteristics, and scintillation and transmission properties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hanford Site Annual Report Radiological Dose Calculation Upgrade Evaluation

Operations at the Hanford Site, Richland, Washington, result in the release of radioactive materials to offsite residents. Site authorities are required to estimate the dose to the maximally exposed offsite resident. Due to the very low levels of exposure at the residence, computer models, rather than environmental samples, are used to estimate exposure, intake, and dose. A DOS-based model has been used in the past (GENII version 1.485). GENII v1.485 has been updated to a Windows®-based software (GENII version 2.08). Use of the updated software will facilitate future dose evaluations, but must be demonstrated to provide results comparable to those of GENII v1.485. This report describes the GENII v1.485 and GENII v2.08 dose exposure, intake, and dose estimates for the maximally exposed offsite resident reported for calendar year 2008. The GENII v2.08 results reflect updates to implemented algorithms. No two environmental models produce the same results, as was again demonstrated in this report. The aggregated dose results from 2008 Hanford Site airborne and surface water exposure scenarios provide comparable dose results. Therefore, the GENII v2.08 software is recommended for future offsite resident dose evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Insights Into the Mineralogy and Surface Chemistry of Extracellular Biogenic S 0 Globules Produced by Chlorobaculum tepidum

Elemental sulfur (S 0 ) is produced and degraded by phylogenetically diverse groups of microorganisms. For Chlorobaculum tepidum , an anoxygenic phototroph, sulfide is oxidized to produce extracellular S 0 globules, which can be further oxidized to sulfate. While some sulfur-oxidizing bacteria (e.g., Allochromatium vinosum ) are also capable of growth on commercial S 0 as an electron donor, C. tepidum is not. Even colloidal sulfur sols, which appear indistinguishable from biogenic globules, do not support the growth of C. tepidum . Here, we investigate the properties that make biogenic S 0 globules distinct from abiotic forms of S 0 . We found that S 0 globules produced by C. tepidum and abiotic S 0 sols are quite similar in terms of mineralogy and material properties, but the two are distinguished primarily by the properties of their surfaces. C. tepidum ’s globules are enveloped by a layer of organics (protein and polysaccharides), which results in a surface that is fundamentally different from that of abiotic S 0 sols. The organic coating on the globules appears to slow the aging and crystallization of amorphous sulfur, perhaps providing an extended window of time for microbes in the environment to access the more labile forms of sulfur as needed. Overall, our results suggest that the surface of biogenic S 0 globules may be key to cell–sulfur interactions and the reactivity of biogenic S 0 in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗