Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLTAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Production of magnetized electron beam from a DC high voltage photogun

Bunched-beam electron cooling is a key feature of all proposed designs of the future electron-ion collider, and a requirement for achieving the highest promised collision luminosity. At the Jefferson Lab Electron Ion Collider (JLEIC), fast cooling of ion beams will be accomplished via so-called 'magnetized cooling' implemented using a recirculator ring that employs an energy recovery linac. In this contribution, we describe the production of magnetized electron beam using a compact 300 kV DC high voltage photogun with an inverted insulator geometry, and using alkali-antimonide photocathodes. Beam magnetization was assessed using a modest diagnostic beamline that includes YAG view screens used to measure the rotation of the electron beamlet passing through a narrow upstream aperture. Magnetization results are presented for different gun bias voltages and for different laser spot sizes at the photocathode, using 532 nm lasers with DC and RF time structure. Photocathode lifetime was measured at currents up to 4.5 mA, with and without beam magnetization.

Al Mamun, Md Abdullah↗

300 kV DC High Voltage Photogun with Inverted Insulator Geometry and CsK2sb Photocathode

A compact DC high voltage photogun with inverted-insulator geometry was designed, built and operated reliably at 300 kV bias voltage using alkali-antimonide photocathodes. This presentation describes key electrostatic design features of the photogun with accompanying emittance measurements obtained across the entire photocathode surface that speak to field non-uniformity within the cathode/anode gap. A summary of initial photocathode lifetime measurements at beam currents up to 4.5 mA is also presented.

Wang, Yan↗

High Dynamic Voltage Range Studies of Piezoelectric Multilayer Actuators at Low Temperatures

Piezo actuators are used for resonance control in superconducting linacs. In high accelerating gradients linacs, such as those operated in a pulsed mode, the piezos require a large operating voltage. This is due to the Lorentz forced detuning which causes a large frequency shift and is compensated with an active piezo-tuning system. In this high dynamic voltage range the piezo is expected to warm up drastically due to it being in an insulated vacuum. This study characterizes the dielectric properties (capacitance, dielectric losses), the piezo stroke (from geophone), and thermal properties such as heating. Results obtained in the temperature range of 20K to 300K will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Commercialization of Medium Voltage HTS Triax™ Cable Systems

The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax™ cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax™ cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS Triax™ design, so it provided an economical tool for these of the project tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recovery Act: Strategies for Voltage Control and Transient Stability Assessment

As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation differs from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs.

17 WIND ENERGY↗

The Commercial Development of Water Repellent Coatings for High Voltage Transmission Lines

The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy's Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

Hunter, Scott Robert↗

The commercial development of water repellent coatings for high voltage transmission lines

The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy's Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submerged Medium Voltage Cable Systems at Nuclear Power Plants: A Review of Research Efforts Relevant to Aging Mechanisms and Condition Monitoring

In a submerged environment, power cables may experience accelerated insulation degradation due to water-related aging mechanisms. Direct contact with water or moisture intrusion in the cable insulation system has been identified in the literature as a significant aging stressor that can affect performance and lifetime of electric cables. Progressive reduction of the dielectric strength is commonly a result of water treeing which involves the development of permanent hydrophilic structures in the insulation coinciding with the absorption of water into the cable. Water treeing is a phenomenon in which dendritic microvoids are formed in electric cable insulation due to electrochemical reactions, electromechanical forces, and diffusion of contaminants over time. These reactions are caused by the combined effects of water presence and high electrical stresses in the material. Water tree growth follows a tree-like branching pattern, increasing in volume and length over time. Although these cables can be “dried out,” water tree degradation, specifically the growth of hydrophilic regions, is believed to be permanent and typically worsens over time. Based on established research, water treeing or water induced damage can occur in a variety of electric cables including XLPE, TR-XLPE and other insulating materials, such as EPR and butyl rubber. Once water trees or water induced damage form, the dielectric strength of an insulation material will decrease gradually with time as the water trees grow in length, which could eventually result in failure of the insulating material. Under wet conditions or in submerged environments, several environmental and operational parameters can influence water tree initiation and affect water tree growth. These parameters include voltage cycling, field frequency, temperature, ion concentration and chemistry, type of insulation material, and the characteristics of its defects. In this effort, a review of academic and industrial literature was performed to identify: 1) findings regarding the degradation mechanisms of submerged cabling and 2) condition monitoring methods that may prove useful in predicting the remaining lifetime of submerged medium voltage power cables. The research was conducted by a multi-disciplinary team, and sources included official NRC reports, national laboratory reports, IEEE standards, conference and journal proceedings, magazine articles, PhD dissertations, and discussions with experts. The purpose of this work was to establish the current state-of-the-art in material degradation modeling and cable condition monitoring techniques and to identify research gaps. Subsequently, future areas of focus are recommended to address these research gaps and thus strengthen the efficacy of the NRC’s developing cable condition monitoring program. Results of this literature review and details of the testing recommendations are presented in this report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Voltage LED Light Engine with Integrated Driver

LED luminaires have seen dramatic changes in cost breakdown over the past few years. The LED component cost, which until recently was the dominant portion of luminaire cost, has fallen to a level of the same order as the other luminaire components, such as the driver, housing, optics etc. With the current state of the technology, further luminaire performance improvement and cost reduction is realized most effectively by optimization of the whole system, rather than a single component. This project focuses on improving the integration between LEDs and drivers. Lumileds has developed a light engine platform based on low-cost high-power LEDs and driver topologies optimized for integration with these LEDs on a single substrate. The integration of driver and LEDs enables an estimated luminaire cost reduction of about 25% for targeted applications, mostly due to significant reductions in driver and housing cost. The high-power LEDs are based on Lumileds’ patterned sapphire substrate flip-chip (PSS-FC) technology, affording reduced die fabrication and packaging cost compared to existing technology. Two general versions of PSS-FC die were developed in order to create the desired voltage and flux increments for driver integration: (i) small single-junction die (0.5 mm 2 ), optimal for distributed lighting applications, and (ii) larger multi-junction die (2 mm 2 and 4 mm 2 ) for high-power directional applications. Two driver topologies were developed: a tapped linear driver topology and a single-stage switch-mode topology, taking advantage of the flexible voltage configurations of the new PSS-FC die and the simplification opportunities enabled by integration of LEDs and driver on the same board. A prototype light engine was developed for an outdoor “core module” application based on the multi-junction PSS-FC die and the single-stage switch-mode driver. The light engine meets the project efficacy target of 128 lm/W at a luminous flux greater than 4100 lm, a correlated color temperature (CCT) of 4000K and a color rendering index (CRI) greater than 70.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Daikin Advanced Lithium Ion Battery Technology – High Voltage Electrolyte - REVISED

An evaluation of high voltage electrolytes which contain fluorochemicals as solvents/additive has been completed with the objective of formulating a safe, stable electrolyte capable of operation to 4.6 V. Stable cycle performance has been demonstrated in LiNi1/3Mn1/3Co1/3O2 (NMC111)/graphite cells to 4.5 V. The ability to operate at high voltage results in significant energy density gain (>30%) which would manifest as longer battery life resulting in higher range for electric vehicles. Alternatively, a higher energy density battery can be made smaller without sacrificing existing energy. In addition, the fluorinated electrolytes examined showed better safety performance when tested in abuse conditions. The results are promising for future advanced battery development for vehicles as well as other applications.

25 ENERGY STORAGE↗

Studies on the Effects of High Renewable Penetrations on Driving Point Impedance and Voltage Regulator Performance: National Renewable Energy Laboratory/Sacramento Municipal Utility District Load Tap Changer Driving Point Impedance Project

Voltage regulators perform as desired when regulating from the source to the load and when regulating from a strong source (utility) to a weak source (distributed generation). (See the glossary for definitions of a strong source and weak source.) Even when the control is provisioned for reverse operation, it has been observed that tap-changing voltage regulators do not perform as desired in reverse when attempting regulation from the weak source to the strong source. The region of performance that is not as well understood is the regulation between sources that are approaching equal strength. As part of this study, we explored all three scenarios: regulator control from a strong source to a weak source (classic case), control from a weak source to a strong source (during reverse power flow), and control between equivalent sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diffusion Through Single And Double Layer Shields And Induced Voltages From Low Frequency Electromagnetic Environments

The diffusion through shells consisting of either a single conducting or double conducting layers are examined. Exterior drives resulting from Electromagnetic Radiation (EMR), Electromagnetic Pulse (EMP), nearby (indirect) lightning, and DC (low frequency) magnetic fields are used. Both the interior field and the induced voltage from a maximally oriented and sized single turn loop are estimated. It is shown that the loop voltage with the empty cavity bounds the case where the center region is excluded by a conducting object. The cases of interior magnetic and electric fields from an exterior magnetic drive and the interior electric field from an exterior electric drive are both solved; the magnetic interior field from an exterior magnetic drive is the only case that results in a nonzero low frequency penetration.

42 ENGINEERING↗

Minimize the Voltage Degradation in Li-rich Layered Oxide Cathode Materials by Morphology Control

Li-rich layered oxides, either as a solid solution or as a nano-composite of layered Li 2 MnO 3 and Li(TM)O 2 (TM=Ni, Co, Mn), draw significant attention as the next-generation cathode materials for high-energy-density lithium ion batteries in electric vehicles. Over the past twenty years, the discharge capacity at room temperature of these cathode materials has been improved from 200 mAh g -1 to over 320 mAh g -1 today, even higher at elevated temperatures. While the research has continued to push the limit of the available capacity of the materials throughout the years, there are many issues still unclear. And numerous scientific challenges, especially voltage degradation during cycling of these materials, that must be overcome to realize their utilization in commercial lithium ion batteries. Here, we report a design of modified co-precipitation method without ammonia addition to synthesize morphology controlled Li-rich material Li 1.2 Ni 0.2 Mn 0.6 O 2 as high energy density cathode for lithium ion batteries. The obtained material has spherical secondary particles with uniform dispersion. The secondary particles are dense, and have an average diameter of approximately 3 μm. These secondary spherical particles consist of primary particles with particle size approximately 150 nm. The morphology controlled sample can minimize voltage decay as well as improve capacity retention during cycling. And furthermore, the influence of morphology control on the cycling performance has been investigated through Transmission X-ray Microscope.

Zhang, Minghao↗

Integration of Ultrawide Bandgap Photoconducting Semiconductor Switches into High-Voltage, High-Current Pulser Systems

In this feasibility study we will evaluate the viability of integrating ultrawide bandgap (UWBG) photoconducting semiconductor switches (PCSS) in high-voltage pulser systems capable of driving low-impedance dynamic loads critical for next-generation accelerator and RF-source applications. The project consisted of developing modelling tools that would inform design of UWBG PCSS packages that could be mounted onto conventional circuit boards. Specifically, we are interested in evaluating the following through simulation software: (1) resistance to electrical breakdown (2) proximity effects due to high-frequency skin effect (3) transient behavior from switching (4) effective transmission of RF signals (5) thermal dynamics of the switch under operation (6) sensitivity to inhomogeneities in optical excitation of the material (7) cross-talk effects from parallel switching structures, and (8) susceptibility of system to damaged components. The project resulted in the development of a special-purpose circuit code that implements photoconductivity physics. This code was used to evaluate objectives 1-6 above, identifying a critical requirement associated with the need for fine control of dopant concentrations in the UWBG material to reach an optimal solution for voltage standoff and laser light responsivity requirements. In addition, we identified that the temperature dependence of the electrical conductivity of this material was typically not well-measured and developed a platform for measuring both the “dark” and “illuminated” conductivity on real physical switches in the lab to better inform our models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inorganic voltage nanosensors for bioelectricity studies in bacterial communities

We developed both membrane potential nanosensors (MPNs) and voltage sensing dyes (VSDs), and quantitative optical measurement tools to measure membrane potential (MP) at the level of a single bacterial cell, with voltage resolution of ~10 mV changes. Our approach relied on (i) novel MPNs and novel VSDs that measures MPs via fluorescence lifetime; (ii) a quantitative approach to fluorescence lifetime imaging microscopy (FLIM) data based on a novel time-resolved camera and phasor analysis. We demonstrate MP measurements over time for single bacterial cells.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrafast High Voltage Kicker System Hardware for Ion Clearing Gaps

Jefferson Lab (JLab) will collaborate with Radiabeam, LLC in a DOE SBIR Phase II Project (DOE Grant No. DE-SC0019684, title: “Ultrafast High Voltage Kicker System Hardware for Ion Clearing Gaps”) to develop and test a MHz high voltage nanosecond kicker system that enables the time structure required by the ion traps for high current electron beam cooling. High current (in particular energy recovery) linac based electron cooling facilities for medium to high energy bunched proton or ion beams are of great interest for the recently funded Electron-Ion Collider (EIC) to which Jefferson Lab plays a critical role. The successful execution of this project will enable the capability to mitigate the ion trapping effect and circumvent a major obstacle preventing reliable operation of the crucial cooling facilities.

43 PARTICLE ACCELERATORS↗

20-kV GaN Switch Technology Demonstrated in High-Efficiency Medium-Voltage Power Module

GaN holds significant potential as a material for vertical p-n diodes, enabling the realization of devices with reverse breakdown voltages of 5 kV or higher. Carbon serves as the primary compensating dopant in the growth process, incorporated into GaN during metalorganic chemical vapor deposition (MOCVD) growth. The level of carbon incorporation depends on several factors, including growth rate, ammonia flow, temperature, pressure, and trimethylgallium (TMGa) flow. Through guided empirical modeling, the carbon incorporation in GaN growth could be predicted using a single parameter based on the ratio of ammonia flow to the growth rate. This model accurately predicts carbon concentrations ranging from 1x10 17 to 5x10 14 cm -3 while maximizing growth rates. Other extrinsic dopants have either been reduced below the threshold of consideration or modeled using similar single-parameter relationships. By identifying the dominant extrinsic dopants and accounting for them, an intrinsic defect with a concentration of 2.2x10 15 cm -3 was identified. By combining these relationships, growth conditions for n-GaN were optimized, resulting in electron concentrations as low as 1x10 15 cm -3 . Leveraging these techniques, p-n diodes were grown, achieving a reverse breakdown voltage as high as 3.1 kV.

36 MATERIALS SCIENCE↗

High Speed Medium Voltage CHP System with Advanced Grid Support

The project was a collaboration between Clemson University and TECO Westinghouse Motor Company. The goal of the project was to develop a medium voltage commercial grid-tied system with advanced grid support functions. Current state-of-the-art in medium voltage, multi-megawatt power electronic systems do not support advanced grid functions, traditionally due to power electronic limitations and required applications. The developed system is capable of interacting with the power system at the distribution level to efficiently integrate gas turbine generation systems or any other ac generation system with up to 20MWe of power production capacity. This project demonstrated a high level of technical readiness of the 1MW, 500Hz, 15000 RPM high frequency Combined Heat and Power (CHP) generator and electric machine system, utilizing advanced grid support functions required by IEEE Std. 1547-2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗