Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates
Eight-ply (0, + or - 45, 0)s laminates of Hercules AS/3501-6 graphite epoxy composite are fabricated using various cure pressures ranging from 0.52 to 0.86 MPa and cure temperatures ranging from 150 C to 200 C. In general, the minimum composite void volume fraction is obtained at a cure temperature of 175 C and a cure pressure of 0.86 MPa, or at 200 C and 0.86 MPa. The ultrasonic attenuation at 4 MHz was found to correlate with the composite void volume fraction. Composite specimens were tested in flexural fatigue. Beyond 10,000 fatigue cycles, the ultrasonic attenuation at 4 MHz was found to increase and the flexural stiffness was found to decrease. The ultrasonic attenuation at 4 MHz of the as-fabricated composite can be correlated with the number of fatigue cycles to failure.