Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Simultaneous measurements of velocity, temperature, and pressure using rapid CW wavelength-modulation laser-induced fluorescence of OH

In high speed flows, laser induced fluorescence (LIF) on Doppler shifted transitions is an attractive technique for velocity measurement. LIF velocimetry was applied to combined single-point measurements of velocity, temperature, and pressure and 2-D imaging of velocity and pressure. Prior to recent research using NO, LIF velocimetry in combustion related flows relied largely on the use of seed molecules. Simultaneous, single-point LIF measurements is reported of velocity, temperature, and pressure using the naturally occurring combustion species OH. This experiment is an extension of earlier research in which a modified ring dye laser was used to make time resolved temperature measurements behind reflected shock waves by using OH absorption an in postflame gases by using OH LIF. A pair of fused-silica rhombs mounted on a single galvanonmeter in an intracavity-doubled Spectra-Physics 380 ring laser permit the UV output to be swept continuously over a few wave numbers at an effective frequency of 3kHz.

Chang, A. Y.↗

Performance of the Aspect Camera Assembly for the Advanced X-Ray Astrophysics Facility: Imaging

The Aspect Camera Assembly (ACA) is a "state-of-the-art" star tracker that provides real-time attitude information to the Advanced X-Ray Astrophysics Facility - Imaging (AXAF-I), and provides imaging data for "post-facto" ground processing. The ACA consists of a telescope with a CCD focal plane, associated focal plane read-out electronics, and an on-board processor that processes the focal plane data to produce star image location reports. On-board star image locations are resolved to 0.8 arcsec, and post-facto algorithms yield 0.2 arcsec star location accuracies (at end of life). The protoflight ACA has been built, along with a high accuracy vacuum test facility. Image position determination has been verified to < 0.2 arcsec accuracies. This paper is a follow-on paper to one presented by the author at the AeroSense '95 conference. This paper presents the "as built" configuration, the tested performance, and the test facility's design and demonstrated accuracy. The ACA has been delivered in anticipation of a August, 1998 shuttle launch.

Michaels, Dan↗

Space-Time Quantum Information from the Entangled States of Magnetic Molecule (STI Product)

This collaborative project combines synthesis, measurement, and theory by three faculty members at the Eddleman Quantum Institute of UC Irvine to effectively investigate the quantum properties of molecules in the space, time, and frequency domains. Through synthetic chemistry, molecules are tailored for their magnetic and coherent properties. By combining femtosecond (fs) terahertz (THz) light and a continuous wave (cw) THz laser with a low temperature scanning tunneling microscope (STM), quantum phenomena are probed with simultaneous femtosecond temporal and atomic-scale spatial resolution. In particular, the invention of the quantum superposition microscope (QSM) advances quantum sensing for enhanced spectroscopy and imaging capabilities. Coupling theory to the experimental efforts offers a deeper understanding and predictive power for the molecular systems. The phenomena of superposition, entanglement, and coherence is central to quantum information science and can be realized in qubit states. Many systems can be modeled by a double-well potential in which two levels are formed in the two lowest energy states interacting with the environment and external radiation. In focusing on molecules as two-level systems, the underlying expectation is that their tunable composition and structure allows an effective parameter space to optimize their use as qubits for quantum sensing and computing. The THz radiation induces the superposition between the two states, appearing as temporal oscillations that damp in amplitude. Enhanced spectroscopy and imaging in the time and frequency domains is achieved through the extreme sensitivity of the frequency and damping of coherence of two-level systems to its environment. A single hydrogen molecule trapped in the STM tunneling gap experiences a double-well potential and absorption of THz femtosecond pulses of light creates the superposition of its two levels, appearing as damped oscillations in the light induced direct current (DC). The oscillation frequency depends sensitively on the electric field distribution of the copper nitride (Cu 2 N) surface, through the Stark effect, and associated with the different charge distributions at the copper and nitrogen sites and in between. This QSM can resolve variation in the surface electric field with 0.02 nanometer resolution. In addition, the single hydrogen molecule entaes with nearby hydrogen molecules as seen in the avoided level crossings of energy (oscillation frequency) versus the voltage across the tunneling gap. Thus, the first application of the QSM senses and images the surface electric field at the atomic scale. Results from this project advance fundamental understanding of quantum phenomena, develop novel synthesis, measurement, and theory, provide the knowledge foundation for molecule-based qubits and sensing that enable the development of the QSM and emergent technologies. This project trained researchers in quantum information science, extended knowledge in classrooms, and outreached to the community.

47 OTHER INSTRUMENTATION↗

A fast-time-response extreme ultraviolet spectrometer for measurement of impurity line emissions in the Experimental Advanced Superconducting Tokamak

A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 Å wavelength range with fast time response has been newly developed to measure line emissions from highly ionized tungsten in the Experimental Advanced Superconducting Tokamak (EAST) with a tungsten divertor, while the monitoring of light and medium impurities is also an aim in the present development. A flat-field focal plane for spectral image detection is made by a laminar-type varied-line-spacing concave holographic grating with an angle of incidence of 87°. A back-illuminated charge-coupled device (CCD) with a total size of 26.6 × 6.6 mm{sup 2} and pixel numbers of 1024 × 255 (26 × 26 μm{sup 2}/pixel) is used for recording the focal image of spectral lines. An excellent spectral resolution of Δλ{sub 0} = 3-4 pixels, where Δλ{sub 0} is defined as full width at the foot position of a spectral line, is obtained at the 80-400 Å wavelength range after careful adjustment of the grating and CCD positions. The high signal readout rate of the CCD can improve the temporal resolution of time-resolved spectra when the CCD is operated in the full vertical binning mode. It is usually operated at 5 ms per frame. If the vertical size of the CCD is reduced with a narrow slit, the time response becomes faster. The high-time response in the spectral measurement therefore makes possible a variety of spectroscopic studies, e.g., impurity behavior in long pulse discharges with edge-localized mode bursts. An absolute intensity calibration of the EUV spectrometer is also carried out with a technique using the EUV bremsstrahlung continuum at 20-150 Å for quantitative data analysis. Thus, the high-time resolution tungsten spectra have been successfully observed with good spectral resolution using the present EUV spectrometer system. Typical tungsten spectra in the EUV wavelength range observed from EAST discharges are presented with absolute intensity and spectral identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolving the very high energy emission from MGRO J2019+37 with VERITAS

We present very high energy (VHE) imaging of MGRO J2019+37 obtained with the VERITAS observatory. The bright extended (∼2°) unidentified Milagro source is located toward the rich star formation region Cygnus-X. MGRO J2019+37 is resolved into two VERITAS sources. The faint, point-like source VER J2016+371 overlaps CTB 87, a filled-center remnant (SNR) with no evidence of a supernova remnant shell at the present time. Its spectrum is well fit in the 0.65-10 TeV energy range by a power-law model with photon index 2.3 ± 0.4. VER J2019+378 is a bright extended (∼1°) source that likely accounts for the bulk of the Milagro emission and is notably coincident with PSR J2021+3651 and the star formation region Sh 2–104. Its spectrum in the range 1-30 TeV is well fit with a power-law model of photon index 1.75 ± 0.3, among the hardest values measured in the VHE band, comparable to that observed near Vela-X. We explore the unusual spectrum and morphology in the radio and X-ray bands to constrain possible emission mechanisms for this source.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of a multi-channel spin polarimeter

All commercial electron spin polarimeters work in single channel mode, which is the bottleneck of researches by spin-resolved photoelectron spectroscopy. Furthermore, by adopting the time inversion antisymmetry of the magnetic field, we developed a multichannel spin polarimeter based on normal incident very low energy electron diffraction (VLEED). The key point to achieve the multi-channel measurements is the spatial resolution of the electron optics. Thus, the test of the electron optics shows that the designed spatial resolution can be achieved and an image type spin polarimeter with 100 times 100, totally ten thousand channels is possible to be realized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the feasibility of crack detection in plate weldments through an interposed layer of viscoelastic material.

Development of new approaches in the nondestructive evaluation of welded steel plates for large naval structures continues to be an area of interest for the DoD and the military complex. In this report we will evaluate an elastic-microwave based detection and imaging method using both numerical finite element (3D FEM) and experimental methods. The evaluation was performed on two test articles that were designed to represent critical structural components with flaws of interest. Details of the materials and the mechanical drawings were provided with the test articles. Flaws, cracks and weld defects have been included in the test articles to determine detection sensitivity and accuracy of the proposed method. Our approach uses a microwave interferometer (MI) to record the scattered response of flaws in the steel plated as it is driven by an incident elastic field. The MI can “see” (penetrate) through the viscoelastic coating to the upper surface of the plate. Out-of-plane displacement amplitudes of 10nm in the frequency range (1kHz to 25kHz) are readily observable, with the key feature being, that the surface bond between the coating and the steel plate are undisturbed. The non-contact aspect of the interferometer allows for large surface regions to be accurately and efficiently scanned in space and time. Spatiotemporal data sets of this kind and specialized wavefield processing provide powerful detection and imaging modalities. From these wavefield data sets, a plate thickness mapping capability has been demonstrated that can detect thickness changes on the order of 0.79 mm (1/32”) with spatial resolution on the order of the spatial sampling rate, 15mm (~5/8”). We have also shown that a topological energy analysis of the wavefield data can detect and locate small flaws, on the order of 5-10 mm (0.025-0.40”) in the welded joint of a 1.5” thick T-plate. As before, these results are obtained through a 2” thick viscoelastic coating without altering the integrity of coating or the coating bond. These results show that we are detecting and locating damage (flaws) in the plate that are much smaller than the wavelength of the propagating guided modes. Classical scattering theory places a (λ/2) resolution limit on the detectability of flaws in terms of the incident field [22], however, since the spatial resolution of the scanned region is much smaller, (Δx=Δy=15mm) and the inherent natural focusing of the time reversal operation, we are able to detect smaller flaws on the order of (λ/10). It is important to realize that we are not imaging the flaw but detecting and localizing a difference between a reference (pristine) sample and the measured (damaged) sample, relative to a spatial grid on the surface. The current scan resolution is 15mm x 15mm. At present we cannot expect to resolve individual flaws within a grid space only their cumulative effect. Even with the current limitations, this imaging approach appears to be a promising alternative to current methods where the coating layer is removed.

36 MATERIALS SCIENCE↗

Cloud Motion Vectors from MISR using Sub-pixel Enhancements

The operational retrieval of height-resolved cloud motion vectors by the Multiangle Imaging SpectroRadiometer on the Terra satellite has been significantly improved by using sub-pixel approaches to co-registration and disparity assessment, and by imposing stronger quality control based on the agreement between independent forward and aft triplet retrievals. Analysis of the fore-aft differences indicates that CMVs pass the basic operational quality control 67% of the time, with rms differences - in speed of 2.4 m/s, in direction of 17 deg, and in height assignment of 290 m. The use of enhanced quality control thresholds reduces these rms values to 1.5 m/s, 17 deg and 165 m, respectively, at the cost of reduced coverage to 45%. Use of the enhanced thresholds also eliminates a tendency for the rms differences to increase with height. Comparison of CMVs from an earlier operational version that had slightly weaker quality control, with 6-hour forecast winds from the Global Modeling and Assimilation Office yielded very low bias values and an rms vector difference that ranged from 5 m/s for low clouds to 10 m/s for high clouds.

Davies, Roger↗

Femtosecond time-resolved MeV electron diffraction

We report the experimental demonstration of femtosecond electron diffraction using high-brightness MeV electron beams. High-quality, single-shot electron diffraction patterns for both polycrystalline aluminum and single-crystal 1T-TaS 2 are obtained utilizing a 5 fC (~3 × 10 4 electrons) pulse of electrons at 2.8 MeV. The high quality of the electron diffraction patterns confirms that electron beam has a normalized emittance of ~50 nm rad. The transverse and longitudinal coherence length is ~11 and ~2.5 nm, respectively. The timing jitter between the pump laser and probe electron beam was found to be ~100 fs (rms). The temporal resolution is demonstrated by observing the evolution of Bragg and superlattice peaks of 1T-TaS 2 following an 800 nm optical pump and was found to be 130 fs. Lastly, our results demonstrate the advantages of MeV electrons, including large elastic differential scattering cross-section and access to high-order reflections, and the feasibility of ultimately realizing below 10 fs time-resolved electron diffraction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laboratory Heat Flux Estimates of Seawater Foam for Low Wind Speeds

Laboratory experiments were conducted to measure the heat flux from seafoam continuously generated in natural seawater. Using a control volume technique, heat flux was calculated from foam and foam-free surfaces as a function of ambient humidity (ranged from 40% to 78%), air–water temperature difference (ranged from -9 °C to 0 °C), and wind speed (variable up to 3 m s-1). Water-surface skin temperature was imaged with a calibrated thermal infrared camera, and near-surface temperature profiles in the air, water, and foam were recorded. Net heat flux from foam surfaces increased with increasing wind speed and was shown to be up to four times greater than a foam-free surface. The fraction of the total heat flux due to the latent heat flux was observed for foam to be 0.75, with this value being relatively constant with wind speed. In contrast, for a foam-free surface the fraction of the total heat flux due to the latent heat flux decreased at higher wind speeds. Temperature profiles through foam are linear and have larger gradients, which increased with wind speed, while foam free surfaces show the expected logarithmic profile and show no variation with temperature. The radiometric surface temperatures show that foam is cooler and more variable than a foam-free surface, and bubble-resolving thermal images show that radiometrically transparent bubble caps and burst bubbles reveal warm foam below the cool surface layer, contributing to the enhanced variability.

54 ENVIRONMENTAL SCIENCES↗

Temporal evolution of pore geometry, fluid flow, and solute transport resulting from colloid deposition

Deposition of colloidal particles is one of many processes that lead to the evolution of the structure of natural porous media in groundwater aquifers, oil reservoirs, and sediment beds. Understanding of the mechanisms and effects of this type of structural evolution has been limited by a lack of direct observations of pore structure. Here, synchrotron X-ray difference microtomography (XDMT) was used to resolve the temporal evolution of pore structure and the distribution of colloidal deposits within a granular porous medium. Column filtration experiments were performed to observe the deposition of relatively high concentrations of colloidal zirconia (200 mg/l of particles having diameter {approx}1 {micro}m) in a packed bed of glass beads (diameters 210-300 {micro}m). Noninvasive XDMT imaging of the pore structure was performed three separate times during each column experiment. The structural information observed at each time was used to define internal boundary conditions for three-dimensional lattice Boltzmann (LB) simulations that show how the evolving pore structure affects pore fluid flow and solute transport. While the total deposit mass increased continuously over time, colloid deposition was observed to be highly heterogeneous and local colloid detachment was observed at some locations in a low ionic strength medium. LB simulations indicated that particle accumulation greatly reduced the permeability of the porous medium while increasing the tortuosity. The colloidal deposits also increased the spatial variability in pore water velocities, leading to higher dispersion coefficients. Anomalous dispersion behavior was investigated by simulation at the scale of the experimental system: weak tailing was found in the clean bed case, and the extent of tailing greatly increased following colloid deposition because of the development of extensive no-flow regions. As a result of this coupling between pore fluid flow, colloid accumulation, and the pore geometry, colloid deposition is expected to strongly influence long-term solute dynamics in cases where solute transport is either accompanied by high colloid influx or where the passage of the solute front mobilizes and then redistributes material from the porous matrix.

54 ENVIRONMENTAL SCIENCES↗

Visualizing the iron atom exchange front in the Fe(II)-catalyzed recrystallization of goethite by atom probe tomography

The autocatalytic redox interaction between aqueous Fe(II) and Fe(III)-(oxyhydr)oxide minerals such as goethite and hematite leads to rapid recrystallization marked, in principle, by an atom exchange (AE) front, according to bulk iron isotopic tracer studies. However, direct evidence for this AE front has been elusive given the analytical challenges of mass-resolved imaging at the nanoscale on individual crystallites. We report successful isolation and characterization of the AE front in goethite microrods by 3D atom probe tomography (APT). The microrods were reacted with Fe(II) enriched in tracer 57 Fe at conditions consistent with prior bulk studies. APT analyses and 3D reconstructions on cross-sections of the microrods reveal an AE front that is spatially heterogeneous, at times penetrating several nanometers into the lattice, in a manner consistent with defect-accelerated exchange. Evidence for exchange along microstructural domain boundaries was also found, suggesting another important link between exchange extent and initial defect content. The findings provide an unprecedented view into the spatial and temporal characteristics of Fe(II)-catalyzed recrystallization at the atomic scale, and substantiate speculation regarding the role of defects controlling the dynamics of electron transfer and AE interaction at this important redox interface.

Taylor, Sandra D.↗

Evidence of Reversible Oxidation at CuInSe2 Grain Boundaries

Effects related to alkali metal doping and grain boundaries have puzzled the chalcopyrite photovoltaics community for a long time. This study is the first to report reversible oxidation of grain boundaries in CuInSe2 thin films. The phenomenon is observed in sodium-doped films, but not in undoped ones. Cathodoluminescence imaging, secondary ion mass spectrometry and Kelvin probe force microscopy analyses are performed on CuInSe2 thin films before and after exposure to vacuum. The findings suggest the existence of yet unidentified solid-gas equilibria. Resolving the nature of such reactions will provide new insights into the mechanism of alkali metal doping and passivation in chalcopyrite solar cells.

14 SOLAR ENERGY↗

Three Quenched, Faint Dwarf Galaxies in the Direction of NGC 300: New Probes of Reionization and Internal Feedback

We report the discovery of three faint and ultra-faint dwarf galaxies -- Sculptor A, Sculptor B and Sculptor C -- in the direction of NGC 300 (D=2.0 Mpc), a Large Magellanic Cloud-mass galaxy. Deep ground-based imaging with Gemini/GMOS resolves all three dwarf galaxies into stars, each displaying a red giant branch indicative of an old, metal-poor stellar population. No young stars or HI gas are apparent, and the lack of a GALEX UV detection suggests that all three systems are quenched. Sculptor C (D=2.04$^{+0.10}_{-0.13}$ Mpc; $M_V=-9.1\pm 0.1$ mag or $L_V=(3.7^{+0.4}_{-0.3})\times 10^5L_{\odot})$ is consistent with being a satellite of NGC 300. Sculptor A (D=1.35$^{+0.22}_{-0.08}$ Mpc; $M_V=-6.9\pm 0.3$ mag or $L_V=(5^{+1}_{-1})\times 10^4 L_{\odot})$ is likely in the foreground of NGC 300 and at the extreme edge of the Local Group, analogous to the recently discovered ultra-faint Tucana B in terms of its physical properties and environment. Sculptor B (D=2.48$^{+0.21}_{-0.24}$ Mpc; $M_V=-8.1\pm 0.3$ mag or $L_V=(1.5^{+0.5}_{-0.4})\times 10^5L_{\odot})$ is likely in the background, but future distance measurements are necessary to solidify this statement. It is also of interest due to its quiescent state and low stellar mass. Both Sculptor A and B are $\gtrsim 2-4 r_{vir}$ from NGC 300 itself. The discovery of three dwarf galaxies in isolated or low-density environments offers an opportunity to study the varying effects of ram pressure stripping, reionization and internal feedback in influencing the star formation history of the faintest stellar systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Capacitor-type micrometeoroid detectors

The metal oxide semiconductor (MOS) capacitor micrometeroid detector consists of a thin dielectric capacitor fabricated on a silicon wafer. In operation, the device is charged to a voltage level sufficiently near breakdown that micrometeoroid impacts will cause dielectric deformation or heating and subsequent arc-over at the point of impact. Each detector is capable of recording multiple impacts because of the self-healing characteristics of the device. Support instrumentation requirements consist of a voltage source and pulse counters that monitor the pulse of recharging current following every impact. An investigation has been conducted in which 0.5 to 5 micron diameter carbonized iron spheres traveling at velocities of 4 to 10 Km/sec were impacted on to detectors with either a dielectric thickness of 0.4 or 1.0 micron. This study demonstrated that an ion microprobe tuned to sufficiently high resolution can detect Fe remaining on the detector after the impact. Furthermore, it is also possible to resolve Fe ion images free of mass interferences from Si, for example, giving its spatial distribution after impact. Specifically this technique has shown that significant amounts of impacting particles remain in the crater and near it which can be analyzed for isotopic content. Further testing and calibration could lead to quantitive analysis. This study has shown that the capacitor type micrometeroid detector is capable of not only time and flux measurements but can also be used for isotopic analysis.

Wortman, J. J.↗

SKARPS: The Search for Kuiper Belts around Radial-Velocity Planet Stars

The Search for Kuiper belts Around Radial-velocity Planet Stars - SKARPS -is a Herschel survey of solar-type stars known to have orbiting planets. When complete, the 100-star SKARPS sample will be large enough for a meaningful statistical comparison against stars not known to have planets. (This control sample has already been observed by Herschel's DUst around NEarby Stars - DUNES - key program). Initial results include previously known disks that are resolved for the first time and newly discovered disks that are fainter and colder than those typically detected by Spitzer. So far, with only half of the sample in hand, there is no measured correlation between inner RV planets and cold outer debris. While this is consistent with the results from Spitzer, it is in contrast with the relationship suggested by the prominent debris disks in imaged-planet systems.

Bryden, Geoffrey↗

Imaging nanometer-scale beamlets arrays of relativistic electron beams

In this paper we study the evolution of nanometer scale transverse density modulation of a high brightness electron beam through a drift and simple focusing channel. With the help of particle tracking simulations we analyze the effects of space charge forces, emittance and energy spread on the feasibility of recovering an initial nm-scale transverse modulation after transport through a magnifying optical system. These studies are relevant for applications such as time-resolved MeV transmission electron microscopy and in the high brightness electron beam community due to the recent developments of nano-structured cathodes and due to the possibility of taking advantage of nm-structures in the beam for coherent radiation generation.

43 PARTICLE ACCELERATORS↗