Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Advanced Communication Technology Satellite (ACTS) Multibeam Antenna On-Orbit Performance

The NASA Lewis Research Center's Advanced Communication Technology Satellite (ACTS) was launched in September 1993. ACTS introduced several new technologies, including a multibeam antenna (MBA) operating at extremely short wavelengths never before used in communications. This antenna, which has both fixed and rapidly reconfigurable high-energy spot beams (150 miles in diameter), serves users equipped with small antenna terminals. Extensive structural and thermal analyses have been performed for simulating the ACTS MBA on-orbit performance. The results show that the reflector surfaces (mainly the front subreflector), antenna support assembly, and metallic surfaces on the spacecraft body will be distorted because of the thermal effects of varying solar heating, which degrade the ACTS MBA performance. Since ACTS was launched, a number of evaluations have been performed to assess MBA performance in the space environment. For example, the on-orbit performance measurements found systematic environmental disturbances to the MBA beam pointing. These disturbances were found to be imposed by the attitude control system, antenna and spacecraft mechanical alignments, and on-orbit thermal effects. As a result, the MBA may not always exactly cover the intended service area. In addition, the on-orbit measurements showed that antenna pointing accuracy is the performance parameter most sensitive to thermal distortions on the front subreflector surface and antenna support assemblies. Several compensation approaches were tested and evaluated to restore on-orbit pointing stability. A combination of autotrack (75 percent of the time) and Earth sensor control (25 percent of the time) was found to be the best way to compensate for antenna pointing error during orbit. This approach greatly minimizes the effects of thermal distortions on antenna beam pointing.

Source record↗

Evanescent absorption based fluoride fiber sensing enhancement led by doped graphene’s thermo-optic dispersion in NIR

Evanescent wave absorption based fiber optic sensor with fluoride core, doped silica clad, amorphous silicon layer, and graphene monolayer is studied in near infrared for highly sensitive and precise recognition of melanoma in liver tissues. The findings reveal that by carefully tuning the graphene’s dispersive behavior through doping and operating at slightly increased temperature (above room temperature) can lead to significantly high sensitivity and fine resolution. An optimum combination ‘1550 nm wavelength, 0.6 eV chemical potential (of graphene), and 311.1 K temperature’ leads to 112.211 mW/RIU sensitivity and 8.91 × 10{sup −10} RIU resolution. An ultrathin silicon layer leads to better performance along with improved stability against possible oxidation and thermal issues. A detailed survey finds that the above performance (resolution, in particular) is largely superior than the fiber sensors based on different techniques. The proposed sensor can be amended accordingly for biomedical applications needing high precision of tissue/process monitoring.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Temperature-Sensitive Coating Sensor Based on Hematite

A temperature-sensitive coating, based on hematite (iron III oxide), has been developed to measure surface temperature using spectral techniques. The hematite powder is added to a binder that allows the mixture to be painted on the surface of a test specimen. The coating dynamically changes its relative spectral makeup or color with changes in temperature. The color changes from a reddish-brown appearance at room temperature (25 C) to a black-gray appearance at temperatures around 600 C. The color change is reversible and repeatable with temperature cycling from low to high and back to low temperatures. Detection of the spectral changes can be recorded by different sensors, including spectrometers, photodiodes, and cameras. Using a-priori information obtained through calibration experiments in known thermal environments, the color change can then be calibrated to yield accurate quantitative temperature information. Temperature information can be obtained at a point, or over an entire surface, depending on the type of equipment used for data acquisition. Because this innovation uses spectrophotometry principles of operation, rather than the current methods, which use photoluminescence principles, white light can be used for illumination rather than high-intensity short wavelength excitation. The generation of high-intensity white (or potentially filtered long wavelength light) is much easier, and is used more prevalently for photography and video technologies. In outdoor tests, the Sun can be used for short durations as an illumination source as long as the amplitude remains relatively constant. The reflected light is also much higher in intensity than the emitted light from the inefficient current methods. Having a much brighter surface allows a wider array of detection schemes and devices. Because color change is the principle of operation, the development of high-quality, lower-cost digital cameras can be used for detection, as opposed to the high-cost imagers needed for intensity measurements with the current methods. Alternative methods of detection are possible to increase the measurement sensitivity. For example, a monochrome camera can be used with an appropriate filter and a radiometric measurement of normalized intensity change that is proportional to the change coating temperature. Using different spectral regions yields different sensitivities and calibration curves for converting intensity change to temperature units. Alternatively, using a color camera, a ratio of the standard red, green, and blue outputs can be used as a self-referenced change. The blue region (less than 500 nm) does not change nearly as much as the red region (greater than 575 nm), so a ratio of color intensities will yield a calibrated temperature image. The new temperature sensor coating is easy to apply, is inexpensive, can contour complex shape surfaces, and can be a global surface measurement system based on spectrophotometry. The color change, or relative intensity change, at different colors makes the optical detection under white light illumination, and associated interpretation, much easier to measure and interpret than in the detection systems of the current methods.

Bencic, Timothy J.↗

Electron beam physical vapor deposition of thin ruby films for remote temperature sensing

Thermographic phosphors (TGPs) possessing temperature-dependent photoluminescence properties have a wide range of uses in thermometry due to their remote access and large temperature sensitivity range. However, in most cases, phosphors are synthesized in powder form, which prevents their use in high resolution micro and nanoscale thermal microscopy. In the present study, we investigate the use of electron beam physical vapor deposition to fabricate thin films of chromium-doped aluminum oxide (Cr-Al{sub 2}O{sub 3}, ruby) thermographic phosphors. Although as-deposited films were amorphous and exhibited weak photoluminescence, the films regained the stoichiometry and {alpha}-Al{sub 2}O{sub 3} crystal structure of the combustion synthesized source powder after thermal annealing. As a consequence, the annealed films exhibit both strong photoluminescence and a temperature-dependent lifetime that decreases from 2.9 ms at 298 K to 2.1 ms at 370 K. Ruby films were also deposited on multiple substrates. To ensure a continuous film with smooth surface morphology and strong photoluminescence, we use a sapphire substrate, which is thermal expansion coefficient and lattice matched to the film. These thin ruby films can potentially be used as remote temperature sensors for probing the local temperatures of micro and nanoscale structures.

36 MATERIALS SCIENCE↗

Low temperature thermal transport in partially perforated silicon nitride membranes.

The thermal transport in partially trenched silicon nitride membranes has been studied in the temperature range from 0.3 to 0.6 K, with the transition edge sensor (TES), the sole source of membrane heating. The test configuration consisted of Mo/Au TESs lithographically defined on silicon nitride membranes 1 {micro}m thick and 6 mm{sup 2} in size. Trenches with variable depth were incorporated between the TES and the silicon frame in order to manage the thermal transport. It was shown that sharp features in the membrane surface, such as trenches, significantly impede the modes of phonon transport. A nonlinear dependence of thermal resistance on trench depth was observed. Partial perforation of silicon nitride membranes to control thermal transport could be useful in fabricating mechanically robust detector devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

The Effects of Sensor Field-of-View on the Geometrical Characteristics of Sea Ice Leads and Implications for Large-Area Heat Flux Estimates

The release of heat from sea ice fractures ('leads') is an important component of the heat budget in the Arctic, but their impact on regional scale climate is difficult to assess without more information on their distribution in both space and time. Remote sensing of leads using satellite data, specifically AVHRR thermal and Landsat visible-band imagery, is examined empirically with respect to lead width, orientation, and area fraction. The geometrical aspects of the sensor are simulated so that the effect of sensor field-of-view on retrieved lead width statistics can be assessed. This is done using Landsat data and simulated lead networks degraded to AVHRR pixel sizes. The analyses illustrate how leads of sufficiently high contrast tend to 'grow' with increasing pixel size and how small or low contrast leads disappear. The relationship between lead contrast and the width/field-of-view ratio is also examined in order to determine the limits of lead detectability, and illustrates the multivalued nature of the problem of lead width retrieval. To help quantify the importance of changes in lead statistics, turbulent heat flux is calculated as a function of lead width and lead fraction. It is shown that pixel size has a substantial effect on estimates of turbulent heat transfer from leads to the atmosphere.

Key, J.↗

Development and Evaluation of Occupancy-Aware HVAC Control for Residential Building Energy Efficiency and Occupant Comfort

Occupancy-aware heating, ventilation, and air conditioning (HVAC) control offers the opportunity to reduce energy use without sacrificing thermal comfort. Residential HVAC systems often use manually-adjusted or constant setpoint temperatures, which heat and cool the house regardless of whether it is needed. By incorporating occupancy-awareness into HVAC control, heating and cooling can be used for only those time periods it is needed. Yet, bringing this technology to fruition is dependent on accurately predicting occupancy. Non-probabilistic prediction models offer an opportunity to use collected occupancy data to predict future occupancy profiles. Smart devices, such as a connected thermostat, which already include occupancy sensors, can be used to provide a continually growing collection of data that can then be harnessed for short-term occupancy prediction by compiling and creating a binary occupancy prediction. Real occupancy data from six homes located in Colorado is analyzed and investigated using this occupancy prediction model. Results show that non-probabilistic occupancy models in combination with occupancy sensors can be combined to provide a hybrid HVAC control with savings on average of 5.0% and without degradation of thermal comfort. Model predictive control provides further opportunities, with the ability to adjust the relative importance between thermal comfort and energy savings to achieve savings between 1% and 13.3% depending on the relative weighting between thermal comfort and energy savings. In all cases, occupancy prediction allows the opportunity for a more intelligent and optimized strategy to residential HVAC control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal conduction in a composite circular cylinder: A new technique for thermal conductivity measurements of lunar core samples

The core sample is heated from the outside at a known rate and the rise in temperature at the surface of the core tube is measured. Because the temperature at the surface, increasing with time, is a function of the thermal properties of both the core tube and the sample, the thermal properties of the sample can be estimated by comparing the measured temperature with the theory, provided that the thermal properties of the core tube are known. Thus it is not necessary to extract the sample from the core tube to make the measurements. Neither is it necessary to insert a heater, or temperature sensor, into the sample within the core tube, as would be required if another method were applied. The sample remains intact after the measurements. The temperature change in the sample can be kept to a minimum as long as the thermal conductivity determination is possible with a reasonable precision. If the radiative method of heat transfer is chosen, the core tube will only be in mechanical contact with the sample holder and a sensor attached to the core tube to measure the surface temperature, thereby greatly reducing the possibility of disturbing the sample.

Horai, K.↗

Qualifications of Bonding Process of Temperature Sensors to Deep-Space Missions

A process has been examined for bonding a platinum resistance thermometer (PRT) onto potential aerospace materials such as flat aluminum surfaces and a flexible copper tube to simulate coaxial cables for flight applications. Primarily, PRTs were inserted into a silver-plated copper braid to avoid stresses on the sensor while the sensor was attached with the braid to the base material for long-duration, deep-space missions. A1-1145/graphite composite (planar substrate) and copper tube have been used in this study to assess the reliability of PRT bonding materials. A flexible copper tube was chosen to simulate the coaxial cable to attach PRTs. The substrate materials were cleaned with acetone wipes to remove oils and contaminants. Later, the surface was also cleaned with ethyl alcohol and was air-dried. The materials were gently abraded and then were cleaned again the same way as previously mentioned. Initially, shielded (silver plated copper braid) PRT (type X) test articles were fabricated and cleaned. The base antenna material was pretreated and shielded, and CV-2566 NuSil silicone was used to attach the shielded PRT to the base material. The test articles were cured at room temperature and humidity for seven days. The resistance of the PRTs was continuously monitored during the thermal cycling, and the test articles were inspected prior to, at various intermediate steps during, and at the end of the thermal cycling as well. All of the PRTs survived three times the expected mission life for the JUNO project. No adhesion problems were observed in the PRT sensor area, or under the shielded PRT. Furthermore, the PRT resistance accurately tracked the thermal cycling of the chamber.

Ramesham, Rajeshuni↗

Ultra-High Temperature Sensors Based on Optical Property

In this program, Nuonics, Inc. has studied the fundamentals of a new Silicon Carbide (SiC) materials-based optical sensor technology suited for extreme environments of coal-fired engines in power production. The program explored how SiC could be used for sensing temperature, pressure, and potential gas species in a gas turbine environment. The program successfully demonstrated the optical designs, signal processing and experimental data for enabling both temperature and pressure sensing using SiC materials. The program via its sub-contractors also explored gas species sensing using SiC, in this case, no clear commercially deployable method was proven. Extensive temperature and pressure measurement data using the proposed SiC sensors was acquired to 1000 deg-C and 40 atms, respectively. Importantly, a first time packaged all-SiC probe design was successfully operated in a Siemens industrial turbine rig facility with the probe surviving the harsh chemical, pressure, and temperature environment during 28 days of test operations. The probe also survived a 1600 deg-C thermal shock test using an industrial flame.

01 COAL, LIGNITE, AND PEAT↗

Surface thermocouples for measurement of pulsed heat flux in the divertor of the Alcator C-Mod tokamak

A novel set of thermocouple sensors has been developed to measure heat fluxes arriving at divertor surfaces in the Alcator C-Mod tokamak, a magnetic confinement fusion experiment. These sensors operate in direct contact with the divertor plasma, which deposits heat fluxes in excess of {approx}10 MW/m{sup 2} over an {approx}1 s pulse. Thermoelectric EMF signals are produced across a non-standard bimetallic junction: a 50 {mu}m thick 74% tungsten-26% rhenium ribbon embedded in a 6.35 mm diameter molybdenum cylinder. The unique coaxial geometry of the sensor combined with its single-point electrical ground contact minimizes interference from the plasma/magnetic environment. Incident heat fluxes are inferred from surface temperature evolution via a 1D thermal heat transport model. For an incident heat flux of 10 MW/m{sup 2}, surface temperatures rise {approx}1000 deg. C/s, corresponding to a heat flux flowing along the local magnetic field of {approx}200 MW/m{sup 2}. Separate calorimeter sensors are used to independently confirm the derived heat fluxes by comparing total energies deposited during a plasma pulse. Langmuir probes in close proximity to the surface thermocouples are used to test plasma-sheath heat transmission theory and to identify potential sources of discrepancies among physical models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermally-Induced Breakouts: Insights from True-Triaxial Tests with Acoustic Emission Monitoring

Borehole breakouts are used to constrain the magnitude of maximum horizontal stress. However, when the borehole wall strength is higher than the in situ tangential stress, borehole wall failure does not develop. Additional compressive stress can be induced by heating borehole walls. To validate this concept experimentally, we conducted room-temperature and elevated temperature true-triaxial tests on Berea sandstone and Niagaran dolomite samples. We used acoustic emission sensors to capture the onset of breakout development, and we measured the temperature close to borehole wall to assess the magnitude of induced thermal hoop stress. The test results show that within a specific rock type, the breakouts develop in similar manner in room-temperature and elevated-temperature tests. Therefore, the maximum horizontal stress can be constrained from the following dataset: critical tangential stress at which breakout develops, minimum horizontal stress, elastic and thermal properties, and temperature change at the borehole wall.

Trzeciak, Maciej↗

Status of Terra MODIS Operation, Calibration, and Performance

Since launch in December 1999, Terra MODIS has successfully operated for nearly 15 years, making continuous observations. Data products derived from MODIS observations have significantly contributed to a wide range of studies of key geophysical parameters of the earth's eco-system of land, ocean, and atmosphere, and their changes over time. The quality of MODIS data products relies on the dedicated effort to monitor and sustain instrument health and operation, to calibrate and update sensor parameters and properties, and to improve calibration algorithms. MODIS observations are made in 36 spectral bands, covering wavelengths from visible to long-wave infrared. The reflective solar bands (1-19 and 26) are primarily calibrated by a solar diffuser (SD) panel and regularly scheduled lunar observations. The thermal emissive bands (20-25 and 27- 36) calibration is referenced to an on-board blackbody (BB) source. On-orbit changes in the sensor spectral and spatial characteristics are monitored by a spectroradiometric calibration assembly (SRCA). This paper provides an overview of Terra MODIS on-orbit operation and calibration activities and implementation strategies. It presents and summarizes sensor on-orbit performance using nearly 15 years of data from its telemetry, on-board calibrators, and lunar observations. Also discussed in this paper are changes in sensor characteristics, corrections applied to maintain MODIS level 1B (L1B) data quality, and efforts for future improvements.

Terra↗

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae↗

Projecting the Thermal Response in a HTGR-Type System during Conduction Cooldown Using Graph-Laplacian Based Machine Learning

Accurate prediction of an off-normal event in a nuclear reactor is dependent upon the availability of sensory data, reactor core physical condition, and understanding of the underlying phenomenon. This work presents a method to project the data from some discrete sensory locations to the overall reactor domain during conduction cooldown scenarios similar to High Temperature Gas-cooled Reactors (HTGRs). The existing models for conductive cooldown in a heterogeneous multi-body system, such as an assembly of prismatic blocks or pebble beds relies on knowledge of the thermal contact conductance, requiring significant knowledge of local thermal contacts and heat transport possibilities across those contacts. With a priori knowledge of bulk geometry features and some discrete sensors, a machine learning approach was devised. The presented work uses an experimental facility to mimic conduction cooldown with an assembly of 68 cylindrical rods initially heated to 1200 K. High-fidelity temperature data were collected using an infrared (IR) camera to provide training data to the model and validate the predicted temperature data. The machine learning approach used here first converts the macroscopic bulk geometry information into Graph-Laplacian, and then uses the eigenvectors of the Graph-Laplacian to develop Kernel functions. Support vector regression (SVR) was implemented on the obtained Kernels and used to predict the thermal response in a packed rod assembly during a conduction cooldown experiment. The usage of SVR modeling differs from most models today because of its representation of thermal coupling between rods in the core. When trained with thermographic data, the average normalized error is less than 2% over 400 s, during which temperatures of the assembly have dropped by more than 500 K. The rod temperature prediction performance was significantly better for rods in the interior of the assembly compared to those near the exterior, likely due to the model simplification of the surroundings.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Chemical Sensors Based on Optical Ring Resonators

Chemical sensors based on optical ring resonators are undergoing development. A ring resonator according to this concept is a closed-circuit dielectric optical waveguide. The outermost layer of this waveguide, analogous to the optical cladding layer on an optical fiber, is a made of a polymer that (1) has an index of refraction lower than that of the waveguide core and (2) absorbs chemicals from the surrounding air. The index of refraction of the polymer changes with the concentration of absorbed chemical( s). The resonator is designed to operate with relatively strong evanescent-wave coupling between the outer polymer layer and the electromagnetic field propagating along the waveguide core. By virtue of this coupling, the chemically induced change in index of refraction of the polymer causes a measurable shift in the resonance peaks of the ring. In a prototype that has been used to demonstrate the feasibility of this sensor concept, the ring resonator is a dielectric optical waveguide laid out along a closed path resembling a racetrack (see Figure 1). The prototype was fabricated on a silicon substrate by use of standard techniques of thermal oxidation, chemical vapor deposition, photolithography, etching, and spin coating. The prototype resonator waveguide features an inner cladding of SiO2, a core of SixNy, and a chemical-sensing outer cladding of ethyl cellulose. In addition to the ring Chemical sensors based on optical ring resonators are undergoing development. A ring resonator according to this concept is a closed-circuit dielectric optical waveguide. The outermost layer of this waveguide, analogous to the optical cladding layer on an optical fiber, is a made of a polymer that (1) has an index of refraction lower than that of the waveguide core and (2) absorbs chemicals from the surrounding air. The index of refraction of the polymer changes with the concentration of absorbed chemical( s). The resonator is designed to operate with relatively strong evanescent-wave coupling between the outer polymer layer and the electromagnetic field propagating along the waveguide core. By virtue of this coupling, the chemically induced change in index of refraction of the polymer causes a measurable shift in the resonance peaks of the ring. In a prototype that has been used to demonstrate the feasibility of this sensor concept, the ring resonator is a dielectric optical waveguide laid out along a closed path resembling a racetrack (see Figure 1). The prototype was fabricated on a silicon substrate by use of standard techniques of thermal oxidation, chemical vapor deposition, photolithography, etching, and spin coating. The prototype resonator waveguide features an inner cladding of SiO2, a core of SixNy, and a chemical-sensing outer cladding of ethyl cellulose. In addition to the ring res

Homer, Margie↗

Design and Analysis for the Carbon Fiber Composite Support Structure for Layer 0 of the D0 Silicon Micro Tracker

The support structures for the new Layer 0 (Figures 1, 2, 3) of the Run 2b silicon tracker in D0 were designed and fabricated at the University of Washington. These structures were required to have minimum mass, yet be very rigid so as to meet the high precision requirements placed on the position of the silicon detector chips. They also have to provide for cooling to remove the heat generated by the sensors and signal processing electronics and to keep the sensors at the desired operating temperature (below -5 C). All of these requirements were best met by carbon fiber/epoxy composite technology. State of the art carbon fiber materials have extremely high Young's moduli and high thermal conductivity. Appropriate fiber lay-ups and fabrication methods have been developed and used successfully to produce both various prototype structures and the structures used in the production Layer 0. The geometry of these structures was determined mainly by the geometry of the sensors themselves. The structures incorporated a complete cooling system consisting of extruded PEEK coolant tubes and distribution manifolds made from carbon fiber composites. In order to determine the mechanical and thermal performance of the structures, detailed FEA analyses of L0 have been carried out and are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗