At least 1,549 records · Page 86

Progress, Performance, and Prospects of Ultra-High Resolution Microcalorimeter Spectrometers

In 2005 the LANL/NIST team used a single high-resolution microcalorimeter detector to measure the gamma-ray spectrum of a plutonium sample. After more than a decade of research and development on this topic, both the technology and our general understanding of its capabilities have advanced greatly, such that a progress review is now timely. We examine the scenario of a large-scale reprocessing plant and conclude that current non-destructive analysis (NDA) methods are inadequate to safeguard such a facility to the desired levels, leading to undesirable dependence on massspectrometry (MS) destructive analysis (DA). The development of microcalorimeter detectors is intended to close the performance gap between NDA and DA methods to address the needs of nuclear facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UF6 Alpha Spectrometer

The goals of this project are to share a modelling study on the optimization detector-source setup, experimental UF6 measurements assessing UF6 deposition method, and an evaluation of alpha spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Throughput Method for Strontium Isotope Analysis by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometer

This technical report presents the details of the Sr column configuration and the high-throughput Sr separation protocol. Data showing the performance of the method as well as the best practices for optimizing Sr isotope analysis by MC-ICP-MS is presented. Lastly, this report offers tools for data handling and data reduction of Sr isotope results from the Thermo Scientific Neptune software to assist in data quality assurance, which help avoid issues of data glut associated with high sample throughput rapid analysis.

47 OTHER INSTRUMENTATION↗

Advanced Compact X-ray Spectrometer with High Resolution and Efficiency

Under this Phase I SBIR Project, the Square One engineering team (in collaboration with a team of scientists from Brookhaven National Laboratory) designed, built, and tested a prototype Modular X-Ray Detection System. This Detection System was comprised of two primary subsystems, the Aiming Mechanism and the Optics Train. The Optics Train can be further subdivided into the following three components: the Collection Optic, the Discrimination Optic, and the Detection Unit. It is these three components that determine the modularity of the System. For example, the Collection Optic could accommodate either a polycapillary half lens or a Soller Slit. Similarly, the Detection Unit could accommodate either a Silicon Drift Diode (SDD) or some other diode. The Discrimination Optic can be included in the Optics Train, but is not necessary to the operation of the System.

99 GENERAL AND MISCELLANEOUS↗

24.1.3.1.1 – Frisch Grid CZT Spectrometer

During FY18, BNL continued helping FLIR to integrate the instrument prototype, improving the readout software and testing electronics. BNL and LLNL carried out more measurements with the 4x4 arrays in laboratory conditions using several Cs sources and reanalyzed the raw data from the field measurements. LLNL processed the old recalibrated data and new data collected in the lab. These efforts allowed us to understand the cause of the discrepancies observed during the measurements at the Westinghouse Fuel Fabrication Facility (WFFF). The problem was traced back to the original ASIC and DAQ firmware provided by the ASIC developers. A program error and some other deficiencies were identified in the original firmware. These problems, which caused missing some detected events from the data stream, never showed up in the lab environment. So, they were not spotted before the field test. The ASIC designers are currently working to address these problems and will provide the updated firmware for the next field measurements.

36 MATERIALS SCIENCE↗

24.1.3.1.1 – Frisch Grid CZT Spectrometer

During FY18, BNL continued helping FLIR to integrate the instrument prototype, improving the readout software and testing electronics. BNL and LLNL carried out more measurements with the 4x4 arrays in laboratory conditions using several Cs sources and reanalyzed the raw data from the field measurements. LLNL processed the old recalibrated data and new data collected in the lab. These efforts allowed us to understand the cause of the discrepancies observed during the measurements at the Westinghouse Fuel Fabrication Facility (WFFF). The problem was traced back to the original ASIC and DAQ firmware provided by the ASIC developers. A program error and some other deficiencies were identified in the original firmware. These problems, which caused missing some detected events from the data stream, never showed up in the lab environment. So, they were not spotted before the field test. The ASIC designers are currently working to address these problems and will provide the updated firmware for the next field measurements.

97 MATHEMATICS AND COMPUTING↗

Calibration of Raman Spectrometer for Gas Phase Measurements

Raman spectroscopy is currently used at SRNL to measure the concentration of gaseous species evolved from chemical reactions. This report documents the methods used to calibrate the spectroscopic systems in both frequency and intensity spaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ARM shortwave spectrometers to study the clear-cloud transition zone and mixing processes

The proposed research is a collaborative effort between NASA/Goddard Space Flight Center and the Hebrew University of Jerusalem. While the NASA team focused on analyzing ground-based hyper-spectral radiance observations to understand cloud edge properties and their connection to mixing processes, the Hebrew University team tackled the problem through cloud modeling activities. By approximating the shortwave spectra in the cloud-clear transition zone as a linear combination of purely clear and purely cloudy spectra we can characterize the variations of cloud optical thickness and cloud droplet effective radius in the transition zone. When applying this method to the measurements of a ground-based shortwave spectroradiometer at the ARM’s SGP site, representing continental conditions, and MAGIC field campaign between Log Angeles, California and Honolulu, Hawaii, representing maritime scenarios, we found that cloud optical depth consistently decreases in both cases, but droplet size decreases much more substantially for the continental regime, suggesting different mixing processes for the continental and maritime conditions. The investigation and measurements of radiation clouds were coupled with a unique cloud modeling. A novel spectral bin microphysics was developed and implemented to the System of Atmospheric Modeling (SAM). In order to resolve cloud transition zones with high spatial gradients of microphysical variables a unique high resolution (10 m) was used in simulations. The model calculates droplet size distributions in each grid point. The model output was transferred to the NASA/GSFC team for utilization in radiative calculations and testing of both radiative algorithm and model representation.

54 ENVIRONMENTAL SCIENCES↗

24.1.3.1.1 - Frisch Grid CZT Spectrometer

Brookhaven National Laboratory (BNL) worked with FLIR System Inc., the manufacturer of the nanoRAIDER, to develop a handheld field deployable detector based on the novel position-sensitive virtual Frisch-grid (VFG) Cadmium-Zinc-Telluride (CdZnTe or CZT) detectors (with 1% FWHM at 662 keV or better energy resolution). The detector called nanoRAIDER-VFG would be an improvement to the current nanoRAIDER, which is a compact gamma-ray detection instrument manufactured by FLIR Systems Inc. that employs relatively lower-performing CZT hemispheric detectors (i.e., 3%-FWHM CZT detectors). The nanoRAIDER-VFG would have significantly improved accuracy of measurements while maintaining similar efficiency, as compared to the nanoRAIDER, for in-field analysis of nuclear materials and detection of undeclared activities during inspections conducted by the International Atomic Energy Agency (IAEA). Since the nanoRAIDER is currently used by the IAEA as part of its Complementary Access toolkit, a relatively quick acceptance of the nanoRAIDER-VFG for safeguards was anticipated. The nanoRAIDER-VFG project was undertaken to address the following items in the IAEA's Long-Term R&D Plan, 2012-2023: 2.2 (elemental and isotopic signatures of fuel cycle processes); 2.3 (detect signatures of undeclared activity and improve analysis); and 2.6 (detect process emanations). The high energy-resolution of the nanoRAIDER-VFG would also have had applicability to 3.2 (fissile content of metal mixtures containing actinides Np, Am, etc.). The project was not completed due to a change in priorities within FLIR.

36 MATERIALS SCIENCE↗