Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Advanced Sensor Arrays and Packaging

Novel sensor packaging elements were designed, fabricated, and tested in order to facilitate the transition of electrochemical mixed-potential sensors toward commercialization. Of the two designs completed, the first is currently undergoing field trials, taking direct measurements within vehicle exhaust streams, while the second is undergoing preliminary laboratory testing. The sensors’ optimal operating conditions, sensitivity to hydrogen, and long-­term baseline stability were also investigated. The sensing capabilities of lanthanum chromite (La 0.8 Sr 0.2 CrO 3 ) and indium-­doped tin oxide (ITO) working electrodes were compared, and the ITO devices were selected for pre-­commercial field trials testing at a hydrogen fuel cell vehicle fueling station in California. Previous data from that fueling station were also analyzed, and the causes of anomalous baseline drift were identified.

47 OTHER INSTRUMENTATION↗

USGS VDP Infrasound Sensor Evaluation

Sandia National Laboratories has tested and evaluated two infrasound sensors, the model VDP100 and VDP250, built in-house at the USGS Cascades Volcano Observatory. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, self-noise, dynamic range and nominal transfer function. Notable features of the VDP sensors include novel and durable construction and compact size.

47 OTHER INSTRUMENTATION↗

Phonon Sensor Dynamics for Cryogenic Dark Matter Search Experiment

Understanding the quasiparticle diffusion process inside sputtered aluminum (Al thin films (∼ 0.1-1 μm is critical for the Cryogenic Dark Matter Search (CDMS experiment to further optimize its detectors to directly search for dark matter. An initial study with Al films was undertaken by our group ∼ 20 years ago, but some important questions were not answered at the time. This thesis can be considered a continuation of that critical study. The CDMS experiment utilizes high purity silicon and germanium crystals to simultaneously measure ionization and phonons created by particle interactions. In addition to describing some of the rich physics involved in simultaneously detecting ionization and phonons with a CDMS detector, this thesis focuses on the detailed physics of the phonon sensors themselves, which are patterned onto CDMS detector surfaces. CDMS detectors use thin sputtered Al films to collect phonon energy when it propagates to the surfaces of the detector crystals. The phonon energy breaks Cooper pairs and creates quasiparticles (qps). These qps diffuse until they get trapped in an proximitized “overlap” region where lower-Tc tungsten films connect to the Al film. These tungsten films are the transition edge sensors (W-TESs CDMS uses to readout phonon signals. We performed a wide range of experiments using several sets of test devices designed and fabricated specifically for this work. The devices were used mostly to study quasiparticle (qp transport in Al films and qp transmission through Al/W interfaces. The results of this work are being used to optimize the design of detectors for SuperCDMS SNOLAB. This thesis is intended for CDMS collaborators who are interested in knowing more about the detailed fundamentals of how our phonon sensors work so they can take full advantage of their benefits. However, this work can also be read by general readers who are interested in particle detection using TES technology. This thesis contains eight chapters. The first chapter gives basic background information about dark matter and searches for it. We then describe the basic CDMS detector technology in Chapter two. Chapter three focuses on superconductivity and explains some of the solid state physic most relevant to our Al and W film studies. We then turn our attention to the fabrication processes used to make test devices, and describe some of the studies done to characterize our W and Al film properties. Chapter five explains the experimental setup including how a 3He/4He dilution refrigerator works, and how our electronics were configured. We then get to chapter six where we present key experimental results. Chapter seven covers the TES model we used for our test devices to simulate the data pulse shapes and reconstruct the pulse energies. We also describe the diffusion models used to fit our data. Finally, we end with a short summary of our findings and provide a few suggestions for future studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optically-based Sensor System for Critical Nuclear Facilities Post-Event Seismic Structural Assessment

The U.S. Department of Energy (DOE) has ownership and operational responsibility for a large enterprise of nuclear facilities that provide essential functions to DOE missions ranging from national security to discovery science and energy research. These facilities support a number of DOE programs and offices including the National Nuclear Security Administration, Office of Science, and Office of Environmental Management. With many unique and “one of a kind” functions, these facilities represent a tremendous national investment, and assuring their safety and integrity is fundamental to the success of a breadth of DOE programs. Many DOE critical facilities are located in regions with significant natural phenomenon hazards including major earthquakes and DOE has been a leader in developing standards for the seismic analysis of nuclear facilities. Attaining and sustaining excellence in nuclear facility design and management must be a core competency of the DOE. An important part of nuclear facility management is the ability to monitor facilities and rapidly assess the response and integrity of the facilities after any major upset event. Experience in the western U.S. has shown that understanding facility integrity after a major earthquake is a significant challenge which, lacking key data, can require extensive effort and significant time. In the work described in the attached report, a transformational approach to earthquake monitoring of facilities is described and demonstrated. An entirely new type of optically-based sensor that can directly and accurately measure the earthquake-induced deformations of a critical facility has been developed and tested. This report summarizes large-scale shake table testing of the sensor concept on a representative steel frame building structure, and provides quantitative data on the accuracy of the sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of Reflectance Pulse Oximetry Sensors Final Report CRADA No. TC-485-93

The focus of this Cooperative Research and Development Agreement (CRADA) was to design a next generation of reflectance pulse oximeter sensor. Nellcor wanted to develop an optimized reflectance pulse oximeter sensor with reduced sensitivity to the placement of the sensor (and to composition of the sampled tissue) while accurately measuring the perfusion of the tissue (i.e. oxygen saturation). Nellcor Inc. changed the company name to Nellcor-Puritan Bennett, Inc. in 1995.

47 OTHER INSTRUMENTATION↗

Magnetostrictive Cold Spray Sensor Feasibility Assessment

Ultrasound sensors and inspection systems are frequently used to generate acoustic waves in metal structures capable of detecting and characterizing cracks, pits, erosion, inclusions, weld anomalies, and other material and structural features. One significant problem with piezoelectric transducers is the difficulty to achieve good coupling between the transducer and the surface being examined. This is particularly true in harsh conditions with high temperatures, cyclical hot and cold temperatures, highly radioactive fields found near nuclear reactors or spent nuclear fuel, caustic or corrosive fluids, and other extreme environmental conditions, as well as in long-term monitoring applications where repair or replacement of the sensor is difficult or expensive. Typically, coupling between the surface and the transducer is achieved with water, gel, grease, viscous shear coupling material, or pressure, which might not be possible or appropriate for long-term applications in which the impedance -matching materials wear away, evaporate, or simply stop functioning due to changes in surface conditions. Fluid couplings can evaporate or drain away from the transducer-substrate interface; glue- based couplings may foul or fail and are notoriously unreliable at high temperatures and in radioactive environments. This work explores the behavior of a magnetostrictive cold-spray patch that is metallurgically bonded to a stainless steel inspection target surface, and compares it to the performance of a standard adhesively-bonded ferrous-cobalt magnetostrictive strip solution. Cold-spray is a coating process where 10 –100 micron diameter powdered metal is accelerated to Mach 2 to Mach 3 (2–3 × speed of sound) and impacted on the surface to be coated. Each powder particle forms a kinetic bond with the substrate or other coating particles to produce a metallurgically bonded layer. If the powder is nickel or cobalt with high magnetostrictive coefficients, this surface can serve as the base of a magnetostrictive sensor suitable for crack or pitting-damage inspection and monitoring that is not subject to temporal or environmental degradation.

47 OTHER INSTRUMENTATION↗

Final Report - Sensor Development for Future e + e - Colliders

This project advances electromagnetic calorimeter sensor development for future electron-positron colliders, particularly the International Linear Collider (ILC). The ILC, under consideration for construction in Japan, will collide electrons and positrons at a 500 GeV baseline center-of-mass collision energy. The multi-volume ILC Technical Design Report describes two detector concepts, SiD and ILD, based on their “Detailed Baseline Design” documents. SiD and ILD are continuing to develop their technologies in anticipation of a positive decision from Japan in 2018. The ILC and its detectors will make unprecedented precision measurements relating to the Higgs boson and the top quark, and search for new phenomena that could be missed at the LHC, such as electroweak particles expected in some beyond the standard models. The sensor development covered by this project primarily pertains to the electromagnetic calorimeters (EMCal). This work continues conceptual work towards realistic modules. It is important to emphasize that the HEP sensor development on this project will enable applications beyond HEP. It does not include detector engineering. This proposal is a collaboration among one National Laboratory and four universities from Japan and two National Laboratories and four universities from the U.S.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IMU integration into Sensor suite for Inspection of H-Canyon

The Purpose of this internship was to Integrate the sensor suite which will be mounted onto a robotic inspection tool used to survey the H-Canyon Air Exhaust (CAEX) tunnel the Savannah River Site. This sensor suite incorporates 3D-mapping of its surroundings, along with a 360 degree picture of its surroundings stitched in with the li-dar readings. Incorporation of the IMU would enable us to track the position of the robot inside the cave, such that the robot handlers can know where inside the exhaust tunnel the scans have been taken. The Inertial Measurement Unit (IMU) used had ROS compatibility, allowing for high leavel programming and ease of software modification. The sensor transmitted Data in the form of Acceleration. A good portion of the internship concerned the investigation of discrete integration techniques, such that we can acquire precise position information quickly.

47 OTHER INSTRUMENTATION↗

BTO 3.1.2.55 Milestone Report - Shortlist of potential sensors to be used to detect refrigerant maldistribution in HXs

This report lists the sensors that will be considered for this project to detect refrigerant maldistribution. Along with the measurement method, the table in the report also shows the unique advantages and disadvantages that each sensor has which are relevant to the planned benchtop experimental setup that will be fabricated to study refrigerant maldistribution. The actual setup will likely be fabricated with a combination of the sensors listed.

42 ENGINEERING↗

Miniature Flow and Viscosity Sensors

Integration of flow sensing into microfluidic systems such as automated sample preparation and processing has seen limited applications due to the large cost and size of commercially available flow sensors. Nevertheless, flow sensing is a critical missing components for many high precision microfluidic applications. Los Alamos National Laboratory researchers have developed a miniature flow sensor technology based on a novel microfluidic method developed at the Laboratory. The method takes advantage of the fluid-structure interaction between the fluid and an elastic membrane to provide precision measurement. Depending on how it is integrated, it is also possible to use the technology to measure viscosity of the fluid. The flow sensor can work with a wide range of fluids.

47 OTHER INSTRUMENTATION↗

Demonstration of Thermoacoustic Power Sensor

The goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-cooled Fast Reactor (SFR), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactor (LFR), Molten Salt Reactor (MSR), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the detector network placed outside of the reactor vessel. These detectors require a very small amount of power which, during loss of power events, can be provided for example by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2019 Hyperion 5313A and 5119A Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated two variations of a new model of infrasound sensor, the Hyperion 5313A and 5119A. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The Hyperion infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon Sensors for HGCal in CMS

The High-granularity Calorimeter silicon sensors suffer from leakage currents. Measurements of the leakage current as a function of temperature and reverse bias voltage were carried out using a temperature chamber and digital source-meter. In addition to analysis of the sensors, a redesigned data acquisition software was written and utilized to simplify the setup. It was determined that the sensors do follow expected behavior for the leakage current as a function of both reverse bias voltage and temperature, but there is some slight deviation at lower temperatures.

43 PARTICLE ACCELERATORS↗

Development of thinned silicon sensors on 8” wafers (CRADA FRA-2015-0015 Final Report)

Sensors fabricated from high resistivity, float zone, silicon material have been the basis of vertex detectors and trackers for the last 30 years. The areas of these devices have increased from a few square cm to >200 m 2 for the existing CMS tracker. CMS and ATLAS upgrades will each require more than 200 m 2 of silicon and the CMS High Granularity Calorimeter (HGC) will require more than 600 m 2 . Cost and complexity of assembly of these devices is related to the area of each module, which in turn is set by the area of the silicon sensors. A move from 4” and 6” wafers (the only sizes currently available) to 8” diameter in volume production has the potential for savings of tens of millions of dollars in the detector upgrade programs at the Large Hadron Collider (LHC) and future experiments. In addition to large area, the devices must be radiation hard, which can be achieved by the use of sensors thinned to 200 microns or less. The combination of wafer thinning and large wafer diameter is a significant technical challenge, and is the subject of this work.

43 PARTICLE ACCELERATORS↗

Evaluation the Geotech GS-13BH Borehole Seismic Sensor

Sandia National Laboratories has tested and evaluated the Geotech GS-13BH borehole sensor. The sensor provides a response similar to that of the standard GS-13 short-period seismic sensor intended for pier-installations in a borehole package. The purpose of this seismometer evaluation was to determine a measured sensitivity, amplitude and phase response, self-noise and dynamic range, passband and acceleration response of its calibration coil.

47 OTHER INSTRUMENTATION↗

Integration of Next Generation Critical Infrastructure Sensor Technologies

This project is focused on advancing current protective relaying and control through verifying next generation timing systems and sensors with current commercial off the shelf protective relays. This will further research in the field of advanced grid modernization and demonstrate interoperability between nextgeneration protective relays and voltage and current sensors. These commercial off the shelf (COTS) technologies were tested and integrated with next generation sensor technologies, with the results documented below.

47 OTHER INSTRUMENTATION↗

Sensor Selection for MIMO Vibration [Slides]

Objectives: Introduce a sensor selection approach to assist test engineers with MIMO test design. Demonstrate the capability of the approach. Approach: Define a desired response from a field model. Supply the sensor selection technique to two lab models, with different boundary conditions than the “field” model. Compare the laboratory response to the field response using sensors selected from the approach.

42 ENGINEERING↗

Sensor Selection for MIMO Vibration: Summary Slides [Slides]

Summary: Sensor selection approach for MIMO testing was defined and demonstrated on a model of a practical system. Laboratory response obtained using the approach matched the field response well. Information about how many control sensors, and where to locate sensors can be gleaned from the approach.

42 ENGINEERING↗