Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Crystal structure, IR and Mössbauer spectroscopy and magnetic properties of KZnFe(PO{sub 4}){sub 2} related to the zeolite-ABW-like compounds

Highlights: • The reported structure of KZnFe(PO{sub 4}){sub 2} is closely related to the zeolite ABW-type. • The structure is described in detail. • The IR and Mössbauer spectroscopy results are reported. • The magnetic properties are developed. - Abstract: The new iron phosphate KZnFe(PO{sub 4}){sub 2} has been synthesized by flux method and solid state reaction, and characterized by X-ray diffraction, IR, Mössbauer spectroscopy and magnetic susceptibility. This compound crystallizes in the monoclinic space group C2/c with the cell parameters: a = 13.514(4) Å, b = 13.273(6) Å, c = 8.742(3) Å and β = 100.07(2)°. It displays strong similarities with the phosphates KCoAl(PO{sub 4}){sub 2} and NaCoPO{sub 4} and features some analogies with the zeolite-ABW structural type. 3D framework is built up by a corner-sharing between MO{sub 4} (M = 0.5 Zn + 0.5 Fe) and PO{sub 4} tetrahedra. The K{sup +} ions are found within crossing tunnels perpendicular to the (1 0 0), (0 1 0) and (0 0 1) planes, delimited by this framework. A Mössbauer study confirmed the presence of Fe{sup 3+} ions in a tetrahedral environment. Magnetic measurements revealed an antiferromagnetic behavior with T{sub N} = 8.5 K.

36 MATERIALS SCIENCE↗

Experimental investigation of the effect of indium content on the CuIn{sub 5}S{sub 8} electrodes using electrochemical impedance spectroscopy

This paper reports on the use of electrochemical impedance spectroscopy to investigate the electrochemical behavior of spinel CuIn{sub 5}S{sub 8}/electrolyte interface. The CuIn{sub 5}S{sub 8} spinel films have been potentiostatically deposited onto indium tin oxide (ITO)-coated glass substrate. CuCl{sub 2} and InCl{sub 3} mixed solutions with different [Cu]/[In] ratios were used as cation precursor and Na{sub 2}S{sub 2}O{sub 3} as the anion precursor in acidic solution and at room temperature. The effect of the [Cu]/[In] ratio in the precursor solution on the structural, chemical stoichiometry, and morphological properties of prepared samples, as well as the electrochemical behavior of the CuIn{sub 5}S{sub 8}/electrolyte interface was investigated. The electrochemical impedance spectroscopy data have been modeled using an equivalent circuit approach. Several parameters such as, flat-band potential and free carrier concentration were determined by the change in the Mott–Schottky plots.

36 MATERIALS SCIENCE↗

X-ray photoelectron spectroscopy and ion dynamics study of W6+ doped La2Mo2O9 as SOFC electrolyte

Highlights: • Stabilization of high temperature cubic phase of La{sub 2}Mo{sub 2}O{sub 9} at room temperature by W doping. • Intra-granular pore formation in the material under reducive atmosphere. • X-ray photoelectron spectroscopic study of W doped La{sub 2}Mo{sub 2}O{sub 9} both in air and reducive atmosphere. • Partial stabilization of Mo{sup 6+} state in La{sub 2}Mo{sub 2}O{sub 9} upon W doping in reducive atmosphere. • Ion dynamics and conductivity studies for oxide ion transport. - Abstract: The structural stability of La{sub 2}Mo{sub 2-x}W{sub x}O{sub 9} is well reported by many researchers but its studies on photoelectron spectroscopy, structural behaviour in Ar-H{sub 2} (reducing) atmosphere and ion dynamics are rarely reported. Here we report for the first time, to the best of authors’ knowledge, the above studies for W-doped La{sub 2}Mo{sub 2}O{sub 9} compounds. La{sub 2}Mo{sub 2}O{sub 9} doped with W{sup 6+} over the range of 0.25 ≤ x ≤ 1.75 at Mo{sup 6+} site is synthesised by solid-state reaction route. The x-ray diffraction studies show that at x = 0.5 the lattice parameter of the unit cell starts decreasing as a consequence of decrease in bond length between various elements present in the compound. The XPS analysis shows that Mo in La{sub 2}Mo{sub 2-x}W{sub x}O{sub 9} is very much sensitive to reduction. The temperature dependent a.c. impedance spectroscopy study of La{sub 2}Mo{sub 2-0.5}W{sub 0.5}O{sub 9} has been reported over the temperature range up to 653 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of interfaces in Bornite (Cu5FeS4) fabricated Schottky diode using impedance spectroscopy method and its photosensitive behavior

Highlights: • Impedance spectroscopy study and current-voltage analysis of Bornite fabricated Schottky diode. • Analysis of interface regions of Schottky barrier diode under dc bias voltage. • Deduction of photosensing parameters for Al/Cu{sub 5}FeS{sub 4}/FTO Schottky diode. • Discussion of charge transport mechanism by employing space charge limited current (SCLC) theory. - Abstract: In this report, we have synthesized Bornite (Cu{sub 5}FeS{sub 4}) material by hydrothermal synthesis technique. The interface characteristics of Al/Cu{sub 5}FeS{sub 4}/FTO Schottky barrier diode (SBD) are investigated by using ac impedance spectroscopy (IS) analysis (under dark condition) and dc current-voltage (I–V) measurements (under dark and light both condition). IS is a powerful tool to identify the interface regions of SBDs. Ac impedance spectra of Al/Cu{sub 5}FeS{sub 4} SBD are recorded in the frequency range 40 Hz-20 MHz during dc bias scanning from -0.6 V to 0.6 V under dark condition. The diode parameter including ideality factor and barrier height is calculated from the conventional I–V measurement based on thermionic emission (TE) theory. Space charge limited current (SCLC) theory has been employed to further exemplify the improved performance of Cu{sub 5}FeS{sub 4} based SBD, which points out that the carrier mobility is enhanced ∼2-fold after irradiation of light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

γ-Ray spectroscopy using a binned likelihood approach

The measurement of a reaction cross section from a pulse height spectrum is a ubiquitous problem in experimental nuclear physics. In γ-ray spectroscopy, this is accomplished frequently by measuring the intensity of full-energy primary transition peaks and correcting the intensities for experimental artifacts, such as detection efficiencies and angular correlations. Implicit in this procedure is the assumption that full-energy peaks do not overlap with any secondary peaks, escape peaks, or environmental back- grounds. However, for complex γ-ray cascades, this is often not the case. Furthermore, this technique is difficult to adapt for coincidence spectroscopy, where intensities depend not only on the detection efficiency, but also the detailed decay scheme. We present a method that incorporates the intensities of the entire spectrum (e.g., primary and secondary transition peaks, escape peaks, Compton continua, etc.) into a statistical model, where the transition intensities and branching ratios can be determined using Bayesian statistical inference. This new method provides an elegant solution to the difficulties associated with analyzing coincidence spectra. Finally, we describe it in detail and examine its efficacy in the analysis of 18 O(p,γ) 19 F and 25 Mg(p,γ) 26 Al resonance data. For the 18 O(p,γ) 19 F reaction, the measured branching ratios improve upon the literature values, with a factor of 3 reduction in the uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron spectroscopy for pulsed beams with frame overlap using a double time-of-flight technique

A new double time-of- ight (dTOF) neutron spectroscopy technique has been developed for pulsed broad spectrum sources with a duty cycle that results in frame overlap, where fast neutrons from a given pulse overtake slower neutrons from previous pulses. Using a tunable beam at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory, neutrons were produced via thick-target breakup of 16 MeV deuterons on a beryllium target in the cyclotron vault. The breakup spectral shape was deduced from a dTOF measurement using an array of EJ-309 organic liquid scintillators. Simulation of the neutron detection efficiency of the scintillator array was performed using both GEANT4 and MCNP6. The efficiency- corrected spectral shape was normalized using a foil activation technique to obtain the energy-dependent flux of the neutron beam at zero degrees with respect to the incoming deuteron beam. The dTOF neutron spectrum was compared to spectra obtained using HEPROW and GRAVEL pulse height spectrum unfolding techniques. While the unfolding and dTOF results exhibit some discrepancies in shape, the integrated flux values agree within two standard deviations. As a result, this method obviates neutron time-of-flight spectroscopy challenges posed by pulsed beams

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3 ) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235 U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of C 7 LYC scintillators in fast neutron spectroscopy

Here, the capabilities of 7 Li-enriched Cs 2 7 LiYCl 6 (C 7 LYC) scintillation detectors for fast neutron spectroscopy are explored in benchmark experiments that exploit its excellent pulse-shape discrimination between neutrons and γ rays, and its unprecedented ≈10% energy resolution for fast neutrons in the few MeV range, obtained through the 35 Cl(n,p) reaction. Energy- and angle-resolved elastic and inelastic neutron scattering cross-section measurements of 56 Fe(n,n’) were performed at Los Alamos National Laboratory with a pulsed white neutron source and an array of 1" x 1" C 7 LYC crystals. The results convincingly establish the utility of this dual n/γ scintillator for fast neutron spectroscopy. Intrinsic efficiency measurements of both 1" x 1" and the first ever 3" x 3" C 7 LYC crystal have been initiated, using mono-energetic fast neutron beams at UMass Lowell generated via the 7 Li(p,n) reaction. Finally, the spectroscopic capabilities and potential of C 7 LYC are discussed in the context of developing this emerging scintillator for targeted science applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pulse deconvolution with adaptive shaping for real-time high-resolution high-throughput gamma spectroscopy

A high-resolution high-throughput real-time adaptive digital pulse processing system is developed for high count rate gamma-ray spectroscopy applications. The adaptive digital pulse processing algorithms are implemented on a reconfigurable FPGA and include a pulse deconvolver, adaptive shaping filter, timing filter, baseline restorer, and pile-up rejecter. Digital pulse deconvolution is implemented to reconstruct the original detector signal from the preamplifier signal, which reduces the resolution deterioration due to pulse pile-up. The deconvoluted signal is shaped with a trapezoid filter and the shaping parameter is selected adaptively based on the time separation between successive input pulses. Experimental measurements are performed with a 137Cs source under varying count-rate conditions and using germanium detectors equipped with resistive feedback and transistor reset preamplifiers (TRP). The results herein demonstrate that when using a TRP, adaptive digital signal processing allows handling 106 counts/s. In addition, the implementation of a deconvolution approach limits resolution deterioration for throughput rates that are 4 to 10 times better than achievable in typical digital and analog gamma-ray spectroscopy systems.

47 OTHER INSTRUMENTATION↗

Measurement of material isotopics and atom number ratio with α-particle spectroscopy for a NIFFTE fission Time Projection Chamber actinide target

In this work, we present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target using α-spectroscopy and mass spectrometry. The double-sided actinide target, with predominantly 239 Pu on one side and 235 U on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is needed to extract an absolute measurement fission cross-section ratio. The 239 Pu/ 235 U atom number ratio was measured with a combination of mass spectrometry and α-spectroscopy with a planar silicon detector achieving uncertainties of less than 1%. Different strategies for estimating isotopic concentration from the α-spectrum are presented to demonstrate the potential of these methods for non-destructive target assay. We found that a combination of fitting spectra with constraints from mass spectrometry, and summing counts in a region of the spectrum provided the most consistent results with the lowest uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma-ray spectroscopy using angular distribution of Compton scattering

We present a novel method to perform gamma-ray spectroscopy suitable for extreme pileup situations, wherein traditional pulse-height spectroscopy is infeasible or impractical. One example of such application is spectral characterization of intense laser-based radiation sources that employ laser wakefield acceleration, in which a large number of photons can be produced in a well-collimated beam on a picosecond or shorter timescale. The method relies on the angularly-resolved calorimetric measurement of Compton scattering. The probability for a photon to undergo Compton scattering into a given solid angle is a function of its energy and is described by the Klein–Nishina formula. By first Compton scattering the incident beam and then measuring the total energies deposited in multiple detectors placed at various scattering angles, the incident beam energy spectrum can be reconstructed without resolving the individual events in detectors. Here, we compare the performance of an maximum likelihood expectation maximization algorithm with that of an artificial neural network to measure the energy spectrum of a beam of monoenergetic gamma rays from 137Cs decay. We demonstrate that the method can be used to reconstruct the characteristic inverse Compton scattering spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Defects in N-type 4H-SiC After High-Energy N Ion Implantation by RBS-Channeling and Raman Spectroscopy

Implantation with 1 MeV N ions was performed at room temperature in n-type 4H-SiC(0001) to four implantation fluences (or doses in dpa (displacements per atom) at the damage peak) of 1.5×1013(0.0034), 7.8×1013(0.018), 1.5×1014(0.034), and 7.8×1014(0.18) ions/cm2, respectively. The evolution of disorder was studied using Rutherford backscattering spectrometry in channeling mode (RBS-C) and Raman spectroscopy. The disorder in the Si sub-lattice was found to be less than 10% for the dpa of 0.0034 and 0.0178 and increased to 40% and 60% for the dpa of 0.034 and 0.178 respectively. Raman Spectroscopy was performed using a green laser of wavelength 532 nm as excitation source. The normalized Raman Intensity, In shows disorder of 41%, 69%, 77% and 100% for the dpa of 0.0034, 0.017, 0.034 and 0.178 respectively. In this paper, the characterizations of the defects produced due to the Nitrogen implantation in 4H-SiC are presented and the results are discussed.

Environmental Molecular Sciences Laboratory↗

Kinetic study of reaction C 2 H 5 + HO 2 in a photolysis reactor with time-resolved Faraday rotation spectroscopy

The rate constant and branching ratios of ethyl reaction with hydroperoxyl radical, C 2 H 5 + HO 2 (1), a key radical-radical reaction for intermediate temperature combustion chemistry, were measured in situ for the first time in a photolysis Herriott cell by using mid-IR Faraday rotation spectroscopy (FRS) and UV-IR direct absorption spectroscopy (DAS). The microsecond time-resolved diagnostic technique in this work enabled the direct rate measurements of the target reaction at 40 and 80 mbar and reduced the experimental uncertainty considerably. C 2 H 5 and HO 2 radicals were generated by the photolysis of (COCl) 2 /C 2 H 5 I/CH 3 OH/O 2 /He mixture at 266 nm. By direct measurements of the transient profiles of C 2 H 5 , HO 2 and OH concentrations, the overall rate constant for this reaction at 297 K was determined as k 1 (40 mbar) = (3.8 ± 0.8) × 10 –11 cm 3 molecule –1 s –1 and k 1 (80 mbar) = (4.1 ± 1.0) × 10 –11 cm 3 molecule –1 s –1 . As a result, the direct observation of hydroxyl radical (OH) indicated that OH formation channel was the major channel with a branching ratio of 0.8 ± 0.1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hybrid interferometric/dispersive atomic spectroscopy of laser-induced uranium plasma

An established optical emission spectroscopy technique, laser-induced breakdown spectroscopy (LIBS), holds promise for detection and rapid analysis of elements relevant for nuclear safeguards, nonproliferation, and nuclear power, including the measurement of isotope ratios. One such important application of LIBS is the measurement of uranium enrichment ( 235 U/ 238 U), which requires high spectral resolution (e.g., 25 pm for the 424.4 nm U II line). High-resolution dispersive spectrometers necessary for such measurements are typically bulky and expensive. We demonstrate the use of an alternative measurement approach, which is based on an inexpensive and compact Fabry–Perot etalon integrated with a low to moderate resolution Czerny–Turner spectrometer, to achieve the resolution needed for isotope selectivity of LIBS of uranium in ambient air. Furthermore, spectral line widths of ~ 10 pm have been measured at a center wavelength 424.437 nm, clearly discriminating the natural from the highly enriched uranium.

47 OTHER INSTRUMENTATION↗

Analysis of geological materials containing uranium using laser-induced breakdown spectroscopy

Laser induced breakdown spectroscopy (LIBS) is a rapid atomic emission spectroscopy technique that can be configured for a variety of applications including space, forensics, and industry. LIBS can also be configured for stand-off distances or in-situ, under vacuum, high pressure, atmospheric or different gas environments, and with different resolving-power spectrometers. In this paper, the detection of uranium in a complex geological matrix under different measurement schemes is explored. Although many investigations have been completed in an attempt to detect and quantify uranium in different matrices at in-situ and standoff distances, this work detects and quantifies uranium in a complex matrix under Martian and ambient air conditions. Investigation of uranium detection using a low resolving-power LIBS system at stand-off distances (1.6 m) is also reported. The results are compared to an in-situ LIBS system with medium resolving power and under ambient air conditions. Uranium has many thousands of emission lines in the 200–800 nm spectral region. In the presence of other matrix elements and at lower concentrations, the limit of detection of uranium is significantly reduced. The two measurement methods (low and high resolving-power spectrometers) are compared for limit of detection (LOD). Of the twenty-one potential diagnostic uranium emission lines, seven (409, 424, 434, 435, 436, 591, and 682 nm) have been used to determine the LOD for pitchblende in a dunite matrix using the ChemCam test bed LIBS system. The LOD values determined for uranium transitions in air are 409.013 nm (24,700 ppm), 424.167 nm (23,780 ppm), 434.169 nm (24,390 ppm), 435.574 nm (35,880 ppm), 436.205 nm (19,340 ppm), 591.539 nm (47,310 ppm), and 682.692 nm (18,580 ppm). The corresponding LOD values determined for uranium transitions in 7 Torr CO2 are 424.167 nm (25,760 ppm), 434.169 nm (40,800 ppm), 436.205 nm (32,050 ppm), 591.539 nm (15,340 ppm), and 682.692 nm (29,080 ppm). The LOD values determine for uranium emission lines using the medium resolving power (10,000 λ/Δλ) LIBS system for the dunite matrix in air are 409.013 nm (6120 ppm), 424.167 nm (5356 ppm), 434.169 nm (5693 ppm), 435.574 nm (6329 ppm), 436.205 nm (2142 ppm), and 682.692 nm (10,741 ppm). The corresponding LOD values determined for uranium transitions in a SiO2 matrix are 409.013 nm (272 ppm), 424.167 nm (268 ppm), 434.169 nm (402 ppm), 435.574 nm (1067 ppm), 436.205 nm (482 ppm), and 682.692 nm (720 ppm). The impact of spectral resolution, atmospheric conditions, matrix elements, and measurement distances on LOD is discussed. The measurements will assist one in selecting the proper system components based upon the application and the required analytical performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate determination of uranium isotope abundances by wavelength modulation spectroscopy in atomic beams

The design and demonstration of an optical analysis system based on wavelength modulation spectroscopy in an atomic beam for uranium isotope abundance determinations is presented. This system probes the uranium 5f 3 6d7s 2 ( 5 L 6 ) → 5f 2 6d 2 7s 2 ( 5 K 5 ) transition at 861.031 nm, which is considered to be the most suitable transition for uranium isotopic analysis. A new laser characterization strategy was developed for the conditions where optimum laser wavelength modulation depth was small compared to the free spectral range (FSR) of etalons. Two capabilities enabled the higher-precision determination of isotope abundances of atomic beams: (1) reduction of low-frequency additive noise, especially the noise caused by black-body radiation and (2) suppression of non-absorption transmission losses. The performance of this system was validated with uranium samples of various isotopic compositions. Further, by comparing the measurements using natural uranium samples between the direct absorption and the wavelength modulation approaches, a 21-fold decrease in uncertainty of the integrated absorbance and a 6.8-fold improvement in the 1-σ precision of the number density were achieved. In addition, by comparing the results using uranium oxide samples, a 6.1-fold decrease in the uncertainty of inferred isotope abundance was obtained. These results demonstrate that the 1f-normalized 2f wavelength modulation spectroscopy (WMS-2f/1f) technique enables higher-precision analysis of atomic beams.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design and development of a probe-based multiplexed multi-species absorption spectroscopy sensor for characterizing transient gas-parameter distributions in the intake systems of I.C. engines

We designed and developed a 4-probe multiplexed multi-species absorption spectroscopy sensor system for gas property measurements on the intake side of commercial multi-cylinder internal-combustion (I.C.) engines; the resulting cycle- and cylinder-resolved concentration, temperature and pressure measurements are applicable for assessing spatial and temporal variations in the recirculated exhaust gas (EGR) distribution at various locations along the intake gas path, which in turn is relevant to assessing cylinder charge uniformity, control strategies, and CFD models. Furthermore, the diagnostic is based on absorption spectroscopy and includes an H 2 O absorption system (utilizing a 1.39 m distributed feedback (DFB) diode laser) for measuring gas temperature, pressure, and H 2 O concentration, and a CO 2 absorption system (utilizing a 2.7 m DFB laser) for measuring CO 2 concentration. The various lasers, optical components and detectors were housed in an instrument box, and the 1.39- m and 2.7- m lasers were guided to and from the engine-mounted probes via optical fibers and hollow waveguides, respectively. The 5kHz measurement bandwidth allows for near-crank angle resolved measurements, with a resolution of 1.2 crank angle degrees at 1000 RPM. Our use of compact stainless steel measurement probes enables simultaneous multi-point measurements at various locations on the engine with minimal changes to the base engine hardware; in addition to resolving large-scale spatial variations via simultaneous multi-probe measurements, local spatial gradients can be resolved by translating individual probes. Along with details of various sensor design features and performance, we also demonstrate validation of the spectral parameters of the associated CO 2 absorption transitions using both a multi-pass heated cell and the sensor probes.

33 ADVANCED PROPULSION SYSTEMS↗