Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIZE DETERMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Efficiency measurement techniques for calibration of a prototype 34-meter-diameter beam-waveguide antenna at 8.45 and 32 GHz

Efficiency measurements at 8.45 and 32 GHz (X and Ka bands, respectively) were carried out on the new 34 m diameter beam waveguide antenna now in use at the NASA Goldstone Deep Space Communications Complex. The use of portable test packages enabled measurements at both the Cassegrain and beam waveguide focal points. Radio sources (quasars and Venus) were used as calibrators, and updated determinations of flux and source size correction were made during the period of the measurements. Gain and efficiency determinations as a function of elevation angle are presented, and the effects of the beam waveguide system and antenna structure are clearly seen. At the beam waveguide focus, an 8.45 GHz peak efficiency of 72.38 pct was measured; at 32 GHz, 44.89 pct was measured.

Slobin, Stephen D.↗

Low-Energy Ion Scattering Intensities from Supported Nanoparticles: The Spherical Cap Model

Supported nanoparticles are of great importance to many technologies like fuel processing and chemical synthesis using catalysts and electrocatalysts, energy storage and generation using fuel cells and batteries, electrochemistry, magnetic information storage, and more. Low-energy ion scattering spectroscopy (LEIS) with noble gas ions like He+ is a powerful tool for the characterization of nanoparticles dispersed across flat support surfaces due to its ability to probe the elemental composition in the topmost atomic layer of a surface, providing quantitative information regarding the size and number density of nanoparticles. In this work, we present a derivation of the LEIS intensities expected from nanoparticles and the support material as a function of the average particle size, their number per unit area, and their contact angle with the support when modeled as spherical caps of the nanoparticle material dispersed over the surface of a flat support. The model assumes that the ion intensities are determined only by the physical blocking of linear ion trajectories and independent of the tilt angle of the local surface relative to the incident and scattered ion directions, an assumption we support by quantitative modeling of published data which tested tilt-angle effects. The model is a generalization to arbitrary contact angles of the hemispherical cap model, which assumes 90° contact angle and has been widely used to model spectroscopic signals in LEIS (and also in Auger and photoelectron spectroscopies) during nanoparticle growth. Here, this new model quantitatively reveals how LEIS signals are sensitive not only to the diameter and number density of the nanoparticle but also to their contact angle (or height/diameter ratio). With the use of additional data (e.g., from microscopy or adsorption microcalorimetry), the model presented here will enable more accurate determination of the average size, shape, and number density of supported nanoparticles based on LEIS intensity measurements.

99 GENERAL AND MISCELLANEOUS↗

SU-F-T-157: Physics Considerations Regarding Dosimetric Accuracy of Analytical Dose Calculations for Small Field Proton Therapy: A Monte Carlo Study

Purpose: To evaluate the accuracy of dose calculations by analytical dose calculation methods (ADC) for small field proton therapy in a gantry based passive scattering facility. Methods: 50 patients with intra-cranial disease were evaluated in the study. Treatment plans followed standard prescription and optimization procedures of proton stereotactic radiosurgery. Dose distributions calculated with the Monte Carlo (MC) toolkit TOPAS were used to represent delivered treatments. The MC dose was first adjusted using the output factor (OF) applied clinically. This factor is determined from the field size and the prescribed range. We then introduced a normalization factor to measure the difference in mean dose between the delivered dose (MC dose with OF) and the dose calculated by ADC for each beam. The normalization was determined by the mean dose of the center voxels of the target area. We compared delivered dose distributions and those calculated by ADC in terms of dose volume histogram parameters and beam range distributions. Results: The mean target dose for a whole treatment is generally within 5% comparing delivered dose (MC dose with OF) and ADC dose. However, the differences can be as great as 11% for shallow and small target treated with a thick range compensator. Applying the normalization factor to the MC dose with OF can reduce the mean dose difference to less than 3%. Considering range uncertainties, the generally applied margins (3.5% of the prescribed range + 1mm) to cover uncertainties in range might not be sufficient to guarantee tumor coverage. The range difference for R90 (90% distal dose falloff) is affected by multiple factors, such as the heterogeneity index. Conclusion: This study indicates insufficient accuracy calculating proton doses using ADC. Our results suggest that uncertainties of target doses are reduced using MC techniques, improving the dosimetric accuracy for proton stereotactic radiosurgery. The work was supported by NIH/NCI under CA U19 021239. CG was partially supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087).

60 APPLIED LIFE SCIENCES↗

Novel Methods to Determine Feeder Locational PV Hosting Capacity and PV Impact Signatures

Often PV hosting capacity analysis is performed for a limited number of distribution feeders. For medium - voltage distribution feeders, previous results generally analyze less than 20 feeders, and then the results are extrapolated out to similar types of feeders. Previous hosting capacity research has often focused on determining a single value for the hosting capacity for the entire feeder, whereas this research expands previous hosting capacity work to investigate all the regions of the feeder that may allow many different hosting capacity values wit h an idea called locational hosting capacity (LHC)to determine the largest PV size that can be interconnected at different locations (buses) on the study feeders. This report discusses novel methods for analyzing PV interconnections with advanced simulati on methods. The focus is feeder and location - specific impacts of PV that determine the locational PV hosting capacity. Feeder PV impact signature are used to more precisely determine the local maximum hosting capacity of individual areas of the feeder. T he feeder signature provides improved interconnection screening with certain zones that show the risk of impact to the distribution feeder from PV interconnections.

30 DIRECT ENERGY CONVERSION↗

NASA-Langley Research Center's participation in a round-robin comparison between some current crack-propagation prediction methods

A round-robin study was conducted which evaluated and compared different methods currently in practice for predicting crack growth in surface-cracked specimens. This report describes the prediction methods used by the Fracture Mechanics Engineering Section, at NASA-Langley Research Center, and presents a comparison between predicted crack growth and crack growth observed in laboratory experiments. For tests at higher stress levels, the correlation between predicted and experimentally determined crack growth was generally quite good. For tests at lower stress levels, the predicted number of cycles to reach a given crack length was consistently higher than the experimentally determined number of cycles. This consistent overestimation of the number of cycles could have resulted from a lack of definition of crack-growth data at low values of the stress intensity range. Generally, the predicted critical flaw sizes were smaller than the experimentally determined critical flaw sizes. This underestimation probably resulted from using plane-strain fracture toughness values to predict failure rather than the more appropriate values based on maximum load.

Hudson, C. M.↗

Propagation of flexural and membrane waves with fluid loaded NASTRAN plate and shell elements

Modeling of flexural and membrane type waves existing in various submerged (or in vacuo) plate and/or shell finite element models that are excited with steady state type harmonic loadings proportioned to e(i omega t) is discussed. Only thin walled plates and shells are treated wherein rotary inertia and shear correction factors are not included. More specifically, the issue of determining the shell or plate mesh size needed to represent the spatial distribution of the plate or shell response is of prime importance towards successfully representing the solution to the problem at hand. To this end, a procedure is presented for establishing guide lines for determining the mesh size based on a simple test model that can be used for a variety of plate and shell configurations such as, cylindrical shells with water loading, cylindrical shells in vacuo, plates with water loading, and plates in vacuo. The procedure for doing these four cases is given, with specific numerical examples present only for the cylindrical shell case.

Kalinowski, A. J.↗

Determination of the quality index (Q) for photon beams at arbitrary field sizes

Purpose: A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR{sub 20,10}) for a square field of 10x10 cm{sup 2} and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly required in dosimetry protocols, but certainly influences the measurement of Q, is not always produced. In this work, a method was developed in order to determine Q at any field size, especially for small and nonflattened beams. Methods: An analytical relationship was derived between TPR{sub 20,10} for arbitrary field sizes and Q[the TPR{sub 20,10}(10x10 cm{sup 2})] as quality index. The proposed model equation was fitted to the measured and published data in order to achieve three general fit parameters. The procedure was then tested with published data from TomoTherapy and CyperKnife treatment devices. Results: For standard flattened photon fields, the uncertainty in Q measured at any field size using the parameters derived from this study is better than 1%. In flattening-filter free beams, the proposed procedure results in a reliable Q for any field size setting. Conclusions: A method is introduced and successfully tested in order to measure the beam quality under nonstandard conditions. It can be used, e.g., to get energy dependent correction factors as tabulated in dosimetry codes of practice even if standard conditions are not adjustable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Size and metabolic properties of fibers in rat fast-twitch muscles after hindlimb suspension

The effect of hind-limb suspension (HS) on single fibers of the medial gastrocnemius (MG) and the tibialis anterior (TA) muscles were studied in rats. Fiber area and the activities of succinate dehydrogenase (SDH) and alpha-glycerophosphate dehydrogenase (GPD) were determined in tissue sections using an image analysis system. After 28 days of HS, the MG atrophied 28 percent, whereas the TA weight was maintained. Both dark- and light-ATPase fibers in the deep region of the MG had decreased cross-sectional areas following HS, with the atrophic response being twice as great in the light-ATPase fibers than in the dark-ATPase fibers. Following HS, mean SDH activities of both fiber types were significantly lower in the MG and TA than in the CON; by contrast, mean GPD activities were either maintained at the CON level or were higher in both MG and TA muscles. The data suggest an independence of the mechanisms determining the muscle fiber size and the metabolic adaptations associated with HS.

Roy, Roland R.↗

Particle Size-Dependent Zero-Field Exchange Bias in LaFeO {sub 3} Nanoparticles

The present communication deals with particle size-dependent zero-field cooled exchange effect in LaFeO{sub 3} (LFO). LFO nanoparticles were prepared by PVA-based sol-gel method. The sample was calcined at different temperatures (700, 750, and 800 {sup ∘}C) to tune the average particle size. The detailed crystal structural and their geometrical parameters were examined by means of Rietveld refinement using x-ray diffraction data. The different techniques such as Scherrer’s method, Williamson Hall method, FESEM, and TEM were applied to accurately determine the average particle size. Zero-field cooled exchange bias and weak ferromagnetism in antiferromagnetic nanoparticles was observed for all samples using hysteresis loop measurement. The training effect was studied to confirm that the loop shift originates due to exchange bias. Exchange bias as well as coercivity are strongly related to the particle size at low and room temperature. The results clearly demonstrate that the process of calcination tailor the overall properties of material which makes it a promising candidate for device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects associated with nanostructure fabrication using in situ liquid cell TEM technology

We studied silicon, carbon, and SiC x nanostructures fabricated using liquid-phase electron-beam-induced deposition technology in transmission electron microscopy systems. Nanodots obtained from fixed electron beam irradiation followed a universal size versus beam dose trend, with precursor concentrations from pure SiCl 4 to 0 % SiCl 4 in CH 2 Cl 2 , and electron beamintensity ranges of two orders of magnitude, showing good controllability of the deposition. Secondary electrons contributed to the determination of the lateral sizes of the nanostructures, while the primary beam appeared to have an effect in reducing the vertical growth rate. These results can be used to generate donut-shaped nanostructures. Using a scanning electron beam, line structures with both branched and unbranched morphologies were also obtained. As a result, the liquid-phase electron-beam induced deposition technology is shown to be an effective tool for advanced nanostructured material generation.

36 MATERIALS SCIENCE↗

Phase diagrams and polarization reversal in nanosized Hf x Zr 1–x O 2–y

To describe the polar properties of nanosized Hf x Zr 1–x O 2–y , we evolve the “effective” Landau–Ginzburg–Devonshire (LGD) model based on the parametrization of the Landau expansion coefficients for polar and antipolar orderings. We have shown that the effective LGD model can predict the influence of screening conditions and size effects on phase diagrams, polarization reversal, and structural properties of nanosized Hf x Zr 1–x O 2–y of various shapes and sizes. To verify the model, we use the available experimental results for Hf x Zr 1–x O 2 thin films and oxygen-deficient HfO2–y nanoparticles prepared under different annealing conditions. X-ray diffraction, which was used to determine the phase composition of the HfO 2–y nanoparticles, revealed the formation of a ferroelectric orthorhombic phase in them. Micro-Raman spectroscopy was used to explore the correlation of lattice dynamics and structural changes that depend on the oxygen vacancy concentration in the HfO 2–y nanoparticles. Since our approach allows us to determine the conditions (shape, sizes, Zr content, and/or oxygen vacancy amount) for which nanosized Hf x Zr 1–x O 2–y are ferroelectric or antiferroelectric, we hope that the obtained results are useful for creation of next generation Si-compatible ferroelectric gate oxide nanomaterials.

36 MATERIALS SCIENCE↗

Improvement of hot-electron and gamma-ray yields by selecting preplasma thickness for a target irradiated by a short laser pulse

The dependences of the temperature and the number of hot electrons on the size of the plasma corona of a thin foil target irradiated by a short relativistically intense laser pulse are investigated by three-dimensional numerical simulations. For a 30-fs long laser pulse with an energy of 300 mJ we have determined the optimal preplasma size which maximises the yield of forward-accelerated electrons capable of generating gamma-ray photons several MeV in energy. A study is made of gamma-ray generation by such laser-accelerated electrons in the bombardment of a converter target placed behind the laser target; the brightness of this gamma-ray source is shown to range up to 10{sup 15} photons s{sup −1} mrad{sup −2} mm{sup −2} × (0.1 % BW){sup −1}. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A real-time phase-space beam emittance monitoring system

An electron beam position and angle monitoring system, ps-BPM, has been shown to be able to measure the electron source position and angle at a single location in a beamline at a synchrotron source. This system uses a monochromator to prepare a photon beam whose energy is at that of the K -edge of an absorber filter. The divergence of the beam from the source gives an energy range that will encompass the K -edge of the filter. A measurement of the centre of the monochromatic beam and the K -edge location through the absorber filter gives the position and angle of the electron source. Here, it is shown that this system is also capable of measuring the source size and divergence at the same time. This capability is validated by measurement as the beam size in the storage ring was changed and by ray-tracing simulations. The system operates by measuring the photon beam spatial distribution as well as a K -edge filtered beam distribution. These additional measurements result in the ability to also determine the electron source size and divergence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sn/SnOx Core-Shell Nanospheres: Synthesis, Anode Performance in Li Ion Batteries, and Superconductivity

Sn/SnO{sub x} core?shell nanospheres have been synthesized via a modified polyol process. Their size can be readily controlled by tuning the usage of surface stabilizers and the temperature. Anode performance in Li ion batteries and their superconducting properties is detailed. As anode materials, 45 nm nanospheres outperform both larger and smaller ones. Thus, they exhibit a capacity of about 3443 mAh cm{sup -3} and retain about 88% of after 10 cycles. We propose a model based on the microstructural evolution to explain the size impact on nanosphere performance. Magnetic measurements indicate that the nanospheres become superconducting below the transition temperature T{sub C} = 3.7 K, which is similar to the value obtained in bulk tin. Although T{sub C} does not significantly change with the size of the Sn core, we determined that the critical field H{sub C} of nanospheres can be as much as a factor of 30 larger compared to the bulk value. Alternating current measurements demonstrated that a transition from conventional to filamentary superconducting structure occurs in Sn/SnO{sub x} particles as their size increases. The transition is determined by the relationship between the particle size and the magnetic field penetration depth.

25 ENERGY STORAGE↗

Thermal reaction processes in a relativistic QED plasma drop

The equilibrium size and temperature limits of thermally and chemically equilibrated e{sup +}e{sup -{gamma}} plasma drops are investigated at a given energy content. For a plasma to be equilibrated it must be opaque to electron and photon interactions. The opaqueness condition is determined by comparing plasma size with the mean free electron and photon paths. We calculate those paths using thermal Lorentz-invariant reaction rates for pair production and electron (positron) and photon scattering. The range of the corresponding plasma temperature and size is evaluated numerically. Considering the energy and size we find that the opaque and equilibrated plasma drop may be experimentally attainable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The sizes of globular clusters as tracers of galactic halo potentials

We present N-body simulations of globular clusters, exploring the effect of different galactic potentials on cluster sizes, r{sub h}. For various galactocentric distances, R{sub G}, we assess how cluster sizes change when we vary the virial mass and concentration of the host galaxy’s dark-matter halo. We show that sizes of GCs are determined by the local galactic mass density rather than the virial mass of the host galaxy. We find that clusters evolving in the inner halos of less concentrated galaxies are significantly more extended than those evolving in more concentrated ones, while the sizes of those orbiting in the outer halo are almost independent of concentration. Adding a baryonic component to our galaxy models does not change these results much, since its effect is only significant in the very inner halo. Our simulations suggest that there is a relation between r{sub h} and R{sub G}, which systematically depends on the physical parameters of the halo. Hence, observing such relations in individual galaxies can put a new observational constraint on dark-matter halo characteristics. However, by varying the halo mass in a wide range of 10{sup 9}⩽M{sub vir}/M{sub ⊙}⩽10{sup 13}, we find that the r{sub h} − R{sub G} relationship will be nearly independent of halo mass, if one assumes M{sub vir} and c{sub vir} as two correlated parameters, as is suggested by cosmological simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

The Solar System Beyond Neptune

The aim of this research is to study the objects in the Kuiper Belt, in order to understand the nature of its origin and the evolutionary processes which have affected the Kuiper Belt. Particular science objectives include: 1) the determination of the sky-plane surface density of Kuiper Belt Objects (KBOs); 2) the determination of the slope of the cumulative luminosity function (CLF); 3) the determination of the KBO size distribution; 4) the isolation of bright KBOs from which physical measurements can be secured using existing 10-meter diameter class telescopes; 5) physical measurements of bright KBOs designed to assess their composition. Major results obtained under the grant include: 1) The determination of the surface density of KBOs (objects per square degree of sky) as a function of apparent red magnitude in the range 21 less than MR less than 24.8. 2) The discovery of a new dynamical class in the Kuiper Belt, exemplified by 1996 TL66. 3) Physical observations of two bright KBOs were secured using the Keck 10-meter telescope and an infrared imager/spectrometer; 4) In support of public interest in the Kuiper Belt, we wrote a popular article for Scientific American magazine and we developed a "Kuiper Belt Home Page" on the world-wide web.

Jewitt, David↗

Towards Automated and High-Throughput Quantitative Sizing and Isotopic Analysis of Nanoparticles via Single Particle-ICP-TOF-MS

The work described herein assesses the ability to characterize gold nanoparticles (Au NPs) of 50 and 100 nm, as well as 60 nm silver shelled gold core nanospheres (Au/Ag NPs), for their mass, respective size, and isotopic composition in an automated and unattended fashion. Here, an innovative autosampler was employed to mix and transport the blanks, standards, and samples into a high-efficiency single particle (SP) introduction system for subsequent analysis by inductively coupled plasma–time of flight–mass spectrometry (ICP-TOF-MS). Optimized NP transport efficiency into the ICP-TOF-MS was determined to be >80%. This combination, SP-ICP-TOF-MS, allowed for high-throughput sample analysis. Specifically, 50 total samples (including blanks/standards) were analyzed over 8 h, to provide an accurate characterization of the NPs. This methodology was implemented over the course of 5 days to assess its long-term reproducibility. Impressively, the in-run and day-to-day variation of sample transport is assessed to be 3.54 and 9.52% relative standard deviation (%RSD), respectively. The determination of Au NP size and concentration was of <5% relative difference from the certified values over these time periods. Isotopic characterization of the 107 Ag/ 109 Ag particles (n = 132,630) over the course of the measurements was determined to be 1.0788 ± 0.0030 with high accuracy (0.23% relative difference) when compared to the multi-collector–ICP-MS determination.

36 MATERIALS SCIENCE↗