Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SERVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Quantitative Evaluation of MD/HD Vehicle Electrification using Statistical Data

This paper presents a wide-ranging analysis of Class 3-8 commercial vehicle electrification by means of developing a framework tool which uses a quantitative method of estimating electric vehicle energy consumption and appropriate charging considerations. The Fleet DNA composite statistics on real-world driving behavior is used to evaluate feasible or market-ready battery electric vehicle (BEV) technologies in medium- and heavy-duty (MD/HD) applications. In the paper, ten representative Class 3-8 commercial vehicle electrifications have been evaluated as a function of various service coverages, including applications in port drayage tractors, refuse trucks, delivery trucks, buses, and bucket trucks. The results indicate significant energy savings and fuel cost savings across all MD/HD vehicle electrifications. The majority of MD BEVs, with the exception of Class 3 bucket trucks, achieve better than a 5-year payback with 50–75% service coverage. For HD BEVs, with the exception of the Class 8 port drayage tractors, the 90% service coverage results in a 10-year or longer payback time, while the 50% service coverage yields a 7–8 year payback. Class 8 port drayage tractors should achieve payback in no more than a 3.5 years with 50–75% service coverage. Thus, the analysis indicates a highly feasible potential for Class 3-6 MD vehicles to be electrified, and feasible opportunities for electrification in Class 7-8 HD short-distance applications.

33 ADVANCED PROPULSION SYSTEMS↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Contribution of Tibetan Plateau ecosystems to local and remote precipitation through moisture recycling

The ecosystems of the Tibetan Plateau (TP) provide multiple important ecosystem services that benefit both local populations and those beyond, such as through climate regulation services on precipitation for East Asia and China. However, the precipitation regulation service of the TP ecosystems for supplying moisture and maintaining precipitation is yet to be evaluated. In this study, we used the moisture recycling framework and a moisture tracking model to quantify the precipitation regulation services of TP ecosystems for their contribution to precipitation. We found TP ecosystems contributed substantially to local and downwind precipitation, with a declined contribution from 221 mm/year for the TP and neighboring areas, to <10 mm/year for eastern China and other surrounding countries. Among ecosystem types, grassland contributed most to precipitation, followed by barren and snow lands, forests, and shrublands. In terms of seasonality, precipitation contribution from TP ecosystems was greater in summer months than in non-summer months for western China, while the opposite was true for eastern China – though the magnitude was much smaller. Over the past two decades, the significant evapotranspiration increases in TP translated to a widespread increase in precipitation contribution for TP and downwind beneficiary regions from 2000 to 2020. Our study provides a quantitative way to understand the precipitation regulation services of TP ecosystems through moisture recycling, substantiating their key role to safeguard precipitation and the water cycle for downwind regions– effectively acting as an ecological security shelter that could be perceived by the public.

Li, Yan↗

Cost comparison between private and public collection of residual household waste: Multiple case studies in the Flemish region of Belgium

Highlights: Black-Right-Pointing-Pointer The goal is to compare collection costs for residual household waste. Black-Right-Pointing-Pointer We have clustered all municipalities in order to find mutual comparable pairs. Black-Right-Pointing-Pointer Each pair consists of one private and one public operating waste collection program. Black-Right-Pointing-Pointer All cases show that private service has lower costs than public service. Black-Right-Pointing-Pointer Municipalities were contacted to identify the deeper causes for the waste management program. - Abstract: The rising pressure in terms of cost efficiency on public services pushes governments to transfer part of those services to the private sector. A trend towards more privatizing can be noticed in the collection of municipal household waste. This paper reports the findings of a research project aiming to compare the cost between the service of private and public collection of residual household waste. Multiple case studies of municipalities about the Flemish region of Belgium were conducted. Data concerning the year 2009 were gathered through in-depth interviews in 2010. In total 12 municipalities were investigated, divided into three mutual comparable pairs with a weekly and three mutual comparable pairs with a fortnightly residual waste collection. The results give a rough indication that in all cases the cost of private service is lower than public service in the collection of household waste. Albeit that there is an interest in establishing whether there are differences in the costs and service levels between public and private waste collection services, there are clear difficulties in establishing comparisons that can be made without having to rely on a large number of assumptions and corrections. However, given the cost difference, it remains the responsibility of the municipalities to decide upon the service they offer their citizens, regardless the cost efficiency: public or private.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inferring Netflow Data

Netflow data is a specific format for looking at network traffic. With this format, many security tests are easy to run. Cloud Service Providers produce logs that do not contain all of the content that Netflow data contains. There is a possibility that the fields that are in Netflow data but absent in Cloud Service Provider logs can be inferred from the fields that are present in the Cloud Service Provider logs. By inferring the missing data fields, the same test that can be run with Netflow data would be possible to run on the logs produced by Cloud Service Providers. Cloud Service Providers include Amazon Web Services and Box.com. There are multiple different types of Cloud Services, and each provider handles them differently and produces different logs. There are IaaS (meaning infrastructure as a service), Saas (meaning software as a service), and Paas (meaning platform as a service). Each provides a different use for the user.

97 MATHEMATICS AND COMPUTING↗

QoS-aware edge AI placement and scheduling with multiple implementations in FaaS-based edge computing

Resource constraints on the computing continuum require that we make smart decisions for serving AI-based services at the network edge. AI-based services typically have multiple implementations (e.g., image classification implementations include SqueezeNet, DenseNet, and others) with varying trade-offs (e.g., latency and accuracy). The question then is how should AI-based services be placed across Function-as-a-Service (FaaS) based edge computing systems in order to maximize total Quality-of-Service (QoS). To address this question, we propose a problem that jointly aims to solve (i) edge AI service placement and (ii) request scheduling. These are done across two time-scales (one for placement and one for scheduling). Here we first cast the problem as an integer linear program. We then decompose the problem into separate placement and scheduling subproblems and prove that both are NP-hard. We then propose a novel placement algorithm that places services while considering device-to-device communication across edge clouds to offload requests to one another. Our results show that the proposed placement algorithm is able to outperform a state-of-the-art placement algorithm for AI-based services, and other baseline heuristics, with regard to maximizing total QoS. Additionally, we present a federated learning-based framework, FLIES, to predict the future incoming service requests and their QoS requirements. Our results also show that our FLIES algorithm is able to outperform a standard decentralized learning baseline for predicting incoming requests and show comparable predictive performance when compared to centralized training.

97 MATHEMATICS AND COMPUTING↗

Portsmouth On-Site Disposal Cell (OSDC) High Density Polyethylene (HDPE) Geomembrane Longevity

It is anticipated that high density polyethylene (HDPE) geomembranes will be utilized within the liner and closure cap of the proposed On-Site Disposal Cell (OSDC) at the Portsmouth Gaseous Diffusion Plant. The likely longevity (i.e. service life) of HDPE geomembranes in OSDC service is evaluated within the following sections of this report: (1) Section 2.0 provides an overview of HDPE geomembranes, (2) Section 3.0 outlines potential HDPE geomembranes degradation mechanisms, (3) Section 4.0 evaluates the applicability of HDPE geomembrane degradation mechanisms to the Portsmouth OSDC, (4) Section 5.0 provides a discussion of the current state of knowledge relative to the longevity (service life) of HDPE geomembranes, including the relation of this knowledge to the Portsmouth OSDC, and (5) Section 6.0 provides summary and conclusions relative to the anticipated service life of HDPE geomembranes in OSDC service. Based upon this evaluation it is anticipated that the service life of HDPE geomembranes in OSDC service would be significantly greater than the 200 year service life assumed for the OSDC closure cap and liner HDPE geomembranes. That is, a 200 year OSDC HDPE geomembrane service life is considered a conservative assumption.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Is bigger better? An empirical analysis of waste management in New South Wales

Highlights: • We search for the most efficient cost structure for NSW household waste services. • We found that larger services are no longer efficient. • We found an optimal size for the range 12,000–20,000 inhabitants. • We found significant economies of output density for household waste collection. • We found economies of scope in joint provision of unsorted and recycling services. - Abstract: Across the world, rising demand for municipal solid waste services has seen an ongoing increase in the costs of providing these services. Moreover, municipal waste services have typically been provided through natural or legal monopolies, where few incentives exist to reduce costs. It is thus vital to examine empirically the cost structure of these services in order to develop effective public policies which can make these services more cost efficient. Accordingly, this paper considers economies of size and economies of output density in the municipal waste collection sector in the New South Wales (NSW) local government system in an effort to identify the optimal size of utilities from the perspective of cost efficiency. Our results show that – as presently constituted – NSW municipal waste services are not efficient in terms of costs, thereby demonstrating that ‘bigger is not better.’ The optimal size of waste utilities is estimated to fall in the range 12,000–20,000 inhabitants. However, significant economies of output density for unsorted (residual) municipal waste collection and recycling waste collection were found, which means it is advantageous to increase the amount of waste collected, but maintaining constant the number of customers and the intervention area.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CLARA: A Contemporary Approach to Physics Data Processing

In traditional physics data processing (PDP) systems, data location is static and is accessed by analysis applications. In comparison, CLARA (CLAS12 Reconstruction and Analysis framework) is an environment where data processing algorithms filter continuously flowing data. In CLARA's domain of loosely coupled services, data is not stored, but rather flows from one service to another, mutating constantly along the way. Agents, performing event processing, can then subscribe to particular data/events at any stage of the data transformation, and make intricate decisions (e.g. particle ID) by correlating events from multiple, parallel data streams and/or services. This paper presents a PDP application development framework based on service oriented and event driven architectures. This system allows users to design (Java, C++, and Python languages are supported) and deploy data processing services, as well as dynamically compose PDP applications using available services. The PDP service bus provides a layer on top of a distributed pub-sub middleware implementation, which allows complex service composition and integration without writing code. Examples of service creation and deployment, along with the CLAS12 track reconstruction application design will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Port of Los Angeles Zero- and Near-Zero-Emission Freight Facilities Shore to Store Project

The City of Los Angeles Harbor Department (Harbor Department, Port of Los Angeles) partnered with Equilon Enterprises LLC (d/b/a Shell Oil Products US) (Shell), Toyota Motor North America (Toyota), and Kenworth Truck Company (Kenworth) partnered with the Port of Hueneme, United Parcel Service, Total Transportation Services Inc., Southern Counties Express, Toyota Logistics Services, Air Liquide, National Renewable Energy Laboratory, Coalition For A Safe Environment, and the South Coast Air Quality Management District to introduce hydrogen fuel into the Southern California drayage truck market by demonstrating near-commercial heavy-duty hydrogen fuel cell electric trucks at and between freight facilities throughout the region, while continuing to lay the groundwork for battery-electric operations. The Shore to Store project built on project team experience to help realize our vision of zero-emission freight operations in the future. Ten Kenworth zero-emission Class 8 fuel cell electric trucks, integrated with Toyota’s fuel cell drive technology, were operated by United Parcel Service, Total Transportation Services Inc., Southern Counties Express, and Toyota Logistics Services in commercial service. The demonstration fleet fueled at the Shore to Store hydrogen fueling stations that were built in Ontario, California, and Wilmington, California. An additional station at the Port of Long Beach (Portal Station) was available for fueling the fleet. Portal Station was supported by grants from the California Energy Commission and South Coast Air Quality Management District and used as match funding for the Shore to Store project. The Port of Hueneme demonstrated two battery-electric yard tractors, and Toyota Logistics Services demonstrated two zero-emission forklifts at their warehouse facility, showcasing elements of the entire supply chain operating with zero emissions. This project showcased a snapshot of the zero-emission supply chain of the future, providing a model by which freight facilities can support zero-emission operations. The Shore to Store project: Demonstrated the technical feasibility of zero-emission hydrogen fueled Class 8 heavy-duty trucks and electric cargo handling equipment in rigorous goods movement operation throughout the Southern California region. Cumulatively completed 59,212 miles of zero-emission operation, with 21,650 miles driven in-service with the fleets, using hydrogen fuel cell electric Class 8 heavy-duty trucks. Operated zero-emission yard tractors for a total of 2,749.6 hours. Created direct localized emission reductions in designated disadvantaged communities, including those in zip codes 90220, 90247, 90248, 90731, 90744, 90802, and 91761. For the 59,212 miles of zero-emission operation, reduced emissions by an estimated total of 15.5 kg NOX (0.163 g/km), 1.01 kg SOX (0.0106 g/km), and 304.8 metric tonnes of CO2e (3.2 kg/km) compared to diesel baseline vehicles including both tailpipe emissions and the emissions from producing the fuel sources.

08 HYDROGEN↗

The ABCs of On-Demand Transit (ODT)

On-demand mobility - also referred to as on-demand transit (ODT) - is a form of public mobility that is flexible with respect to where and when service is provided, and ODT deployments have increased significantly in recent years. Transit agencies are becoming increasingly interested in ODT, and due to differing definitions and various service design and business model options, it can be difficult to learn about the emerging industry. This work provides an overview of the definitions of ODT, recent trends internationally and in the U.S., ODT's benefits and challenges (particularly compared to fixed-route transit), three primary service design options, system costs and funding considerations, and a metrics framework for evaluating ODT systems to ensure continued successful performance. Identified benefits include increased service areas, short ride and wait times, increased user flexibility, potential to reduce energy consumption and emissions through shared trips and smaller, right-sized vehicles, increased safety and comfort through door-to-door service, and rich data streams including granular spatio-temporal data that can be analyzed to continuously improve the service. Challenges include scaling ODT service up as small increases in ridership require additional supply to keep service quality high, serving peak times including keeping low wait times, the lack of fixed schedule being challenging for commuters, integrating ODT services with nearby transit systems, and equity for riders without smartphones who cannot track the vehicle in a mobile app. Finally, an overview of seven ODT case studies (in Texas, Missouri, New York, and Ontario, Canada) performed by NREL and related analysis of travel time, energy and emissions, costs, and equity are presented. Initial key findings include: ODT can be cost- and energy-effective compared to fixed-route transit, ODT serves more people than other transit options, and ODT system deployments can be followed by rapid growth.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an end state vision to implement digital monitoring in nuclear plants

Transitioning from an onsite Maintenance & Diagnostics Center to cloud-based services offers many new opportunities with computing power and storage, but also new challenges in terms of networking and security. This report will cover everything required for that transition including data processing and uploading to cloud services, feature selection, model creation, and result visualization for decision making. Although there are several other cloud-based services (e.g. Amazon Web Services and Google Cloud), this report explores Microsoft Azure to simplify nomenclature and maintain a consistent focus. Many of the services offered by Microsoft Azure are also available in the other cloud-based services, and their differences have been recorded in other literature. The Azure services most important to a nuclear power plant including networking & security, storage & databases, and Artificial Intelligence (AI) are reviewed here. Networking covers all aspects related to communication to Azure resources including security, privacy, and redundancy. Storage & databases includes data storage, upgrading, patching, backups, and monitoring. The AI services allows the user access to the machine learning (ML) techniques developed with Azure including automated ML, anomaly detection, computer vision, and natural language processing. This report summaries the features, capabilities, and challenges when using cloud-based services in a user-friendly manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding and Modeling Pooled Rideshare Acceptance: Influential Factors, Preferred User Experiences, and Implications

Ridesharing allows people to share a vehicle with others traveling in the same direction, which can reduce costs and traffic congestion. Pooled rideshare (PR) services, such as UberX Share and Lyft Shared, offer an economical and environmentally friendly alternative by matching passengers traveling similar routes. However, despite these benefits, PR adoption remains low due to concerns about safety, privacy, and convenience. This research explores the factors influencing PR adoption and provides recommendations to improve user acceptance. A nationwide survey of 5,385 participants across the U.S. was conducted to understand why people choose or avoid PR. The study identified five key factors influencing PR consideration: safety, service experience, privacy, traffic/environment, and time/cost. Additional research examined ways to optimize PR experiences by identifying four critical factors: comfort/ease of use, convenience, vehicle technology/accessibility, and passenger safety. To measure the impact of these factors, a statistical model called the Pooled Rideshare Acceptance Model (PRAM) was developed, providing insights into how each element influences PR adoption. Further analysis using the Pooled Rideshare Acceptance Model Multigroup Analyses (PRAMMA) revealed how demographic characteristics such as age, gender, income, and past rideshare experience shape PR perceptions. Some key findings from the multigroup analyses showed that younger users valued technological features and environmental benefits, while older users prioritized reliability and service transparency. Additionally, privacy concerns were more significant for female users, while convenience was critical for higher-income groups. These results emphasize that a 'onesize-fits-all' approach to PR service design is not effective, highlighting the need for tailored strategies to address different user segments. Further, workshops were conducted with researchers and students to translate the findings into real-world solutions. These workshops and 3 all the statistical analyses led to the development of 95 actionable recommendations. The recommendations focus on key areas such as safety, service reliability, user education, and accessibility, offering tangible improvements to PR services. The insights from this study provide valuable guidance for policymakers, transportation network companies (TNCs), and researchers aiming to make PR services safer, more accessible, and widely accepted. By addressing user concerns, PR can become a more viable transportation option, supporting sustainable urban mobility and reducing reliance on private vehicles. Additionally, these findings emphasize the importance of user-centric service design in encouraging broader PR adoption. Future research should explore evolving trends in PR preferences, technological advancements, and policy changes to ensure continued improvements. By implementing these recommendations, PR services can better align with user expectations, enhance trust in shared mobility, and contribute to a more efficient transportation ecosystem.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Doing Your Science While You're in Orbit

Abstract. Large-scale neutron facilities such as the Spallation Neutron Source (SNS) located at Oak Ridge National Laboratory need easy-to-use access to Department of Energy Leadership Computing Facilities and experiment repository data. The Orbiter thick- and thinclient and its supporting Service Oriented Architecture (SOA) based services (available at https://nucleus.sns.gov) consist of standards-based components that are reusable and extensible for accessing high performance computing, data and computational grid infrastructure, and cluster-based resources easily from a user configurable interface. The primary Orbiter system goals consist of (1) developing infrastructure for the creation and automation of virtual instrumentation experiment optimization, (2) developing user interfaces for thin- and thickclient access, (3) provide a prototype incorporating major instrument simulation packages, and (4) facilitate neutron science community access and collaboration. The secure Orbiter SOA authentication and authorization is achieved through the developed Virtual File System (VFS) services, which use Role-Based Access Control (RBAC) for data repository file access, thinand thick-client functionality and application access, and computational job workflow management. The VFS Relational Database Management System (RDMS) consists of approximately 43 database tables describing 429 user accounts with 437 groups over 451,000 directories with 739,618 repository files. Over 39 million NeXus file metadata records are associated to the 12,794 unique NeXus file field/class names generated from the 42,894 repository NeXus files. Services that enable (a) summary dashboards of data repository status with Quality of Service (QoS) metrics, (b) data repository NeXus file field/class name full text search capabilities within a Google like interface, (c) fully functional RBAC browser for the read-only data repository and shared areas, (d) user/group defined and shared metadata for data repository files, (e) user, group, repository, and web 2.0 based global positioning with additional service capabilities are currently available. The SNS based Orbiter SOA integration progress with the Distributed Data Analysis for Neutron Scattering Experiments (DANSE) software development project is summarized with an emphasis on DANSE Central Services and the Virtual Neutron Facility (VNF). Additionally, the DANSE utilization of the Orbiter SOA authentication, authorization, and data transfer services best practice implementations are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling and Evaluation of Cyber-Attacks on Grid-Interactive Efficient Buildings

Grid-interactive efficient buildings (GEBs) are not only exposed to passive threats (e.g., physical faults) but also active threats such as cyber-attacks launched on the network-based control systems. The impact of cyber-attacks on GEB operation are not yet fully understood, especially as regards the performance of grid services. To quantify the consequences of cyber-attacks on GEBs, this paper proposes a modeling and simulation framework that includes different cyber-attack models and key performance indexes to quantify the performance of GEB operation under cyber-attacks. The framework is numerically demonstrated to model and evaluate cyber-attacks such as data intrusion attacks and Denial-of-Service attacks on a typical medium-sized office building that uses the BACnet/IP protocol for communication networks. Simulation results show that, while different types of attacks could compromise the building systems to different extents, attacks via the remote control of a chiller yield the most significant consequences on a building system’s operation, including both the building service and the grid service. It is also noted that a cyber-attack impacts the building systems during the attack period as well as the post-attack period, which suggests that both periods should be considered to fully evaluate the consequences of a cyber-attack.

Fu, Yanyang↗

Web tools concerning performance analysis and planning support for solar energy plants starting from remotely sensed optical images

We present innovative web tools, developed also in the frame of the FP7 ENDORSE (ENergy DOwnstReam SErvices) project, for the performance analysis and the support in planning of solar energy plants (PV, CSP, CPV). These services are based on the combination between the detailed physical model of each part of the plants and the near real-time satellite remote sensing of incident solar irradiance. Starting from the solar Global Horizontal Irradiance (GHI) data provided by the Monitoring Atmospheric Composition and Climate (GMES-MACC) Core Service and based on the elaboration of Meteosat Second Generation (MSG) satellite optical imagery, the Global Tilted Irradiance (GTI) or the Beam Normal Irradiance (BNI) incident on plant's solar PV panels (or solar receivers for CSP or CPV) is calculated. Combining these parameters with the model of the solar power plant, using also air temperature values, we can assess in near-real-time the daily evolution of the alternate current (AC) power produced by the plant. We are therefore able to compare this satellite-based AC power yield with the actually measured one and, consequently, to readily detect any possible malfunctions and to evaluate the performances of the plant (so-called “Controller” service). Besides, the same method can be applied to satellite-based averaged environmental data (solar irradiance and air temperature) in order to provide a Return on Investment analysis in support to the planning of new solar energy plants (so-called “Planner” service). This method has been successfully applied to three test solar plants (in North, Centre and South Italy respectively) and it has been validated by comparing satellite-based and in-situ measured hourly AC power data for several months in 2013 and 2014. The results show a good accuracy: the overall Normalized Bias (NB) is − 0.41%, the overall Normalized Mean Absolute Error (NMAE) is 4.90%, the Normalized Root Mean Square Error (NRMSE) is 7.66% and the overall Correlation Coefficient (CC) is 0.9538. The maximum value of the Normalized Absolute Error (NAE) is about 30% and occurs for time periods with highly variable meteorological conditions. - Highlights: • We developed an online service (Controller) dedicated to solar energy plants real-time monitoring • We developed an online service (Planner) that supports the planning of new solar energy plants • The services are based on the elaboration of satellite optical imagery in near real-time • The validation with respect to in-situ measured hourly AC power data for three test solar plants shows good accuracy • The maximum value of the Normalized Absolute Error is about 30% and occurs for highly variable meteorological conditions.

14 SOLAR ENERGY↗

Model Evaluation and Hindcasting: An Experiment with an Integrated Assessment Model

Integrated assessment models have been extensively used for analyzing long term energy and greenhouse emissions trajectories and have influenced key policies on this subject. Though admittedly these models are focused on the long term trajectories, how well these models are able to capture historical dynamics is an open question. In a first experiment of its kind, we present a framework for evaluation of such integrated assessment models. We use Global Change Assessment Model for this zero order experiment, and focus on the building sector results for USA. We calibrate the model for 1990 and run it forward up to 2095 in five year time steps. This gives us results for 1995, 2000, 2005 and 2010 which we compare to observed historical data at both fuel level and service level. We focus on bringing out the key insights for the wider process of model evaluation through our experiment with GCAM. We begin with highlighting that creation of an evaluation dataset and identification of key evaluation metric is the foremost challenge in the evaluation process. Our analysis highlights that estimation of functional form of the relationship between energy service demand, which is an unobserved variable, and its drivers is a significant challenge in the absence of adequate historical data for both the dependent and driver variables. Historical data availability for key metrics is a serious limiting factor in the process of evaluation. Interestingly, service level data against which such models need to be evaluated are itself a result of models. Thus for energy services, the best we can do is compare our model results with other model results rather than observed and measured data. We show that long term models, by the nature of their construction, will most likely underestimate the rapid growth in some services observed in a short time span. Also, we learn that modeling saturated energy services like space heating is easier than modeling unsaturated services like space cooling and understanding that how far a service is from its saturation level is a key question which we probably don’t have an answer to. Finally and most importantly, even if long term models partially miss the short term dynamics, the long term insights provides by these models is fairly robust. We conclude by highlighting that our work is the first step in the much wider process of integrated assessment model evaluation and will hence have its own limitations. Future evaluation research work should build upon this zero order experiment for improving our modeling of human and coupled earth systems.

building energy↗