Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Monitoring by Use of Clusters of Sensor-Data Vectors

The inductive monitoring system (IMS) is a system of computer hardware and software for automated monitoring of the performance, operational condition, physical integrity, and other aspects of the health of a complex engineering system (e.g., an industrial process line or a spacecraft). The input to the IMS consists of streams of digitized readings from sensors in the monitored system. The IMS determines the type and amount of any deviation of the monitored system from a nominal or normal ( healthy ) condition on the basis of a comparison between (1) vectors constructed from the incoming sensor data and (2) corresponding vectors in a database of nominal or normal behavior. The term inductive reflects the use of a process reminiscent of traditional mathematical induction to learn about normal operation and build the nominal-condition database. The IMS offers two major advantages over prior computational monitoring systems: The computational burden of the IMS is significantly smaller, and there is no need for abnormal-condition sensor data for training the IMS to recognize abnormal conditions. The figure schematically depicts the relationships among the computational processes effected by the IMS. Training sensor data are gathered during normal operation of the monitored system, detailed computational simulation of operation of the monitored system, or both. The training data are formed into vectors that are used to generate the database. The vectors in the database are clustered into regions that represent normal or nominal operation. Once the database has been generated, the IMS compares the vectors of incoming sensor data with vectors representative of the clusters. The monitored system is deemed to be operating normally or abnormally, depending on whether the vector of incoming sensor data is or is not, respectively, sufficiently close to one of the clusters. For this purpose, a distance between two vectors is calculated by a suitable metric (e.g., Euclidean distance) and "sufficiently close" signifies lying at a distance less than a specified threshold value. It must be emphasized that although the IMS is intended to detect off-nominal or abnormal performance or health, it is not necessarily capable of performing a thorough or detailed diagnosis. Limited diagnostic information may be available under some circumstances. For example, the distance of a vector of incoming sensor data from the nearest cluster could serve as an indication of the severity of a malfunction. The identity of the nearest cluster may be a clue as to the identity of the malfunctioning component or subsystem. It is possible to decrease the IMS computation time by use of a combination of cluster-indexing and -retrieval methods. For example, in one method, the distances between each cluster and two or more reference vectors can be used for the purpose of indexing and retrieval. The clusters are sorted into a list according to these distance values, typically in ascending order of distance. When a set of input data arrives and is to be tested, the data are first arranged as an ordered set (that is, a vector). The distances from the input vector to the reference points are computed. The search of clusters from the list can then be limited to those clusters lying within a certain distance range from the input vector; the computation time is reduced by not searching the clusters at a greater distance.

Iverson, David L.↗

Ion-beam irradiation of lanthanum compounds in the systems La{sub 2}O{sub 3}-Al{sub 2}O{sub 3} and La{sub 2}O{sub 3}-TiO{sub 2}

Thin crystals of La{sub 2}O{sub 3}, LaAlO{sub 3}, La{sub 2/3}TiO{sub 3}, La{sub 2}TiO{sub 5}, and La{sub 2}Ti{sub 2}O{sub 7} have been irradiated in situ using 1 MeV Kr{sup 2+} ions at the Intermediate Voltage Electron Microscope-Tandem User Facility (IVEM-Tandem), Argonne National Laboratory (ANL). We observed that La{sub 2}O{sub 3} remained crystalline to a fluence greater than 3.1x10{sup 16} ions cm{sup -2} at a temperature of 50 K. The four binary oxide compounds in the two systems were observed through the crystalline-amorphous transition as a function of ion fluence and temperature. Results from the ion irradiations give critical temperatures for amorphisation (T{sub c}) of 647 K for LaAlO{sub 3}, 840 K for La{sub 2}Ti{sub 2}O{sub 7}, 865 K for La{sub 2/3}TiO{sub 3}, and 1027 K for La{sub 2}TiO{sub 5}. The T{sub c} values observed in this study, together with previous data for Al{sub 2}O{sub 3} and TiO{sub 2}, are discussed with reference to the melting points for the La{sub 2}O{sub 3}-Al{sub 2}O{sub 3} and La{sub 2}O{sub 3}-TiO{sub 2} systems and the different local environments within the four crystal structures. Results suggest that there is an observable inverse correlation between T{sub c} and melting temperature (T{sub m}) in the two systems. More complex relationships exist between T{sub c} and crystal structure, with the stoichiometric perovskite LaAlO{sub 3} being the most resistant to amorphisation. - Graphical abstract: La{sub 2}TiO{sub 5} with atypical co-ordination for Ti, TiO{sub 5} is found to be different in radiation resistance to La{sub 2}Ti{sub 2}O{sub 7} and La{sub 2/3}TiO{sub 3}. Irradiation of La-Ti-O, and La-Al-O based systems has found that radiation damage resistance is related to the ability of the system to disorder.

36 MATERIALS SCIENCE↗

Earth Observing-1 Advanced Land Imager Flight Performance Assessment: Absolute Radiometry and Stability During the First Year

The absolute radiometry of the Advanced Land Imager during the first year on orbit (November 21,2000 - November 21, 2001) is presented. Results derived from solar, lunar, ground truth, and internal reference lamp measurements are presented. An 18% drop in the radiometric response of the Band 1p data since preflight calibration at Lincoln Laboratory is observed using all techniques. This decrease cannot be accounted for by preflight calibration errors, stray light, or contamination of the focal plane. A slight drooping of the VNIR response toward the blue and a 5-12% increase in the Band 5 response is also apparent in all the data. Radiometric response correction factors have been calculated and preflight calibration coefficients have been updated in order to provide +/- 5% agreement between the measured solar, lunar, and ground truth data and the expected values. The radiometric stability of the ALI during the first year of operation is also presented for each spectral band. Internal reference lamp data indicate the focal plane has been stable to within 1% for bands 1p, 1, 2, 5p, 5, 7, pan and 3% for Bands 3,4, 4p since launch. Solar, lunar, and ground truth measurements indicate the optical train and solar diffuser of the instrument has been stable to within 1% since initial measurements on orbit in late December 2000.

Mendenhall, J. A.↗

INTERGALACTIC MAGNETIC FIELD AND ARRIVAL DIRECTION OF ULTRA-HIGH-ENERGY PROTONS

We studied how the intergalactic magnetic field (IGMF) affects the propagation of super-Greisen-Zatsepin-Kuz'min (GZK) protons that originate from extragalactic sources within the local GZK sphere. To this end, we set up hypothetical sources of ultra-high-energy cosmic rays (UHECRs), virtual observers, and the magnetized cosmic web in a model universe constructed from cosmological structure formation simulations. We then arranged a set of reference objects mimicking active galactic nuclei (AGNs) in the local universe, with which correlations of simulated UHECR events are analyzed. With our model IGMF, the deflection angle between the arrival direction of super-GZK protons and the sky position of their actual sources is quite large with a mean value of (theta) {approx} 15 deg. and a median value of THETA-tilde{approx}7 deg. - 10 deg. On the other hand, the separation angle between the arrival direction and the sky position of nearest reference objects is substantially smaller with (S) {approx} 3.{sup 0}5-4{sup 0}, which is similar to the mean angular distance in the sky to nearest neighbors among the reference objects. This is a direct consequence of our model that the sources, observers, reference objects, and the IGMF all trace the matter distribution of the universe. The result implies that extragalactic objects lying closest to the arrival direction of UHECRs are not necessarily their actual sources. With our model for the distribution of reference objects, the fraction of super-GZK proton events, whose closest AGNs are true sources, is less than 1/3. We discussed implications of our findings for correlation studies of real UHECR events.

79 ASTRONOMY AND ASTROPHYSICS↗

Methodology for Generating Conflict Scenarios by Time Shifting Recorded Traffic Data

A methodology is presented for generating conflict scenarios that can be used as test cases to estimate the operational performance of a conflict probe. Recorded air traffic data is time shifted to create traffic scenarios featuring conflicts with characteristic properties similar to those encountered in typical air traffic operations. First, a reference set of conflicts is obtained from trajectories that are computed using birth points and nominal flight plans extracted from recorded traffic data. Distributions are obtained for several primary properties (e.g., encounter angle) that are most likely to affect the performance of a conflict probe. A genetic algorithm is then utilized to determine the values of time shifts for the recorded track data so that the primary properties of conflicts generated by the time shifted data match those of the reference set. This methodology is successfully demonstrated using recorded traffic data for the Memphis Air Route Traffic Control Center; a key result is that the required time shifts are less than 5 min for 99% of the tracks. It is also observed that close matching of the primary properties used in this study additionally provides a good match for some other secondary properties.

Paglione, Mike↗

Comparison of Target Registration Errors for Multiple Image-Guided Techniques in Accelerated Partial Breast Irradiation

Purpose: External beam accelerated partial breast irradiation requires accurate localization of the target volume for each treatment fraction. Using the concept of target registration error (TRE), the performance of several methods of target localization was compared. Methods and Materials: Twelve patients who underwent external beam accelerated partial breast irradiation were included in this study. TRE was quantified for four methods of image guidance: standard laser-based setup, kilovoltage imaging of the chest wall, kilovoltage imaging of surgically implanted clips, and three-dimensional surface imaging of the breast. The use of a reference surface created from a free-breathing computed tomography scan and a reference surface directly captured with three-dimensional video imaging were compared. The effects of respiratory motion were also considered, and gating was used for 8 of 12 patients. Results: The median value of the TRE for the laser, chest wall, and clip alignment was 7.1 mm (n = 94), 5.4 mm (n = 81), and 2.4 mm (n = 93), respectively. The median TRE for gated surface imaging based on the first fraction reference surface was 3.2 mm (n = 49), and the TRE for gated surface imaging using the computed tomography-based reference surface was 4.9 mm (n = 56). The TRE for nongated surface imaging using the first fraction reference surface was 6.2 mm (n = 25). Conclusions: The TRE of surface imaging using a reference surface directly captured with three-dimensional video and the TRE for clip-based setup were within 1 mm. Gated capture is important for surface imaging to reduce the effects of respiratory motion in accelerated partial breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of satellite servicing cost benefits

Under the auspices of NASA/JSC a methodology was developed to estimate the value of satellite servicing to the user community. Time and funding precluded the development of an exhaustive computer model; instead, the concept of Design Reference Missions was involved. In this approach, three space programs were analyzed for various levels of servicing. The programs selected fall into broad categories which include 80 to 90% of the missions planned between now and the end of the century. Of necessity, the extrapolation of the three program analyses to the user community as a whole depends on an average mission model and equivalency projections. The value of the estimated cost benefits based on this approach depends largely on how well the equivalency assumptions and the mission model match the real world. A careful definition of all assumptions permits the analysis to be extended to conditions beyond the scope of this study.

Builteman, H. O.↗

The Uranium-Containing and Thorium-Containing Anions Studied by Photoelectron Spectroscopy

An in-depth knowledge of actinide chemistry is fundamental to many aspects of nuclear science and technology, including the synthesis and processing of materials and the remediation of waste disposal sites. Among the actinides, the chemical bonding behaviors of actinium and thorium resemble those of the transition metals; the 5f-electrons of protactinium, uranium, neptunium, and plutonium often play important roles in their bonding; and among the still heavier elements, their bonding tends to mimic the lanthanide elements in terms of electron shielding and their f-electron contributions. Bonding that involves 5f-electrons, however, is especially important, in part because of the significance of uranium and plutonium, but also because these elements are among the few where f-electron participation in bonding is relatively common. This work focused on studying uranium-containing and thorium-containing anions in the gas phase using negative ion photoelectron spectroscopy. Since this technique directly probed valence electrons, it was uniquely positioned to address open questions regarding molecular bonding and electron configurations. A particularly important issue concerned how bonding in actinide-containing molecules was affected by modifications to their actinide atoms’ environment, i.e., due to their interaction with ligands. A closely related question was how actinide atoms’ suborbitals were qualitatively reordered and their energies quantitatively shifted as a result of their ligated environments. These were especially relevant issues in regard to uranium due to it having multiple possible oxidation states (OS) and the potential for 5f electron participation in bonding. The effects of ligands on oxidation states and 5f-orbital energies in uranium bonding was expected to be pronounced. Both ligands and excess electrons were seen as probes of actinide atoms within actinide-containing molecules. Our strategy for advancing knowledge of chemical bonding in the actinide-containing species utilized the synergy between experiments and theory, where in some cases experimental results validated theory and where in others computational results assisted in interpreting experiments. Calculations on actinide systems are terrifically challenging due to large spin-orbit interactions, relativistic effects, and just the sheer number of electrons involved. Even in the simplest species, e.g., U and U2, the most sophisticated, modern calculations carried out by the most experienced theorists often only approximate experimentally-measured values, such as electron affinities. For theory to provide confident predictions that can be used to solve real problems it needed an iterative and ultimately corrective mechanism by which its methods can develop further. Experiments can be used to identify when theory has failed; whereupon the subsequent process of using the experiment-theory interplay can be used to find the cause of the failure. Upon fixing it in one case, different test species can be proposed and studied by the experiment-theory combination to determine whether the problem has been corrected. Thus, experiments not only measure the values of molecular properties, they also provide navigational 3 beacons that keep computations off the reefs in an otherwise dark sea with few reference points. Experimental measurements in the actinide field are not only important, they are in actuality essential to computational progress. While it was not always possible to compare the theoreticallydetermined quantity of interest directly with the same experimentally-measured observable, it was usually possible to compare consequential properties that are both calculable and measurable. In the work completed here electron affinities and electronic state spacings were often sensitive consequential parameters. Reasonable agreement between measured and computational values signaled that a calculation that was very likely to be on-track. We had established collaborative relationships with five computational groups, all of which have expertise in computational actinide chemistry. Their PI’s are L. Cheng, D. Dixon, L. Gagliardi, K. Peterson, and B. Vlaisavljevich. Our close interaction with our theory partners led to us suggesting systems to them and them to us. This reciprocal interaction between our experimental and their computational results was among the most important strengths of this work and was a thread woven throughout. Even though anion photoelectron spectroscopic studies are conducted on anions, much of the information that they provide, pertains to the electronic structure of the neutral counterparts of those anions; among these are electron affinities and electronically excited state spacings. Our experimental tools included several specialized ion sources for forming the anionic species of interest, a mass spectrometer for identifying and mass-selecting them, and an anion photoelectron spectrometer for determining their electron affinities (EA) and characterizing the electronic states of the selected anions’ neutral counterparts. Anion photoelectron spectroscopy is conducted by crossing a mass-selected beam of anions with a fixed-frequency laser beam and energy-analyzing the resultant photodetached electrons. The photodetachment process is governed by the energyconserving relationship: hν = EBE + EKE, where hν is the photon’s energy, EBE is the electron binding (photodetachment transition) energy, and EKE is the electron’s kinetic energy. In our apparatus mass-selection is accomplished via time-of-flight mass spectrometry (TOF-MS), electron energy analysis is achieved with either a magnetic bottle or by velocity mapped imaging. Photodetachment of electrons from anions is implemented via either Nd:YAG or excimer lasers. The photodetachment transition energy, i.e., the EBE, between the ground vibrational and electronic state of an anion and the ground vibrational and electronic state of that anion’s neutral counterpart is the adiabatic electron affinity (EA) of that neutral molecule. Likewise, photodetachment transitions between the ground vibrational and electronic state of an anion and the various electronically-excited states of that anion’s corresponding neutral map the electronic spectrum of that neutral species, i.e., the spectral spacings in the photoelectron spectrum are a mirror image of the neutral’s electronic spectrum. It was, of course, crucial to be able to form the anionic species of interest. There, we had a particularly broad field of anion sources from which to choose. These included several variants of pulsed laser vaporization (LV), laser photoemission, infrared desorption plus photoemission, pulsed arc discharge (PACIS), electrospray ionization (ESI), and Rydberg electron transfer (RET). Each of these anion sources were readily combined with, i.e., connected to, the anion photoelectron spectroscopic portion of our apparatus as described above. Among the sources that utilize lasers, visible light for LV sources as well as IR for desorption sources are provided by Nd:YAG lasers. Ultraviolet photons are provided by both Nd:YAG and excimer lasers, whereas the excitation wavelengths for RET experiments come from two Nd:YAG-pumped dye lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of the Solute-Solvent EMF Cell to Measure Activity of NiF 2 in Molten FLiNaK

Electromotive force (emf) measurements made using a combination of solute- and solvent-based electrodes were used to determine the activity of NiF 2 in molten FLiNaK eutectic at 823 K across a concentration range of x NiF2 = 5.2 × 10 –4 –1.0 × 10 –2 . The solute emf values were measured using electrodes consisting of Ni wires immersed in FLiNaK with dissolved NiF 2 contained in graphite crucibles. The measured emf values were then converted to the FLiNaK Eutectic Potassium Electrode (FEKE) potential and used to quantify the activity of dissolved NiF 2 . This quantification was based upon comparative measurements of a reference solvent electrode consisting of a K-Bi alloy immersed in pure FLiNaK contained in a boron nitride crucible and a solute electrode. Short cell lives were characteristic of the measurements due to the corrosive nature of the fluoride salts. Quantifying the activity of NiF 2 will improve the utility of Ni 2+ /Ni reference electrodes in molten fluoride salts, which are notoriously difficult electrolytes to work with because of their reactivity. In conclusion, this work demonstrates the general nature of the solute-solvent approach as a repeatable, easily employed method for measuring the activity values of electroactive species in a variety of molten salts to improve understanding of the electroactive species behavior in these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of PBR Spent Fuel Criticality and Dose Rate Compliance for Storage and Transportation

Spent tri-structural isotropic (TRISO)–based fuels have a strong track record in storage and transportation without documented incidents. This work seeks to reduce uncertainty to aid in more informed spent fuel management of TRISO-based fuels by modeling both fresh and spent pebble bed reactor (PBR) fuel and comparing the results to the regulatory standards from 10 CFR 71. SCALE was used for all modeling due to it having fast and accurate methods for handling PBR fuel modeling, as well as having an efficient method for shielding calculations in monaco with automated variance reduction using importance calculations (MAVRIC), which utilizes the consistent adjoint-driven importance sampling (CADIS) and the forward-weighted consistent adjoint-driven importance sampling (FW-CADIS) methods. KENO-VI was used for all criticality calculations, TSUNAMI was used for uncertainty quantification on k-effective, TRITON and the Oak Ridge isotope generation code (ORIGEN) were both used for depletion of the fuel, and MAVRIC was used for shielding calculations. For criticality assessments, this study focused on the requirement that the value of the neutron multiplication factor, k-effective (k-eff), would not exceed a peak value of 0.95, including uncertainty, with 95% confidence. Criticality was initially examined by modeling fresh fuel from three different designs—HTR-10 fuel, PBMR-400 fuel, and demonstration fuel representative of a TRISO-fueled modern high-temperature gas reactor (HTGR) design, henceforth referred to as Demo HTGR—and placing them into various sized containers with conditions described in 10 CFR 71 to quantify the peak k-eff state. When the peak value of 0.95 k-eff was exceeded, mitigation methods were examined in those scenarios. Burnup credit, pebble displacement in areas of strong neutron multiplication, and random pebble replacement using pebbles of various compositions and replacement fractions were examined. In summary, the criticality of PBR fuels can be well accounted for by restricting container size, taking credit for burnup, or by displacing/replacing pebbles. Uncertainty of the k-eff due to nuclear data uncertainties was recorded at ~0.6644%Δk/k, or roughly 664% mil (pcm). The nuclear data–induced uncertainty was relatively small and should not require significant modification in the design to be accounted for. Revisions to the evaluated nuclear data file values have been shown to have a larger impact than nuclear data–induced uncertainty. For dose rate aspects, U.S. Nuclear Regulatory Commission regulations require a maximum dose rate of 10 millirem per hour (mrem/h) at 2 meters. In examining the dose rate behavior of spent PBR fuel, the representative Demo HTGR fuel was modeled exclusively due to it possessing the highest target burnup of the examined fuels. Equilibrium cycle modeling methods were used to produce a higher-fidelity discharge isotopic composition than simple assumptions, such as reflected pebbles. The discharge composition was used as a source term in the fixed-source transport shielding calculations, and dose rates were calculated at 2 m for the shortest possible cooling time. The low concentration of fuel material led to dose rates that were in line with regulatory limits, despite the high burnup when compared to traditional light water reactor fuels. In conclusion, the methods employed in this study would require more work to further verify and validate and are limited to the criticality and dose rate analyses performed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Orthogonality of embedded wave functions for different states in frozen-density embedding theory

Other than lowest-energy stationary embedded wave functions obtained in Frozen-Density Embedding Theory (FDET) [T. A. Wesolowski, Phys. Rev. A 77, 012504 (2008)] can be associated with electronic excited states but they can be mutually non-orthogonal. Although this does not violate any physical principles — embedded wave functions are only auxiliary objects used to obtain stationary densities — working with orthogonal functions has many practical advantages. In the present work, we show numerically that excitation energies obtained using conventional FDET calculations (allowing for non-orthogonality) can be obtained using embedded wave functions which are strictly orthogonal. The used method preserves the mathematical structure of FDET and self-consistency between energy, embedded wave function, and the embedding potential (they are connected through the Euler-Lagrange equations). The orthogonality is built-in through the linearization in the embedded density of the relevant components of the total energy functional. Moreover, we show formally that the differences between the expectation values of the embedded Hamiltonian are equal to the excitation energies, which is the exact result within linearized FDET. Linearized FDET is shown to be a robust approximation for a large class of reference densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Effects of Real-World Factors on the Recovery and Exploitation of Forensic Impurity Profiles of a Nerve-Agent Simulant from Office Media

Dimethyl methylphosphonate (DMMP) was used as a chemical threat agent (CTA) simulant for a first look at the effects of real-world factors on the recovery and exploitation of a CTA’s impurity profile for source matching. Four stocks of DMMP having different impurity profiles were disseminated as aerosols onto cotton, painted wall board, and nylon coupons according to a thorough experimental design. The DMMP-exposed coupons were then solvent extracted and analyzed for DMMP impurities by comprehensive 2-D gas chromatography/mass spectrometry (GC×GC/MS). The similarities between the coupon DMMP impurity profiles and the known (reference) DMMP profiles were measured by dot products of the coupon profiles and known profiles and by score values obtained from principal component analysis. One stock, with a high impurity-profile selectivity value of 0.9 out of 1, had 100% of its respective coupons correctly classified and no false positives from other coupons. Coupons from the other three stocks with low selectivity values (0.0073, 0.012, and 0.018) could not be sufficiently distinguished from one another for reliable matching to their respective stocks. The results from this work support that: (1) extraction solvents, if not appropriately selected, can have some of the same impurities present in a CTA reducing a CTA’s useable impurity profile, (2) low selectivity among a CTA’s known impurity profiles will likely make definitive source matching impossible in some real-world conditions, (3) no detrimental chemical-matrix interference was encountered during the analysis of actual office media, (4) a short elapsed time between release and sample storage is advantageous for the recovery of the impurity profile because it minimizes volatilization of forensic impurities, and (5) forensic impurity profiles weighted towards higher volatility impurities are more likely to be altered by volatilization following CTA exposure.

Chemical forensics↗

Molecular electric moments calculated by using natural orbital functional theory

The molecular electric dipole, quadrupole, and octupole moments of a selected set of 21 spin-compensated molecules are determined employing the extended version of the Piris natural orbital functional 6 (PNOF6), using the triple-ζ Gaussian basis set with polarization functions developed by Sadlej, at the experimental geometries. The performance of the PNOF6 is established by carrying out a statistical analysis of the mean absolute errors with respect to the experiment. The calculated PNOF6 electric moments agree satisfactorily with the corresponding experimental data and are in good agreement with the values obtained by accurate ab initio methods, namely, the coupled-cluster single and doubles and multi-reference single and double excitation configuration interaction methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The AME2016 atomic mass evaluation (I). Evaluation of input data; and adjustment procedures

This paper is the first of two articles (Part I and Part II) that presents the results of the new atomic mass evaluation, Ame2016. It includes complete information on the experimental input data (also including unused and rejected ones), as well as details on the evaluation procedures used to derive the tables of recommended values given in the second part. This article describes the evaluation philosophy and procedures that were implemented in the selection of specific nuclear reaction, decay and mass-spectrometric results. These input values were entered in the least-squares adjustment for determining the best values for the atomic masses and their uncertainties. Details of the calculation and particularities of the Ame are then described. All accepted and rejected data, including outweighted ones, are presented in a tabular format and compared with the adjusted values obtained using the least-squares fit analysis. Differences with the previous Ame2012 evaluation are discussed and specific information is presented for several cases that may be of interest to Ame users. The second Ame2016 article gives a table with the recommended values of atomic masses, as well as tables and graphs of derived quantities, along with the list of references used in both the Ame2016 and the Nubase2016 evaluations (the first paper in this issue). Amdc: http://amdc.impcas.ac.cn/

Ame↗

The first two chromosome‐scale genome assemblies of American hazelnut enable comparative genomic analysis of the genus Corylus

Summary The native, perennial shrub American hazelnut ( Corylus americana ) is cultivated in the Midwestern United States for its significant ecological benefits, as well as its high‐value nut crop. Implementation of modern breeding methods and quantitative genetic analyses of C. americana requires high‐quality reference genomes, a resource that is currently lacking. We therefore developed the first chromosome‐scale assemblies for this species using the accessions ‘Rush’ and ‘Winkler’. Genomes were assembled using HiFi PacBio reads and Arima Hi‐C data, and Oxford Nanopore reads and a high‐density genetic map were used to perform error correction. N50 scores are 31.9 Mb and 35.3 Mb, with 90.2% and 97.1% of the total genome assembled into the 11 pseudomolecules, for ‘Rush’ and ‘Winkler’, respectively. Gene prediction was performed using custom RNAseq libraries and protein homology data. ‘Rush’ has a BUSCO score of 99.0 for its assembly and 99.0 for its annotation, while ‘Winkler’ had corresponding scores of 96.9 and 96.5, indicating high‐quality assemblies. These two independent assemblies enable unbiased assessment of structural variation within C. americana , as well as patterns of syntenic relationships across the Corylus genus. Furthermore, we identified high‐density SNP marker sets from genotyping‐by‐sequencing data using 1343 C. americana , C. avellana and C. americana × C. avellana hybrids, in order to assess population structure in natural and breeding populations. Finally, the transcriptomes of these assemblies, as well as several other recently published Corylus genomes, were utilized to perform phylogenetic analysis of sporophytic self‐incompatibility (SSI) in hazelnut, providing evidence of unique molecular pathways governing self‐incompatibility in Corylus .

54 ENVIRONMENTAL SCIENCES↗

An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers in kilovoltage x rays

For ion chambers with cavities open to the surrounding atmosphere, the response measured at a given temperature and pressure must be corrected using the standard temperature-pressure correction factor (P{sub TP}). A previous paper based solely on Monte Carlo simulations [D. J. La Russa and D. W. O. Rogers, Med. Phys. 33, 4590-4599 (2006)] pointed out the shortcomings of the P{sub TP} correction factor when used to correct the response of non-air-equivalent chambers for low-energy x-ray beams. This work presents the results of several experiments that corroborate these calculations for a number of ion chambers. Monte Carlo simulations of the experimental setup revealed additional insight into the various factors affecting the extent of the breakdown of P{sub TP}, including the effect of impurities and the sensitivity to chamber dimensions. For an unfiltered 60 kV beam, the P{sub TP}-corrected response of an NE 2571 ion chamber measured at 0.7 atm was 2.5% below the response measured at reference conditions. In general, Monte Carlo simulations of the experimental setup using EGSnrc were within 0.5% of measured values. EGSnrc-calculated values of air kerma calibration coefficients (N{sub K}) at low x-ray energies are also provided as a means of estimating the level of impurities in the chambers investigated. Calculated values of N{sub K} normalized to the value measured for a 250 kV beam were obtained for three chambers and were within 1% of experiment with one exception, the Exradin A12 in a 50 kV beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

A parameterization method and application in breast tomosynthesis dosimetry

Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized using a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA protocol and in the UK, European, and IAEA dosimetry protocols. Microsoft Excel™ spreadsheets are provided for the convenience of readers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study

Purpose: Wall thickness (WT) is an airway feature of great interest for the assessment of morphological changes in the lung parenchyma. Multidetector computed tomography (MDCT) has recently been used to evaluate airway WT, but the potential risk of radiation-induced carcinogenesis—particularly in younger patients—might limit a wider use of this imaging method in clinical practice. The recent commercial implementation of the statistical model-based iterative reconstruction (MBIR) algorithm, instead of the conventional filtered back projection (FBP) algorithm, has enabled considerable radiation dose reduction in many other clinical applications of MDCT. The purpose of this work was to study the impact of radiation dose and MBIR in the MDCT assessment of airway WT. Methods: An airway phantom was scanned using a clinical MDCT system (Discovery CT750 HD, GE Healthcare) at 4 kV levels and 5 mAs levels. Both FBP and a commercial implementation of MBIR (Veo{sup TM}, GE Healthcare) were used to reconstruct CT images of the airways. For each kV–mAs combination and each reconstruction algorithm, the contrast-to-noise ratio (CNR) of the airways was measured, and the WT of each airway was measured and compared with the nominal value; the relative bias and the angular standard deviation in the measured WT were calculated. For each airway and reconstruction algorithm, the overall performance of WT quantification across all of the 20 kV–mAs combinations was quantified by the sum of squares (SSQs) of the difference between the measured and nominal WT values. Finally, the particular kV–mAs combination and reconstruction algorithm that minimized radiation dose while still achieving a reference WT quantification accuracy level was chosen as the optimal acquisition and reconstruction settings. Results: The wall thicknesses of seven airways of different sizes were analyzed in the study. Compared with FBP, MBIR improved the CNR of the airways, particularly at low radiation dose levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%–96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV–mAs selection resulted in a radiation dose reduction of 37%–83% compared with a reference scan protocol with a dose level of 1 mGy. Conclusions: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation.

60 APPLIED LIFE SCIENCES↗