Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Frame”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Pressure-induced phase matching in high-order harmonic generation

We present an alternative explanation of the high-order-harmonic-generation experimental results published recently by Seres et al. [Nature Phys. 6, 455 (2010)]. We show that the physical interpretation can be comprehensively done in the frame of classical theory of high-order harmonic generation without referring to a parametric effect in the XUV domain. The experimental conditions explored by Seres et al. indeed correspond to the case of long-pulse, low-infrared-energy laser beams for which tight focusing is necessary to reach the minimum intensity required for high atomic response. The positive atomic dispersion can compensate for the Gouy phase and explains the behavior of the experimental variation of the harmonic signal presented. We will show that our interpretation explains not only the global behavior of the curves but also the second-order variation of the signal as a function of experimental parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

5.1.6 Demo #6: NanoStitch (NAWAStitch) Multifunctional Composites Trade Validation

The overall objective of the NanoStitch Multifunctional Composites Trade Validation Demonstration project was to determine the value proposition of adding NanoStitch to rapid-cure composite systems for structures used in the expanding sector of advanced air mobility (AAM) and specifically electric vertical take-off and landing (eVTOL) aircraft. The expected value proposition was stronger composite parts, with new multifunctional attributes, that are lower cost to fabricate and maintain. NanoStitch is a new composite innovation where a contiguous vertically aligned carbon nanotube (VACNT) forest is located between each ply of a laminate composite resulting in improved mechanical properties as well as other multifunctional properties such as enhanced thermal and electrical conductivity. NanoStitch was originally distributed by N12, later acquired by NAWA Technologies, now called NAWAStitch, and henceforth referred to in this document as NAWAStitch. Two significant evaluations were framed to help meet the overall objective. First, was Task 1 to evaluate the effects that adding NAWAStitch to a rapid cure material system would have on the mechanical and processing properties of the material. Second, was Task 2 to evaluate the workability of adding NAWAStitch to practical flight demonstration articles. From previous research, it was already known that the application of NAWAStitch to a composite structure can enhance the mechanical properties of that structure. However, this project will help the engineering community understand those benefits and the basic structural strength values to apply when incorporating NAWAStitch material into composite structure that utilizes a rapid-cure resin system, which is novel. Testing showed that by adding NAWAStitch to the prepreg, most material properties were improved because the VACNTs strengthened the resin to fiber interface, and the interface itself, between plies. For example compression strength improved by more than 20%, and erosion resistance by more than 50%. The UDRI team identified two flight demonstration articles through discussions with Aurora Flight Sciences (Aurora) and reviewing literature on air mobility and the eVTOL market. The demonstration articles were a thin skin honeycomb panel and a section from an eVTOL propeller blade. The manufacturing and testing trials of the demonstration articles were as follows: • NAWAStitch added no manufacturing complexity or detriment to the article physical qualities, while at the same time added multifunctional properties such as enhanced rain erosion and electrothermal de-icing besides enhanced mechanical properties • VACNTs did not increase or hurt the mechanical properties of the interface between honeycomb core materials and the thin skin face sheet • Demonstrated successful de-icing function in an eVTOL propeller meeting real-world specifications in uniformity and endurance • Multifunctional eVTOL propeller cost analysis showed a cost savings of at least 67 % for a single propeller blade with multifunctional de-icing capability and improved mechanical properties which equates to a potential savings of $10,116 per eVTOL aircraft with six three-bladed propellers Overall, the results of this project can provide additional tools for the composite industry to optimize energy efficiency through faster and stronger composite parts that are lower cost to fabricate and maintain. Additionally, the results of this effort can help US industry like NAWA America set the stage for rapid growth and establishment of a manufacturing facility in Ohio. The project has given NAWA America the basic understanding of how the addition of VACNTs to a composite structure can affect the mechanical properties and hence point them to potential commercial applications. The project has also provided Teijin Carbon US with another potential material application for their rapid cure materials that are manufactured at the Renegade facility in Miamisburg, OH.

36 MATERIALS SCIENCE↗

The Solar Spectral Irradiance as a Function of the Mg II Index for Atmosphere and Climate Modelling

In this paper we present a new method to reconstruct the solar spectrum irradiance in the Ly alpha-400 nm region, and its variability, based on the Mg II index and neutron monitor. Measurements of the solar spectral irradiance available in the literature have been made with different instruments at different times and different spectral ranges. However, climate studies require harmonized data sets. This new approach has the advantage of being independent of the absolute calibration and aging of the instruments. First, the Mg II index is derived using solar spectra from Ly alpha (121 nm) to 410 nm measured from 1978 to 2010 by several space missions. The variability of the spectra with respect to a chosen reference spectrum as a function of time and wavelength is scaled to the derived Mg II index. The set of coefficients expressing the spectral variability can be applied to the chosen reference spectrum to reconstruct the solar spectra within a given time frame or Mg II index values. The accuracy of this method is estimated using two approaches: by direct comparison with particular cases where solar spectra are available from independent measurements, and by calculating the standard deviation between the measured spectra and their reconstruction. From direct comparisons with measurements we obtain an accuracy of about 1 to 2 %, which degrades towards Ly alpha. In a further step, we extend our solar spectral irradiance reconstruction back to the Maunder Minimum introducing the relationship between the Mg II index and the neutron monitor data. Consistent measurements of the Mg II index are not available prior to 1978. However, we observe that over the last three solar cycles, the Mg II index shows strong correlation with the modulation potential determined from the neutron monitor data. Assuming that this correlation can be applied to the past, we reconstruct the Mg II index from the modulation potential back to the Maunder Minimum, and obtain the corresponding solar spectral irradiance reconstruction back to that period. As there is no direct measurement of the spectral irradiance for this period we discuss this methodology in light of the other proposed approaches available in the literature. The use of the cosmogenic isotope data provides a major advantage: it provides information about the solar activity over several thousands years. Using technology of today we can calibrate the solar irradiance against the activity and thus reconstruct it for the times when cosmogenic isotope data are available. This calibration can be re-accessed at any time, if necessary.

Thuillier, Gerard↗

The Kepler Full Frame Images

NASA's exoplanet discovery mission Kepler provides uninterrupted 1-min and 30-min optical photometry of a 100 square degree field over a 3.5 yr nominal mission. Downlink bandwidth is filled at these short cadences by selecting only detector pixels specific to 105 preselected stellar targets. The majority of the Kepler field, comprising 4 x 10(exp 6) m_v < 20 sources, is sampled at much lower 1-month cadence in the form of a full-frame image. The Full Frame Images (FFIs) are calibrated by the Science Operations Center at NASA Ames Research Center. The Kepler Team employ these images for astrometric and photometric reference but make the images available to the astrophysics community through the Multimission Archive at STScI (MAST). The full-frame images provide a resource for potential Kepler Guest Observers to select targets and plan observing proposals, while also providing a freely-available long-cadence legacy of photometric variation across a swathe of the Galactic disk.

Dotson, Jessie L.↗

PRISMA: PARALLEL REFINEMENT AND INTEGRATION SYSTEM FOR MULTI-AZIMUTHAL ANALYSIS

The Parallel Refinement and Integration System for Multi-azimuthal Analysis (PRISMA, version 1.1.0) is a Python application for processing X-ray diffraction (XRD) image data. PRISMA wraps GSAS-II to perform azimuthally-binned peak refinement, computes per-frame strain and d-spacing from those fits, and provides three PyQt5 graphical interfaces: (1) a Recipe Builder for selecting GSAS-II control (.imctrl) files, optional mask (.immask) files or threshold-ased masking, reference and experiment image sets, peaks, zimuthal range and bin size, and an optional ceria-based auto-calibration; (2) a Batch Processor that uses Dask on local workstations and pure MPI (mpi4py.futures.MPICommExecutor) on HPC to distribute GSAS-II refinement across cores or compute nodes and write results to a 4-dimensional (peaks x frames x azimuths x measurements) Zarr dataset; and (3) a Data Analyzer that renders heatmaps of fit parameters, strain, frame-to-frame deltas, and percent-change-vs-reference, and exports user-defined subsections to CSV or Excel. The peak-refinement algorithm is deterministic. Benchmark on ALCF Crux: a 20,000-image set, single-peak fit in frame mode with 44 azimuthal bins on 128 nodes x 128 workers, 48 seconds total wall time.

Lorenzo Martin, Maria De La Cinta [Argonne Nationa↗

AXAF Coordinate Transformation at XRCF

Coordinate transformation between focal plane and detector pixel systems must be handled carefully at the X-ray Calibration Facility (XRCF) as it will be during flight. The High Resolution Mirror Assembly (HRMA) X-ray Detection System (HXDS) stage dithers, and the five-axis mount (FAM) attachment points underwent various types of motion during testing. At the XRCF when the FAM moved, the Science Instrument Module (SIM) travel direction was not necessarily aligned with the mirror axis motion, and, in addition, an arbitrary position offset had to be calibrated. Misalignment from the mirror axis was assessed by measuring its displacement from the boresight configuration of the default FAM frame, and the HXDS stage was monitored for motion from the default FAM reference point. Mirror position, prescribed in a mirror modal coordinate system, was measured in HRMA pitch and yaw axes. Prior to corrections for dithering and FAM movement, the coordinate data at XRCF also had to be corrected for possible misalignments of the mirror mount relative to XRCF and the default FAM axes due to the movement of the FAM feet. Those misalignments were processed in terms of yaw-pitch-roll Euler angles in the mirror nodal coordinate, and in the default FAM frame, respectively. An AXAF Science Center (ASC) coordinate library, pixlib, has been built to support these coordinate transformations and was used during x-ray calibration at the George C. Marshall Space Flight Center, Huntsville, AL. The design and implementation of this library will be discussed.

He, Helen↗

The Orbiter camera payload system's large-format camera and attitude reference system

The Orbiter camera payload system (OCPS) is an integrated photographic system carried into earth orbit as a payload in the Space Transportation System (STS) Orbiter vehicle's cargo bay. The major component of the OCPS is a large-format camera (LFC), a precision wide-angle cartographic instrument capable of producing high-resolution stereophotography of great geometric fidelity in multiple base-to-height ratios. A secondary and supporting system to the LFC is the attitude reference system (ARS), a dual-lens stellar camera array (SCA) and camera support structure. The SCA is a 70 mm film system that is rigidly mounted to the LFC lens support structure and, through the simultaneous acquisition of two star fields with each earth viewing LFC frame, makes it possible to precisely determine the pointing of the LFC optical axis with reference to the earth nadir point. Other components complete the current OCPS configuration as a high-precision cartographic data acquisition system. The primary design objective for the OCPS was to maximize system performance characteristics while maintaining a high level of reliability compatible with rocket launch conditions and the on-orbit environment. The full OCPS configuration was launched on a highly successful maiden voyage aboard the STS Orbiter vehicle Challenger on Oct. 5, 1984, as a major payload aboard the STS-41G mission.

Schardt, B. B.↗

Mission Report on the Orbiter Camera Payload System (OCPS) Large Format Camera (LFC) and Attitude Reference System (ARS)

The Orbiter Camera Payload System (OCPS) is an integrated photographic system which is carried into earth orbit as a payload in the Space Transportation System (STS) Orbiter vehicle's cargo bay. The major component of the OCPS is a Large Format Camera (LFC), a precision wide-angle cartographic instrument that is capable of producing high resolution stereo photography of great geometric fidelity in multiple base-to-height (B/H) ratios. A secondary, supporting system to the LFC is the Attitude Reference System (ARS), which is a dual lens Stellar Camera Array (SCA) and camera support structure. The SCA is a 70-mm film system which is rigidly mounted to the LFC lens support structure and which, through the simultaneous acquisition of two star fields with each earth-viewing LFC frame, makes it possible to determine precisely the pointing of the LFC optical axis with reference to the earth nadir point. Other components complete the current OCPS configuration as a high precision cartographic data acquisition system. The primary design objective for the OCPS was to maximize system performance characteristics while maintaining a high level of reliability compatible with Shuttle launch conditions and the on-orbit environment. The full-up OCPS configuration was launched on a highly successful maiden voyage aboard the STS Orbiter vehicle Challenger on October 5, 1984, as a major payload aboard mission STS 41-G. This report documents the system design, the ground testing, the flight configuration, and an analysis of the results obtained during the Challenger mission STS 41-G.

Mollberg, Bernard H.↗

Radiation Exposure in Nonvascular Fluoroscopy-Guided Interventional Procedures

Purpose: To investigate the radiation exposure in non-vascular fluoroscopy guided interventions and to search strategies for dose reduction. Materials and Methods: Dose area product (DAP) of 638 consecutive non-vascular interventional procedures of one year were analyzed with respect to different types of interventions; gastrointestinal tract, biliary interventions, embolizations of tumors and hemorrhage. Data was analyzed with special focus on the fluoroscopy doses and frame doses. The third quartiles (Q3) of fluoroscopy dose values were defined in order to set a reference value for our in-hospital practice. Results: Mean fluoroscopy times of gastrostomy, jejunostomy, right and left sided percutaneous biliary drainage, chemoembolization of the liver and embolization due to various hemorrhages were 5.9, 8.6, 13.5, 16.6, 17.4 and 25.2 min, respectively. The respective Q3 total DAP were 52.9, 73.3, 155.1, 308.4, 428.6 and 529.3 Gy*cm{sup 2}. Overall, around 66% of the total DAP originated from the radiographic frames with only 34% of the total DAP applied by fluoroscopy (P < 0.001). The investigators experience had no significant impact on the total DAP applied, most likely since there was no stratification to intervention-complexity. Conclusion: To establish Diagnostic Reference Levels (DRLs), there is a need to establish a registry of radiation dose data for the most commonly performed procedures. Documentation of interventional procedures by fluoroscopy 'grabbing' has the potential to considerably reduce radiation dose applied and should be used instead of radiographic frames whenever possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

VLBI FOR GRAVITY PROBE B. VII. THE EVOLUTION OF THE RADIO STRUCTURE OF IM PEGASI

We present measurements of the total radio flux density as well as very long baseline interferometry images of the star, IM Pegasi, which was used as the guide star for the NASA/Stanford relativity mission Gravity Probe B. We obtained flux densities and images from 35 sessions of observations at 8.4 GHz ({lambda} = 3.6 cm) between 1997 January and 2005 July. The observations were accurately phase-referenced to several extragalactic reference sources, and we present the images in a star-centered frame, aligned by the position of the star as derived from our fits to its orbital motion, parallax, and proper motion. Both the flux density and the morphology of IM Peg are variable. For most sessions, the emission region has a single-peaked structure, but 25% of the time, we observed a two-peaked (and on one occasion perhaps a three-peaked) structure. On average, the emission region is elongated by 1.4 {+-} 0.4 mas (FWHM), with the average direction of elongation being close to that of the sky projection of the orbit normal. The average length of the emission region is approximately equal to the diameter of the primary star. No significant correlation with the orbital phase is found for either the flux density or the direction of elongation, and no preference for any particular longitude on the star is shown by the emission region.

79 ASTRONOMY AND ASTROPHYSICS↗

Pseudo noise testing, supplement 2S

The report is divided into three parts describing three tasks. These tasks include: (1) a study of the application of pseudo noise testing; (2) a modification of the PN Test Set to include the capability of digital filtering in the data and reference channels; and (3) a study of synthesis procedure for long PCM frame synchronization words.

Source record↗

Setup Accuracy of the Novalis ExacTrac 6DOF System for Frameless Radiosurgery

Purpose: Stereotactic radiosurgery using frame-based positioning is a well-established technique for the treatment of benign and malignant lesions. By contrast, a new trend toward frameless systems using image-guided positioning techniques is gaining mainstream acceptance. This study was designed to measure the detection and positioning accuracy of the ExacTrac/Novalis Body (ET/NB) for rotations and to compare the accuracy of the frameless with the frame-based radiosurgery technique. Methods and Materials: A program was developed in house to rotate reference computed tomography images. The angles measured by the system were compared with the known rotations. The accuracy of ET/NB was evaluated with a head phantom with seven lead beads inserted, mounted on a treatment couch equipped with a robotic tilt module, and was measured with a digital water level and portal films. Multiple hidden target tests (HTT) were performed to measure the overall accuracy of the different positioning techniques for radiosurgery (i.e., frameless and frame-based with relocatable mask or invasive ring, respectively). Results: The ET/NB system can detect rotational setup errors with an average accuracy of 0.09 Degree-Sign (standard deviation [SD] 0.06 Degree-Sign ), 0.02 Degree-Sign (SD 0.07 Degree-Sign ), and 0.06 Degree-Sign (SD 0.14 Degree-Sign ) for longitudinal, lateral, and vertical rotations, respectively. The average positioning accuracy was 0.06 Degree-Sign (SD 0.04 Degree-Sign ), 0.08 Degree-Sign (SD 0.06 Degree-Sign ), and 0.08 Degree-Sign (SD 0.07 Degree-Sign ) for longitudinal, lateral and vertical rotations, respectively. The results of the HTT showed an overall three-dimensional accuracy of 0.76 mm (SD 0.46 mm) for the frameless technique, 0.87 mm (SD 0.44 mm) for the relocatable mask, and 1.19 mm (SD 0.45 mm) for the frame-based technique. Conclusions: The study showed high detection accuracy and a subdegree positioning accuracy. On the basis of phantom studies, the frameless technique showed comparable accuracy to the frame-based approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-18A-04: 3D Dictionary Learning Based Statistical Iterative Reconstruction for Low-Dose Cone Beam CT Imaging

Purpose: To develop a 3D dictionary learning based statistical reconstruction algorithm on graphic processing units (GPU), to improve the quality of low-dose cone beam CT (CBCT) imaging with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms) of 3x3x3 voxels was trained from a high quality volume image. During reconstruction, we utilized a Cholesky decomposition based orthogonal matching pursuit algorithm to find a sparse representation on this dictionary basis of each patch in the reconstructed image, in order to regularize the image quality. To accelerate the time-consuming sparse coding in the 3D case, we implemented our algorithm in a parallel fashion by taking advantage of the tremendous computational power of GPU. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with a tight frame (TF) based one using a subset data of 121 projections. The image qualities under different resolutions in z-direction, with or without statistical weighting are also studied. Results: Compared to the TF-based CBCT reconstruction, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, to remove more streaking artifacts, and is less susceptible to blocky artifacts. It is also observed that statistical reconstruction approach is sensitive to inconsistency between the forward and backward projection operations in parallel computing. Using high a spatial resolution along z direction helps improving the algorithm robustness. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppressing noise, and hence to achieve high quality reconstruction. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential clinical application. A high zresolution is preferred to stabilize statistical iterative reconstruction. This work was supported in part by NIH(1R01CA154747-01), NSFC((No. 61172163), Research Fund for the Doctoral Program of Higher Education of China (No. 20110201110011), China Scholarship Council.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Byggmeister Test Home: Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit

The Building Science Corporation seeks to further the energy efficiency market for retrofit projects in the New England area by supporting projects that are based on solid building science fundamentals and verified implementation. The Building Science Corporation has been working with Byggmeister, a partner on its Building America Program team, on retrofit projects. Byggmeister is a Boston-area design-build firm that specializes in energy efficient retrofits and new construction. The DEAP (Duclos, Eldrenkamp and Panish) Energy Group, which is associated with Byggmeister, conducts energy analysis for projects during design and performs monitoring after completion. With the high exposure of energy efficiency and retrofit terminology currently being used in the general media, it is important to have evidence that measures being proposed will in fact benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. Concrete data from specific projects can close the gap between “hype” and reality. This technical report describes a deep energy retrofit project for a two-family wood framed home located in Belmont, Massachusetts. Built in the 1920s, this home is referred to in this report as the “Belmont Two-Family.” The report examines the retrofit measures for the enclosure and mechanical systems and the decision making that took place during project planning. Because the retrofit project is complete, projected and actual energy use data are compared for the 5 months immediately following the retrofit. Occupant reactions and experiences are also described. The retrofit measures implemented for the Belmont Two-Family resulted in a home with airtightness of 0.93 air changes per hour at 50 pascal test pressure, a Home Energy Rating System index of 44 (excluding photovoltaics), and initial energy use significantly less than the energy models projected. The home is on track to meet the Thousand Home Challenge. In these ways, the project meets or exceeds the energy goals established for the retrofit. Energy modeling tools were found to be useful during the planning stage for investigating the relative cost effectiveness of retrofit measures. They were less effective, however, in projecting actual energy use. Discrepancies between the results of different tools need to be better understood, and interactions among retrofit measures are not effectively handled by the energy modeling tools at this time. During the first few months after the retrofit, the homeowner had questions about the effective operation of the mechanical equipment. With the increased airtightness and R-values, the equipment needs to be operated differently to realize the potential energy savings. This information needs to be better understood and disseminated by everyone involved with retrofit projects. This technical report contributes to several basic areas of research. These include the combination of measures that is feasible, affordable, and acceptable to homeowners as well as expectations versus results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring mandibular motions

Mandibular motion along three axes is measured by three motion transducers on floating yoke that rests against mandible. System includes electronics to provide variety of outputs for data display and processing. Head frame is strapped to test subject's skull to provide fixed point of reference for transducers.

Dimeff, J.↗

On the excitation of cyclotron harmonic waves by newborn heavy ions

Wave measurements in planetary foreshocks and cometary environments show the sporadic occurrence of magnetic spectra with harmonic structure related to ion-cyclotron frequencies. Dilute populations of anisotropic and/or drifting charged particles can excite obliquely propagating modes with spacecraft frequencies close to the observed harmonics. Previous analyses of this generation mechanism are extended to drifting and nondrifting loss-cone-type distributions of heavy ions in a dense hydrogen magnetoplasma, characterizing the complex (real frequency and growth rate) dispersion, polarization, and compressibility of the unstable cyclotron harmonic waves. Solution of the full kinetic dispersion equation shows that it is possible to attain harmonic excitation, both in the drifting and nondrifting regimes. However, the bandwidth inherent to frequency Doppler shifts of obliquely propagating waves might preclude the observation of spectral structure in the spacecraft frame. The Giotto observations in the upstream region of comet Halley provide a reference to discuss the results.

Brinca, Armando L.↗

Ionospheric calibration for single frequency altimeter measurements

This study is a preliminary analysis of the effectiveness (in terms of altimeter calibration accuracy) of various ionosphere models and the Global Positioning System (GPS) to calibrate single frequency altimeter height measurements for ionospheric path delay. In particular, the research focused on ingesting GPS Total Electron Content (TEC) data into the physical Parameterized Real-Time Ionospheric Specification Model (PRISM), which estimates the composition of the ionosphere using independent empirical and physical models and has the capability of adjusting to additional ionospheric measurements. Two types of GPS data were used to adjust the PRISM model: GPS receiver station data mapped from line-of-sight observations to the vertical at the point of interest and a grid map (generated at the Jet Propulsion Laboratory) of GPS derived TEC in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by the International Reference Ionosphere (IRI-90), a climatological (monthly mean) model of the ionosphere, were compared to TOPEX dual-frequency TEC measurements (considered as truth) for a number of TOPEX sub-satellite tracks. For a 13.6 GHz altimeter, a Total Electron Content (TEC) of 1 TECU 10(exp 16) electrons/sq m corresponds to approximately 0.218 centimeters of range delay. A maximum expected TEC (at solar maximum or during solar storms) of 10(exp 18) electrons/sq m will create 22 centimeters of range delay. Compared with the TOPEX data, the PRISM predictions were generally accurate within the TECU when the sub-satellite track of interest passed within 300 to 400 km of the GPS TEC data or when the track passed through a night-time ionosphere. If neither was the case, in particular if the track passed through a local noon ionosphere, the PRISM values differed by more than 10 TECU and by as much as 40 TECU. The IRI-90 model, with no current ability to unseat GPS data, predicted TEC to a slightly higher error of 12 TECU. The performance of PRISM is very promising for predicting TEC and will prove useful for calibrating single frequency altimeter height measurements for ionospheric path delay. When adjusted to the GPS line-of-sight data the PRISM URSI empirical model predicted TEC over a day's period to within a global error of 8.60 TECU rms during a nighttime ionosphere and 9.74 TECU rms during the day. When adjusted to the GPS derived TEC grid, the PRISM parametrized model predicted TEC to within an error of 8.47 TECU rms for a nighttime ionosphere and 12.83 TECU rms during the day. However, the grid cannot be considered globally due to the lack of sufficient numbers of GPS stations and large latitude gaps in GPS data. It is the opinion of the authors that using the PRISM model and adjusting to the global sun-fixed TEC grid regenerated with a localized weighted interpolation offers the best possibility of meeting the 10 TECU global rms (or 2 cm at 13.6 GHz) ionosphere range correction accuracy requirement of TOPEX/Poseidon and should be the subject of further study. However, it is clear that the anticipated requirement of 34 TECU global rms for TOPEX/Poseidon Follow-On (corresponding to the TOPEX/Poseidon performance) can not be met with any realizable combination of existing models and data assimilation schemes.

Schreiner, William S.↗

GPS Disciplined Oscillators for Traceability to the Italian Time Standard

The Istituo Elettrotecnico Nazionale (IEN) is one of the Italian primary institutes which is responsible for the accreditation of secondary laboratories belong to the national calibration system (SNT) established by law in 1991. The Times and Frequency Department that has accredited in this frame 14 calibration centers for frequency, performs also the remote calibration of their reference oscillators by means of different synchronization systems. The problem of establishing the traceability of the national time standard of the Global Positioning System (GPS) disciplined oscillators has been investigated and the results obtained are reported.

Cordara, Franco↗