Synchrotron Radiation Workshop (SRW)

"Synchrotron Radiation Workshop" (SRW) is a physical optics computer code for calculation of detailed characteristics of Synchrotron Radiation (SR) generated by relativistic electrons in magnetic fields of arbitrary configuration and for simulation of the radiation wavefront propagation through optical systems of beamlines. Frequency-domain near-field methods are used for the SR calculation, and the Fourier-optics based approach is generally used for the wavefront propagation simulation. The code enables both fully- and partially-coherent radiation propagation simulations in steady-state and in frequency-/time-dependent regimes. With these features, the code has already proven its utility for a large number of applications in infrared, UV, soft and hard X-ray spectral range, in such important areas as analysis of spectral performances of new synchrotron radiation sources, optimization of user beamlines, development of new optical elements, source and beamline diagnostics, and even complete simulation of SR based experiments. Besides the SR applications, the code can be efficiently used for various simulations involving conventional lasers and other sources. SRW versions interfaced to Python and to IGOR Pro (WaveMetrics), as well as cross-platform library with C API, are available.

Chubar, O.↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The National Security Technologies, LLC, Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with a FWHM resolution of 3.2% at the 137Cs 662 keV gamma energy. RSL completed a crystal assessment and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using the DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function of photons per unit energy, were calculated. Specifically, we report excellent linearity with the aliovalent CeBr3:Ca2+ crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is the key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred by doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal as well as the assessment of benchmarking spectroscopy. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallites with diameters <1 cm. We obtain 3.2% before packing the crystallite in a sealed detector container and 4.5% for the packaged crystallite. More spectra were obtained for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

aliovalent substitution↗

Transversely-illuminated high current photoconductive switches with geometry-constrained conductivity path

A photoconductive switch having a wide bandgap semiconductor material substrate between opposing electrodes, with one of the electrodes having an aperture or apertures at an electrode-substrate interface for transversely directing radiation therethrough from a radiation source into a triple junction region of the substrate, so as to geometrically constrain the conductivity path to within the triple junction region.

36 MATERIALS SCIENCE↗

DEVELOPMENT OF SHORT UNDULATORS FOR ELECTRON-BEAM-RADIATION INTERACTION STUDIES

Interaction of an electron beam with external field or its own radiation has widespread applications ranging from coherent-radiation generation, phase space cooling or formation of temporally-structured beams. An efficient coupling mechanism between an electron beam and radiation field relies on the use of a magnetic undulator. In this contribution we detail our plans to build short (11-period) undulators with 7-cm period refurbishing parts of the aladdin U3 undulator [1]. Possible use of these undulators at available test facilities to support experiments relevant to cooling techniques and radiation sources are outlined.

43 PARTICLE ACCELERATORS↗

Digital Inject Book v. 1.7

Digital Inject Book is a software program designed to generate and managed simulated data for radiation detectors, used to increase the realism of training where real radiation sources are impractical, expensive, or simply not available.

Eldridge, Bryce↗

Initial Demonstration of 9-MHz Framing Camera Rates on the FAST UV Drive Laser Pulse Trains

We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D images are recorded with a Gig-E readout CCD camera. We also report a first proof of principle with an OTR source using the linac streak camera in a semi-framing mode.

43 PARTICLE ACCELERATORS↗

System and method for monitoring a wellbore

A detector assembly includes a scintillator configured to generate a light signal in response to an impinging radiation signal from an object, where the scintillator has a first end and a second end. Further, the detector assembly includes a first detector disposed adjacent the scintillator and configured to receive a first portion of the light signal from the scintillator and a second detector operatively coupled to the second end of the scintillator and configured to receive a second portion of the light signal from the scintillator. The detector assembly also includes a reflector operatively coupled to the scintillator and the first detector and configured to guide the light signal from the scintillator to the first detector, where the reflector is configured to redirect the first portion of the light signal by a determined amount to reduce a path length between a radiation source, the object, and the scintillator.

Kasten, Ansas Matthias↗

Composite materials having red emitting phosphors

A lighting apparatus includes an LED light source radiationally coupled to a composite material including a phosphor of formula I and a thermally conductive material dispersed in at least a portion of a binder material. The thermally conductive material includes a material selected from the group consisting of indium oxide, tin oxide, indium tin oxide, calcium oxide, barium oxide, strontium oxide, aluminum hydroxide, magnesium hydroxide, calcium hydroxide, barium hydroxide, strontium hydroxide, zinc hydroxide, aluminum phosphate, magnesium phosphate, calcium phosphate, barium phosphate, strontium phosphate, diamond, graphene, polyethylene nanofibers, carbon nanotubes, silver metal nanoparticles, copper metal nanoparticles, gold metal nanoparticles, aluminum metal nanoparticles, boron nitride, silicon nitride, an alkali metal halide, calcium fluoride, magnesium fluoride, a compound of formula II, and combinations thereof.

Porob, Digamber Gurudas↗

Design and Fabrication of a CdMnTe Nuclear Radiation Detection System

Cadmium manganese telluride (CdMnTe) is one of the ternary compounds of cadmium telluride (CdTe) that has shown great potential applications in the development of X-ray and gamma-ray detectors used in medical imaging and in the detection of radiological and nuclear threats. CdMnTe nuclear detectors are capable of operating at room temperature without cryogenic cooling. The goal of this project is to design and fabricate CdMnTe detection system that can be used in laboratory experiments for characterizing detector materials and for identification of radionuclides. The engineering design objectives include a spring-based sample holder, ability to measure electrical properties of CdTe-based semiconductor nuclear detectors, and the detection of nuclear radiations. This paper presents the design of the sample holder and the fabrication of a CdMnTe detector. The current-voltage characterization experimental results showed that the CdMnTe has the high resistivity needed for CdTe-based nuclear detectors. The results also include the response of the CdMnTe detector to the 59.5-keV gamma peak of Am-241 nuclear radiation source.

36 MATERIALS SCIENCE↗

Detailed Radiation Dose Rate Evaluations of Commercial Spent Nuclear Fuel Canisters

Electronic devices that are being designed for continuous monitoring of spent nuclear fuel (SNF) canister internal integrity may be subjected to very high radiation levels depending on their placement. Components of electronic devices (e.g., silicon semiconductors, optical glasses, insulators) have a limited tolerance to ionizing radiation. For selected locations on the inner and outer surfaces of a representative dry storage pressurized water reactor (PWR) SNF canister and a representative dry storage boiling water reactor (BWR) SNF canister, this paper provides (1) the dose rate in silicon as a function of decay time and (2) the time-integrated dose in silicon. The analyzed decay time interval is from 5 to 70 years after fuel discharge. Each representative canister contained identical SNF assemblies with bounding radiation sources. Surface dose rates varied significantly as a function of location and SNF assembly decay time. At a 5-year decay time, the estimated maximum dose rate values were 480 Gy/h (PWR canister) and ~366 Gy/h (BWR canister), and the estimated minimum dose rate was ~0.2 Gy/h for both canisters. Over a 65-year period, the dose rate decreased by a factor between 13 and 580, depending on location. The total dose over a time interval could be very large (e.g., estimated maximum value over a 5-year interval is 1.5E+07 Gy) depending on location and the time interval over which dose is accumulated.

Radulescu, Georgeta↗

Nanoparticles, methods for producing nanoparticles and nanoparticle generators

Compositions are provided that can include nanoscale particles including metal cations such as cerium having an average particle size of less than 10 nm. The nanoscale particles can include cerium and oxygen. Methods for forming nanoparticles are provided. The methods can include exposing a metal cation within a solution to radiation to form metal nanoparticles that can include metal cations. The methods can include exposing a cerium salt solution to radiation to form the nanoparticles. The methods can include exposing solvated metal cations to radiation to precipitate nanoparticles that include metal cations such as Ce. The methods can include exposing the homogeneous solution to radiation to precipitate nanoparticles. The methods can include: providing an aqueous solution comprising metal cations; and increasing the pH of the aqueous solution with radiation to form nanoparticles that include metal cations. Nanoparticle generators are provided. The generators can include: a reactant reservoir comprising a metal cation in solution; a fluid cell in fluid communication with the reactant reservoir; a radiation source operatively aligned with the fluid cell; and a product reservoir in fluid communication with the fluid cell.

36 MATERIALS SCIENCE↗

Multi-phased Approach for Detection Systems and Measures for Nuclear and other Radioactive Material Out of Regulatory Control

The Office of Nuclear Incident Policy and Cooperation and the Office of Nuclear Security Deterrence and Detection at the U.S. Department of Energy, National Nuclear Security Administration provide a multi-phased approach for detection systems and measures for nuclear and other radioactive material out of regulatory control in cargo shipments. The approach is designed using best practices to deter, detect, interdict, characterize, adjudicate, and recover illicit radiation sources. Two case studies will be presented which demonstrate the multi-phased approach to nuclear security.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On Feature, Classifier and Detector Fusers for U-235 Signatures Using Gamma Spectral Counts

Three types of information fusion strategies are studied to assess the performance of classifiers for detecting low-level U-235 radiation sources, using features obtained from gamma spectra of NaI detectors. These three strategies are based on using two spectral region features, fusing eight classifiers of diverse designs, and fusing multiple detectors located at different positions around the source. The inner, middle and outer groups of detectors, within a formation of two concentric circles and a spiral of 21 detectors, are identified based on their distance to the source, which is located at the center. This study provides two main qualitative insights into this classification task. First,the fusion of detectors leads to an overall improved classification performance, least in the inner group, most in the outer group, and in between for the middle group. Second, several classifiers and fusers achieve lower training error which does not translate to lower generalization error, indicating their over-fitting to training data.

Rao, Nageswara↗

Integration of the Kromek D3S Detector and Spot Robot For Secondary Inspections

Inspecting vehicles and containers for the presence of nuclear material is a challenging task for border control and security. When performed manually by inspectors, this task also has an associated risk of exposing the inspectors to unknown radiation. With the advent of agile, easy-to-program, quadruped robots like the Boston Dynamics Spot, automation of secondary inspection can improve the efficiency of the inspection process and alleviates the radiation risks to inspectors. In this project, Brookhaven National Laboratory and the University of Massachussetts at Lowell explored how to automate a simple secondary inspection mission. The Spot robot comes with its own software development kit (SDK) that allows clients/users to write custom code in the Python programming language to control the robot. Spot also has a payload computer called Spot-CORE, which runs the Ubuntu Linux operating system and allows users to integrate external sensors, such as a radiation detector, with Spot. In this study, the Kromek D3S detector has been integrated with Spot via the Spot-CORE, allowing Spot to capture gamma spectra and neutron counts for a specified acquisition period. Two custom routines, search and confirmation, have been developed and executed in this specified order. The search routine directs Spot to go around the nearest obstacle, e.g., vehicle and container, in a preset distance and step to collect gamma and neutron gross counts with the D3S detector. The radiation data and the robot location corresponding to each step are stored and fed to the confirmation routine at the end of the search. The confirmation routine then navigates Spot to the locations of the highest gamma or neutron counts to perform a long, e.g., one minute, measurement, and gives the operators the signature gamma spectra and neutron counts at the hotspots. This paper presents a detailed description of this automated system along with results of the preliminary tests in identifying the location and signature of a 137Cs radiation source in a vehicle.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Design and Validation of a Gammaray Scanning System for Measuring Irradiated Nuclear Fuel

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solving Inverse Transport Problems with Neutron Multiplication Measurements and Improved Differential Evolution

In the problem of inverse radiation transport, measurements of particle leakages from radioactive source/shield systems are used to infer unknown parameters within the systems. This reconstruction can be accomplished by finding the physical parameters of the unknown system that minimize the difference between calculated detector responses and measured detector responses. Recently, the differential evolution (DE) method was shown to be highly adept at solving inverse transport problems in which the measured quantities were leakages of unscattered gamma-ray lines. In this work, we present an extension of the DE method to problems in which both gamma-ray lines and neutron multiplication are measured. The neutron multiplication measurement is demonstrated to be an important addition when few gamma-ray lines are available. We also discuss the implementation of a variant of DE that significantly reduces the number of forward transport computations required to solve the inverse problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of Polynomial Chaos Expansion in One-Dimensional Inverse Transport Problems

In the problem of inverse radiation transport, measurements of particle leakages from radioactive source/shield systems are used to infer unknown parameters within the systems. This reconstruction can be accomplished by finding the physical parameters of the unknown system that minimize the difference between calculated detector responses and measured detector responses. The inverse transport solver should also propagate uncertainties from the detector responses to the reconstructed parameter values. Recently, the Differential Evolution Adaptive Metropolis (DREAM) method was shown to be a robust method for uncertainty quantification in inverse problems. The DREAM method uses the differential evolution algorithm to choose efficient steps in a Markov chain Monte Carlo (MCMC) simulation. Although the DREAM method has been shown to be more efficient than traditional MCMC approaches, it still requires thousands of transport computations to accurately quantify uncertainty. For the simple ray-tracing model, it was possible to perform these calculations in a reasonable amount of time (under an hour). However, inverse transport problems that require computationally-intensive transport solvers will need prohibitively long run times when using the DREAM method. A way to overcome the computational burden of the DREAM method is to perform surrogate modeling using the polynomial chaos expansion (PCE) approach. It was recently shown that the PCE method provides both accurate and computationally inexpensive uncertainty quantification in forward radiation source/shield problems. PCE was also recently applied to an inverse problem in nonlinear point reactor kinetics within a standard MCMC approach. PCE was first used with the DREAM method where it was applied to inverse problems in groundwater modeling.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DESIGN AND VALIDATION OF A GAMMA-RAY SCANNING SYSTEM FOR MEASURING IRRADIATED NUCLEAR FUEL (ABSTRACT)

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗