Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Quality Assurance of Radiation Therapy Planning Systems: Current Status and Remaining Challenges

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both 'type' tests to be performed in the factory and 'site' tests to be performed in the clinic. The American Association of Physicists Task Group Report 67 described benchmark tests for the validation of dose calculation algorithms. Test data are being produced with the backing of the U.S. National Cancer Institute. However, significant challenges remain. Technology keeps evolving rapidly, thus requiring new quality assurance (QA) procedures. Intensity-modulated radiation therapy with its use of inverse optimization has added a new dimension to QA, because the results are not intuitively obvious. New technologies such as real-time ultrasound guidance for brachytherapy, TomoTherapy, and Cyberknife, require their own specialized RTPSs with unique QA requirements. On-line imaging allows for the generation of dose reconstructions using image warping techniques to determine the daily dose delivered to the patient. With increasing computer speeds, real-time reoptimization of treatment plans will become a reality. Gating technologies will require four-dimensional dose calculations to determine the actual dose delivered to tissue voxels. With these rapidly changing technologies, it is essential that a strong QA culture is invoked in every institution implementing these procedures and that new protocols are developed as a part of the clinical implementation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

Phase I-II Trial of Cetuximab, Capecitabine, Oxaliplatin, and Radiotherapy as Preoperative Treatment in Rectal Cancer

Purpose: To evaluate the safety and activity of preoperative radiotherapy (RT) with concurrent cetuximab, capecitabine, and oxaliplatin in rectal cancer patients. Patients and Methods: A total of 60 patients with rectal cancer (T3-T4 or N+, M1 allowed) entered the trial at five investigator sites; the data from 58 patients were assessable. Cetuximab was given as an initial dose of 400 mg/m{sup 2} 7 days before the start of RT, and then at 250 mg/m{sup 2} once weekly during RT (50.4 Gy in 28 fractions). Capecitabine and oxaliplatin were administered according to an established schedule of oxaliplatin (50 mg/m{sup 2} on Days 1, 8, 22, and 29) and capecitabine (Days 1-14 and 22-35) at three dose levels: 1,000, 1,300, and 1,650 mg/m{sup 2}/d during the Phase I part of the study. The main endpoint of the Phase II was the pathologic complete response rate. Results: Thirteen patients were included in the Phase I part of the study, and the maximal tolerated dose was not reached. Overall, 48 patients were treated at the recommended dose of capecitabine (1,650 mg/m{sup 2}) and 45 patients (94%) underwent surgery. A pathologic complete response was observed in 4 patients (9%), and moderate (n = 12), minimal (n = 10), and no tumor regression (n = 2) was noted in 24 (53%) of 45 patients. The mean radiation dose intensity, cetuximab, capecitabine, oxaliplatin was 98%, 95%, 94%, and 94%, respectively. The incidence of Grade 3-4 diarrhea was restricted to 19%. Postoperative complications of any grade occurred in 33% of patients. Conclusions: The results of our study have shown that cetuximab can be combined safely with capecitabine and oxaliplatin plus RT. The low pathologic complete response rate achieved should stimulate additional preclinical investigations to establish the best sequence of triple combinations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long- and short-lived electrons with anomalously high collision rates in laser-ionized gases

Ultrashort broadband terahertz pulses are applied to probe the electron dynamics of gaseous Ar and O{sub 2} following ionization by an intense femtosecond laser pulse. The conductivity in the plasma center is extracted by a modified Wentzel-Kramers-Brillouin approach. It exhibits a nearly perfect Drude-like spectral shape and yields the temporal evolution of the free-electron density and collision rate. While the electron density in the Ar plasma remains nearly constant during the first 200 ps after generation, it decays much faster in O{sub 2} due to dissociative recombination which is only possible in molecular plasmas. Adding a small amount of the electron scavenger SF{sub 6} to Ar reduces the electron lifetime in the plasma dramatically and allows us to determine the electron temperature to about 20 000 K. Furthermore, anomalously high, metal-like electron collision rates of up to 25 THz are found. Kinetic plasma theory substantially underestimates these rates pointing towards additional and more complex processes randomizing the total electronic momentum. Our results are relevant to both lightning control and generation of terahertz radiation by intense laser pulses in gases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching and also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 {+-} 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 {+-} 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 {+-} 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 {+-} 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The baseline shift-monitoring system with the displacement-based methods for highly accurate respiratory-gated treatments should be used to make most of the displacement-based gating methods. Conclusions: The advent of intensity modulated radiation therapy and volumetric modulated radiation therapy facilitates margin reduction for the planning target volumes and the OARs, but highly accurate irradiation is needed to achieve target coverage and OAR sparing with a small margin. The baseline shifts can affect treatment not only with the respiratory gating system but also without the system. Our system can manage the baseline shift and also enables treatment irradiation to be undertaken with high accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-E-BRE-08: GPU-Monte Carlo Based Fast IMRT Plan Optimization

Purpose: Intensity-modulated radiation treatment (IMRT) plan optimization needs pre-calculated beamlet dose distribution. Pencil-beam or superposition/convolution type algorithms are typically used because of high computation speed. However, inaccurate beamlet dose distributions, particularly in cases with high levels of inhomogeneity, may mislead optimization, hindering the resulting plan quality. It is desire to use Monte Carlo (MC) methods for beamlet dose calculations. Yet, the long computational time from repeated dose calculations for a number of beamlets prevents this application. It is our objective to integrate a GPU-based MC dose engine in lung IMRT optimization using a novel two-steps workflow. Methods: A GPU-based MC code gDPM is used. Each particle is tagged with an index of a beamlet where the source particle is from. Deposit dose are stored separately for beamlets based on the index. Due to limited GPU memory size, a pyramid space is allocated for each beamlet, and dose outside the space is neglected. A two-steps optimization workflow is proposed for fast MC-based optimization. At first step, rough beamlet dose calculations is conducted with only a small number of particles per beamlet. Plan optimization is followed to get an approximated fluence map. In the second step, more accurate beamlet doses are calculated, where sampled number of particles for a beamlet is proportional to the intensity determined previously. A second-round optimization is conducted, yielding the final Result. Results: For a lung case with 5317 beamlets, 10{sup 5} particles per beamlet in the first round, and 10{sup 8} particles per beam in the second round are enough to get a good plan quality. The total simulation time is 96.4 sec. Conclusion: A fast GPU-based MC dose calculation method along with a novel two-step optimization workflow are developed. The high efficiency allows the use of MC for IMRT optimizations.

60 APPLIED LIFE SCIENCES↗

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Use of 4DCT to Reduce Lung Dose: A Dosimetric Analysis

Dosimetric studies on respiratory movement suggest several advantages toward the use of 4-dimensional computed tomography (4DCT) in radiation treatment planning. 4DCT is a method to obtain a series of CT scans each representing a different respiratory phase. The use of 4DCT has provided substantial information on tumor movement in the lung, allowing for the creation of custom planning margins explicitly including respiratory motion. These custom motion margins may result in an increase in the amount of normal lung in the field; however, it is believed less normal lung is irradiated than if generic motion margins were used. Clinical data regarding dose to normal lung by using 4DCT remain rather limited. Thus, a study presenting figures on the change in normal lung dose between planned free breathing CT and 4DCT cases would be useful to the dosimetry community. We have generated plans comparing fast spiral CT and 4DCT in regard to tumor coverage and the resulting dose to normal lung for the clinical target volume (CTV) and planning target volume (PTV) expansions used at our institution. These data were analyzed for free breathing and 4D plans of 6 lung cancer patients using intensity modulated radiation therapy (IMRT). We compared doses to normal lung tissue between free breathing and 4DCT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the minimum number of radiation field parameters to specify gas cooling and heating functions

Fast and accurate approximations of gas cooling and heating functions are needed for hydrodynamic galaxy simulations. We use machine learning to analyze atomic gas cooling and heating functions in the presence of a generalized incident local radiation field computed by Cloudy. We characterize the radiation field through binned radiation field intensities instead of the photoionization rates used in our previous work. We find a set of 6 energy bins whose intensities exhibit relatively low correlation. We use these bins as features to train machine learning models to predict Cloudy cooling and heating functions at fixed metallicity. We compare the relative SHapley Additive exPlanation (SHAP) value importance of the features. From the SHAP analysis, we identify a feature subset of 3 energy bins (0.5-1, 1-4, and 13-16Ry) with the largest importance and train additional models on this subset. We compare the mean squared errors and distribution of errors on both the entire training data table and a randomly selected 20% test set withheld from model training. The machine learning models trained with 3 and 6 bins, as well as 3 and 4 photoionization rates, have comparable accuracy everywhere, with errors ≳10 times smaller than for the interpolation table of Gnedin and Hollon (2012). We conclude that 3 energy bins (or 3 analogous photoionization rates: molecular hydrogen photodissociation, neutral hydrogen HI, and fully ionized carbon CVI) are sufficient to characterize the dependence of the gas cooling and heating functions on our assumed incident radiation field model.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-Time Pretreatment Review Limits Unacceptable Deviations on a Cooperative Group Radiation Therapy Technique Trial: Quality Assurance Results of RTOG 0933

Purpose: RTOG 0933 was a phase II trial of hippocampal avoidance during whole brain radiation therapy for patients with brain metastases. The results demonstrated improvement in short-term memory decline, as compared with historical control individuals, and preservation of quality of life. Integral to the conduct of this trial were quality assurance processes inclusive of pre-enrollment credentialing and pretreatment centralized review of enrolled patients. Methods and Materials: Before enrolling patients, all treating physicians and sites were required to successfully complete a “dry-run” credentialing test. The treating physicians were credentialed based on accuracy of magnetic resonance imaging–computed tomography image fusion and hippocampal and normal tissue contouring, and the sites were credentialed based on protocol-specified dosimetric criteria. Using the same criteria, pretreatment centralized review of enrolled patients was conducted. Physicians enrolling 3 consecutive patients without unacceptable deviations were permitted to enroll further patients without pretreatment review, although their cases were reviewed after treatment. Results: In all, 113 physicians and 84 sites were credentialed. Eight physicians (6.8%) failed hippocampal contouring on the first attempt; 3 were approved on the second attempt. Eight sites (9.5%) failed intensity modulated radiation therapy planning on the first attempt; all were approved on the second attempt. One hundred thirteen patients were enrolled in RTOG 0933; 100 were analyzable. Eighty-seven cases were reviewed before treatment; 5 (5.7%) violated the eligibility criteria, and 21 (24%) had unacceptable deviations. With feedback, 18 cases were approved on the second attempt and 2 cases on the third attempt. One patient was treated off protocol. Twenty-two cases were reviewed after treatment; 1 (4.5%) violated the eligibility criteria, and 5 (23%) had unacceptable deviations. Conclusions: Although >95% of the cases passed the pre-enrollment credentialing, the pretreatment centralized review disqualified 5.7% of reviewed cases, prevented unacceptable deviations in 24% of reviewed cases, and limited the final unacceptable deviation rate to 5%. Thus, pretreatment review is deemed necessary in future hippocampal avoidance trials and is potentially useful in other similarly challenging radiation therapy technique trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the minimum number of radiation field parameters to specify gas cooling and heating functions

Fast and accurate approximations of gas cooling and heating functions are needed for hydrodynamic galaxy simulations. We use machine learning to analyze atomic gas cooling and heating functions computed by Cloudy in the presence of a generalized incident local radiation field. We characterize the radiation field through binned radiation field intensities instead of the photoionization rates used in our previous work. We find a set of 6 energy bins whose intensities exhibit relatively low correlation. We use these bins as features to train machine learning models to predict Cloudy cooling and heating functions at fixed metallicity. We compare the relative SHapley Additive exPlanation (SHAP) value importance of the features. From the SHAP analysis, we identify a feature subset of 3 energy bins ($0.5-1, 1-4$, and $13-16 \, \mathrm{Ry}$) with the largest importance and train additional models on this subset. We compare the mean squared errors and distribution of errors on both the entire training data table and a randomly selected 20% test set withheld from model training. The machine learning models trained with 3 and 6 bins, as well as 3 and 4 photoionization rates, have comparable accuracy everywhere, with errors $\gtrsim 10$ times smaller than for the interpolation table of Gnedin and Hollon (2012). We conclude that 3 energy bins (or 3 analogous photoionization rates: molecular hydrogen photodissociation, neutral hydrogen HI, and fully ionized carbon CVI) are sufficient to characterize the dependence of the gas cooling and heating functions on our assumed incident radiation field model.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation

This study introduces a charge coupled device (CCD) area detector based optical-computed tomography (optical-CT) scanner for comprehensive verification of radiation dose distributions recorded in nonscattering radiochromic dosimeters. Defining characteristics include: (i) a very fast scanning time of {approx}5 min to acquire a complete three-dimensional (3D) dataset, (ii) improved image formation through the use of custom telecentric optics, which ensures accurate projection images and minimizes artifacts from scattered and stray-light sources, and (iii) high resolution (potentially 50 {mu}m) isotropic 3D dose readout. The performance of the CCD scanner for 3D dose readout was evaluated by comparison with independent 3D readout from the single laser beam OCTOPUS-scanner for the same PRESAGE dosimeters. The OCTOPUS scanner was considered the 'gold standard' technique in light of prior studies demonstrating its accuracy. Additional comparisons were made against calculated dose distributions from the ECLIPSE treatment-planning system. Dose readout for the following treatments were investigated: (i) a single rectangular beam irradiation to investigate small field and very steep dose gradient dosimetry away from edge effects, (ii) a 2-field open beam parallel-opposed irradiation to investigate dosimetry along steep dose gradients, and (iii) a 7-field intensity modulated radiation therapy (IMRT) irradiation to investigate dosimetry for complex treatment delivery involving modulation of fluence and for dosimetry along moderate dose gradients. Dose profiles, dose-difference plots, and gamma maps were employed to evaluate quantitative estimates of agreement between independently measured and calculated dose distributions. Results indicated that dose readout from the CCD scanner was in agreement with independent gold-standard readout from the OCTOPUS-scanner as well as the calculated ECLIPSE dose distribution for all treatments, except in regions within a few millimeters of the edge of the dosimeter, where edge artifact is predominant. Agreement of line profiles was observed, even along steep dose gradients. Dose difference plots indicated that the CCD scanner dose readout differed from the OCTOPUSscanner readout and ECLIPSE calculations by {approx}10% along steep dose gradients and by {approx}5% along moderate dose gradients. Gamma maps (3% dose-difference and 3 mm distance-to-agreement acceptance criteria) revealed agreement, except for regions within 5 mm of the edge of the dosimeter where the edge artifact occurs. In summary, the data demonstrate feasibility of using the fast, high-resolution CCD scanner for comprehensive 3D dosimetry in all applications, except where dose readout is required close to the edges of the dosimeter. Further work is ongoing to reduce this artifact.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quality Assurance Peer Review Chart Rounds in 2011: A Survey of Academic Institutions in the United States

Purpose: In light of concerns regarding the quality of radiation treatment delivery, we surveyed the practice of quality assurance peer review chart rounds at American academic institutions. Methods and Materials: An anonymous web-based survey was sent to the chief resident of each institution across the United States. Results: The response rate was 80% (57/71). The median amount of time spent per patient was 2.7 minutes (range, 0.6-14.4). The mean attendance by senior physicians and residents was 73% and 93%, respectively. A physicist was consistently present at peer review rounds in 66% of departments. There was a close association between attendance by senior physicians and departmental organization: in departments with protected time policies, good attendance was 81% vs. 31% without protected time (p = 0.001), and in departments that documented attendance, attending presence was 69% vs. 29% in departments without documentation (p < 0.05). More than 80% of institutions peer review all external beam therapy courses; however, rates were much lower for other modalities (radiosurgery 58%, brachytherapy 40%-47%). Patient history, chart documentation, and dose prescription were always peer reviewed in >75% of institutions, whereas dosimetric details (beams, wedges), isodose coverage, intensity-modulated radiation therapy constraints, and dose-volume histograms were always peer reviewed in 63%, 59%, 42%, and 50% of cases, respectively. Chart rounds led to both minor (defined as a small multileaf collimator change/repeated port film) and major (change to dose prescription or replan with dosimetry) treatment changes. Whereas at the majority of institutions changes were rare (<10% of cases), 39% and 11% of institutions reported that minor and major changes, respectively, were made to more than 10% of cases. Conclusion: The implementation of peer review chart rounds seems inconsistent across American academic institutions. Brachytherapy and radiosurgical procedures are rarely reviewed. Attendance by senior physicians is variable, but it improves when scheduling clashes are avoided. The potential effect of a more thorough quality assurance peer review on patient outcomes is not known.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic planning on hippocampal avoidance whole-brain radiotherapy

Mounting evidence suggests that radiation-induced damage to the hippocampus plays a role in neurocognitive decline for patients receiving whole-brain radiotherapy (WBRT). Hippocampal avoidance whole-brain radiotherapy (HA-WBRT) has been proposed to reduce the putative neurocognitive deficits by limiting the dose to the hippocampus. However, urgency of palliation for patients as well as the complexities of the treatment planning may be barriers to protocol enrollment to accumulate further clinical evidence. This warrants expedited quality planning of HA-WBRT. Pinnacle{sup 3} Automatic treatment planning was designed to increase planning efficiency while maintaining or improving plan quality and consistency. The aim of the present study is to evaluate the performance of the Pinnacle{sup 3} Auto-Planning on HA-WBRT treatment planning. Ten patients previously treated for brain metastases were selected. Hippocampal volumes were contoured on T1 magnetic resonance (MR) images, and planning target volumes (PTVs) were generated based on RTOG0933. The following 2 types of plans were generated by Pinnacle{sup 3} Auto-Planning: the one with 2 coplanar volumetric modulated arc therapy (VMAT) arcs and the other with 9-field noncoplanar intensity-modulated radiation therapy (IMRT). D{sub 2%} and D{sub 98%} of PTV were used to calculate homogeneity index (HI). HI and Paddick Conformity index (CI) of PTV as well as D{sub 100%} and D{sub max} of the hippocampus were used to evaluate the plan quality. All the auto-plans met the dose coverage and constraint objectives based on RTOG0933. The auto-plans eliminated the necessity of generating pseudostructures by the planners, and it required little manual intervention which expedited the planning process. IMRT quality assurance (QA) results also suggest that all the auto-plans are practically acceptable on delivery. Pinnacle{sup 3} Auto-Planning generates acceptable plans by RTOG0933 criteria without time-consuming planning process. The expedited quality planning achieved by Auto-Planning (AP) may facilitate protocol enrollment of patients to further investigate the hippocampal-sparing effect and be used to ensure timely start of palliative treatment in future clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm

Purpose: Radiation treatments are trending toward delivering higher doses per fraction under stereotactic radiosurgery and hypofractionated treatment regimens. There is a need for accurate 3D in vivo patient dose verification using electronic portal imaging device (EPID) measurements. This work presents a model-based technique to compute full three-dimensional patient dose reconstructed from on-treatment EPID portal images (i.e., transmission images). Methods: EPID dose is converted to incident fluence entering the patient using a series of steps which include converting measured EPID dose to fluence at the detector plane and then back-projecting the primary source component of the EPID fluence upstream of the patient. Incident fluence is then recombined with predicted extra-focal fluence and used to calculate 3D patient dose via a collapsed-cone convolution method. This method is implemented in an iterative manner, although in practice it provides accurate results in a single iteration. The robustness of the dose reconstruction technique is demonstrated with several simple slab phantom and nine anthropomorphic phantom cases. Prostate, head and neck, and lung treatments are all included as well as a range of delivery techniques including VMAT and dynamic intensity modulated radiation therapy (IMRT). Results: Results indicate that the patient dose reconstruction algorithm compares well with treatment planning system computed doses for controlled test situations. For simple phantom and square field tests, agreement was excellent with a 2%/2 mm 3D chi pass rate ≥98.9%. On anthropomorphic phantoms, the 2%/2 mm 3D chi pass rates ranged from 79.9% to 99.9% in the planning target volume (PTV) region and 96.5% to 100% in the low dose region (>20% of prescription, excluding PTV and skin build-up region). Conclusions: An algorithm to reconstruct delivered patient 3D doses from EPID exit dosimetry measurements was presented. The method was applied to phantom and patient data sets, as well as for dynamic IMRT and VMAT delivery techniques. Results indicate that the EPID dose reconstruction algorithm presented in this work is suitable for clinical implementation.

60 APPLIED LIFE SCIENCES↗

Adaptive diffusion smoothing: A diffusion-based method to reduce IMRT field complexity

Inverse-planned intensity modulated radiation therapy (IMRT) is often able to achieve complex treatment planning goals that are unattainable with forward three-dimensional (3D) conformal planning. However, the common use of IMRT has introduced several new challenges. The potentially high degree of modulation in IMRT beams risks the loss of some advantages of 3D planning, such as excellent target coverage and high delivery efficiency. Previous attempts to reduce beam complexity by smoothing often result in plan degradation because the smoothing algorithm cannot distinguish between areas of desirable and undesirable modulation. The purpose of this work is to introduce and evaluate adaptive diffusion smoothing (ADS), a novel procedure designed to preferentially reduce IMRT beam complexity. In this method, a discrete diffusion equation is used to smooth IMRT beams using diffusion coefficients, automatically defined for each beamlet, that dictate the degree of smoothing allowed for each beamlet. This yields a method that can distinguish between areas of desirable and undesirable modulation. The ADS method has been incorporated into our optimization system as a weighted cost function penalty, with two diffusion coefficient definitions designed to promote: (1) uniform smoothing everywhere or (2) smoothing based on cost function gradients with respect to the plan beamlet intensities. The ADS method (with both coefficient types) has been tested in a phantom and in two clinical examples (prostate and head/neck). Both types of diffusion coefficients produce plans with reduced modulation and minimal dosimetric impact, but the cost function gradient-based coefficients show more potential for reducing beam modulation without affecting dosimetric plan quality. In summary, adaptive diffusion smoothing is a promising tool for ensuring that only the necessary amount of beam modulation is used, promoting more efficient and accurate IMRT planning, QA, and delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Highly Reproducible Bolus Immobilization Technique for the Treatment of Scalp Malignancies

Radiation treatment of scalp malignancies can be a challenge due to the multiple curved surfaces to which homogenous dose must be delivered. The most readily available techniques utilize linear accelerator-based technique of opposed lateral electron field abutting opposed lateral photon field with central blocking. Bolus material is used to achieve adequate skin dose. Although plans to add bolus material often occur in the virtual setting during treatment planning, the practical aspects of reproducibly maintain the bolus material along curved surfaces during the day-to-day patient setup can be a challenge. We present a case of a patient with squamous cell carcinoma of the scalp with neck node involvement treated with surgery followed by adjuvant radiotherapy. We demonstrate a unique immobilization technique that maintains the bolus material on the aquaplast mesh adherent to the patient's scalp as well as the neck. TomoTherapy with daily megavoltage computed tomography (CT) scan was utilized to verify the daily bolus position. We were able to maintain a 95% reproducibility rate. This technique reliably maintains the bolus material on the desired locations with minimum adjustments and manipulation by the therapist and is a technique that can be universally adapatable for conventional radiotherapy or intensity modulated radiation therapy (IMRT) techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗