Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Reducing the Uncertainties in Direct Aerosol Radiative Forcing

Airborne particles, which include desert and soil dust, wildfire smoke, sea salt, volcanic ash, black carbon, natural and anthropogenic sulfate, nitrate, and organic aerosol, affect Earth's climate, in part by reflecting and absorbing sunlight. This paper reviews current status, and evaluates future prospects for reducing the uncertainty aerosols contribute to the energy budget of Earth, which at present represents a leading factor limiting the quality of climate predictions. Information from satellites is critical for this work, because they provide frequent, global coverage of the diverse and variable atmospheric aerosol load. Both aerosol amount and type must be determined. Satellites are very close to measuring aerosol amount at the level-of-accuracy needed, but aerosol type, especially how bright the airborne particles are, cannot be constrained adequately by current techniques. However, satellite instruments can map out aerosol air mass type, which is a qualitative classification rather than a quantitative measurement, and targeted suborbital measurements can provide the required particle property detail. So combining satellite and suborbital measurements, and then using this combination to constrain climate models, will produce a major advance in climate prediction.

Kahn, Ralph A.↗

Chromium Vaporization Reduction by Nickel Coatings For SOEC Interconnect Materials

The vaporization of Cr-rich volatile species from interconnect materials is a major source of degradation that limits the lifetime of planar solid oxide devices systems with metallic interconnects, including Solid Oxide Electrolysis Cells, or SOECs. Some metallic coatings (Ni, Co, and Cu) significantly reduce the Cr release from interconnects and slow down the oxide scale growth on the steel substrate. To shed additional light upon the mechanisms of such protection and find a suitable coating material for ferritic stainless steel materials, we used a combination of first-principles calculations, thermodynamics, and diffusion modeling to investigate which factors determine the quality of the Ni metallic coating at stainless steel interconnector. We found that the Cr migration in Ni coating is determined by a delicate combination of the nickel oxidation, Cr diffusion, and phase transformation processes. Although the formation of Cr2O3 oxide is more exothermic than that of NiO, the kinetic rate of the chromia formation in the coating layer and its surface is significantly reduced by the low mobility of Cr in nickel oxide and in NiCr2O4 spinel. These results are in a good agreement with diffusion modeling for Cr diffusion through Ni coating layer on the ferritic 441 steel substrate.

99 GENERAL AND MISCELLANEOUS↗

Random mask optimization for fast neutron coded aperture imaging

In coded aperture imaging, one of the most important factors determining the quality of reconstructed images is the choice of mask/aperture pattern. In many applications, uniformly redundant arrays (URAs) are widely accepted as the optimal mask pattern. Under ideal conditions, thin and highly opaque masks, URA patterns are mathematically constructed to provide artifact-free reconstruction however, the number of URAs for a chosen number of mask elements is limited and when highly penetrating particles such as fast neutrons and high-energy gamma-rays are being imaged, the optimum is seldom achieved. In this case more robust mask patterns that provide better reconstructed image quality may exist. Through the use of heuristic optimization methods and maximum likelihood expectation maximization (MLEM) image reconstruction, we show that for both point and extended neutron sources a random mask pattern can be optimized to provide better image quality than that of a URA.

McMillan, Kyle↗

Correlation approach for quality assurance of additive manufactured parts based on optical metrology

Surface topography and surface finish are two significant factors for evaluating the quality of products in additive manufacturing (AM). AM parts are fabricated layer by layer, which is quite different from traditional formative or subtractive methods. Despite rapid progress in additive manufacturing and associated optical metrology for quality control and in-situ monitoring, limited research has been conducted to investigate the reliability of 3D surface measurement data. The surface topologies scanned by multiple optical systems demonstrated significant differences due to varying sampling mechanisms, resolutions, system noises, etc. The 3D datasets should be trustworthy in order to extract parameters for quality assurance or feedback control from 3D surface measurements. In this paper, we set up new standards to evaluate the reliability of 3D surface measurement data and analyze the variation in the topographical profile. In this study, two non-contact optical methods based on Focus Variation Microscopy (FVM) and Structured Light System (SLS) were adopted to measure the surface topography of the target components. The two optical metrology systems generated two entirely different point cloud datasets. Statistical methods were applied to test the difference between the data obtained from the two systems. By using a data analytics approach for comparison, it was found that the surface roughness estimated from the point cloud data sets of FVM and SLS has no significant difference, though the point cloud data sets were completely different. This paper provides standard validation approach to evaluate the plausibility of metrology data from in-situ real-time surface analysis for process planning of AM.

36 MATERIALS SCIENCE↗

Ionization chamber gradient effects in nonstandard beam configurations

Purpose: For the purpose of nonstandard beam reference dosimetry, the current concept of reporting absorbed dose at a point in water located at a representative position in the chamber volume is investigated in detail. As new nonstandard beam reference dosimetry protocols are under development, an evaluation of the role played by the definition of point of measurement could lead to conceptual improvements prior to establishing measurement procedures. Methods: The present study uses the current definition of reporting absorbed dose to calculate ionization chamber perturbation factors for two cylindrical chamber models (Exradin A12 and A14) using the Monte Carlo method. The EGSnrc based user-code EGS lowbar chamber is used to calculate chamber dose responses of 14 IMRT beams chosen to cause considerable dose gradients over the chamber volume as previously used by Bouchard and Seuntjens [''Ionization chamber-based reference dosimetry of intensity modulated radiation beams,'' Med. Phys. 31(9), 2454-5465 (2004)]. Results: The study shows conclusively the relative importance of each physical effect involved in the nonstandard beam correction factors of 14 IMRT beams. Of all correction factors involved in the dosimetry of the beams studied, the gradient perturbation correction factor has the highest magnitude, on average, 11% higher compared to reference conditions for the Exradin A12 chamber and about 5% higher for the Extradin A14 chamber. Other perturbation correction factors (i.e., P{sub wall}, P{sub stem}, and P{sub cel}) are, on average, less than 0.8% different from reference conditions for the chambers and beams studied. The current approach of reporting measured absorbed dose at a point in water coinciding with the location of the centroid of the chamber is the main factor responsible for large correction factors in nonstandard beam deliveries (e.g., intensity modulated radiation therapy) reported in literature. Conclusions: To reduce or eliminate the magnitude of perturbation correction factors in nonstandard beam reference dosimetry, two possible ways to report absorbed dose are suggested: (1) Reporting average dose to the sensitive volume of the chamber filled with water, combined with removing the reference field implicit gradient effect when measuring output factors, and (2) reporting average dose to the chamber itself during output factor verifications. The first option could be adopted if clinical beam correction factors are negligible. The second option could simplify quality assurance procedures when correction factors are not negligible and have to be calculated using Monte Carlo simulations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Weak data do not make a free lunch, only a cheap meal

Refinement and analysis of four structures with various data resolution cutoffs suggests that at present there are no reliable criteria for judging the diffraction data resolution limit and the condition I/σ(I) = 2.0 is reasonable. However, extending the limit by about 0.2 Å beyond the resolution defined by this threshold does not deteriorate the quality of refined structures and in some cases may be beneficial. Four data sets were processed at resolutions significantly exceeding the criteria traditionally used for estimating the diffraction data resolution limit. The analysis of these data and the corresponding model-quality indicators suggests that the criteria of resolution limits widely adopted in the past may be somewhat conservative. Various parameters, such as R{sub merge} and I/σ(I), optical resolution and the correlation coefficients CC{sub 1/2} and CC*, can be used for judging the internal data quality, whereas the reliability factors R and R{sub free} as well as the maximum-likelihood target values and real-space map correlation coefficients can be used to estimate the agreement between the data and the refined model. However, none of these criteria provide a reliable estimate of the data resolution cutoff limit. The analysis suggests that extension of the maximum resolution by about 0.2 Å beyond the currently adopted limit where the I/σ(I) value drops to 2.0 does not degrade the quality of the refined structural models, but may sometimes be advantageous. Such an extension may be particularly beneficial for significantly anisotropic diffraction. Extension of the maximum resolution at the stage of data collection and structure refinement is cheap in terms of the required effort and is definitely more advisable than accepting a too conservative resolution cutoff, which is unfortunately quite frequent among the crystal structures deposited in the Protein Data Bank.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tunable Q-Factor Gas-Filled RF Cavity

Fermilab is the main institution to produce the most powerful and wide-spectrum neutrino beam. From that respective, a radiation robust beam diagnostic system is a critical element in order to maintain the quality of the neutrino beam. Within this context, a novel radiation-resistive beam profile monitor based on a gas-filled RF cavity has been proposed. The goal of this measurement is to study a tunable Q-factor RF cavity to determine the accuracy of the RF signal as a function of the quality factor. Specifically, the measurement error of the Q-factor in the RF calibration is investigated. Then, the RF system will be improved to minimize signal error.

43 PARTICLE ACCELERATORS↗

Investigating Powder Spreading Dynamics in Additive Manufacturing Processes by In-situ High-speed X-ray Imaging

The quality of the powder bed is known to be one of the main factors that influence the quality of the part being manufactured by powderbed- based additive manufacturing processes. For example, in the laser powder bed fusion process, it has been demonstrated that improving the powder bed density and homogeneity improves the final quality of the part. Understanding powder spreading dynamics in the powder-bed-based additive manufacturing processes is critical for designing spreading structures and spreading parameters, identifying defect formation mechanisms in the powder bed, and guiding the design of optimized feedstock powders. Extensive efforts have been devoted to understand the fundamental mechanism of the powder flow and spreading process. Various powder flow testers were used to study the flow behavior of powders used in additive manufacturing. However, the powder flow conditions in flow meters are different from those in real additive manufacturing conditions. Models have also been developed to simulate and study the spreading process. The discrete element method (DEM) is currently the main tool for computationally simulating the spreading process. However, these models are based on many physical assumptions. Visible light cameras have been used recently to conduct in-situ study of powder spreading in additive manufacturing. Due to the limited resolution and penetration depth of visible light, it is extremely difficulty to study the particle-scale powder spreading dynamics. Here, to overcome the challenges of studying powder spreading dynamics under real additive manufacturing conditions, we developed an experimental approach to study the particle-scale powder spreading process with high spatial and temporal resolution using the high-speed high-energy X-ray imaging facility at beamline 32-ID-B of the APS. Figure 1 shows an overview of the research setup. It is composed of a vacuum chamber (building environment), an automatic powder spreading system, a laser system, an X-ray source (X-ray outlet), and an X-ray detection/imaging system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Appalachian Basin Play Fairway Analysis: Revised 2016 Combined Risk Factor Analysis

This submission contains information used to compute the combined risk factors for deep geothermal energy opportunities in the Appalachian Basin, in the context of a the Play Fairway Analysis project. The risk factors are sedimentary rock reservoir quality, thermal resource quality, potential for induced seismicity, and utilization for direct-use heating of neighborhoods. The methods used to combine the risk factors included taking the average, the geometric mean, and the minimum of the four risk factors. Combined risk maps are provided for three different sedimentary rock reservoir metrics. Combined risk maps are also provided for the three geologic risk factors alone (thermal, reservoir, and seismic), and for the three risk factors that exclude reservoir quality (utilization, seismicity, and thermal qualities). The 2015 data submission should be visited to obtain associated shapefiles, which include: 1) definition of the High and Medium priority play fairways (Inner_Fairway, and Outer_Fairway), 2) definition of the US Census Places (usCensusPlaces), 3) places (cities) of interest in the region (Places_of_Interest) identified as geothermal play fairways, 4) the point centers of the raster cells (Raster_Center_Locations), and 5) locations of industries and special-use communities (e.g., colleges and military bases) identified as low temperature heat users (Industries). The 2015 submission also includes: 1) a methodology memo that explains how the risk factors were combined (GPFA-AB_combining_risk_factors.pdf), 2) the earthquake-based seismic risk map, and 3) supporting information with details of the calculations or processing used in generating these data files. More details on each file are given in the spreadsheet "list_of_contents.xlsx" in the folder "Supporting_Information". Code used to calculate values is available at https://github.com/calvinwhealton/geothermal_pfa under the folder "combining_metrics". Note that the 2016 code is currently under the branch named "combining_metrics_2016" in the folder called "combining_metrics". This branch may be merged with the master branch in the future. Many files contained within this submission update and replace the indicated files contained in: Cornell University. (2015). Risk Factor Analysis in Low-Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB) [data set]. Retrieved from https://gdr.openei.org/submissions/622. doi:10.15121/1261942

15 GEOTHERMAL ENERGY↗

SU-D-209-05: Sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to Procedural Factors in Fluoroscopy

Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.

60 APPLIED LIFE SCIENCES↗

GPFA-AB_Phase1RiskAnalysisTask5DataUpload

This submission contains information used to compute the risk factors for the GPFA-AB project (DE-EE0006726). The risk factors are natural reservoir quality, thermal resource quality, potential for induced seismicity, and utilization. The methods used to combine the risk factors included taking the product, sum, and minimum of the four risk factors. The files are divided into images, rasters, shapefiles, and supporting information. The image files show what the raster and shapefiles should look like. The raster files contain the input risk factors, calculation of the scaled risk factors, and calculation of the combined risk factors. The shapefiles include definition of the fairways, definition of the US Census Places, the center of the raster cells, and locations of industries. Supporting information contains details of the calculations or processing used in generating the files. An image of the raster will have the same name except *.png as the file ending instead of *.tif. Images with “fairways” or “industries” added to the name are composed of a raster with the relevant shapefile added. The file About_GPFA-AB_Phase1RiskAnalysisTask5DataUpload.pdf contains information the citation, special use considerations, authorship, etc. More details on each file are given in the spreadsheet “list_of_contents.csv” in the folder “SupportingInfo”. Code used to calculate values is available at https://github.com/calvinwhealton/geothermal_pfa under the folder “combining_metrics”.

15 GEOTHERMAL ENERGY↗

Risk Factor Analysis in Low-Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB)

This submission contains information used to compute the risk factors for the GPFA-AB project. The risk factors are natural reservoir quality, thermal resource quality, potential for induced seismicity, and utilization. The methods used to combine the risk factors included taking the product, sum, and minimum of the four risk factors. The files are divided into images, rasters, shapefiles, and supporting information. The image files show what the raster and shapefiles should look like. The raster files contain the input risk factors, calculation of the scaled risk factors, and calculation of the combined risk factors. The shapefiles include definition of the fairways, definition of the US Census Places, the center of the raster cells, and locations of industries. Supporting information contains details of the calculations or processing used in generating the files. An image of the raster will have the same name except *.png as the file ending instead of *.tif. Images with 'fairways' or 'industries' added to the name are composed of a raster with the relevant shapefile added. The file About_GPFA-AB_Phase1RiskAnalysisTask5DataUpload.pdf contains information the citation, special use considerations, authorship, etc. ***See 'GPFA-AB.zip' at bottom for compressed and organized version of the files associated with this submission*** **More details (including location) on each file are given in the spreadsheet 'list_of_contents.csv' in the folder 'SupportingInfo'** Code used to calculate values is available: https://github.com/calvinwhealton/geothermal_pfa under the folder 'combining_metrics' - *See link below*

15 GEOTHERMAL ENERGY↗

Diamonds in the rough: a strong case for the inclusion of weak-intensity X-ray diffraction data

Here, new evidence is provided to show that the inclusion of weak-intensity, high-resolution X-ray diffraction data helps to improve the quality of experimental phases by imposing proper constraints on electron-density models during noncrystallographic symmetry averaging. Overwhelming evidence exists to show that the inclusion of weak-intensity, high-resolution X-ray diffraction data helps improve the refinement of atomic models by imposing strong constraints on individual and overall temperature B factors and thus the quality of crystal structures. Some researchers consider these data to be of little value and opt to discard them during data processing, particularly at medium and low resolution, at which individual B factors of atomic models cannot be refined. Here, new evidence is provided to show that the inclusion of these data helps to improve the quality of experimental phases by imposing proper constraints on electron-density models during noncrystallographic symmetry (NCS) averaging. Using electron-density correlation coefficients as criteria, the resolution of data has successfully been extended from 3.1 to 2.5 Å resolution with redundancy-independent merging R factors from below 100% to about 310%. It is further demonstrated that phase information can be fully extracted from observed amplitudes through de novo NCS averaging. Averaging starts with uniform density inside double-shelled spherical masks and NCS matrices that are derived from bound heavy-atom clusters at the vertices of cuboctahedrally symmetric protein particles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy

Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

60 APPLIED LIFE SCIENCES↗

Aging impairs the osteocytic regulation of collagen integrity and bone quality

Poor bone quality is a major factor in skeletal fragility in elderly individuals. The molecular mechanisms that establish and maintain bone quality, independent of bone mass, are unknown but are thought to be primarily determined by osteocytes. We hypothesize that the age-related decline in bone quality results from the suppression of osteocyte perilacunar/canalicular remodeling (PLR), which maintains bone material properties. We examined bones from young and aged mice with osteocyte-intrinsic repression of TGFβ signaling (TβRII ocy–/– ) that suppresses PLR. The control aged bone displayed decreased TGFβ signaling and PLR, but aging did not worsen the existing PLR suppression in male TβRII ocy–/– bone. This relationship impacted the behavior of collagen material at the nanoscale and tissue scale in macromechanical tests. The effects of age on bone mass, density, and mineral material behavior were independent of osteocytic TGFβ. We determined that the decline in bone quality with age arises from the loss of osteocyte function and the loss of TGFβ-dependent maintenance of collagen integrity.

59 BASIC BIOLOGICAL SCIENCES↗

Wind resource quality affected by high levels of renewables

For solar photovoltaic (PV) and wind resources, the capacity factor is an important parameter describing the quality of the resource. As the share of variable renewable resources (such as PV and wind) on the electric system is increasing, so does curtailment (and the fraction of time when it cannot be avoided). At high levels of renewable generation, curtailments effectively change the practical measure of resource quality from capacity factor to the incremental capacity factor. The latter accounts only for generation during hours of no curtailment and is directly connected with the marginal capital cost of renewable generators for a given level of renewable generation during the year. The Western U.S. wind generation is analyzed hourly for a system with 75% of annual generation from wind, and it is found that the value for the system of resources with equal capacity factors can vary by a factor of 2, which highlights the importance of using the incremental capacity factor instead. Finally, the effect is expected to be more pronounced in smaller geographic areas (or when transmission limitations imposed) and less pronounced at lower levels of renewable energy in the system with less curtailment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Extending the limits of powder diffraction analysis: diffraction parameter space, occupancy defects, and atomic form factors

Although the determination of site occupancies is often a major goal in Rietveld refinement studies, the accurate refinement of site occupancies is exceptionally challenging due to the many correlations and systematic errors that have a hidden impact on the final refined occupancy parameters. Through the comparison of results independently obtained from neutron and synchrotron powder diffraction, improved approaches capable of detecting occupancy defects with an exceptional sensitivity of 0.1% (absolute) in the class of layered NMC Li-ion battery cathode materials have been developed. A new method of visualizing the diffraction parameter space associated with crystallographic site scattering power through the use of f* diagrams is described and this method is broadly applicable to ternary compounds. The f* diagrams allow the global minimum fit to be easily identified and also permit a robust determination of the number and type of occupancy defects within a structure. Through a comparison of neutron and X-ray diffraction results, a systematic error in the synchrotron results was identified using f* diagrams for a series of NMC compounds. Using neutron diffraction data as a reference, this error was shown to specifically result from problems associated with the neutral oxygen X-ray atomic form factor and could be eliminated by using the ionic O 2- form factor for this anion while retaining the neutral form factors for cationic species. The f* diagram method offers a new opportunity to experimentally assess the quality of atomic form factors through powder diffraction studies on chemically related multi-component compounds.

25 ENERGY STORAGE↗