Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pv”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

The Impact of a Faster Thermal Cycling Profile on PV Cell Interconnect Cycles to Failure

The thermal cycling tests used in the photovoltaic industry are slow, requiring over a month for 200 cycles and five months for 800 cycles. A faster alternative would reduce the cost of delay for module qualification. This study investigates the correlation between a baseline thermal cycling profile and profiles that are three and six times faster. Interconnect failure data for each profile was gathered across eight splits of varying material combinations. Models were applied to the failure data and factors which impacted interconnect lifetime were identified. Here, the results show that more cycles were required in the faster profiles for equivalency to the baseline profile. Furthermore, the equivalent number of cycles varied by a factor of two across the splits. Despite these limitations, the faster profiles offer substantial qualification time savings if the underlying failure mechanisms are understood.

14 SOLAR ENERGY↗

UV-Fluorescence Imaging of Silicon PV Modules After Outdoor Aging and Accelerated Stress Testing

Fast, non-destructive, outdoor-compatible methods for photovoltaic module characterization are essential for monitoring module quality without disrupting energy production. UV-fluorescence (UVF) imaging of the encapsulant layer can be used for crack detection in the field. We show that UVF patterns vary widely between modules and types of applied stress. We propose that combining accelerated stress testing (e.g. thermal cycling and damp heat) with field investigations can help build understanding of different types of UVF, which are formed and subsequently quenched at varying rates. Ultimately, such understanding could enable estimating when cracks were formed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Interfacial Characterization of Positive Bias Voltage Degradation in PV Modules

Degradation from high system voltage is a prevailing failure mode in fielded photovoltaic modules, and the degradation mechanism is inherently dependent on the bias polarity. Here we report the effects of positive bias. Modules under positive bias demonstrated a significant photocurrent loss caused by two routes. First, delamination and discoloration of the silicon nitride layer, leading to optical loss determined by reflectance measurements. Second, chemical discoloration of the cell gridlines and encapsulant (EVA), which is linked to an electrochemical reaction at the silver electrodes. Chemical compositional analysis using X-ray photoemission spectroscopy demonstrated that the discoloration is attributed to Ag 2 S and/or Ag 2 O. Evidence of Ag ion migration from the cell grid into the encapsulant is observed after shallow depth profiling on the EVA surface. However, Ag was not detected at the EVA/glass interface, inferring limited Ag ion transport through the EVA. The source of sulfur is believed to be ambient air, which diffused into the module through the breathable backsheet.

characterization↗

Diagnosis of PV Cell Passivation Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on the cell ("AR c corrosion") was previously observed in studies using hot-humid test conditions with external high voltage (HV) bias. Because AR c corrosion is not well understood, mini-modules (MiMos) were examined in a comparative experiment using PERC and PERT as well as legacy Al-BSF cells. For separate MiMos with the cell circuit electrical at +1500 V, -1500 V, or unbiased "V oc", test conditions in the comparative study included 60degrees C/60% RH for 96 h, as in IEC TS 62804-1; 70degrees C/70%RH for 200 h; and 85degrees C/85% RH for 200 h. Characterizations at each read point included: camera and electroluminescence (EL) imaging, colorimetry, and I-V curve tracing. Characterizations at the final read point included: SunsVoc; spatially mapping external quantum efficiency (EQE); high resolution: photoluminescence (PL), EL, and dark lock-in thermographic (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos (stepped HV aging) and full-sized modules (outdoor aging) from previous studies. AR c corrosion was specifically observed for the glass/encapsulant/cell side of +1500 V (HV+) stressed MiMos, where appearance, color, and reflectance were the characteristics most distinguished relative to simultaneously occurring degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to silicon oxide or hydrous silica, preferentially occurring at the edges and tips of the pyramidal textured cell surface.

aging↗

A CHIL Validation of Machine Learning-Assisted Methods for Real-Time Controls of Solar PV for Grid Services

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been proposed; however, these technologies lack comprehensive validation under real-world application scenarios. This paper addresses this gap by designing and developing a controller-hardware-in-the-loop framework to evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. Simulation results indicate the superior performance of an ML-based approach compared to the conventional reference-control grouping-based approach, showcasing its potential to support grid stability and operational efficiency.

closed-loop validation↗

Studying the Impact of Distributed Solar PV on Power Systems Using Integrated Transmission and Distribution Models

Rapid growth of distributed energy resources has prompted increasing interest in integrated Transmission (T) and Distribution (D) modeling. This paper presents the results of a distributed generation from solar photovoltaics (DGPV) impact assessment study that was performed using a synthetic T &D model. The primary objective of the study was to present a new approach for DGPV impact assessment, where along with detailed models of transmission and distribution networks, consumer loads were modeled using the physics of end-use equipment, and DGPV was geographically dispersed and connected to the secondary distribution networks. The study highlights (i) how a lack of DGPV forecasting can increase the Area Control Error (ACE) at the transmission level for high penetration levels; and (ii) how capturing transmission voltage changes using integrated T &D can change simulated distribution voltage profiles and voltage regulator operations between integrated T &D and distribution-only simulations.

14 SOLAR ENERGY↗

FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration

Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. Furthermore, these contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.

14 SOLAR ENERGY↗