Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines

Cubic spline interpolation is able to recover temporally and spectrally resolved soft x-ray flux from an array of K-edge filtered x-ray diodes without the need for a priori assumptions about the spectrum or the geometry of the emitting volume. The mathematics of the cubic spline interpolation is discussed in detail. The analytic nature of the cubic spline solution allows for analytical error propagation, and the method of calculating the error for radiation temperature, spectral power, and confidence intervals of the unfolded spectrally resolved flux is explained. An unfold of a blackbody model demonstrates the accuracy of the cubic spline unfold. Tests of cubic spline performance using spectrally convolved detailed atomic model simulation results have been performed to measure the method's ability to conserve spectral power to within a factor of 2 or better in line-dominated regimes. The unfold is also demonstrated to work when information from the x-ray diode array is limited due to high signal-to-noise ratios or lack of signal due to over-attenuation or over-filtration of the x-ray diode signal. Here, the robustness of the unfold with respect to background subtraction and raw signal processing, signal alignment between diode traces, limited signal information, and initial conditions is discussed. Results from an example analysis of a halfraum drive are presented to demonstrate the capabilities of the unfold in comparison with previously established methods.

47 OTHER INSTRUMENTATION↗

NUBOW-3D Demonstration on LFR: Final CRADA Report

The NUBOW-3D software was developed to assist in designing a core restraint system for sodium-cooled fast spectrum reactors. Originally conceived during the FFTF design activities, the United States has been a proponent of limited free bow reactor design ever since to improve safety performance. In fast spectrum reactors, successful safety performance during reactor transients requires favorable reactivity feedback that leads to safe power stabilization or even natural system shutdown. In fast spectrum reactors, one key mechanism that designers use to improve the performance is to make thermal expansion inject negative feedback into the reactor system. While most fast reactor systems generally have a negative reactivity response to geometric expansion, the NUBOW-3D software allows the designers to better explore the impact on reactivity and optimize the system to maximize its impact.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine learning for reactor power monitoring with limited labeled data

Real-time reactor power monitoring is critical for a variety of nuclear applications, spanning safety, security, operations, and maintenance. While machine learning methods have shown promise in monitoring reactor power levels, there is limited research on their efficacy in label-starved environments. The goal of this work is to assess the feasibility of classifying nuclear reactor power level using multisource data in scenarios with limited labels. Data were collected using low-resolution multisensors at four nuclear reactor facilities: two large research reactors and two TRIGA reactors. Within each pair, one reactor dataset served as the source and the other as the target in a transfer learning paradigm. Twenty-three supervised models were trained on labeled sequences of magnetic field and acceleration data from each of the target sites. Self-learning and transfer learning methods were applied to the top performing models to assess their classification performance with increasing amounts of labeled data. While reactor power level classification was achieved with a Matthews Correlation Coefficient of up to 0.739 ± 0.003 and 0.622 ± 0.009 with only 400 sequences per power state for the large research reactor and TRIGA target sites, respectively, self-learning and transfer learning leveraging source site data did not improve target classification performance. These findings suggest that alternative methods, such as higher sensitivity sensors, digital twins, or the use of physics-informed models, are required to enable high-performance classification in machine learning approaches to reactor monitoring with a dearth of target ground truth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verifying raytracing/Fokker–Planck lower-hybrid current drive predictions with self-consistent full-wave/Fokker–Planck simulations

Raytracing/Fokker–Planck (FP) simulations used to model lower-hybrid current drive (LHCD) often fail to reproduce experimental results, particularly when LHCD is weakly damped. A proposed reason for this discrepancy is the lack of ‘full-wave’ effects, such as diffraction and interference, in raytracing simulations and the breakdown of the raytracing approximation. Previous studies of LHCD using non-Maxwellian full-wave/FP simulations have been performed, but these simulations were not self-consistent and enforced power conservation between the FP and full-wave code using a numerical rescaling factor. Here, we have created a fully self-consistent full-wave/FP model for LHCD that is automatically power conserving. This was accomplished by coupling an overhauled version of the non-Maxwellian TORLH full-wave solver and the CQL3D FP code using the Integrated Plasma Simulator. We performed converged full-wave/FP simulations of Alcator C-Mod discharges and compared them with raytracing. We found that excellent agreement in the power deposition profiles from raytracing and TORLH could be obtained, however, TORLH had somewhat lower current drive efficiency and broader power deposition profiles in some cases. This discrepancy appears to be a result of numerical limitations present in the TORLH model and a small amount of diffractional broadening of the TORLH wave spectrum. Our results suggest full-wave simulation of LHCD is likely not necessary as diffraction and interference represented only a small correction that could not account for the differences between simulations and experiment.

Physics↗

Rapid QSTS Simulations for High-Resolution Comprehensive Assessment of Distributed PV

The rapid increase in penetration of distributed energy resources on the electric power distribution system has created a need for more comprehensive interconnection modeling and impact analysis. Unlike conventional scenario-based studies, quasi-static time-series (QSTS) simulations can realistically model time-dependent voltage controllers and the diversity of potential impacts that can occur at different times of year. However, to accurately model a distribution system with all its controllable devices, a yearlong simulation at 1-second resolution is often required, which could take conventional computers a computational time of 10 to 120 hours when an actual unbalanced distribution feeder is modeled. This computational burden is a clear limitation to the adoption of QSTS simulations in interconnection studies and for determining optimal control solutions for utility operations. The solutions we developed include accurate and computationally efficient QSTS methods that could be implemented in existing open-source and commercial software used by utilities and the development of methods to create high-resolution proxy data sets. This project demonstrated multiple pathways for speeding up the QSTS computation using new and innovative methods for advanced time-series analysis, faster power flow solvers, parallel processing of power flow solutions and circuit reduction. The target performance level for this project was achieved with year-long high-resolution time series solutions run in less than 5 minutes within an acceptable error.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Evaluation of the Single-Phase Shift and Extended-Phase Shift Control for Isolated DC-DC Converter

Abstract: This paper presents a comparative evaluation of the Single-Phase Shift (SPS) and Extended-Phase Shift (EPS) controls for the isolated DC-DC Converter. The analysis is based on the power regulation range, flexibility of operation, current stress on power devices, system efficiency while focusing on the issue of backflow power, control complexity, design and implementation overhead, and stability of the entire system. It is also examined how the backflow influences power circulation and increases current stress. Here, the Dual Active Bridge (DAB) Converter is employed to assess the performance of the control methods. Compared to SPS control, EPS offers a wider power regulation range, greater flexibility, lower current stress, and better system efficiency. However, EPS has increased control complexity, design and implementation overhead, and often requires sophisticated feedback control loops. The comparison is made through mathematical modeling of power transfer, backflow, and current stress. Simulation results validate the comparative analysis presented.

Amir, Aamir [The University of Alabama (UA)]↗

A Sustainable Wind–Biogas Hybrid System for Remote Areas in Jordan: A Case Study of Mobile Hospital for a Zaatari Syrian Refugee Camp

Access to reliable and sustainable energy in remote areas remains a pressing global challenge, significantly affecting economic development and the quality of life. This study focuses on the implementation of fully off-grid wind–biogas hybrid power systems to address this issue, with a focus on remote healthcare camp facilities. This paper investigates the performance of a hybrid renewable energy system within the context of one of Jordan’s northern remote areas, the Zaatari Syrian Refugee Camp, assessing its efficiency and environmental impact by taking the Zaatari hospital as the case study. Simulations were conducted to evaluate system components, including wind turbines, biogas generators, and diesel generators. A comprehensive evaluation was conducted, encompassing both the operational efficiency of the system and its impact on the environment. This study also considered various scenarios (SC#), including grid availability and autonomy levels, to optimize system configurations. The techno-economic assessment employed the levelized cost of energy (LCOE) as a key performance indicator, and sensitivity analyses explored the impact of diesel costs and wind power fluctuations on the system. Additionally, environmental assessment was conducted to evaluate the environmental effects of hybrid systems, with a specific focus on reducing greenhouse gas emissions. This investigation involved an examination of emissions in three different scenarios. The results indicate that the lowest LCOE that could be achieved was 0.0734 USD/kWh in SC#1 with 72.42% autonomy, whereas achieving 100% autonomy increased the LCOE to 0.1756 USD/kWh. Additionally, the results reveal that in scenarios SC#2 and SC#3, which have a higher proportion of diesel generator usage, there were elevated levels of NO x and CO 2 emissions. Conversely, in SC#1, which lacks diesel generators, emissions were notably lower. The proposed hybrid system demonstrates its potential to provide a reliable energy supply to healthcare facilities in remote regions, emphasizing both economic feasibility and environmental benefits. These findings contribute to informed decision making for sustainable energy solutions in similar contexts, promoting healthcare accessibility and environmental sustainability.

09 BIOMASS FUELS↗

Analysis of the neutral fluxes in the divertor region of Wendelstein 7-X under attached and detached conditions using EMC3-EIRENE

Abstract This paper analyzes the neutral fluxes in the divertor region of the W7-X standard configuration for different input powers, both under attached and detached conditions. The performed analysis is conducted through EMC3-EIRENE simulations. They show the importance of the horizontal divertor to generate neutrals, and resolve the neutral plugging in the divertor region. Simulations of detached cases show a decrease in the number of generated neutrals compared to the attached simulations, in addition to a higher fraction of the ion flux arriving on the baffles during detachment. As the ionization takes place further inside the plasma during detachment, a larger percentage of the generated neutral particles leave the divertor as neutrals. The leakage in the poloidal and toroidal direction increases, just as the fraction of collected particles at the pumping gap. The fraction of pumped particles increases with a factor two, but stays below one percent. This demonstrates that detachment with the current target geometry, although it improves the power exhaust, is not yet leading to an increased particle exhaust.

Physics↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Levelized Cost of Energy Comparison of Floating Wind Farms With and Without Shared Anchors

As part of the Innovative Deep-Water Mooring Systems for Floating Wind Farms (DeepFarm) R&D project, led by Principle Power Inc., the National Renewable Energy Laboratory (NREL) performed an LCOE analysis to compare the changes in LCOE between floating wind farms with individual anchors versus shared anchors. This report presents a comparative analysis of the LCOE of two different wind farms with different mooring systems: one with taut mooring lines each connected to individual suction pile anchors, and one with taut mooring lines connected to shared anchors. A brief description of the methodology employed to conduct the LCOE comparison is given, including the underlying assumptions. Then, results are presented with a compilation of key findings.

16 TIDAL AND WAVE POWER↗

Optimization of a Packed Particle Magnetocaloric Refrigerator: A Combined Experimental and Theoretical Study

Magnetocaloric refrigeration has strong potential towards achieving high efficiency hydrogen liquefaction. Optimising parameters such as particle size and operating cycles can have a significant impact on liquefaction performance. Here, this work reports on a room temperature magnetocaloric refrigeration prototype designed with helium as the heat transfer fluid and packed particle Gd 0.8875 Ce 0.1025 Si 0.84 Cr 0.19 as the refrigerant. The temperature spans and cooling power with three different particle sizes at two different operating cycles were measured. A maximum temperature span of 16.7 K and a maximum cooling power of 8.6 W·kg –1 were obtained. Reduction of performance in the faster cycle was observed in larger particles due to insufficient thermal diffusion time and its implications for cryogenic temperatures are discussed. A numerical model was developed based on the experimentally observed variation of the temperature span and cooling power with particle size and cycle duration. This model was then used to study the competing effects of viscous dissipation and thermal diffusion for different particle sizes and cycle durations.

08 HYDROGEN↗

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2025

A summary of NLR's stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, capability upgrades, and examples of R&D impact. 2025 brought a national focus on energy and ESIF is meeting the moment. All eyes are on data centers and domestic manufacturing and bringing the benefits of artificial intelligence to power system planning and operations. In step with national priorities, ESIF is building out capabilities that advance secure, reliable, and affordable power. ESIF hosted 190 multidisciplinary research projects, 855 high-performance computer users, and collaborated with 81 partners from industry, academia, research, and federal agencies. These research projects resulted in an AI method for detecting high-impedance faults with 90% accuracy, a grid controls demonstration in Connecticut, power quality validation of CorePower's flagship inductor, and a cybersecurity assessment of potential rogue capabilities in digitally connected energy devices. Facility infrastructure improvements enhanced the thermal research network, the SCADA system, the cyber range, power hardware-in-the-loop testing, and more. With support from the U.S Department of Energy (DOE), the ESIF laboratories continue to deliver leading solutions for secure, reliable, and affordable power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Crystalline Structure-Dependent Mechanical and Thermoelectric Performance in Ag 2 Se 1–x S x System

Self-powered wearable electronics require thermoelectric materials simultaneously with a high dimensionless figure of merit (zT) and good flexibility to convert the heat discharged by the human body into electricity. Ag 2 (S,Se)-based semiconducting materials can well satisfy these requirements, and thus, they are attracting great attention in thermoelectric society recently. Ag 2 (S,Se) crystalizes in an orthorhombic structure or monoclinic structure, depending on the detailed S/Se atomic ratio, but the relationship between its crystalline structure and mechanical/thermoelectric performance is still unclear to date. In this study, a series of Ag 2 Se 1–x S x (x = 0, 0.1, 0.2, 0.3, 0.4, and 0.45) samples were prepared and their mechanical and thermoelectric performance dependence on the crystalline structure was systematically investigated. x = 0.3 in the Ag 2 Se 1–x S x system was found to be the transition boundary between orthorhombic and monoclinic structures. Mechanical property measurement shows that the orthorhombic Ag 2 Se 1–x S x samples are brittle while the monoclinic Ag 2 Se 1–x S x samples are ductile and flexible. In addition, the orthorhombic Ag 2 Se 1–x S x samples show better electrical transport performance and higher zT than the monoclinic samples under a comparable carrier concentration, most likely due to their weaker electron-phonon interactions. This study sheds light on the further development of flexible inorganic TE materials.

36 MATERIALS SCIENCE↗

Wind turbine performance enhancement with minimal structural load penalty: A design philosophy

The performance benefits of using tip devices on wind turbines has been well-documented. However, previous studies show that adding blade tip devices such as winglets leads to a significant increase in blade root bending moment, potentially requiring structural reinforcement with cost and weight drawbacks. A new and unique design philosophy for retrofit blade tip devices for wind turbines is presented. By balancing generated aerodynamic and centrifugal loads, these devices offer an increase in power production without the need for structural reinforcement. Predicted performance and cost benefits of using retrofit blade tip devices on the National Renewable Energy Laboratory 5 MW reference wind turbine are shown. Finally, the addition of blade tip devices resulted in significant improvements in the coefficient of power (C p ) and annual energy production (AEP).

17 WIND ENERGY↗

Inventory for Crystalline Silicon Module Recycling: Cooperative Research and Development (Final Report)

A critical challenge for the continued expansion of photovoltaics (PV) is to develop technically feasible, inexpensive and environmentally friendly practices for handling and recycling modules at the end of their usable life. The National Renewable Energy Laboratory (NREL) is requested by the Electric Power Research Institute (EPRI) to collect primary data regarding the environmental performance of currently operational PV module recycling facilities in Europe. Very little has been published regarding crystalline silicon (C-Si) module recycling. Thus, much effort will be needed in direct industry outreach, collection of information and other business intelligence strategies similar to NREL's approaches for developing cost models for PV manufacturing. The goal of this work effort is to produce a detailed inventory that accounts for physical (e.g., energy, water, materials) flows through each step of a C-Si recycling process. The inventory (a life cycle inventory, or LCI) shall be designed so that it can be extended to include an accounting of costs for each process step, inputs, etc. This work effort shall leverage prior LCI data collection NREL performed for the United States Department of Energy, Solar Energy Technologies Office, under the auspices of the U.S. contribution to International Energy Agency's Photovoltaics Power Systems (PVPS) Task 12 (Environmental Health and Safety), which SETO nominated NREL to chair. The primary purpose of this work effort is to augment the prior data collection to increase the sample size of manufacturers' primary data in the LCI.

14 SOLAR ENERGY↗