Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Accurate formula for dissipative interaction in frequency modulation atomic force microscopy

Much interest has recently focused on the viscosity of nano-confined liquids. Frequency modulation atomic force microscopy (FM-AFM) is a powerful technique that can detect variations in the conservative and dissipative forces between a nanometer-scale tip and a sample surface. We now present an accurate formula to convert the dissipation power of the cantilever measured during the experiment to damping of the tip-sample system. We demonstrated the conversion of the dissipation power versus tip-sample separation curve measured using a colloidal probe cantilever on a mica surface in water to the damping curve, which showed a good agreement with the theoretical curve. Moreover, we obtained the damping curve from the dissipation power curve measured on the hydration layers on the mica surface using a nanometer-scale tip, demonstrating that the formula allows us to quantitatively measure the viscosity of a nano-confined liquid using FM-AFM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small-signal gain diagnostic measurements in a flowing CO2 pin discharge laser

Small-signal gain diagnostic measurements were conducted on closed loop, high power, carbon dioxide laser to assess the coupling between gas flow velocity and resonator saturation. Parameters investigated included optical cavity and discharge power. Results of gain measurements within and downstream of the excitation volume are presented for a laser gas composition He:N2:CO2 of 10:7:1 at 90 torr. The gain at constant discharge power was observed to be dependent upon discharge power level and time. An important result of this study is that the effects of gain swept downstream of the discharge region must be considered in the resonator design if efficient extraction of stored optical energy is desired.

Blech, R. A.↗

The enhancement of solar wind fluctuations at the proton thermal gyroradius

Average power spectra of solar wind fluctuations at frequencies up to 0.87 Hz are calculated from Ogo 5 measurements of positive ion flux. Although the general spectral trend follows the power law spectrum observed at lower frequencies, a small but statistically significant power enhancement is observed at the frequency v/2(pi)R, where v is the solar wind velocity and R is the gyroradius of proton thermal motions in the solar wind. The measured power spectrum is in rough agreement with that deduced from radio scintillation observations.

Neugebauer, M.↗

Capacitance–voltage modeling of mid-wavelength infrared nBn detectors

Capacitance–voltage measurements are a powerful technique to determine doping profiles of semiconductor pn junctions and Schottky barrier diodes. The measurements were recently extended to III-V-based mid-wavelength nBn infrared detectors, and absorber doping densities have been extracted using the widely accepted Schottky approximation, where the potential drop across the device is assumed to be across the depleting absorber layer. However, this approach is limited to when the absorber region of the nBn is under high reverse bias and thus is only able to extract the absorber region doping profile. Here, we introduce a semi-analytical model that is capable of extracting barrier dopant polarity, doping concentration, and thickness, as well as contact and absorber layer doping concentrations, all from a capacitance–voltage measurement. Rather than solely considering the potential drop across the depleting layers, it considers the potential drop across the accumulating layer as well. This negative charge accumulation occurs for the contact and absorber layers in the case of reverse and forward biases, respectively. This allows for a single model to be applied to a capacitance–voltage curve at forward and reverse biases and it can provide regions of bias where the absorber transitions from depletion to accumulation. We compare the agreement of the semianalytical model with modeling results from commercially available finite element method software and experimental capacitance–voltage data. Finally, we show that the method is consistent with the Schottky approximation of extracting absorber doping densities at high reverse bias and discuss the model's limitations.

Physics↗

Measuring the redshift of reionization with a modest array of low-frequency dipoles

The designs of the first generation of cosmological 21-cm observatories are split between single dipole experiments which integrate over a large patch of sky in order to find the global (spectral) signature of reionization, and interferometers with arcminute-scale angular resolution whose goal is to measure the 3D power spectrum of ionized regions during reionization. We examine whether intermediate scale instruments with complete Fourier (uv) coverage are capable of placing new constraints on reionization. We find that even without using a full power spectrum analysis, the global redshift of reionization, z{sub reion}, can in principle be measured from the variance in the 21-cm signal among multiple beams as a function of frequency at a roughly 1 degree angular scale. At this scale, the beam-to-beam variance in the differential brightness temperature peaks when the average neutral fraction was ∼ 50%, providing a convenient flag of z{sub reion}. We choose a low angular resolution of order 1° to exploit the physical size of the ionized regions and maximize the signal-to-noise ratio. Thermal noise, foregrounds, and instrumental effects should also be manageable at this angular scale, as long as the uv coverage is complete within the compact core required for low-resolution imaging. For example, we find that z{sub reion} can potentially be detected to within a redshift uncertainty of Δz{sub reion}∼<1 in ∼>500 hours of integration on the existing MWA prototype (with only 32 × 16 dipoles), operating at an angular resolution of ∼ 1° and a spectral resolution of 2.4 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of power spectra for tomosynthesis projections and reconstructed images

Burgess et al. [Med. Phys. 28, 419-437 (2001)] showed that the power spectrum of mammographic breast background follows a power law and that lesion detectability is affected by the power-law exponent {beta} which measures the amount of structure in the background. Following the study of Burgess et al., the authors measured and compared the power-law exponent of mammographic backgrounds in tomosynthesis projections and reconstructed slices to investigate the effect of tomosynthesis imaging on background structure. Our data set consisted of 55 patient cases. For each case, regions of interest (ROIs) were extracted from both projection images and reconstructed slices. The periodogram of each ROI was computed by taking the squared modulus of the Fourier transform of the ROI. The power-law exponent was determined for each periodogram and averaged across all ROIs extracted from all projections or reconstructed slices for each patient data set. For the projections, the mean {beta} averaged across the 55 cases was 3.06 (standard deviation of 0.21), while it was 2.87 (0.24) for the corresponding reconstructions. The difference in {beta} for a given patient between the projection ROIs and the reconstructed ROIs averaged across the 55 cases was 0.194, which was statistically significant (p<0.001). The 95% CI for the difference between the mean value of {beta} for the projections and reconstructions was [0.170, 0.218]. The results are consistent with the observation that the amount of breast structure in the tomosynthesis slice is reduced compared to projection mammography and that this may lead to improved lesion detectability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Evaluation of Pressure and Flow Measurement in the Molten Salt Test Loop (MSTL) System

The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL allows customers and researchers to test components in flowing, molten nitrate salt at plant-like conditions for pressure, flow, and temperature. An important need in thermal storage systems that utilize molten salts is for accurate flow and pressure measurement at temperatures above 535ÀC. Currently available flow and pressure instrumentation for molten salt is limited to 535ÀC and even at this temperature the pressure measurement appears to have significant variability. It is the design practice in current Concentrating Solar Power plants to measure flow and pressure on the cold side of the process or in dead-legs where the salt can cool, but this practice won t be possible for high temperature salt systems. For this effort, a set of tests was conducted to evaluate the use of the pressure sensors for flow measurement across a device of known flow coefficient Cv. To perform this task, the pressure sensors performance was evaluated and was found to be lacking. The pressure indicators are severely affected by ambient conditions and were indicating pressure changes of nearly 200psi when there was no flow or pressure in the system. Several iterations of performance improvement were undertaken and the pressure changes were reduced to less than 15psi. The results of these pressure improvements were then tested for use as flow measurement. It was found that even with improved pressure sensors, this is not a reliable method of flow measurement. The need for improved flow and pressure measurement at high temperatures remains and will need to be solved before it will be possible to move to high temperature thermal storage systems with molten salts.

Gill, David Dennis↗

Best Practices for Shielding Analyses of Activated Metals and Spent Resins from Reactor Operation

This report investigated best practices for performing shielding evaluations of Type B waste packages, as defined in 10 CFR Part 71 regulations on packaging and transportation of radioactive material, or packages for which the contents are not defined before loading and may include a broad range of nuclides, geometries, and non-fuel materials. The following non-fuel waste streams were analyzed: Activated metals from decommissioned commercial power reactors, including Type 304 stainless steel, reactor vessel steel, and Inconel, Control blades from boiling water reactors, Neutron-activated corrosion products on surfaces of activated metals, and Spent resins from power plant operations. Measured elemental compositions, including major constituents and impurities, for steel and Inconel samples from commercial power reactors were used in activation calculations to determine radionuclide inventories in activated metals. For a simplified cask model, 60 Co contribution to the total external package dose rate at 30 days after shutdown varied from approximately 60% to 95%, depending on the activated metal, initial cobalt impurity concentration in the metal, and the thickness of the overpack gamma shield. Its maximum contribution to the total external package dose rate of approximately 100% was reached within the time interval of 2 to 5 years after shutdown and was maintained for up to 45 to 60 years after shutdown, depending on material, initial cobalt impurity concentration, and shield thickness. Thereafter, the 60 Co contribution to external package dose rate decreased with increasing decay time. Cobalt-60 is primarily produced by neutron reactions with the cobalt impurity in steel and Inconel. Other important radionuclides in activated metals contributing to package external dose rate are radionuclides with relatively short decay times, including 51 Cr, 59 Fe, 58 Co, and 54 Mn. These radionuclides may be represented as an equivalent 60 Co activity/source because 60 Co gamma ray emissions are bounding in terms of source strength and energy to other important radionuclides identified in the analyzed activated metals. Approaches for modeling the neutron-activated corrosion products that may be attached to activated reactor components were analyzed in this report. It was demonstrated that a surface source is more conservative than a uniform volumetric source for the treatment of neutron-activated corrosion products with respect to external package dose rates. An analysis of the maximum radionuclide loadings reported on spent resins identified the radionuclides 137 Cs, 60 Co, 134 Cs, 65 Zn, and 58 Co as the primary contributors to external package dose rate. For a resin cooled for 3.08 years, the external package dose rate was entirely produced by the reported 137 Cs and 60 Co inventory. The neutron sources from actinides found on spent resins or activated metals produced negligible dose rates and may be ignored in dose rate analyses. Effects of idealized waste material, source geometry, and spatial material/source distributions on external package dose rates were determined based on dose rate results for a simplified cask model under normal conditions of transport. Type 304 stainless steel, zirconium, and aluminum with adjusted mass densities based on a maximum content weight were analyzed for material modeling effects on external package dose rate. These materials produced identical external package dose rates within the statistical uncertainties of the dose rate estimates. Among four different source geometry configurations with homogeneous material of different mass densities, uniform volumetric source distribution, and the same source strength, the geometry configuration with lowest mass density (i.e., minimum self-shielding effect among the four cases) was most conservative. Spatial source distributions that better represent localized peak 60 Co activity values were more conservative than a uniform volumetric source distribution, assuming the same weight and total source strength per package. The increase in external dose rate caused by localized source peaks can be as much as the ratio between source peak activity density to average activity density, depending on the location of the activated metal with peak activity density. Therefore, the shielding analysis may be simplified if localized peak activities and the average activity per package can be measured/determined and documented at the time of cask loading. For simplicity, external package dose rates may be determined based on average source activity and a uniform volumetric source distribution. The dose rate results from that calculation model multiplied by the ratio of peak activity density to average activity density will produce maximum dose rate values for conservative estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aeropropulsive Assessment of a BLI Tail-Cone Thruster Propulsion System for the NASA Common Research Model and a Transonic Truss-Braced Wing Configuration

This paper presents an investigation into the potential benefits of a boundary layer ingestion(BLI) aft fuselage propulsion system, or tail-cone thruster (TCT), when applied to two transport category aircraft: a conventional tube-and-wing configuration based on the NASA Common Research Model (CRM) and a transonic truss-braced wing (TTBW) configuration. Through the ingestion of low-momentum flow developed over the airframe of an aircraft, the TCT propulsion system technology can reduce overall power consumption and hence fuel burn and emissions. However, an accurate assessment of this potential requires the application of high-fidelity analysis tools that can capture the relevant propulsion-airframe integration effects, at least to first order. Toward this end, the present study employs aeropropulsive analysis tools based on the Reynolds-averaged Navier-Stokes equations to estimate the power savings coefficient, measured relative to equivalent non-BLI configurations of a given airframe. Results indicate shaft power savings of 4.1% and 5.9% can be obtained for the boundary-layer ingesting TCT configuration of the CRM and TTBW, respectively. The present study also examines the coupling between airframe aerodynamics and the inlet flow distortion experienced by the TCT of a given aircraft configuration through airframe component sensitivity studies.

AATT↗

Reconstruction of the primordial power spectrum from CMB data

Measuring the deviation from scale invariance of the primordial power spectrum is a critical test of inflation. In this paper we reconstruct the shape of the primordial power spectrum of curvature perturbations from the cosmic microwave background data, including the 7-year Wilkinson Microwave Anisotropy Probe data and the Atacama Cosmology Telescope 148 GHz data, by using a binning method of a cubic spline interpolation in log-log space. We find that the power-law spectrum is preferred by the data and that the Harrison-Zel'dovich spectrum is disfavored at 95% confidence level. These conclusions hold with and without allowing for tensor modes, however the simpler model without tensors is preferred by the data. We do not find evidence for a feature in the primordial power spectrum — in full agreement with generic predictions from cosmological inflation.

79 ASTRONOMY AND ASTROPHYSICS↗

Hypermetallic polar molecules for precision measurements

Laser cooling is a powerful method to control molecules for applications in precision measurement, as well as quantum information, many-body physics, and fundamental chemistry. However, many optically-active metal centers in valence states which are promising for these applications, especially precision measurement, are difficult to laser cool. In order to extend the control afforded by laser cooling to a wider array of promising atoms, we consider the use of small, hypermetallic molecules that contain multiple metal centers. We provide a detailed analysis of YbCCCa and YbCCAl as prototypical examples with different spin multiplicities, and consider their feasibility for precision measurements making use of the heavy Yb atom. We find that these molecules are linear and feature metal-centered valence electrons, and study the complex hybridization and spin structures that are relevant to photon cycling and laser cooling. Our findings suggest that this hypermetallic approach may be a versatile tool for experimental control of metal species that do not otherwise efficiently cycle photons, and could present a new polyatomic platform for state-of-the-art precision measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Neutron-deuteron analyzing power data at 19.0 MeV

Measurements of neutron-deuteron (n-d) analyzing power A{sub y}(theta) at E{sub n}=19.0 MeV are reported at 16 angles from theta{sub c.m.}=46.7 to 152.0 deg. The objective of the experiment is to better characterize the discrepancies between n-d data and the predictions of three-nucleon calculations for neutron energies above 16.0 MeV. The experiment used a shielded neutron source, which produced polarized neutrons via the {sup 2}H(d-vector,n-vector){sup 3}He reaction, a deuterated liquid scintillator center detector (CD) and liquid-scintillator neutron side detectors. A coincidence between the CD and the side detectors isolated the elastic-scattering events. The CD pulse height spectrum associated with each side detector was sorted by using pulse-shape discrimination, time-of-flight techniques, and by removing accidental coincidences. A Monte Carlo computer simulation of the experiment accounted for effects due to finite geometry, multiple scattering, and CD edge effects. The resulting high-precision data (with absolute uncertainties ranging from 0.0022 to 0.0132) have a somewhat lower discrepancy with the predictions of three-body calculations, as compared to those found at lower energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time filtering of event based neutron scattering data: A pathway to study the dynamic structural responses of materials

Time-resolved diffraction has become a vital tool for probing dynamic responses to an applied stimulus. Such experiments traditionally use hardware solutions to histogram measured data into their respective bin. We will show that a major advantage of event-based data acquisition, which time-stamps measured diffraction data with 100 ns accuracy, is much preferred over hardware histogramming of the data by enabling postprocessing for advanced custom binning using a software solution. This approach is made even more powerful by coupling measured diffraction data with metadata about the applied stimuli and material response. In this work, we present a time-filter approach that leverages the power of event-based diffraction collection to reduce stroboscopic data measured over many hours into equally weighted segments that represent subsets of the response to a single cycle of the applied stimulus. We demonstrate this approach by observing ferroelectric/ferroelastic domain wall motion during electric field cycling of BaTiO 3 . Furthermore, the developed approach can readily be expanded to investigate other dynamic phenomena using complex sample environments.

47 OTHER INSTRUMENTATION↗

New Submount Requirement of Conductively Cooled Laser Diodes for Lidar Applications

New submount technology is essential for the development of conductively cooled high power diode laser. The simulation and experimental results indicate that thermal conductivity of submount for high power laser-diode must be at least 600 W/m/k or higher for stable operation. We have simulated several theoretical thermal model based on new submount designs and characterized high power diode lasers to determine temperature effects on the performances of laser diodes. The characterization system measures the beam power, output beam profile, temperature distribution, and spectroscopic property of high power diode laser. The characterization system is composed of four main parts: an infrared imaging camera, a CCD camera, a monochromator, and a power meter. Thermal characteristics of two commercial-grade CW 20-W diode laser bars with open heat-sink type were determined with respect to the line shift of emission spectra and beam power stability. The center wavelength of laser emission has a tendency to shift toward longer wavelength as the driving current and heat sink temperature are increased. The increase of heat sink temperature decreases the output power of the laser bar too. Such results lay the guidelines for the design of new submount for high power laser-diodes.

Mo, S. Y.↗

Estimation of steady-state and transcient power distributions for the RELAP analyses of the 1963 loss-of-flow and loss-of-pressure tests at BR2.

To support the safety analyses required for the conversion of the Belgian Reactor 2 (BR2) from highly-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, the simulation of a number of loss-of-flow tests, with or without loss of pressure, has been undertaken. These tests were performed at BR2 in 1963 and used instrumented fuel assemblies (FAs) with thermocouples (TC) imbedded in the cladding as well as probes to measure the FAs power on the basis of their coolant temperature rise. The availability of experimental data for these tests offers an opportunity to better establish the credibility of the RELAP5-3D model and methodology used in the conversion analysis. In order to support the HEU to LEU conversion safety analyses of the BR2 reactor, RELAP simulations of a number of loss-of-flow/loss-of-pressure tests have been undertaken. Preliminary analyses showed that the conservative power distributions used historically in the BR2 RELAP model resulted in a significant overestimation of the peak cladding temperature during the transient. Therefore, it was concluded that better estimates of the steady-state and decay power distributions were needed to accurately predict the cladding temperatures measured during the tests and establish the credibility of the RELAP model and methodology. The new approach ('best estimate' methodology) uses the MCNP5, ORIGEN-2 and BERYL codes to obtain steady-state and decay power distributions for the BR2 core during the tests A/400/1, C/600/3 and F/400/1. This methodology can be easily extended to simulate any BR2 core configuration. Comparisons with measured peak cladding temperatures showed a much better agreement when power distributions obtained with the new methodology are used.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monte Carlo control loops for cosmic shear cosmology with DES Year 1 data

Weak lensing by large-scale structure is a powerful probe of cosmology and of the dark universe. This cosmic shear technique relies on the accurate measurement of the shapes and redshifts of background galaxies and requires precise control of systematic errors. Monte Carlo control loops (MCCL) is a forward modeling method designed to tackle this problem. It relies on the ultra fast image generator (UFig) to produce simulated images tuned to match the target data statistically, followed by calibrations and tolerance loops. Here, we present the first end-to-end application of this method, on the Dark Energy Survey (DES) Year 1 wide field imaging data. We simultaneously measure the shear power spectrum $C_ℓ$ and the redshift distribution $n(z)$ of the background galaxy sample. The method includes maps of the systematic sources, point spread function (PSF), an approximate Bayesian computation (ABC) inference of the simulation model parameters, a shear calibration scheme, and a fast method to estimate the covariance matrix. We find a close statistical agreement between the simulations and the DES Y1 data using an array of diagnostics. In a nontomographic setting, we derive a set of $C_ℓ$ and $n(z)$ curves that encode the cosmic shear measurement, as well as the systematic uncertainty. Following a blinding scheme, we measure the combination of $Ω_m$, $σ_8$, and intrinsic alignment amplitude $A_{IA}$, defined as $S_8D_{IA}=σ_8(Ω_m/0.3)^{0.5}D_{IA}$, where $D_{IA}=1-0.11(A_{IA}-1)$. We find $S_8D_{IA}=0.8954_{-0.039}^{+0.054}$, where systematics are at the level of roughly 60% of the statistical errors. We discuss these results in the context of earlier cosmic shear analyses of the DES Y1 data. Our findings indicate that this method and its fast runtime offer good prospects for cosmic shear measurements with future wide-field surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo Control Loops for Cosmic Shear Cosmology with DES Year 1

Weak lensing by large-scale structure is a powerful probe of cosmology and of the dark universe. This cosmic shear technique relies on the accurate measurement of the shapes and redshifts of background galaxies and requires precise control of systematic errors. The Monte Carlo Control Loops (MCCL) is a forward modelling method designed to tackle this problem. It relies on the Ultra Fast Image Generator (UFig) to produce simulated images tuned to match the target data statistically, followed by calibrations and tolerance loops. We present the first end-to-end application of this method, on the Dark Energy Survey (DES) Year 1 wide field imaging data. We simultaneously measure the shear power spectrum $C_{\ell}$ and the redshift distribution $n(z)$ of the background galaxy sample. The method includes maps of the systematic sources, Point Spread Function (PSF), an Approximate Bayesian Computation (ABC) inference of the simulation model parameters, a shear calibration scheme, and the fast estimation of the covariance matrix. We find a close statistical agreement between the simulations and the DES Y1 data using an array of diagnostics. In a non-tomographic setting, we derive a set of $C_\ell$ and $n(z)$ curves that encode the cosmic shear measurement, as well as the systematic uncertainty. Following a blinding scheme, we measure the combination of $\Omega_m$, $\sigma_8$, and intrinsic alignment amplitude $A_{\rm{IA}}$, defined as $S_8D_{\rm{IA}} = \sigma_8(\Omega_m/0.3)^{0.5}D_{\rm{IA}}$, where $D_{\rm{IA}}=1-0.11(A_{\rm{IA}}-1)$. We find $S_8D_{\rm{IA}}=0.895^{+0.054}_{-0.039}$, where systematics are at the level of roughly 60\% of the statistical errors. We discuss these results in the context of earlier cosmic shear analyses of the DES Y1 data. Our findings indicate that this method and its fast runtime offer good prospects for cosmic shear measurements with future wide-field surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Standardizing power monitoring and control at exascale

Power API-the result of collaboration among national laboratories, universities, and major vendors-provides a range of standardized power management functions, from application-level control and measurement to facility-level accounting, including real-time and historical statistics gathering. Here, support is already available for Intel and AMD CPUs and standalone measurement devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗