Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Details of the NOvA 3-flavor oscillation analysis

NOvA is a world-leading long-baseline neutrino oscillation experiment. Its fine granularity allows the detection and identification of particle interactions in the detectors, notably muon and electron neutrino interactions. NOvA can measure the electron neutrino and antineutrino appearance rates, as well as the muon neutrino and antineutrino disappearance rates, in order to constrain the neutrino oscillations parameters, the neutrino mass hierarchy and the CP-violating phase $\delta_{CP}$.NOvA's latest results combine both neutrino data (8.85$\times{}10^{20}$ POT) and antineutrino data (12.33$\times{}10^{20}$ POT). A 4.4$\sigma$ evidence for $\overline{\nu}_{e}$ appearance in a $\overline{\nu}_{\mu}$ beam was measured. In addition, NOvA favors the Normal Hierachy (1.9$\sigma$) and prefers the Upper Octant for $\theta_{23}$ (1.6$\sigma$).}

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPRUCE Climate Warming and Elevated CO2 Rapidly Alter Peatland Soil Carbon Sources and Stability: Supporting Data

This data set reports a suite of complementary biogeochemical analyses of peat samples from the SPRUCE (Spruce and Peatland Responses Under Changing Environments) experiment. Results were collected using quantitative molecular analysis of bulk soil carbon to assess the stability of soil organic carbon following whole-ecosystem warming and exposure to elevated carbon dioxide concentrations (eCO2). Targeted soil organic carbon components include solvent-extractable compounds (alkanoic acids, alkanols, alkanes, steroids, and terpenoids), ester-bound hydrolysable biopolymers (cutin and suberin markers), lignin phenols, and pyrogenic carbon. Bulk peat samples were analysed by Soxhlet extraction and solid phase separation for solvent-extractable compounds, alkaline hydrolysis to extract hydrolysable biopolymers, copper (II) oxide oxidation to extract lignin phenols and benzene polycarboxylic acids (BPCAs) as an approximation of pyrogenic carbon. Samples were analysed by gas chromatography (GC) equipped with a flame ionization detector (GC-FID) and compound identification was performed on GC coupled to mass selective detector (MS) for solvent-extractable compounds, ester-bound hydrolysable biopolymers and lignin phenols, and high-performance liquid chromatograph (HPLC) for pyrogenic carbon. Results are presented in Ofiti et al. (accepted). The experimental work was conducted on samples collected in August 2018 at the SPRUCE climate manipulation experiment in northern Minnesota, 40 km north of Grand Rapids, in the USDA Forest Service Marcell Experimental Forest (MEF). Samples were collected and later analysed in a 10 cm increments over 0 to 50 cm depth and 25 cm intervals from 50 to 75 cm. Samples were analyzed for lignin phenols over 0 to 30 cm depth. This data set contains one file in comma separate (*.csv) format. This dataset contains data used to produce: Ofiti, N.O.E., Schmidt, M.W.I., Abiven, S., Hanson, P.J., Iversen, C.M., Wilson, R.M., Kostka, J.E., Wiesenberg, G.L.B., Malhotra, A. 2023. Climate warming and elevated CO2 rapidly alter peatland soil carbon sources and stability. Nat Commun 14, 7533. https://doi.org/10.1038/s41467-023-43410-z.

SPRUCE experiment, Marcell Experimental Forest, so↗

Uncertainty as a Function of Time for Subcritical Experiment Parameters Using the Hage-Cifarelli Formalism

When designing critical or subcritical experiments, it is desirable to have an estimate of the measurement uncertainties prior to performing an experiment. In addition, an important goal is to have the smallest measurement uncertainties possible given measurement time constraints. Having well-designed experiments with small uncertainties helps improve nuclear data and therefore has direct impacts on criticality safety. This work shows how the uncertainties in various measurement parameters vary as a function of counting time and provides an approach to estimate measured uncertainties and guides in optimizing the available counting time. The uncertainty in six parameters used in subcritical experiments was investigated as a function of time: singles count rate (R{sub 1}), doubles count rate (R{sub 2}), lifetime (1/λ), leakage multiplication (M{sub L}), spontaneous fission rate (FS), and detector efficiency (ε). A comparison to measured data will be presented at the meeting. The approach and results in this work will be used to optimize measurement time in future subcritical experiments and will be used to help estimate measurement uncertainties during the design phase. Having well-designed experiments with the smallest uncertainties possible can help the criticality safety community through data validation. (authors)

42 ENGINEERING↗

Measurement of the W-boson angular coefficients and transverse momentum in pp collisions at s=13 TeV with the ATLAS detector

The angular distributions of Drell–Yan lepton pairs provide sensitive probes of the underlying dynamics of quantum chromodynamics (QCD) effects in vector-boson production. This paper presents for the first time the measurement of the full set of angular coefficients together with the differential cross-section as a function of the transverse momentum of the W boson, in the full phase space of the decay leptons. The measurements are performed separately for the W-$$W^-$$ and W+$$W^+$$ channels. The analysis uses proton–proton collision data recorded by the ATLAS experiment at the Large Hadron Collider in 2017 and 2018, during special low-luminosity runs with a reduced number of interactions per bunch crossings (pile-up). The data correspond to an integrated luminosity of 338 pb-1$$^{-1}$$ at a centre-of-mass energy of s=13$$\sqrt{s} = 13$$ TeV. The low pile-up environment provides excellent experimental conditions for high-precision measurements of W-boson production. All results agree with theoretical predictions incorporating finite-order QCD corrections up to order αS2$$\alpha _S^2$$.

Aad, G↗

Formation of scandium carbides and scandium oxycarbide from the elements at high-(P, T) conditions

Synchrotron diffraction experiments with in situ laser heated diamond anvil cells and multi-anvil press synthesis experiments have been performed in order to investigate the reaction of scandium and carbon from the elements at high-(P,T) conditions. It is shown that the reaction is very sensitive to the presence of oxygen. In an oxygen-rich environment the most stable phase is ScO{sub x}C{sub y}, where for these experiments x=0.39 and y=0.50-0.56. If only a small oxygen contamination is present, we have observed the formation of Sc{sub 3}C{sub 4}, Sc{sub 4}C{sub 3} and a new orthorhombic ScC{sub x} phase. All the phases formed at high pressures and temperatures are quenchable. Experimentally determined elastic properties of the scandium carbides are compared to values obtained by density functional theory based calculations. - Graphical Abstract Legend (TOC Figure): Table of Contents Figure Selected images recorded with a MAR345 image plate detector show the reaction of alpha-Sc and graphite at high-(P,T) conditions. Left: mixture of alpha-Sc and graphite. Right: recovered sample after laser heated the diamond anvil cell.

36 MATERIALS SCIENCE↗

Laser pulse amplitude changes induced by terahertz waves under linear electro-optic effect

Changes in the amplitude of femtosecond laser pulses and in the energy of terahertz wave radiation induced during their co-propagation in ZnTe and GaP crystals are studied theoretically and experimentally. The results show that variation of the optical field amplitude leads to changes in the laser pulse energy and spectrum shift. We investigate the quantitative correlations between variations of the optical pulse energy, spectrum, phase and terahertz radiation energy. The values of laser pulse energy change and spectrum shift are proportional to the first time derivative of the magnitude of terahertz electric field, which enables coherent electro-optic detection. A simple and convenient calibration technique for terahertz energy detectors based on the correlation between laser and terahertz energy changes is proposed and tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent three-flavor neutrino oscillation results from the NOvA experiment

NOvA is a long-baseline experiment studying primarily neutrino oscillations in the NuMI beam from Fermi National Laboratory (FNAL), USA. It consists of two functionally identical, finely granulated detectors which are separated by 810 km and situated 14.6 mrad off the NuMI beam axis from FNAL. By measuring the transition probabilities P(vμ → ve) and P(vμ → vμ), NOvA is able to probe the following parameters: , the mixing angle θ23, the CP violating phase δCP and the neutrino mass hierarchy. This document is devoted to the latest NOvA measurements of the neutrino oscillation parameters using neutrino and antineutrino disappearance and appearance obtained in 2020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectroscopy of particle couplings with gravitational waves

We discuss the possibility to measure particle couplings with stochastic gravitational wave backgrounds (SGWBs). Under certain circumstances a sequence of peaks of different amplitude and frequency — a stairway — emerges in a SGWB spectrum, with each peak probing a different coupling. The detection of such signature opens the possibility to reconstruct couplings (spectroscopy) of particle species involved in high energy phenomena generating SGWBs. Stairwaylike signatures may arise in causally produced backgrounds in the early Universe, e.g., from preheating or first order phase transitions. As a proof of principle we study a preheating scenario with an inflaton $\phi$ coupled to multiple daughter fields {$χ_j$} with different coupling strengths. As a clear stairway signature is imprinted in the SGWB spectrum, we reconstruct the relevant couplings with various detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Summaries of FY16 LANL experimental campaigns at the OMEGA and EP Laser Facilities

In FY16, Los Alamos National Laboratory carried out 22 shot days on the OMEGA and OMEGA- EP laser facilities in the areas of High Energy Density (HED) Science and Inertial Confinement Fusion (ICF). In HED our focus areas were on radiation flow, hydrodynamic turbulent mix and burn, warm dense matter equations of state, and coupled Kelvin-­Helmholtz (KH)/Richtmyer-­ Meshkov (RM) instability growth. For ICF our campaigns focused on the Priority Research Directions (PRD) of implosion phase mix and stagnation and burn, specifically as they pertain to Laser Direct Drive (LDD). We also had several focused shot days on transport properties in the kinetic regime. We continue to develop advanced diagnostics such as Neutron Imaging, Gamma Reaction History, and Gas Cherenkov Detectors. Below are a summary of our campaigns, their motivation, and main results from this year.

42 ENGINEERING↗

Latest three-flavor neutrino oscillation results from NOvA

The NOvA experiment is a long-baseline neutrino oscillation experiment that uses the upgraded NuMI beam from Fermilab to detect both electron neutrino appearance and muon neutrino disappearance.NOvA employs two functionally identical detectors: a Near Detector, located at Fermilab, and a Far Detector, located at Ash River, Minnesota over an 810 km baseline. NOvA’s primary physics goals include precision measurements of neutrino oscillation parameters, such as $\theta_{23}$ and the atmospheric mass-squared splitting, along with probes of the mass hierarchy and the CP violating phase. This document is devoted to the latest NOvA measurements of the neutrino oscillation parameters using neutrino and antineutrino disappearance and appearance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnosing ICF gamma-ray physics

Gamma rays produced in an ICF environment open up a host of physics opportunities we are just beginning to explore. A branch of the DT fusion reaction, with a branching ratio on the order of 2e-5 {gamma}/n, produces 16.7 MeV {gamma}-rays. These {gamma}-rays provide a direct measure of fusion reaction rate (unlike x-rays) without being compromised by Doppler spreading (unlike neutrons). Reaction-rate history measurements, such as nuclear bang time and burn width, are fundamental quantities that will be used to optimize ignition on the National Ignition Facility (NIF). Gas Cherenkov Detectors (GCD) that convert fusion {gamma}-rays to UV/visible Cherenkov photons for collection by fast optical recording systems established their usefulness in illuminating ICF physics in several experimental campaigns at OMEGA. Demonstrated absolute timing calibrations allow bang time measurements with accuracy better than 30 ps. System impulse response better than 95 ps fwhm have been made possible by the combination of low temporal dispersion GCDs, ultra-fast microchannel-plate photomultiplier tubes (PMT), and high-bandwidth Mach Zehnder fiber optic data links and digitizers, resulting in burn width measurement accuracy better than 10ps. Inherent variable energy-thresholding capability allows use of GCDs as {gamma}-ray spectrometers to explore other interesting nuclear processes. Recent measurements of the 4.44 MeV {sup 12}C(n,n{prime}) {gamma}-rays produced as 14.1 MeV DT fusion neutrons pass through plastic capsules is paving the way for a new CH ablator areal density measurement. Insertion of various neutron target materials near target chamber center (TCC) producing secondary, neutron-induced {gamma}y-rays are being used to study other nuclear interactions and as in-situ sources to calibrate detector response and DT branching ratio. NIF Gamma Reaction History (GRH) diagnostics, based on the GCD concept, are now being developed based on optimization of sensitivity, bandwidth, dynamic range, cost, and NIF-specific logistics, requirements and extreme radiation environment. Implementation will occur in two phases: (1) four PMT-based channels mounted to the outside of the target chamber at {approx}6m from TCC (GRH-6m) for the 3e13-3e16 DT neutron yield range expected during the early ignition-tuning campaigns; and (2) several channels located just inside the target bay shield wall at 15 m from TCC (GRH-15m) with optical paths leading through the cement shield wall to well-shielded streak cameras and PMTs for the 1e16-1e20 yield range expected during the DT ignition campaign. Multiple channels at each phase will allow for increased redundancy, reliability, accuracy and flexibility. This suite of diagnostics will make possible exploration of interesting {gamma}-ray physics well beyond the ignition campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

Fast neutron-gamma discrimination on neutron emission profile measurement on JT-60U

A digital signal processing (DSP) system is applied to stilbene scintillation detectors of the multichannel neutron emission profile monitor in JT-60U. Automatic analysis of the neutron-{gamma} pulse shape discrimination is a key issue to diminish the processing time in the DSP system, and it has been applied using the two-dimensional (2D) map. Linear discriminant function is used to determine the dividing line between neutron events and {gamma}-ray events on a 2D map. In order to verify the validity of the dividing line determination, the pulse shape discrimination quality is evaluated. As a result, the {gamma}-ray contamination in most of the beam heating phase was negligible compared with the statistical error with 10 ms time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Low Temperature on a 4 W/60 K Pulse-Tube Cryocooler for Cooling HgCdTe Detector

Temperature is an extremely important parameter for the material of the space-borne infrared detector. To cool an HgCdTe-infrared detector, a Stirling-type pulse-tube cryocooler (PTC) has been developed based on a great deal of numerical simulations, which are performed to investigate the thermodynamic behaviors of the PTC. The effects of different low temperatures are presented to analyze different energy flows, losses, phase shifts, and impedance matching of the PTC at a temperature range of 40–120 K, where woven wire screens are used. Finally, a high-efficiency coaxial PTC has been designed, built, and tested, operating around 60 K after a number of theoretical and experimental studies. The PTC can offer a no-load refrigeration temperature of 40 K with an input electric power of 150 W, and a cooling power of 4 W at 60 K is obtained with Carnot efficiency of 12%. In addition, a comparative study of simulation and experiment has been carried out, and some studies on reject temperatures have been presented for a thorough understanding of the PTC system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FELIX: a PCIe based high-throughput approach for interfacing front-end and trigger electronics in the ATLAS Upgrade framework

The ATLAS Phase-I upgrade (2019) requires a Trigger and Data Acquisition (TDAQ) system able to trigger and record data from up to three times the nominal LHC instantaneous luminosity. Furthermore, the Front-End LInk eXchange (FELIX) system provides an infrastructure to achieve this in a scalable, detector agnostic and easily upgradeable way. It is a PC-based gateway, interfacing custom radiation tolerant optical links from front-end electronics, via PCIe Gen3 cards, to a commodity switched Ethernet or InfiniBand network. FELIX enables reducing custom electronics in favour of software running on commercial servers. Here, the FELIX system, the design of the PCIe prototype card and the integration test results are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase-sensitive optomechanical amplifier for quantum noise reduction in laser interferometers

The sensitivity of future gravitational wave interferometers is expected to be limited throughout the detection band by quantum vacuum fluctuations, which can be reduced by applying quantum optics techniques such as squeezed vacuum injection. However, decoherence caused by optical losses in the readout chain will severely limit the effectiveness of such schemes. It was proposed that effect of losses in the final stage of detection can be mitigated by a phase-sensitive amplifier placed in between the output port of the interferometer and the photodetector. In this paper we propose to implement such amplification using an optomechanical device, study some of its practical limitations, and finally, discuss its applicability to next-generation gravitational-wave detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

First measurement of Φ₃ with a model-independent Dalitz plot analysis of B ± →DK ± , D→K S ⁰π⁺π⁻ decay

We present the first measurement of the angle Φ₃ of the unitarity triangle using a model-independent Dalitz plot analysis of B ± →DK ± , D→K S ⁰π⁺π⁻ decays. The method uses, as input, measurements of the strong phase of the D→K⁰ S π⁺π⁻ amplitude from the CLEO Collaboration. The result is based on the full data set of 772×106 BB¯¯¯ pairs collected by the Belle experiment at the Υ(4S) resonance. We obtain Φ₃=(77.3 +15.1 –14.9 ±4.1±4.3)° and the suppressed amplitude ratio r B =0.145±0.030±0.010±0.011. Here the first error is statistical, the second is the experimental systematic uncertainty, and the third is the error due to the precision of the strong-phase parameters obtained by CLEO.

Aihara, H.↗